Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Astro-H High Resolution Soft X-Ray Spectrometer

We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.

spectrometers↗

PheniX: A New Vision for the Hard X-ray Sky

We are proposing a mission devoted to high energy X-ray astronomy that is based on a focusing telescope operating in the 1-200 keV energy range but optimized for the hard X-ray range. The main scientific topics concern: Physics of compact objects: The proximity of compact objects provides a unique laboratory to study matter and radiation in extreme conditions of temperature and density in strong gravitational environment. The emission of high energy photons from these objects is far from being understood. The unprecedented sensitivity in the high energy domain will allow a precise determination of the non-thermal processes at work in the vicinity of compact objects. The full 1-200 keV energy coverage will be ideal to disentangle the emission processes produced in the spacetime regions most affected by strong-gravity, as well as the physical links: disk-thermal emission-iron line-comptonisation-reflection-non-thermal emission-jets. Neutron stars-magnetic field-cyclotron lines: Time resolved spectroscopy (and polarimetry) at ultra-high sensitivity of AXP, milliseconds pulsars and magnetars will give new tools to study the role of the synchrotron processes at work in these objects. Cyclotron lines-direct measurement of magnetic filed-equation of state constraints-short bursts-giant flares could all be studied with great details. AGN: The large sensitivity improvement will provide detailed spectral properties of the high energy emission of AGN's. This will give a fresh look to the connection between accretion and jet emission and will provide a new understanding of the physical processes at work. Detection of high-redshift active nuclei in this energy range will allow to introduce an evolutionary aspect to high-energy studies of AGN, probing directly the origin of the Cosmic X-ray Background also in the non-thermal range (> 20 keV). Element formation-Supernovae: The energy resolution achievable for this mission (<0.5 keV) and a large high energy effective area are ideally suited for the 44Ti line study (68 and 78 keV). This radioactive nuclei emission will give an estimate of their quantities and speed in their environment. In addition the study of the spatial structure and spectral emission of SNR will advance our knowledge of the dynamics of supernovae explosions, of particles acceleration mechanisms and how the elements are released in the interstellar medium. Instrumental design: The progress of X-ray focusing optics techniques allows a major step in the instrumental design: the collecting area becomes independent of the detection area. This drastically reduces the instrumental background and will open a new era. The optics will be based on depth-graded multi-layer mirrors in a Wolter I configuration. To obtain a significant effective area in the hundred of keV range a focal length in the 40-50 meters range (attainable with a deployable mast) is needed. In addition such a mission could benefit from recent progress made on mirror coating. We propose to cover the 1-200 keV energy range with a single detector, a double-sided Germanium strip detector operating at 80 K. The main features will be: (a) good energy resolution (.150 keV at 5 keV and <.5 keV at 100 keV), (b) 3 dimensional event localization with a low number of electronic chains, (c) background rejection by the 3D localization, (d) polarisation capabilities in the Compton regime.

PHENIX↗

Effects of Normal Metal Features on Superconducting Transition-Edge Sensors

In transition-edge sensors (TESs), the addition of normal metal stripes on top of the superconducting bilayer, perpendicular to the current direction, is known to globally alter the sensitivity of the resistance R to changes in temperature T and current I. Here, we describe measurements of the dependence of the TES current on magnetic field B, bath temperature and voltage bias in devices with various numbers of stripes. We show that the normal metal features have a profound effect on the appearance of localized regions of very large (T/R) dR/dT. We associate this with changes in the current distribution and corresponding changes in the oscillatory pattern of I (B). 140 μm TESs with no stripes are found to have a relatively smooth resistive transition and sufficiently low noise that the measured energy resolution is 1.6 eV for X-rays of 1.5 keV. The predicted energy resolution at 6 keV is better than 2 eV, once the heat capacity is optimized for these higher energies..

Wakeham, N. A.↗

Instrument Development for X-Ray Astronomy

Current x-ray observatories such as Chandra and XMM-Newton have delivered spectacular results at soft-x-ray energies thanks to their grazing incidence mirrors. To continue these advances necessitates the development of mirrors with even larger collecting areas, yet within manageable weights and budgets, and focal detectors with improved energy resolution. At higher energies where x-ray critical-grazing angles become very small, x-ray optics have typically not been employed and thus this region remains relatively unexplored at high sensitivity levels and fine angular resolutions. This situation is changing with the development of hard-x-ray optics carried aloft by high-altitude balloons, which promise to bring about dramatic advances. This presentation will review developments in all these areas.

Ramsey, Brian↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Solar flare hard X-ray observations

Recent hard X-ray observations of solar flares are reviewed with emphasis on results obtained with instruments on the solar maximum satellite. Flares with three sets of characteristics, designated as Type A, Type B, and Type C, are discussed and hard X-ray temporal, spatial spectral, and polarization measurements are reviewed in this framework. Coincident observations are reviewed at other wavelengths including the UV, microwaves, and soft X-rays, with discussions of their interpretations. In conclusion, a brief outline is presented of the potential of future hard X-ray observations with sub-second time resolution, arcsecond spatial resolution, and keV energy resolution, and polarization measurements at the few percent level up to 100 keV.

Dennis, Brian R.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion↗

Radiation damage of the HEAO C-1 germanium detectors

The effects of radiation damage from proton bombardment of the four HEAO C-1 high purity germanium detectors have been measured and compared to predictions. Because of the presence of numerous gamma-ray lines in the detector background spectra and because of the relatively long exposure time of the HEAO 3 satellite to cosmic-ray and trapped protons, it has been possible to measure both the energy and time dependence of radiation damage. After 100 d in orbit, each of the four detectors has been exposed to approximately 3 x 10 to the 7th protons/sq cm, and the average energy resolution at 1460 keV had degraded from 3.2 keV fwhm to 8.6 keV fwhm. The lines were all broadened to the low energy side although the line profile was different for each of the four detectors. The damage-related contribution to the degradation in energy resolution was found to be linear in energy and proton influence.

Mahoney, W. A.↗

Phonons reveal coupled cholesterol-lipid dynamics in ternary membranes

Experimental studies of collective dynamics in lipid bilayers have been challenging due to the energy resolution required to observe these low-energy phonon-like modes. However, inelastic X-ray scattering (IXS) measurements — a technique for probing vibrations in soft and biological materials — are now possible with sub-meV resolution, permitting direct observation of low energy, phonon-like modes in lipid membranes. Here, in this study, IXS measurements with sub-meV energy resolution reveal a low-energy optic-like phonon mode at roughly 3 meV in the liquid-ordered (L o ) and liquid-disordered (L d ) phases of a ternary lipid mixture. This mode is only observed experimentally at momentum transfers greater than 5 nm -1 in the L o system. A similar gapped mode is also observed in all-atom molecular dynamics (MD) simulations of the same mixture, indicating that the simulations accurately represnt the fast, collective dynamics in the L o phase. It’s optical nature and the Q range of the gap together suggest that the observed mode is due to the coupled motion of cholesterol-lipid pairs, separated by several hydrocarbon chains within the membrane plane. Analysis of the simulations provide molecular insight into the origin of the mode in transient, nanoscale substructures of hexagonally packed hydrocarbon chains. This nanoscale hexagonal packing was previously reported based on molecular dynamics simulations and later by NMR measurements. Here, however, the integration of IXS and MD simulations identifies a new signature of the L o substructure in the collective lipid dynamics, thanks to the recent confluence of IXS sensitivity and MD simulation capabilities.

36 MATERIALS SCIENCE↗

Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

Bandler, Simon↗

The Transition-Edge-Sensor Array for the Micro-X Sounding Rocket

The Micro-X sounding rocket program will fly a 128-element array of transition-edge-sensor microcalorimeters to enable high-resolution X-ray imaging spectroscopy of the Puppis-A supernova remnant. To match the angular resolution of the optics while maximizing the field-of-view and retaining a high energy resolution (< 4 eV at 1 keV), we have designed the pixels using 600 x 600 sq. micron Au/Bi absorbers, which overhang 140 x 140 sq. micron Mo/Au sensors. The data-rate capabilities of the rocket telemetry system require the pulse decay to be approximately 2 ms to allow a significant portion of the data to be telemetered during flight. Here we report experimental results from the flight array, including measurements of energy resolution, uniformity, and absorber thermalization. In addition, we present studies of test devices that have a variety of absorber contact geometries, as well as a variety of membrane-perforation schemes designed to slow the pulse decay time to match the telemetry requirements. Finally, we describe the reduction in pixel-to-pixel crosstalk afforded by an angle-evaporated Cu backside heatsinking layer, which provides Cu coverage on the four sidewalls of the silicon wells beneath each pixel.

Eckart, M. E.↗

Imaging X-ray spectrophotometers

A new instrument which combines the good energy resolution of the gas scintillation proportional counter with the high position resolution of the microchannel plate is proposed. A study of the factors which determine the combined energy and position resolution of the new instrument is discussed. Submillimeter position resolution along with good energy resolution (8% fwhm at 6 keV) should be achievable.

Hailey, C. J.↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

The Impact of Crosstalk in the X-IFU Instrument on Athena Science Cases

In this paper we present a first assessment of the impact of various forms of instrumental crosstalk on the science performance of the X-ray Integral Field Unit (X-IFU) on the Athena X-ray mission. This assessment is made using the SIXTE end-to-end simulator in the context of one of the more technically challenging science cases for the XIFU instrument. Crosstalk considerations may influence or drive various aspects of the design of the array of high-count-rate Transition Edge Sensor (TES) detectors and its Frequency Domain Multiplexed (FDM) readout architecture. The Athena X-ray mission was selected as the second L-class mission in ESA's Cosmic Vision 2015–25 plan, with alaunch foreseen in 2028, to address the theme ''Hot and Energetic Universe"1. One of the two instruments on boardAthena is the X-ray Integral Field Unit2 (X-IFU) which is based on an array of ~3800 Transition Edge Sensors (TES's)operated at a temperature of ~90 mK. The science cases pose an interesting challenge for this instrument, as they requirea combination of high energy resolution (2.5 eV FWHM or better), high spatial resolution (5 arcsec or better) and highcount rate capability (several tens of counts per second per detector for point sources as bright as 10 mCrab).The performance at the single sensor level has been demonstrated3, but the operation of such detectors in an array, usingmultiplexed readout, brings additional challenges, both for the design of the array in which the sensors are placed and forthe readout of the sensors. The readout of the detector array will be based on Frequency Domain Multiplexing (FDM)4.In this system of detectors and readout, crosstalk can arise through various mechanisms: on the TES array, neighboringsensors can couple through thermal crosstalk. Detectors adjacent in carrier frequency may suffer from electrical crosstalkdue to the finite width of the bandpass filters, and shared sources of impedance in their signal lines. The signals from theindividual detectors are summed and then amplified by a pair of SQUID amplifiers before being sent to warm front-endelectronics. The transfer function of the SQUID amplifiers is non-linear, which will give rise to higher harmonics ofcarriers and intermodulation products when multiple signal pulses are simultaneously present in the SQUID. Under highcount rate conditions this is another source of crosstalk. The effect of all these crosstalk sources is that parasitic pulseswill appear in the record of a signal pulse which will create a stochastic offset of the measured energy and thus adegradation of the energy resolution.

SIXTE↗

Development of High Resolution Mirrors and Cd-Zn-Te Detectors for Hard X-ray Astronomy

We describe the fabrication and implementation of a high-resolution conical, grazing- incidence, hard X-ray (20-70 keV) telescope. When flown aboard stratospheric balloons, these mirrors are used to image cosmic sources such as supernovae, neutron stars, and quasars. The fabrication process involves generating super-polished mandrels, mirror shell electroforming, and mirror testing. The cylindrical mandrels consist of two conical segments; each segment is approximately 305 mm long. These mandrels are first, precision ground to within approx. 1.0 micron straightness along each conical segment and then lapped and polished to less than 0.5 micron straightness. Each mandrel segment is the super-polished to an average surface roughness of approx. 3.25 angstrom rms. By mirror shell replication, this combination of good figure and low surface roughness has enabled us to achieve 15 arcsec, confirmed by X-ray measurements in the Marshall Space Flight Center 102 meter test facility. To image the focused X-rays requires a focal plane detector with appropriate spatial resolution. For 15 arcsec optics of 6 meter focal length, this resolution must be around 200 microns. In addition, the detector must have a high efficiency, relatively high energy resolution, and low background. We are currently developing Cadmium-Zinc-Telluride fine-pixel detectors for this purpose. The detectors under study consist of a 16x16 pixel array with a pixel pitch of 300 microns and are 1 mm and 2 mm thick. At 60 keV, the measured energy resolution is around 2%.

Ramsey, Brian D.↗

A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources

In recent years much effort has been devoted to the development of large area gas scintillation proportional counters (GSPCs) suitable for use in X-ray astronomy. The paper deals with a low-energy GSPC for use in detecting sub-keV X-rays from cosmic sources. This instrument has a measured energy resolution of 85 eV (FWHM) at 149 eV over a sensitive area of 5 sq cm. The development of imaging capability for this instrument is discussed. Tests are performed on the feasibility of using an arrangement of several phototubes placed adjacent to one another to determine event locations in a large flat counter. A simple prototype has been constructed and successfully operated.

Hamilton, T. T.↗