Effects of Mild Hypobaric Hypoxia on Response From Mild Exercise in NASA Exploration Atmosphere Tests
INTRODUCTION: The NASA Exploration Atmosphere study aims to validate a new prebreathe protocol incorporating an alternate habitat atmosphere of 56.5 kPa (8.2psia), 34% O 2 , and 66% N 2 to control and mitigate decompression sickness risk associated with spaceflight extravehicular activities. This alternate atmosphere results in a mild hypoxic environment (PIO 2 of 128 mmHg) that may influence inhabitant physiological responses to exercise. Therefore, the responses to light exercise in relation to the mild hypobaric hypoxic environment were investigated. METHODS: Eight participants (4M/4F; age=38.3±9.0 yr; weight=76.0±13.1 kg; peak aerobic capacity [VO 2 pk]= 3.1±0.7 L/min) were exposed to a mild hypobaric hypoxic environment for 11 days in NASA’s 20-foot hypobaric chamber at Johnson Space Center. Participants alternated test days between a habitat atmosphere of 56.5 kPA/34% O 2 and simulated 6-hour EVA environment, 29.6 kPa/85% O 2 . Participants completed pre-mission graded VO 2 pk tests on a LODE cycle ergometer with ParvoMedics metabolic analyzer. Submaximal aerobic tests were performed pre and during the mission (10-minutes of exercise at a workload of 40% VO 2 pk).Pre-mission, performed submaximal exercise exposed to a breathing air mixture of, 18% O 2 and balance N 2 , to simulate the mildly hypoxic environment within the 20-foot chamber. Linear mixed models (fixed effect: test day; random effects: subject, age) were performed to determine whether physiological responses (oxygen uptake [VO 2 ], carbon dioxide production [VCO 2 ], ventilation [VE], oxygen saturation [SPO 2 ], heart rate [HR], respiratory exchange ratio [RER]) to submaximal exercise performed within the 20-foot hypobaric chamber every 2 days differed from the pre-mission (18% O 2 ) testing. Results are presented as estimated marginal means with lower and upper confidence limits, with significance set to 0.05. RESULTS AND DISCUSSION: Seven of eight participants completed the chamber study. Mixed models for VO 2 , VCO 2 , SpO 2 , HR, and RER indicated negligible impact of the mild hypoxic chamber environment compared to pre-mission testing (all p>0.05).Results for VE indicated a minor impact of chamber environment compared to pre-mission testing (37.0 L/min [30.8, 43.2]), with increased VE at test day 10 (40.4 L/min [34.2, 46.6]; p= 0.029).The aerobic performance data collected suggests limited physiologic responses to mild exercise when performed at normobaric hypoxia and hypobaric hypoxia.