Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraction chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Rare-earth element fractionation in uranium ore and its U(VI) alteration minerals

We developed a cation exchange chromatography method employing sulfonated polysterene cation resin (DOWEX AG50-X8) in order to separate rare-earth elements (REEs) from uranium-rich materials. The chemical separation scheme is designed to reduce matrix effects and consequently yield enhanced ionization efficiencies for concentration determinations of REEs without significant fractionation using solution mode-inductively coupled plasma mass spectrometry (ICP-MS) analysis. This method was then applied to determine REE abundances in four uraninite (ideally UO 2 ) samples and their associated U(VI) alteration minerals. In three of the samples analyzed, the concentration of REEs for primary uraninite are higher than those for their corresponding secondary uranium alteration phases. The results for U(VI) alteration minerals of two samples indicate enrichment of the light REEs (LREEs) over the heavy REEs (HREEs). This differential mobilization is attributed to differences in the mineralogical composition of the U(VI) alteration. There is a lack of fractionation of the LREEs in the uraninite alteration rind that is composed of U(VI) minerals containing Ca 2+ as the interlayer cation (uranophane and bequerelite); contrarily, U(VI) alteration minerals containing K + and Pb 2+ as interlayer cations (fourmarierite, dumontite) indicate fractionation (enrichment) of the LREEs. Our results have implications for nuclear forensic analyses since a comparison is reported between the REE abundances for the CUP-2 (processed uranium ore) certified reference material and previously determined values for uranium ore concentrate (UOC) produced from the same U deposit (Blind River/Elliott Lake, Canada). UOCs represent the most common form of interdicted nuclear material and consequently is material frequently targeted for forensic analysis. The comparison reveals similar chondrite normalized REE signatures but variable absolute abundances. Based on the results reported here, the latter may be attributed to the differing REE abundances between primary ore and associated alteration phases, and/or is related to varying fabrication processes adopted during production of UOC.

58 GEOSCIENCES↗

Development of field-based separations for the rapid identification of uranium and plutonium

The development of rapid, radioanalytical techniques to separate uranium and plutonium from complex, field samples are needed for the timely and accurate determination of nuclear material origin, and processing activities. Widespread use of nuclear power and technology in the world has increased demands on analytical laboratories from the monitoring of numerous low-level, environmental samples with variable compositions. Environmental sampling has proven to be one of the strongest technical measures for detecting nuclear material and activities. With the increase in sampling demands, new technologies must offer improvements such as automation, high throughput, reproducible chemical separations, short analysis times, and reduced costs to be effective. We have been developing a portable, separations system for uranium (U) and plutonium (Pu) separations based upon selective extraction of target elements using an extraction chromatographic resin which would allow for simple and fast identifcation when coupled with the appropriate sample digestor and detection systems. The microfluidic design minimizes elution volumes and concentrates the elements of interest in a purified stream. Flowsheet development and testing was demonstrated on a single, micro-column system with an acidified, iron, uranium, and plutonium nitrate stream. The recovery of Pu was optimized by examining various reducing agents at different concentrations for rapid, quantitative recovery from the flow-through design. Quantitative recovery and high selectivity of U and Pu was achieved in the appropriate stripping stages and provided purified and concentrated U and Pu streams. The microfluidic system suggests automation in a small, footprint unit while exploiting the in-line processing of extraction chromatographic resins as the primary means of concentrating the radionuclides from the raw acidic feed and separating the elements into purified streams.

Extraction Chromatography↗

Age-dating methodology for 137 Cs ceramic sources

Here, age-dating of 137 Cs ceramic sources is shown to be a viable technology for nuclear forensics investigations. The 137 Cs age-dating method in general, however, could be substantially improved by using radiometric rather than ICP-MS measurement of the 137 Cs isotope and by refining the Cs/Ba separation process. With these improvements, uncertainty in the age of a 60-year-old source decreases from 1.35 to 0.68 y.

137Cs ceramic↗

Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chromatographic separation of americium from europium using bis-2,6-(5,6,7,8-tetrahydro-5,9,9-trimethyl-5,8-methano-1,2,4-benzotriazin-3-yl) pyridine

The separation of americium(III) from europium(III) was achieved utilizing a bis-2,6-(5,6,7,8-tetrahydro-5,9,9-trimethyl-5,8-methano-1,2,4-benzotriazin-3-yl) pyridine (CA-BTP) chromatographic resin. The extraction chromatographic materials were prepared using various concentrations of CA-BTP. This new, hydrolytically stable extractant was impregnated on an inert polymeric support at 40% loading. The uptake of Am(III) and Eu(III) by this material from 0.1 to 4.0 M aqueous HNO 3 solutions was measured. The resulting dry weight distribution ratios, D w , indicated a strong preference for Am(III) with little affinity for Eu(III). These results are similar to recently reported solvent extraction studies indicating a maximum uptake of Am(III) in the 0.5–1.0 M HNO 3 range. The resin preparation, performance, and characterization of the Am/Eu separation are reported herein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of urban debris material on the extraction chromatographic separation of strontium—part I: steel

An incident involving a radiation dispersal device (RDD) would most likely occur in an urban or metropolitan area. However, the majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. 90 Sr is one of the possible radioisotopes that could be used in an RDD. It is therefore important to find efficient and accurate ways to separate it from debris in the area of deployment. Finally, this research demonstrates that the presence of steel in dissolved samples shows no appreciable interference with extraction chromatographic separations. Instead, it indicates that the separation could actually be improved by the presence of the steel constituents.

36 MATERIALS SCIENCE↗

Effects of urban debris material on the extraction chromatographic separation of strontium: Part II: cement and concrete

The majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. However, it is much more likely that an incident involving a radiation dispersal device (RDD) would occur in an urban or metropolitan area. It is unclear if the currently available separation schemes would be effective in such an event. It is therefore important to determine if the current schemes would be adequate, or to find efficient and accurate ways to separate radiological material from urban debris. One important radiological material that could be used in an RDD is 90 Sr. Part I of this work investigated the effects steel had on strontium separations, while this work investigates cement and concrete. This research demonstrates that the individual elements present in a cement and concrete sample matrix can give rise to significant interferences with extraction chromatographic separations. In conclusion, solutions of the constituents mixed in representative ratios; however, show fewer problems

36 MATERIALS SCIENCE↗

Production and isolation of 197m,g Hg

A new procedure has been developed for isolating no-carrier-added 197m,g Hg from 20 to 25 MeV a-particle irradiations of high purity Pt foils. A previously published procedure for isolation of 197m,g Hg from 12 to 15 MeV proton irradiations of Au foils has been further characterized. From these procedures two separate methods have been established to isolate, with high separation factors, 197m,g Hg from Pt to Au target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Improving the separation of strontium and barium with Sr Resin using chelating eluent solutions

Age dating radioactive 137 Cs and 90 Sr sources, which are a potential concern in radiation dispersal devices, can provide evidence for attribution in a nuclear forensic investigation. Precise measurement of the 137 Cs– 137 Ba or 90 Sr– 90 Zr isotope ratio by ICP-MS in tandem with non-linearity and mass-bias data manipulation dramatically increases precision and decreases uncertainty, leaving inadequate chemical separation efficiencies as a major contributor—and in some cases the lead contributor—to uncertainty in age determination. To improve the separation of these isobars before ICP-MS analysis, we evaluated eluents containing EDTA and DTPA chelating agents against previously studied eluents for their ability to achieve complete removal of Sr and Ba from Eichrom Technologies’ Sr Resin. Barium separation efficiencies using 0.05 M EDTA, pH-adjusted 0.05 M EDTA, and pH-adjusted 0.05 M DTPA were found to be 100.9 ± 2.2%, 99.4 ± 0.8%, and 99.3 ± 1.2%, respectively. Strontium separation efficiencies using 0.05 M disodium EDTA and 0.05 M potassium EDTA were determined to be 100.14 ± 0.53% and 100.19 ± 0.97% respectively. Furthermore, these results demonstrate that eluents containing chelating agents out-perform previously studied eluent solutions at removing barium and strontium from Sr Resin.

07 ISOTOPE AND RADIATION SOURCES↗

Improving the recovery of Ba from Sr Resin columns using chelating agents

Age dating of Cs-137 sources necessitates the accurate and precise quantification of the isotope Ba-137. In previous efforts to determine the age of Cs-137 source material, variation in Ba recovery was the largest source of uncertainty. This work investigates the use of several common chelating agents (EDTA, CDTA, DTPA, and NTA) to strip barium from Sr Resin columns quantitatively in an effort to improve the reproducibility of the separation. Batch studies showed conditions in which CDTA, EDTA, and NTA may suppress the retention of Ba on the column. Follow-up column studies showed excellent removal of barium from the column with quantitative recovery in the appropriate elution fraction. Our report builds upon previous studies and establishes additional chelating agents that could be used in an age dating separation procedure

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction of gold, mercury and lead on CL resin in HCl

The uptake behavior of 197 mHg, 194 Au and 212 Pb in HCl on CL resin (Triskem) was studied. The extraction of mercury and gold is high (D w > 5,000) at all concentrations of HCl, with a maximum extraction of gold at 4 M HCl (D w ~ 53,000) and maximum extraction of mercury at 0.01 M HCl (D w ~ 44,000). Lead has moderate uptake on CL resin (D w ~ 100) from lower concentrations of HCl (0.001 to 0.05 M) and no uptake on the resin in concentrations ≥ 0.4 M. The uptake kinetics are similar for all three isotopes with high weight distribution ratios (>1,000 for 197 mHg, 194 Au and > 100 for 212 Pb) in ~ 30 s and equilibrium established at ~ 5 min. A column study was performed to demonstrate that 197m Hg, 194 Au and 212 Pb could be retained on CL resin in dilute HCl and 212 Pb eluted in 1 M HCl with no detectable 197m Hg or 194 Au. Elution of 197 mHg and 194 Au was performed with concentrated HNO 3 , but with significant losses to the column, particularly for 194 Au.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction of gold, mercury, and lead with TEVA resin from HCl and HNO 3

The extraction behavior of 212 Pb, 197m Hg, and 194 Au on TEVA resin in HCl and HNO 3 solutions was studied with batch uptake, kinetics, and column studies. The uptake of mercury and gold was extremely high from HCl solutions, with maximum k’ >80,000 for both elements. The uptake of mercury was lower in HNO3 than HCl with a maximum k’ of ~ 8,000 in 0.02 M HNO 3 and decreasing uptake at higher concentrations of HNO3, which agrees well with previous work. The batch uptake of gold in HNO 3 was not measured, as it had been reported previously. The uptake of lead on TEVA resin in HCl was low with a maximum k’ of only ~ 90 in 1 M HCl. The uptake of lead in HNO 3 was negligible. The uptake kinetics of gold and mercury were characterized in HCl and HNO 3 solutions and high uptake was seen after ~ 60 s for both elements. Column separations of 212 Pb, 197m Hg, and 194 Au on TEVA resin from HCl and HNO 3 solutions are reported with high yields of mercury and lead, but with high losses of gold, which is retained on the resin. A rapid, high yield separation of 197m Hg from irradiated gold foils is presented with yields of ~ 100% for both elements and a total separation time of < 2 h.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction of radium and actinium with dibenzo-21-crown-7 resin and Rose Bengal

The extraction of 224 Ra and 228 Ac with dibenzo-21-crown-7 resin was studied in solutions with Rose Bengal and identical solutions without Rose Bengal (blanks) from pH 3 to 12. Batch studies demonstrated that actinium is extracted at high pH (> 10) from both solutions but with a significantly higher extraction from the Rose Bengal solutions (maximum extraction ~ 60,000) than the blank solutions (maximum extraction ~ 2,000). In the Rose Bengal solutions, there was a weak extraction of actinium at lower pH (4–10) as well. There was no uptake of radium from the blank solutions, and a weak extraction at all pH levels from the Rose Bengal solutions. Kinetics studies were performed for actinium only, as radium had no significant extraction. Two column studies are demonstrated for the separation of radium from actinium. These separations are moderately effective with ~ 78% of the actinium recovered with no detectable radium.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiochronometric analysis of an historic Cs-137 activity standard

In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction of selenium and arsenic with TOA-impregnated XAD-2 resin from HCl

Here the uptake of 75 Se and 73 As on trioctylamine-impregnated resin from HCl solutions was studied with batch uptake, kinetics, and column studies. Selenium-75 extracts well (D w ~ 900) at high HCl concentrations (≥ 10 M) with and no extraction of 73 As at any HCl concentration. The uptake kinetics were slow with low extraction (D w < 100) for time periods ≤ 15 min and no clear equilibrium achieved even after 24 h. Column studies were performed to characterize the separation of 75 Se and 73 As; 75Se is retained from conc. HCl while arsenic is eluted with high yields and high radiopurity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synergistic extraction of rare earth elements, actinium, americium, and barium with TTA and Pb resin from acetate buffer solutions

The uptake behavior of 88 Y, 140 Ba, 140 La, 141 Ce, 152 Eu, 228 Ac, and 241 Am was studied with batch uptake, kinetics and column studies in a synergistic extraction system with Pb resin and 2-thenoyltrifuoroacetone in acetate-ethanol solutions. The k' values are very high (>10,000) at near neutral pH (~5 to 6) for all of the radioisotopes studied. The kinetics are reasonably fast for column separations, though the uptake rate is dependent on the concentration of 2-thenoyltrifuoroacetone. Column studies were performed to demonstrate the separation of the trivalent actinides and lanthanides from barium and common fssion products ( 99 Mo, 103 Ru).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Uptake of arsenic and selenium on iron-doped Pb resin

We report the uptake of the radioisotopes 73 As and 75 Se was characterized on Fe 3+ -doped Pb resin (Eichrom Technologies) from pH 1 to 12. There is good uptake of arsenic and selenium over a wide pH range (~ 1 to 10) with a decrease only at high pH (~ 12). Column experiments were performed to demonstrate the separations of these elements from solutions with near neutral pH values (~ 6 to 8) with high yields and high radiopurity. These separations may be relevant for a wide variety of applications especially isotope harvesting research.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗