Search NASA⌕ Search

SEARCH · Search NASA

Results for “FABRY-PEROT SPECTROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigation of thermospheric winds relative to space station orbital altitudes

An investigation of thermospheric winds, relative to the space station orbital altitudes, was made in order to provide information that is useful in an environmental disturbance assessment. Current plans are for this low Earth orbiting facility to orbit at an inclination of 28.5 deg. The orbital altitudes were not yet defined due to the evolutionary configuration of the Space Station. The upper and lower bounds of the orbital altitudes will be based on constraints set by the drag and expected orbital decay and delivery altitude capability of the Shuttle. The orbital altitude will be estimated on the order of 500 km. Neutral winds in the region from about 80 to 600 km which were derived from satellite drag data, Fabry-Perot interferometers, sounding rockets, ground-based optical Doppler techniques, incoherent scatter radar measurements from Millstone Hill combined with the mass spectrometer and lithium trail neutral wind measurements are examined. The equations of motion of the low Earth orbiting facility are also discussed.

Susko, M.↗

Neutral winds in the polar thermosphere as measured from Dynamics Explorer

Remote sensing measurements of the meridional thermospheric neutral wind using the Fabry-Perot Interferometer on Dynamics Explorer have been combined with in-situ measurements of the zonal component using the Wind and Temperature Spectrometer on the same spacecraft. The two data sets with appropriate spatial phasing and averaging determine the vector wind along the track of the polar orbiting spacecraft. A study of fifty-eight passes over the Southern (sunlit) pole has enabled the average Universal Time dependence of the wind field to be determined for essentially a single solar local time cut. The results show the presence of a 'back-ground' wind field driven by solar EUV heating upon which is superposed a circulating wind field driven by high latitude momentum and energy sources.

Killeen, T. L.↗

KWIC: A Widefield Mid-Infrared Array Camera/Spectrometer for the KAO

The Kuiper Widefield Infrared Camera (KWIC) is an imaging spectrometer designed for use on the Kuiper Airborne Observator between 18 and 40 microns. The spectral resolution achieving devices are two fully tunable and scanning cryogenic Fabry-Perot interferometers that employ free standing metal mesh as the reflective surfaces. The detective device is a 128 x 128 pixel Si:Sb BIB array manufactured by Rockwell/Boeing for the SIRTF project. The plate scale for KWIC (one pixel subtends 2.73" x 2.73") was chosen so as to more than fully sample the KAO beam (approximately 9" at 31.5 microns), to enable effective image restoration techniques to be applied. Even so, KWIC has a rather large (5.8' x 5.8') field of view. KWIC has both high and low spectral resolution modes that are interchangeable in a few minutes time in flight on the KAO. The high resolution (R = lambda/(delta)lambda = 1000 to 6000) mode is suitable for detecting weak lines in the presence of strong continuum for Galactic sources, and for resolving broad extragalactic lines. The low resolution (R approximately 30 to 100) mode is suitable for imaging in the thermal dust continuum.

Stacey, Gordon J.↗

SAFIRE: A Far-Infrared Imaging Spectrometer for SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 micrometers-655 micrometers with spectral resolving power of approx. 1500 (200km/s). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background-limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors. An engineering prototype of SAFIRE with a small but cutting edge detector array will be available for use during the initial SOFIA operations; further expansion to larger format arrays will be incorporated during SAFIRE's lifetime.

Shafer, Richard A.↗

High resolution 1-20 micron imaging of the nuclear environment of NGC 1068

We present new mid-infrared continuum and near-IR line images of the nuclear environment of the nearby (14 Mpc) Seyfert 2 galaxy NGC 1068. The 8, 10, and 19 micron data were measured with our new mid-IR array camera, MIRACLE, at UKIRT in Nov. 1991 while our images of the H2 2.121 micron and (Fe 2) 1.64 micron lines were obtained with FAST, the MPE imaging spectrometer, at the 4.2m William Herschel Telescope in Aug. 1991. The MIRACLE data were imaged through narrow band (lambda/delta(lambda) greater than or equal to 50) filters whereas FAST incorporates a Fabry-Perot etalon (lambda/delta(lambda) greater than or equal to 950).

Cameron, M.↗

The LPL radial accelerometer

The LPL stellar accelerometer, an interferometrically calibrated spectrometer, is described. Particular attention is given to light feed, image scrambling, and interferometric wavelength calibration. Changes in radial velocity are inferred from changes in the relative intensities of starlight transmitted through the Fabry-Perot.

Mcmillan, R. S.↗

Search for planets by spectroscopic methods

Spectroscopic means of detecting the motion of a star around a star-planet barycenter are considered. The precision of such an observation, which requires a radial velocity error of not more than 5 m/sec, is discussed in relation to the spectral resolutions of the detectors utilized. The University of Arizona radial velocity spectrometer is then presented, with particular attention given to the location of the absorption cell in a beam of light from an incandescent bulb, high-accuracy wavelength calibration involving the use of a Fabry-Perot interferometer in front of an echelle spectrograph, and future plans for the use of light reflected from a Fabry-Perot etalon to improve transmittance. On the basis of these techniques, it is expected that radial velocities with accuracies sufficient for the detection of extrasolar planets will be obtained.

Serkowski, K.↗

Neutral winds in the polar thermosphere as measured from Dynamics Explorer

Possibilities for experimental investigations related to the study of the dynamics of the thermosphere have been markedly improved by the new instrumentation deployed on the Dynamics Explorer Satellite (DE). The Fabry-Perot interferometer (FPI) on DE measures altitude profiles of the meridional component of the neutral wind below the spacecraft by remotely sensing the Doppler shift of the thermospheric O(1D). The Wind and Temperature Spectrometer (WATS) measures the in situ zonal component of the neutral wind by measuring the angle of arrival of the beam of neutral atoms entering the aperture to a mass spectrometer. A description is provided of data handling procedures, and the first results obtained by combining the data sets from the two instruments are presented. Acquisition and determination of neutral wind vectors from the remote (FPI) and in-situ (WATS) measurements requires careful handling of the data to ensure that the two components relate to the same volume of space.

Killeen, T. L.↗

Thermal Water Vapor Emission from Shocked Regions in Orion

Using the Long Wavelength Spectrometer on board the Infrared Space Observatory, we have observed thermal water vapor emission from a roughly circular field of view approximately 75" in diameter centered on the Orion BN-KL region. The Fabry-Perot line strengths, line widths, and spectral line shifts observed in eight transitions between 71 and 125 micron show good agreement with models of thermal emission arising from a molecular cloud subjected to a magnetohydrodynamic C-type shock. Both the breadth and the relative strengths of the observed lines argue for emission from a shock rather than from warm quiescent gas in the Orion core. Although one of the eight transitions appears anomalously strong and may be subject to the effects of radiative pumping, the other seven indicate an H2O/H2 abundance ratio on the order of 5 x 10(exp -4) and a corresponding gas-phase oxygen-to-hydrogen abundance ratio on the order of 4 x 10(exp -4). Given current estimates of the interstellar, gas-phase, oxygen and carbon abundances in the solar vicinity, this value is consistent with theoretical shock models that predict the conversion into water of all the gas-phase oxygen that is not bound as CO. The overall cooling provided by rotational transitions of H2O in this region appears to be comparable to the cooling through rotational lines of CO but is an order of magnitude lower than cooling through H2 emission. However, the model that best fits our observations shows cooling by H2O and CO dominant in that portion of the postshock region where temperatures are below approximately 800 K and neither vibrational nor rotational radiative cooling by H2 is appreciable.

Harwitt, Martin↗

Stratospheric OH measurements with a far-infrared limb observing spectrometer

The Far-Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure the hydroxyl radical (OH) and other chemical species in the upper atmosphere using limb emission in the far-infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain high spectral resolution near 101/cm and 118/cm. The instrument concept, calibration, and atmospheric measurements are discussed.

Pickett, H. M.↗

Multiplex Fabry-Perot interferometer

Attention is given to a Fabry-Perot interferometer (FPI) technique in which one of the etalon plates is moved over a large optical distance while the other remains fixed, thus exploiting the multiplex advantage of the instrument. This technique involves the application of Fourier-transform spectrometer to the multiple harmonics passing through the FPI etalon. It is shown that the multiplex FPI acts as several Michelson interferometers working at the same time, over the same spectral interval, and at different spectral resolutions. A high spectral resolution has been obtained over a large wavenumber interval, while the advantage of a reasonable scan length has been retained.

Hays, Paul B.↗

Construction and Calibration of a Difference Frequency Laser Spectrometer and New THZ Frequency Measurements of water and Ammonia

A three laser system based on 852nm DBR lasers has been constructed and used to generate radiation in the 750 GHz to 1600 GHz frequency region. The system works by locking two of the three lasers to modes of an ultra low expansion Fabry-Perot cavity. The third laser is offset locked to one of the cavity locked lasers with conventional microwave techniques. The signal from the offset laser and the other cavity locked laser are injected into a Master Oscillator Power Amplifier (MOPA), amplified and focused on a low temperature grown GaAs photomixer, which radiates the difference frequency. The system has been calibrated with molecular lines to better than one part in 10(exp 7). In this paper we present the application of this system to the v(sub 2) in inversion band of Ammonia and the ground and v(sub 2) states of water. A discussion of the system design, the calibration and the new spectral measurements will be presented.

Pearson, J. C.↗

Escape of suprathermal O(+) ions in the polar cap

Instruments on board the Dynamics Explorer (DE) 1 and 2 spacecraft have been used to investigate the characteristics of a very low-energy (less than 10 eV) outflow of O(+) ions at high altitudes over the polar cap. The measured O(+) outflow has a relatively high Mach number (2-6) and a flux of about 2 x 10 to the 8th/(sq cm s). A statistical study using 50 orbits of retarding ion mass spectrometer data indicates that the outflows occur during active magnetic conditions, lasting for several hours over large areas of the polar cap. The observations are then discussed and analyzed in a framework based on polar wind models with particular attention paid to the new information obtained by the DE 2 Fabry-Perot interferometer, and the impact these flows have on the composition of the magnetosphere. The observed suprathermal outflow of O(+) suggests a scenario requiring both significant compositional changes in the high latitude thermosphere and significant heating of the ions and electrons in the topside ionoshpere.

Waite, J. H., Jr.↗

Alternative Method for the Thermospheric Atomic Oxygen Density Determination

Atomic oxygen density in the upper thermosphere (approximately 300 km) can be calculated using ground based incoherent scatter radar and Fabry-Perot interferometer measurements. Burnside et al. was the first to try this method, but Buonsanto et al. provided an extensive treatment of the method in 1997. This paper further examines the method using 46 nights of data collected over six years and the latest information on the oxygen collision frequency. The method is compared with the MSIS (Mass Spectrometer Incoherent Scatter)-86 atomic oxygen prediction values, which are based upon in situ rocket born and satellite measurements from the 70s to the mid-80s. In general, the method supports the MSIS-86 model, but indicates several areas of discrepancy. Furthermore, no direct correlation is found between the geomagnetic conditions and the difference between the method and MSIS-86 predictions.

Bennett, A. C.↗

Fabry-Perot interferometer development for rocket engine plume spectroscopy

This paper describes a new rugged high-resolution Fabry-Perot interferometer (FPI) designed for rocket engine plume spectroscopy, which is capable of detecting spectral signatures of eroding engine components during rocket engine tests and/or flight operations. The FPI system will make it possible to predict and to respond to the incipient rocket engine failures and to indicate the presence of rocket components degradation. The design diagram of the FPI spectrometer is presented.

Bickford, R. L.↗

Halogen Occultation Experiment (HALOE) optical filter characterization

The Halogen Occultation Experiment (HALOE) is a solar occultation experiment that will fly on the Upper Atmosphere Research Satellite to measure mixing ratio profiles of O3, H2O, NO2, NO, CH4, HCl, and HF. The inversion of the HALOE data will be critically dependent on a detailed knowledge of eight optical filters. A filter characterization program was undertaken to measure in-band transmissions, out-of-band transmissions, in-band transmission shifts with temperature, reflectivities, and age stability. Fourier Transform Infrared Spectrometers were used to perform measurements over the spectral interval 400/cm to 6300/cm (25 micrometers to 1.6 micrometers). Very high precision (0.1 percent T) in-band measurements and very high resolution (0.0001 percent T) out-of-band measurements have been made. The measurements revealed several conventional leaks at 0.01 percent transmission and greatly enhanced (1,000) leaks to the 2-element filters when placed in a Fabry-Perot cavity. Filter throughput changes by 5 percent for a 25 C change in filter temperature.

Harvey, Gale A.↗

Infrared Space Observatory Observations of Far-Infrared Rotational Emission Lines of Water Vapor Toward the Supergiant Star VY Canis Majoris

We report the detection of numerous far-infrared emission lines of water vapor toward the supergiant star VY Canis Majoris. A 29.5-45 micron grating scan of VY CMa, obtained using the Short-Wavelength Spectrometer (SWS) of the Infrared Space Observatory at a spectral resolving power lambda/delat.lambda of approximately 2000, reveals at least 41 spectral features due to water vapor that together radiate a total luminosity of approximately 25 solar luminosity . In addition to pure rotational transitions within the ground vibrational state, these features include rotational transitions within the (010) excited vibrational state. The spectrum also shows the (sup 2)product(sub 1/2) (J = 5/2) left arrow (sup 2)product(sub 3/2) (J = 3/2) OH feature near 34.6 micron in absorption. Additional SWS observations of VY CMa were carried out in the instrument's Fabry-Perot mode for three water transitions: the 7(sub 25)-6(sub 16) line at 29.8367 micron, the 4(sub 41)-3(sub 12) line at 31.7721 micron, and the 4(sub 32)-3(sub 03) line at 40.6909 micron. The higher spectral resolving power lambda/delta.lambda of approximately 30,000 thereby obtained permits the line profiles to be resolved spectrally for the first time and reveals the "P Cygni" profiles that are characteristic of emission from an outflowing envelope.

Neufeld, David A.↗

Optical design of the ATMOS Fourier transform spectrometer

The optical system design of the ATMOS Fourier transform spectrometer to be operated from Spacelab for the measurement of stratospheric trace molecules is described. The design contains features which can achieve the required fringe contrast of 80% and spectral resolution of 0.02/cm over a spectral range of 2-16 microns. In particular, the design is based on the following features which alleviate the usual requirements for alignment precision: (1) 'cat's eye' mirror configuration in the two arms of the interferometer for retroreflection stability, (2) tilt-compensated system of beamsplitter, compensator, and fold mirrors for wavefront directional stability, (3) paraboloidal 'cat's eye' primary mirror for wavefront stability against shear, (4) rotatable compensator for matching chromatic dispersion, and (5) wedged refractive components to avoid channel spectra due to the Fabry-Perot effect.

Abel, I. R.↗