Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLAME SPRAYING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Observations of severe in-flight environments on airplane composite structural components

The development of relatively inexpensive, highly sophisticated avionics systems makes it now possible for general aviation aircraft to fly under more severe weather conditions than formerly. Increased instrument flying increases exposure of aircraft to potentially severe thunderstorm activity such as high rain rates, hail stones, and lightning strikes. In particular, the effects of lightning on aircraft can be catastrophic. Interest in aircraft lightning protection has been stimulated by the introduction of advanced composites as an aircraft structural material. The present investigation has the objective to report experiences with three composite components which have flown in thunderstorms, taking into account three F-106B composite fin caps. The only visible lightning strike damage to a flame sprayed aluminum coated glass/epoxy fin cap was a small area of the aluminum which was burned. Visible lightning strike damage to a Kevlar/epoxy fin cap was limited to the exterior ply of aluminum coated glass fabric. In the case of a graphite/epoxy fin cap, lightning currents could be conducted.

Howell, W. E.↗

Target reflectance measurements for calibration of lidar atmospheric backscatter data

Wavelength and angular dependence of reflectances and depolarization in the 9-11 micron region are reported for four standard targets: flowers of sulfur, flame-sprayed aluminum, 20-grit sandblasted aluminum, and 400-grit silicon carbon sandpaper. Measurements are presented and compared using a CW CO2 grating-tunable laser in a laboratory backscatter apparatus, an integrating sphere, and a coherent pulsed TEA-CO2 lidar system operating in the 9-11 micron region. Reflectance theory related to the use of hard targets to calibrate lidar atmospheric backscatter data is discussed.

Kavaya, M. J.↗

Measuring Metal Thickness With an Electric Probe

Thickness of metal parts measured from one side with aid of Kelvin probe. Method developed for measuring thickness of end plate on sealed metal bellows from outside. Suitable for thicknesses of few thousandth's of inch (few hundred micrometers). Method also used to determine thickness of metal coatings applied by sputtering, electroplating, and flame spraying.

Shumka, A.↗

Development of a strain/temperature gauge and attachment system for use on carbon composites at elevated temperature

The difficulties encountered when instrumenting solid rocket motors for acquiring strain data are reviewed, emphasizing the strong temperature dependence due to apparent strain effects. The development of a strain/temperature gage to overcome some of these problems is discussed. This gage is designed to produce low apparent strain when attached to a carbon-carbon substrate. Characterization and performance data for gages attached with ceramic cement to carbon-carbon tensile coupons are presented, and the effect of a flame-sprayed installation process is discussed.

Lanius, S. J.↗

In-flight environmental effects on airplane composite vertical fin caps

The NASA-Langley Storm Hazards Program has given attention to the effects of severe in-flight weather environments on composite structures, using an instrumented F-106B in storm penetration experiments. The vertical fin cap was chosen for the study of lightning strike attachments on composite structures of four different types: (1) glass/epoxy with flame-sprayed aluminum; (2) Kevlar/epoxy with aluminized glass cloth; (3) graphite-epoxy without lightning protection; and (4) unprotected graphite-epoxy with electrical isolation from the rest of the aircraft structure. Flight test results are evaluated.

Howell, William E.↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 800 C

A temperature compensated static strain gage, which is fabricated from palladium-13w/o chromium (Pd13Cr) alloy and a platinum (Pt) compensator, is being developed and was tested over a temperature range to 800 C at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 800 C than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4w/o zirconia overcoating. Test results to 800 C indicate apparent strain variations of less than 300 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. Apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

A resistance strain gage with repeatable apparent strain to 800 C

Experimental PdCr temperature-compensated resistance static-strain gages are described. The gages are developed in both fine-wire and thin-film forms. It is found that a PdCr wire strain gage coated with a flame-sprayed mixture of alumina and 4 wt pct zirconia demonstrates the smallest variation in and the best repeatability of apparent strain among the existing gages used at temperatures up to 800 C. Results of preliminary tests indicate uncompensated uncoated thin-film gages have potential usefulness at temperatures up to 1000 C.

Lei, J.-F.↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 1500 F

A temperature compensated static strain gauge, which is fabricated from Pd13Cr alloy and a Pt compensator, is being developed and has been tested over a temperature range to 1500 F at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 500 F than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4 wt pct zirconia overcoating. Test Results to 1500 F indicate apparent strain variations of less than 250 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. The apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Numerical studies of dilute and dense spray characteristics

Several issues involving the improvement of physical submodels and the computational efficiency in modeling dilute and dense spray combustion are discussed. First, the implementations of a dispersion width approach accounting for turbulent dispersion within each computational parcel is discussed. This is essentially a statistical transport model and the testings of this model confirm the capability of accurately representing dispersion in nearly-homogeneous and inhomogeneous turbulent flows with improved efficiency over the delta function stochastic separated flow model. To account for the dense spray effects, an existing drop collision and coalescence model and a Taylor analogy breakup (TAB) model were employed. These models were incorporated into a state-of-the-art multiphase all-speed transient flow solution procedure. Several examples including nonevaporating, evaporating, and burning dense spray cases were studied. The numerical results show reasonably good comparisons with available experimental data in terms of spray penetration, drop sizes, and overall configuration of a spray flame.

Kim, Y. M.↗

More About High-Temperature Resistance Strain Gauges

Two reports present additional information on electrical-resistance strain gauges described in "High-Temperature Resistance Strain Gauges" (LEW-15379). For protection against oxidation at high temperatures, gauges covered, by flame spraying, with coats of alumina containing up to 1 weight percent of yttria or, perferably, containing 4 to 6 weight percent of zirconia.

Englund, D. R.↗

Development of advanced diagnostics for characterization of burning droplets in microgravity

Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel droplet diameter, droplet regression rate, and the droplet internal temperature profiles or gradients at very high data rates in microgravity experiments.

Sankar, Subramanian↗

Comparison Testings between Two High-temperature Strain Measurement Systems

An experimental evaluation was conducted at NASA Lewis Research Center to compare and contrast the performance of a newly developed resistance strain gage, the PdCr temperature-compensated wire strain gage, to that of a conventional high-temperature extensometry. The evaluation of the two strain measurement systems was conducted through the application of various thermal and mechanical loading spectra using a high-temperature thermomechanical uniaxial testing system equipped with quartz lamp heating. The purpose of the testing was not only to compare and contrast the two strain sensors but also to investigate the applicability of the PdCr strain gage to the testing environment typically employed when characterizing the high-temperature mechanical behavior of structural materials. Strain measurement capabilities to 8OO C were investigated with a nickel base superalloy IN100 substrate material, and application to titanium matrix composite (TMC) materials was examined with the SCS-6/Ti-15-3 08 system. PdCr strain gages installed by three attachment techniques, namely, flame spraying, spot welding and rapid infrared joining were investigated.

Lei, J.-F.↗

Enhancement of Nucleate Boiling Heat Flux on Macro/Micro-Structured Surfaces Cooled by Multiple Impinging Jets

An experimental investigation of nucleate boiling heat transfer from modified surfaces cooled by multiple in-line impinging circular jets is reported and found to agree with single jet results. A copper block is heated from the back by two electrical arcs, and cooled on the opposite side by three identical liquid jets of distilled water at subcoolings of 25 C 50 C and 77 C and Freon 113 at 24 C subcooling. Liquid flow rates are held constant at 5, 10, and 15 GPH for each of the three jets with jet velocities ranging from 1.4 m/s to 1 1.2 m/s and jet diameters from 0.95 mm to 2.2 mm. To increase the maximum heat flux (CHF) and heat removal rate, the boiling surface was modified by both macro and micro enhancements. Macro modification consists of machined radial grooves in the boiling surface arranged in an optimally designed pattern to allow better liquid distribution along the surface. These grooves also reduce splashing of liquid droplets, and provide 'channels' to sweep away bubbles. Micro modification was achieved by flame spraying metal powder on the boiling surface, creating a porous, sintered surface. With the addition of both micro and macro structured enhancements, maximum heat flux and nucleate boiling can be enhanced by more than 200%. Examination of each surface modification separately and together indicates that at lower superheats, the micro structure provides the enhanced heat transfer by providing more nucleation sites, while for higher superheats the macro structure allows better liquid distribution and bubble removal. A correlation is presented to account for liquid subcoolings and surface enhancements, in addition to the geometrical and fluid properties previously reported in the literature.

Kugler, Scott Lee↗

High-Temperature, Thin-Film Strain Gages Improved

Conventional resistance strain gage technology uses "bonded" strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow. The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of minimally intrusive surface strain measurements and give highly repeatable readings with low drift at temperatures from ambient to 1100 C. This is a 300 C advance in operating temperature over the PdCr wire gage and a 500 C advance over commercially available gages made of other materials.

Source record↗

High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approximately 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding.

Source record↗

LSPRAY: Lagrangian Spray Solver for Applications With Parallel Computing and Unstructured Gas-Phase Flow Solvers

Sprays occur in a wide variety of industrial and power applications and in the processing of materials. A liquid spray is a phase flow with a gas as the continuous phase and a liquid as the dispersed phase (in the form of droplets or ligaments). Interactions between the two phases, which are coupled through exchanges of mass, momentum, and energy, can occur in different ways at different times and locations involving various thermal, mass, and fluid dynamic factors. An understanding of the flow, combustion, and thermal properties of a rapidly vaporizing spray requires careful modeling of the rate-controlling processes associated with the spray's turbulent transport, mixing, chemical kinetics, evaporation, and spreading rates, as well as other phenomena. In an attempt to advance the state-of-the-art in multidimensional numerical methods, we at the NASA Lewis Research Center extended our previous work on sprays to unstructured grids and parallel computing. LSPRAY, which was developed by M.S. Raju of Nyma, Inc., is designed to be massively parallel and could easily be coupled with any existing gas-phase flow and/or Monte Carlo probability density function (PDF) solver. The LSPRAY solver accommodates the use of an unstructured mesh with mixed triangular, quadrilateral, and/or tetrahedral elements in the gas-phase solvers. It is used specifically for fuel sprays within gas turbine combustors, but it has many other uses. The spray model used in LSPRAY provided favorable results when applied to stratified-charge rotary combustion (Wankel) engines and several other confined and unconfined spray flames. The source code will be available with the National Combustion Code (NCC) as a complete package.

Raju, Manthena S.↗

NASA Tech Briefs, May 2007

Topics include: Noise-Canceling Helmet Audio System; Program Analyzes Spacecraft/Ground Radio Links; Two-Way Communication Using RFID Equipment and Techniques; Six-Message Electromechanical Display System; Scanning Terahertz Heterodyne Imaging Systems; Master Clock and Time-Signal-Distribution System; Synchronous Phase-Resolving Flash Range Imaging; Integrated Radial Probe Transition From MMIC to Waveguide; Bar-Code System for a Microbiological Laboratory; MMIC Amplifier Produces Gain of 10 dB at 235 GHz; Mapping Nearby Terrain in 3D by Use of a Grid of Laser Spots; Digital Beam Deflectors Based Partly on Liquid Crystals; Narrow-Band WGM Optical Filters With Tunable FSRs; Better Finite-Element Analysis of Composite Shell Structures; Computing Spacecraft-Pointing Vectors for Limb Tracking; Enhanced Master Controller Unit Tester; Rover Graphical Simulator; Increasing Durability of Flame-Sprayed Strain Gauges; Multifunctional, High-Temperature Nanocomposites; Multilayer Impregnated Fibrous Thermal Insulation Tiles; Radiation-Shielding Polymer/Soil Composites; Film/Adhesive Processing Module for Fiber-Placement Processing of Composites; Fabrication of Submillimeter Axisymmetric Optical Components; Electrochemical Disposal of Hydrazines in Water; Statistical Model of Evaporating Multicomponent Fuel Drops; Resistively Heated SiC Nozzle for Generating Molecular Beams; Compact Packaging of Photonic Millimeter-Wave Receiver; Diffractive Combiner of Single-Mode Pump Laser-Diode Beams; Wide-Band, High-Quantum-Efficiency Photodetector; A Robustly Stabilizing Model Predictive Control Algorithm; Modeling Evaporation of Drops of Different Kerosenes; Development of Vapor-Phase Catalytic Ammonia Removal System; Several Developments in Space Tethers; Design Concept for a Nuclear Reactor-Powered Mars Rover; Formation-Initialization Algorithm for N Spacecraft; and DNSs of Multicomponent Gaseous and Drop-Laden Mixing Layers Achieving Transition to Turbulence.

Source record↗

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

H S Alpert↗