Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Transonic rotor flow-measurement technique using holographic interferometry

Holographic interferometry is used to record interferograms of the flow near a hovering transonic rotor blade. A pulsed ruby laser recorded 40 interferograms with a 2 ft dia. view field near the model rotor blade tip operating at a tip Mach number of 0.90. The experimental procedure is presented and example interferograms recorded in the rotor's tip path plane. In addition, a method currently being pursued to obtain quantitative flow information using computer assisted tomography (CAT) with the holographic interferogram data, is outlined.

Kittleson, John K.↗

Particle-fluid interaction corrections for flow measurements with a laser Doppler flowmeter

A discussion is given of particle lags in mean flows, acoustic oscillations at single frequencies and in turbulent flows. Some simplified cases lead to exact solutions. For turbulent flows linearization of the equation of motion after assuming the fluid and particle streamlines coincide also leads to a solution. The results show that particle lags are a function of particle size and frequency of oscillation. Additional studies are necessary to evaluate the effect of turbulence when a major portion of the energy is concentrated in small eddies.

Berman, N. S.↗

Rayleigh Scattering for Measuring Flow in a Nozzle Testing Facility

A molecular Rayleigh-scattering-based air-density measurement system was built in a large nozzle-and-engine-component test facility for surveying supersonic plumes from jet-engine exhaust. A molecular Rayleigh-scattering-based air-density measurement system was built in a large nozzle-and-enginecomponent test facility for surveying supersonic plumes from jet-engine exhaust

Gomez, Carlos R.↗

Pipe flow measurements of turbulence and ambiguity using laser-Doppler velocimetry

The laser-Doppler ambiguities predicted by George and Lumley (1973) have been verified experimentally for turbulent pipe flows. Experiments were performed at Reynolds numbers from 5000 to 15,000 at the center line and near the wall. Ambiguity levels were measured from power spectral densities of FM demodulated laser signals and were compared with calculations based on the theory. The turbulent spectra for these water flows after accounting for the ambiguity were equivalent to hot-film measurements at similar Reynolds numbers. The feasibility of laser-Doppler measurements very close to the wall in shear flows is demonstrated.

Berman, N. S.↗

Flow measurements of an airfoil with deflected spoiler

Spoilers are used as an effective control surface in various stages of flight. The steady and unsteady flow characteristics change with incidence and spoiler angle. An experimental investigation is undertaken to understand the flow phenomena. Typical boundary layer and wake profiles at various incidences and spoiler angles are presented and discussed. A laminar separation is observed at low incidence and high spoiler angle. At incidence, a turbulent boundary layer develops and separation point moves downstream. Generally the wake profiles are asymmetric. When different length scales are used, the profiles become self-similar and symmetric. The importance of laser velocimetry in the reverse flow region is demonstrated by comparing the preliminary LDV measurements with the hot-wire results.

Lee, C. S.↗

Internal flow measurements of the SSME fuel preburner injector element using real time neutron radiography

Due to observations of unsteady flow in the Space Shuttle Main Engine fuel preburner injector element, several flow studies have been performed. Real time neutron radiography tests were recently completed. This technique provided real time images of MiL-c-7024 and Freon-22 flow through an aluminum liquid oxygen post model at three back pressures (0, 150, and 545 psig) and pressure drops up to 1000 psid. Separated flow appeared only while operating at back pressures of 0 and 150 psig. The behavior of separated flow was similar to that observed for water in a 3x acrylic model of the LOX post. On the average, separated flow appeared to reattach near the exit of the post when the ratio of pressure drop to supply pressure was about 0.75.

Lindsay, John T.↗

A real time interferometry system for unsteady flow measurements

A simple real-time interferometer system was developed for use in dynamic stall and other unsteady flow research at compressible flow speeds. A conventional schlieren system was modified to operate as a point diffraction interferometer. The implementation of this interferometer is discussed, and results of trials with different point diffractors are presented in this paper. The performance of the interferometer under various flow conditions was investigated. Results are presented which show the effects of the interferometer parameters such as pinhole size and pinhole-plate optical density on the performance of the system.

Brock, N. J.↗

In vitro flow measurements in ion sputtered hydrocephalus shunts

This paper describes an experimental procedure for accurate measurements of the pressure-drop/flow rate relationship in hydrocephalus shunts. Using a fish-hook arrangement, small flow rates in a perforated ion-sputtered Teflon microtubule were measured in vitro in a pressured system and were correlated with pressure in the system. Results indicate that appropriate drainage rates could be obtained in the physiological range for hydrocephalus shunts.

Cho, Y. I.↗

Mean and fluctuating flow measurements of a fully-developed, non-adiabatic, hypersonic boundary layer

Extensive boundary-layer measurements have been made on a cone-ogive-cylinder model at a free-stream Mach number of 7.0 and momentum-thickness Reynolds number of 8500. Mean flow transformations and calculated turbulence correlations are presented which are in good agreement with previous incompressible results. New quantitative turbulence measurements including measurements of the first higher moment and probability density of fluctuations in mass flow and total temperature in hypersonic flow are also presented. The higher moment and probability density data show that the characters of the fluctuation modes of the mass flow and total temperature are significantly different in the wall region and in the outer part of the boundary layer. These differences together with data on the turbulence scale and lifetime obtained from autocorrelation and space-time correlation measurements are discussed.

Owen, F. K.↗

Three dimensional LDV flow measurements and theoretical investigation in a radial inflow turbine scroll

A two-color LDV system was used in the measurement of three orthogonal velocity components at 758 points located throughout the scroll and the unvaned portion of the nozzle of a radial inflow turbine scroll. The cold flow experimental results are presented for the velocity field at the scroll tongue. In addition, a total pressure loss of 3.5 percent for the scroll is revealed from the velocity measurements combined with the static pressure readings. Moreover, the measurement of the three normal stresses of the turbulence has showed that the flow is anisotropic. Furthermore, the mean velocity components are compared with a numerical solution of the potential flow field using the finite element technique. The theoretical prediction of the exit flow angle variation agrees well with the experimental results. This variation leads to a higher scroll pattern factor which can be avoided by controlling the scroll cross sectional area distribution.

Malak, Malak Fouad↗

Commercial-Off-The-Shelf Microelectromechanical Systems (MEMS) Flow-Measurement Probes Fabricated And Assembled

As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.

Redding, Chip↗

Advances in microsensor development for gas and flow measurement in space power and propulsion systems

Emerging microelectromechanical sculpturing technology is presently extended, in conjunction with the use of deep semiconductor impurities having extreme flow sensitivities, small masses for shortest time response, and unconventional electrode schemes for elevated-temperature operation, for rocket-engine fuel flow sensing tasks. The radiation component of heat transfer is negligible, so that the device operates on the basis of conduction and convection loss.

Henderson, H. T.↗

Scaling of airfoil self-noise using measured flow parameters

Data from an airfoil broadband self-noise study are reported. Attention here is restricted to two-dimensional models at zero angle of attack to the flow. The models include seven NACA 0012 airfoil sections and five flat plate sections with chordlengths ranging from 2.54 to 60.96 cm. Testing parameters include flow velocity to 71.3 m/s and boundary-layer turbulence through natural transition and by tripping. Detailed aerodynamic measurements are conducted in the near-wake of the sharp trailing edges. The noise spectra of the self-noise sources are determined by the use of a cross-spectral technique. The acoustic data are normalized using the measured aerodynamic parameters in order to evaluate a commonly used scaling law. An examination of the Reynolds number dependence of the normalized overall levels has revealed a useful scaling result. This result appears to quantify the transition between turbulent boundary-layer trailing-edge noise and laminar boundary-layer vortex shedding noise.

Brooks, T. F.↗

Hybrid pulse-burst / cross-correlation DGV for high-speed flow measurements at 100 kHz

Hybrid pulse-burst Doppler global velocimetry (PB-DGV)/pulse-burst, cross-correlation DGV (PB-CC-DGV) was demonstrated for the first time in the NASA Langley 4-foot Supersonic Unitary Plan Wind Tunnel, allowing simultaneous acquisition of mean and instantaneous high-repetition-rate velocity fields. The technique was used to make planar velocity measurements across an oblique shockwave generated by a large splitter plate set at a -2° angle of attack in a Mach 2.4 flow. Sequences of more than 100 consecutive instantaneous velocity images were obtained at a rate of 100 kHz. Velocity fields from both aspects of the hybrid measurement indicated errors less than 1-percent of anticipated velocities. Likewise, all assessments of measurement precision were approximately 1.6-percent of the local velocities. Additional demonstrations in different flowfields including a subsonic axi-symmetric jet and a supersonic Mars reentry vehicle model further illustrate the utility of the new hybrid method.

laser↗

Temperature and Flow Measurements in Incompressible Heated Jets

An experimental study is conducted to perform time-resolved temperature and velocity measurements on a Mach 0.08 jet at total temperatures of 295 K and 353 K. Mean and rms temperature data acquired using two fine wire sensors with diameters 1.3 and 3.8 μm are compared. In order to extend the limited frequency response of the wires, the temperature data are post-processed using a frequency compensation technique available in the literature. Corresponding velocity measurements are performed at cold and heated conditions using single and parallel wire probes. Simultaneously measured temperature and velocity data obtained using the parallel wire probe are used to calculate correlations pertinent to axial turbulent heat flux. In addition to shedding some light on the aerothermal properties of heated turbulent jets, vis-`a-vis their cold counterparts, this study also provides a database for numerical prediction of these flows.

Temperature measurement, turbulence, Jets, Turbule↗

Flow Measurements and Multiple Pure Tone Noise From a Forward Swept Fan

A forward-swept fan, designated the Quiet High Speed Fan (QHSF), was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel to investigate its noise reduction relative to a baseline fan of the same aerodynamic performance. The objective of the Quiet High Speed Fan was a 6-dB reduction in the Effective Perceived Noise Level relative to the baseline fan at the takeoff condition. The intent of the Quiet High Speed Fan design was to provide both a multiple pure tone noise reduction from the forward sweep of the fan rotor and a rotor-stator interaction blade passing tone noise reduction from a leaned stator. The tunnel noise data indicted that the Quiet High Speed Fan was quieter than the baseline fan for a significant portion of the operating line and was 6 dB quieter near the takeoff condition. Although reductions in the multiple pure tones were observed, the vast majority of the EPNdB reduction was a result of the reduction in the blade passing tone and its harmonics. Laser Doppler Velocimetry (LDV) and shroud unsteady pressure measurement data were obtained upstream of the QHSF and baseline rotors to improve the understanding of the shocks which propagate upstream of the two fans when they are operated at high speeds. The flow phenomena that produce multiple pure tone noise is discussed and compared to measurements of the fan acoustic inlet modes and the far field noise signature of the fan.

Weir, Donald S.↗

A new approach to high-speed flow measurements using constant voltage anemometry

The paper addresses the basic features of conventional instrumentation, such as the constant temperature (CTA) and the constant current (CCA) anemometers, their limitations, and describes a totally new approach to high-speed dynamic measurements using a constant voltage anemometer (CVA). The paper describes the design features of a newly developed CVA and compares preliminary results obtained with CVA and conventional anemometry in low- and high-speed flows.

Mangalam, S. M.↗