Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An embedded 3D fracture modeling approach for simulating fracture-dominated fluid flow and heat transfer in geothermal reservoirs

In this paper, we describe an efficient modeling approach, named embedded discrete fracture method (EDFM), for incorporating arbitrary 3D, discrete fractures, such as hydraulic fractures or faults, into modeling fracture-dominated fluid flow and heat transfer in fractured geothermal reservoirs. This technique allows 3D discrete fractures to be discretized independently from surrounding rock volume and inserted explicitly into a primary fracture/matrix grid, generated without including 3D discrete fractures in prior. An effective computational algorithm is developed to discretize these 3D discrete fractures and construct local connections between 3D fractures and fracture/matrix grid blocks representing the surrounding rock volume. The constructed gridding information on 3D fractures is then added to the primary grid. This embedded fracture modeling approach can be directly implemented into a developed geothermal reservoir simulator via the integral finite difference (IFD) method or with TOUGH2 technology. This embedded fracture modeling approach is very promising and computationally efficient to handle realistic 3D discrete fractures with complicated geometries, connections, and spatial distributions. Compared with other fracture modeling approaches, it avoids cumbersome 3D unstructured, local refining procedures, and increases computational efficiency by simplifying Jacobian matrix size and sparsity, while maintaining enough accuracy. Several numeral simulations are presented to demonstrate the utility and robustness of the proposed technique. Our numerical experiments show that this approach captures all the key patterns about fluid flow and heat transfer dominated by fractures in these cases. Thus, this approach is readily available to the simulation of fractured geothermal reservoirs with both artificial and natural fractures.

15 GEOTHERMAL ENERGY↗

Evaluation of RANS vs. LES simulation of fluid flow through 3 × 3 rod bundle with a simple spacer grid as a precursor to coupled fluid–structure interaction simulations

The research literature on Computational Fluid Dynamics (CFD) of coolant flow through rod bundles with spacer-grids and mixing vanes is replete, ranging from high fidelity Large Eddy Simulation (LES)/Direct Numerical Simulation (DNS) simulations to Reynolds-Averaged Navier–Stokes (RANS) modeled studies. The mixing of flow between subchannels and the pressure drop through the bundle are fundamental quantities useful for comparing and evaluating CFD methods. Less commonly observed and compared are the forces exerted onto the structure by the fluid. The present study seeks to evaluate the use of RANS simulations for predicting the structural response to fluid flow. Wall resolved RANS simulations are benchmarked against LES simulations of fluid flow at a Reynolds number of 15,000 through a 3 × 3 fuel rod bundle with a simple spacer grid. Velocity line-plots are compared showing good agreement between RANS and LES results, ascertaining that the former is capable of capturing the essential time-averaged velocity profile. Additionally, the distribution of forces on the spacer grid and fuel rods are collected as a function of time and space. The RANS methods are evaluated using the frequency and magnitude of the fluctuating forces on various portions of the structure as compared to LES. In conclusion, the power spectral density evaluation of the models reveal underprediction of force amplitude on the rod walls by RANS and also discrepancy in the prediction of high frequency spectra, especially in the immediate vicinity of spacer-grid structure, which may be attributed to the lack of random turbulence fluctuation or insufficient modeling of small-scale eddies in RANS simulation.

FIV↗

Results of the Workshop on Two-Phase Flow, Fluid Stability and Dynamics: Issues in Power, Propulsion, and Advanced Life Support Systems

The Two-phase Flow, Fluid Stability and Dynamics Workshop was held on May 15, 2003 in Cleveland, Ohio to define a coherent scientific research plan and roadmap that addresses the multiphase fluid problems associated with NASA s technology development program. The workshop participants, from academia, industry and government, prioritized various multiphase issues and generated a research plan and roadmap to resolve them. This report presents a prioritization of the various multiphase flow and fluid stability phenomena related primarily to power, propulsion, fluid and thermal management and advanced life support; and a plan to address these issues in a logical and timely fashion using analysis, ground-based and space-flight experiments.

McQuillen, John↗

Performance of WPA Conductivity Sensor during Two-Phase Fluid Flow in Microgravity

The Conductivity Sensor designed for use in the Node 3 Water Processor Assembly (WPA) was based on the existing Space Shuttle application for the fuel cell water system. However, engineering analysis has determined that this sensor design is potentially sensitive to two-phase fluid flow (gadliquid) in microgravity. The source for this sensitivity is the fact that gas bubbles will become lodged between the sensor probe and the wall of the housing without the aid of buoyancy in l-g. Once gas becomes lodged in the housing, the measured conductivity will be offset based on the volume of occluded gas. A development conductivity sensor was flown on the NASA Microgravity Plan to measure the offset, which was determined to range between 0 and 50%. Based on these findings, a development program was initiated at the sensor s manufacturer to develop a sensor design fully compatible with two-phase fluid flow in microgravity.

Carter, Layne↗

System proportions fluid-flow in response to demand signals

Control system provides proportioned fluid flow rates in response to demand signals. It compares a digital signal, representing a flow demand, with a reference signal to yield a control voltage to one or more solenoid valves connected to orifices of a predetermined size.

Source record↗

System for measuring Reynolds in a turbulently flowing fluid

A system for measuring momentum flux in a turbulently flowing fluid includes: a sensing apparatus for dynamically sensing the mainstream and the cross velocity components of the fluid, a transducer operative to provide two electrical output signals representative of the velocity components in the mainstream and in the cross direction, and signal processors to derive the Reynolds stress wave and the Reynolds stress.

Cheng, D. Y.↗

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey↗

Eocene-Oligocene Metamorphism, Fluid Flow and Deformation in the Ruby Mountains-East Humboldt Range Metamorphic Core Complex

Metamorphic core complexes are ubiquitous in collapsed orogens globally and play a primary role in crustal exhumation. Here, we investigate the metamorphic history of the Ruby Mountains-East Humboldt Range metamorphic core complex, Nevada, using petrochronology to understand how magmatism, metamorphism and deformation interact to modulate crustal rheology, and the timing of exhumation within the Sevier orogenic belt. Field study, microstructural analysis, thermobarometry and laser ablation split-stream monazite, titanite and allanite petrochronology of the mylonitic footwall were integrated to elucidate the pressure-temperature-time (P-T-t) evolution. Major-, trace-element and quartz-in-garnet thermobarometry show peak metamorphism occurred at 5.5–6 kbar and 600–650°C across the study area. Monazite and titanite U-(Th)-Pb petrochronology constrain this episode of metamorphism to 88–81 Ma with the structurally deepest samples yielding dates down to ca. 71 Ma. The preservation of peak metamorphic mineral assemblages indicates these rocks remained at near-peak temperature conditions into the Cenozoic. Cenozoic metamorphism occurred during a punctuated episode contemporaneous with the Great Basin ignimbrite flare up. All samples show a distinct 39–37 Ma population of monazite, titanite and allanite dates that correlate with the emplacement of quartz diorite and gabbro intrusions throughout the footwall. Accessory phases contain zoning textures in backscattered electron images that are consistent with fluid-mediated dissolution-reprecipitation reactions. The U-(Th)-Pb analyses from these zones yield 39–27 Ma dates interpreted as the timing of fluid flow. The results of this study elucidate the integrated importance of magmatism, melting and fluid flow in driving the coupled evolution of Late Cretaceous metamorphism within the Sevier hinterland and the subsequent Cenozoic metamorphic core complex development that exhumed the middle crust.

58 GEOSCIENCES↗

Simple models of fluid flow at the core surface derived from geomagnetic field models

The fluid flow at the core surface is determined for a given model of temporal magnetic field variation, assuming steady flow and adopting the frozen-flux approximation. Evidence is presented for ageostrophic flow in the form of flow across the geographical equator. A simple pattern of the large-scale toroidal part of the flow is found. The pattern is nearly symmetric about the equator. Changes in the flow pattern are obtained from flow maps covering 5-year intervals beginning in 1915.

Bloxham, Jeremy↗

Simulation of Fluid Flow and Collection Efficiency at Low Stokes Number

Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) Robust probe are presented. The cases cover a range of freestream velocity from 10-135 m/s, and particle sizes from 1-200 µm. This combination produces results for Stokes numbers in the range of 0.07-1092. A blended modified Stokes (defined in the paper) is introduced which covers a range of 0.07-146. Of particular interest is the collection efficiency of the sensing element (a forward-facing half-pipe), Etot, in the low Stokes number regime. It was observed that the collection efficiency of the sensing area approached one for large Stokes numbers (>100) as expected. As blended modified Stokes number approached one, the Etot dropped to approximately 0.5. By blended modified Stokes numbers of 0.3, the Etot has dropped to essentially zero. Plotting collection versus blended modified Stokes number, the different freestream velocities collapsed quite well on to a single curve. The paper presents a discussion on the flowfield and local collection efficiency, beta, in an effort to explain the predictions. Of particular interest is what is essentially a shadow zone in plain sight. As the Stokes number is reduced, the local beta along the centerline of the half-pipe goes to zero. This occurs at Stokes numbers where the overall collection, Etot, is still appreciable. An empirical relation was developed to allow for corrected collection values at low Stokes numbers. The correlation remains within 2% for blended modified Stokes numbers above 1, and within 6% for all cases.

Instrumentation↗

Simulation of Fluid Flow and Collection Efficiency at Low Stokes Number

Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) Robust probe are presented. The cases cover a range of freestream velocity from 10-135 m/s, and particle sizes from 1-200 µm. This combination produces results for Stokes numbers in the range of 0.07-1092. A blended modified Stokes (defined in the paper) is introduced which covers a range of 0.07-146. Of particular interest is the collection efficiency of the sensing element (a forward-facing half-pipe), Etot, in the low Stokes number regime. It was observed that the collection efficiency of the sensing area approached one for large Stokes numbers (>100) as expected. As blended modified Stokes number approached one, the Etot dropped to approximately 0.5. By blended modified Stokes numbers of 0.3, the Etot has dropped to essentially zero. Plotting collection versus blended modified Stokes number, the different freestream velocities collapsed quite well on to a single curve. The paper presents a discussion on the flowfield and local collection efficiency, beta, in an effort to explain the predictions. Of particular interest is what is essentially a shadow zone in plain sight. As the Stokes number is reduced, the local beta along the centerline of the half-pipe goes to zero. This occurs at Stokes numbers where the overall collection, Etot, is still appreciable. An empirical relation was developed to allow for corrected collection values at low Stokes numbers. The correlation remains within 2% for blended modified Stokes numbers above 1, and within 6% for all cases.

Instrumentation↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady geothermal field, Nevada, USA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a throughgoing network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density.

58 GEOSCIENCES↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady Geothermal Field, Nevada using PCA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a through going network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density. This submission includes the published journal article detailing this work, the published 3-D geologic map of the Brady Geothermal Area used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity, 3-D well data, along which geologic data were sampled for PCA analyses, and associated metadata file. This work was done using existing R programs.

15 GEOTHERMAL ENERGY↗