Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison of Artificial Compressibility Methods for Coupled Laminar Fluid Flow and Heat Transfer

Artificial compressibility (AC) methods for incompressible flows perturb the mass continuity equation by the time derivative of the pressure field to achieve direct coupling between pressure and velocity without the need for a projection method. Several variations of the original AC method have been proposed (e.g., the entropically damped artificial compressibility [EDAC] method) that can, in some scenarios, improve on the original model. In this paper, we methodically compare the results of the original AC model and the EDAC model for both steady-state and transient problems with coupling between the momentum and energy equations. We demonstrate that the EDAC model and the AC model yield similar numerical results, and the EDAC model is 10%-20% faster than the AC model for a given problem.

Oz, Furkan [ORNL] (ORCID:0000000265831724)↗

Influence of dissolved salts and impurities on seawater on heat transfer and fluid flow through fuel channels and debris bed

This project aims to better understand this mechanism and its effect on heat transfer. Specifically, experimental research was conducted to investigate the long term coolability issues in scaled test setups. Advanced diagnostic and measurement techniques were investigated and incorporated into an annular test facility and a debris bed test facility. The diagnostic techniques investigated included: radioactively tagged salt solution, Frisch collar radiation detector array, neutron and x-ray imaging systems, and a Rayleigh backscatter-based fiber-optic temperature system. Models were checked against the in-situ experimental data and recommendations were made for modeling purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing Fluid Flow Pressure and Saturation Prediction Accuracy and Reducing Uncertainty with Committee Machine – Illinois Basin Decatur Project (IBDP) as a Case Study

This is the conference paper accompanying an oral presentation at the 17th International Conference on Greenhouse Gas Control Technologies GHGT-17 held in Calgary, Canada, October 20-24, 2024. Carbon capture and storage (CCS) is a way to play a critical role in the global transition to a low-emission economy. Current progress is hampered by a number of factors, among which the lack of risk-informed design tools and decision support frameworks is seen as a major roadblock. Significant interest exists in using artificial intelligence to accelerate CCS site feasibility studies, as well as to facilitate the permit application process. Existing works commonly train a single deep learning model. This work investigates the feasibility of using a conventional ensemble learning (committee machine) technique to further improve prediction accuracy. Ensemble-based algorithms generally improve over individual base learners in terms of robustness and accuracy. Deep ensembles, however, are time-consuming to create and train. A pragmatic question is whether small-sized ensembles may lead to prediction improvement. Here we evaluated the efficacy of an ensemble learning technique using the latent spectral model (LSM), an efficient deep neural operator algorithm, as base learners. Preliminary results, obtained using the Illinois Basin-Decatur Project (IBDP) carbon sequestration data/model, show that small-sized ensembles can improve prediction over the base learners, achieving prediction accuracy of ~1.6 psi root mean square error (RMSE) on pressure (relative the average reservoir pressure of 3150 psi), and less than 1.3% for saturation.

Sun, Alexander↗

Effect of Shear Displacement and Stress Changes on Fracture Hydraulic Aperture and Flow Anisotropy

Fluid flow in fractures has the potential to drastically change the economic, environmental, and safety risks associated with a subsurface operation. This work focuses on the analysis of experimental shear fracturing and subsequent shear displacement of a shale specimen that contains multiple pre-existing natural fractures. A triaxial direct shear apparatus with concurrent µCT imaging allowed continuous monitoring of sample permeability and changes in fracture geometry during fracture creation, displacement, and changes in stress. Steady-state, low Reynolds number fluid flow simulations were used to determine the changes of each individual fracture’s hydraulic aperture due to displacement and effective stress. The development of anisotropy in the hydraulic aperture of a generated shear fracture was determined for shear displacements of 0.38, 0.74, and 2.04 mm. At high confining stress (30 MPa), shear displacement significantly reduced the hydraulic aperture of the shear fracture to below flow detectable limits and X-ray imaging resolution (23 × 23 × 23 µm 3 ). The shear generated fracture was found to be more sensitive to changes in effective stress compared to the pre-existing natural fractures. Existing models derived from fluid flow equations accounting for stochastic fracture roughness were able to partially fit the simulated flow properties of the pre-existing fractures, but no model was found to fit the flow properties of the newly formed shear fracture. These results are the first report of simultaneous changes in the geometry and flow properties of surrounding, parallel natural fractures as a shear fracture is generated with varying stress and shear displacement conditions.

58 GEOSCIENCES↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heating, ventilation, air conditioning and refrigeration system

A heating, ventilation, air conditioning and refrigeration (HVAC/R) system includes a sorption circuit including a heat absorption heat exchanger in fluid communication with a primary fluid flow source such that a primary fluid flow from is directed therethrough. The heat absorption heat exchanger is configured to exchange thermal energy between the primary fluid flow and a secondary fluid flow. A sorption heat exchanger includes a sorbent material to adsorb or absorb the primary fluid flow, generating thermal energy. The sorption heat exchanger is configured to transfer the generated thermal energy to a tertiary fluid flow. A heat exchange circuit is in fluid communication with the sorption circuit and includes a control valves connected to both the secondary fluid flow and the tertiary fluid flow configured to selectably direct the secondary fluid flow and/or the tertiary fluid flow to a conditioning heat exchanger or an ambient heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-physics modeling of injected nanoparticles effect on remediation of CO 2 leakage through cracks

One potential risk in CO 2 sequestration is the leakage of carbon dioxide, which can result in contamination of underground water, creating potential threats to existing ecosystems. The common leakage pathway is through the pre-existing fractures or discontinuities within cement in the wellbore, incurred by the environmental conditions imposed on the cement. Injecting nanoparticles into pre-existing cracks is one of the most recently proposed ideas for mitigating fracture propagation in cement CO 2 sequestration. To demonstrate the feasibility of this new technology, a numerical approach was taken in this work, as it is challenging to investigate it in a laboratory setting. We proposed a coupled ALE (Arbitrary Lagrangian–Eulerian)–DEM (Discrete Element Method)–peridynamic modeling strategy within the LS-Dyna package to investigate the intertwined interaction among the CO 2 fluid flow, native fluid (e.g., brine), particle clusters, and cracks within the cement. The numerical results demonstrate that injected nanoparticles can effectively reduce the pressure exerted on the crack surface. Accordingly, the potential fracture propagation at the crack tip would be reduced compared to corresponding cases without nanoparticels as pressurized by fluid flow. This result verifies the effectiveness of proposed nanoparticle injection technology. Finally, using this established modeling strategy, the effect of filling particles on the fracture mitigation for different crack geometries (e.g. particle cluster patterns, aspect ratio of crack aperture and length) and CO 2 reservoir pressure are examined. The result shows that injected particles successfully reduce the fracture propagation in these scenarios.

42 ENGINEERING↗

Internally-cooled compressor diaphragm

An internally-cooled diaphragm for an internally-cooled compressor is provided. The internally-cooled diaphragm may include an annular body configured to cool a process fluid flowing through a fluid pathway of the internally-cooled compressor. The annular body may define a return channel of the fluid pathway, and a cooling pathway in thermal communication with the fluid pathway. The return channel may be configured to at least partially diffuse and de-swirl the process fluid flowing therethrough, and the cooling pathway may be configured to receive a coolant to absorb heat from the process fluid flowing through the return channel.

42 ENGINEERING↗