Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID FLOW PATTERNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Experiment and model for a Stokes layer in a strongly coupled dusty plasma

A Stokes layer, which is a flow pattern that arises in a viscous fluid adjacent to an oscillatory boundary, was observed in an experiment using a two-dimensional strongly coupled dusty plasma. Liquid conditions were maintained using laser heating, while a separate laser manipulation applied an oscillatory shear that was localized and sinusoidal. The evolution of the resulting flow was analyzed using space-time diagrams. These figures provide an intuitive visualization of a Stokes layer, including features such as the depth of penetration and wavelength. Another feature, the characteristic speed for the penetration of the oscillatory flow, also appears prominently in space-time diagrams. To model the experiment, the Maxwell-fluid model of a Stokes layer was generalized to describe a two-phase liquid. In our experiment, the phases were gas and dust, where the dust cloud was viscoelastic due to strong Coulomb coupling. Furthermore, the model is found to agree with the experiment, in the appearance of the space-time diagrams, and in the values of the characteristic speed, depth of penetration, and wavelength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, is a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Saltstone SDU6 Modeling Study

A new disposal unit, designated as Saltstone Disposal Unit 6 (SDU6), is being designed for support of site accelerated closure goals and salt waste projections identified in the new Liquid Waste System Plan. The unit is a cylindrical disposal cell of 375 ft in diameter and 43 ft in height, and it has a minimum 30 million gallons of capacity. SRNL was requested to evaluate the impact of an increased grout placement height on the flow patterns radially spread on the floor and to determine whether grout quality is impacted by the height. The primary goals of the work are to develop the baseline Computational Fluid Dynamics (CFD) model and to perform the evaluations for the flow patterns of grout material in SDU6 as a function of elevation of grout discharge port and grout rheology. Two transient grout models have been developed by taking a three-dimensional multiphase CFD approach to estimate the domain size of the grout materials radially spread on the facility floor and to perform the sensitivity analysis with respect to the baseline design and operating conditions such as elevation height of the discharge port and fresh grout properties. For the CFD modeling calculations, air-grout Volume of Fluid (VOF) method combined with Bingham plastic and time-dependent grout models were used for examining the impact of fluid spread performance for the initial baseline configurations and to evaluate the impact of grout pouring height on grout quality. The grout quality was estimated in terms of the air volume fraction for the grout layer formed on the SDU6 floor, resulting in the change of grout density. The study results should be considered as preliminary scoping analyses since benchmarking analysis is not included in this task scope. Transient analyses with the Bingham plastic model were performed with the FLUENT TM code on the high performance parallel computing platform in SRNL. The analysis coupled with a transient grout aging model was performed by using ANSYS-CFX code in the parallel computing platform in Mercer University. Recommended operational guidance was developed assuming that local shear rates and flow patterns related to radial spread along the SDU floor can be used as a measure of grout performance and spatial dispersion affected by the grout height and viscosity. The main conclusions drawn from the grout modeling and calculations are as follows: • The 5 ft height baseline results show that when the 150 gpm grout flow with a 5 Pa yield stress and a 60 cp viscosity is poured down through a 3 inch discharge port, the grout is spread radially up to about 64 ft distance from the pouring center after 2 hours’ pouring time. The air volume fraction of the grout layer is about 29% at 5 minutes’ transient time, and it is reduced by about 9% in 2 hours’ pouring time, resulting in the grout density consisting of about 80% grout and 20% air volume fractions. • The sensitivity results show that when the discharge port is located at a higher position, a larger amount of air is trapped inside the layer formed below the discharge port at the early transient time of less than 30 minutes because of the higher impinging momentum of the grout flow on the floor, resulting in the formation of less smooth layer. • The results clearly indicate that the radial spread for the 43 ft discharge port is about 10% faster than that of the 5 ft discharge port for the early transient period of 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the radial distance spread on the disposal floor. • When grout quality is related to grout volume fraction, the grout volume fraction for the 43 ft discharge port has lower volume fraction than the 5 ft discharge port for the transient period of the first 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the grout volume fraction for the layer accumulated on the disposal floor. • A modified Bingham plastic model coupled with time-dependent viscosity behavior was developed for conducting the initial scoping calculations to assess the impact of fluid residence time on radial spreading and basic flow patterns. • The results for the transient viscosity model show that when grout material becomes more viscous, the thickness of the grout layer accumulated on the floor becomes higher, but the radial distance spread on the horizontal floor becomes smaller. The early transient results for the grout density with about 32% air volume fractions are in reasonable agreement with those of the idealized Bingham plastic model. • It is recommended that the current models developed here be benchmarked against the experimental results for critical applications of the modeling results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hidden fluid mechanics: Learning velocity and pressure fields from flow visualizations

For centuries, flow visualization has been the art of making fluid motion visible in physical and biological systems. Although such flow patterns can be, in principle, described by the Navier-Stokes equations, extracting the velocity and pressure fields directly from the images is challenging. We addressed this problem by developing hidden fluid mechanics (HFM), a physics-informed deep-learning framework capable of encoding the Navier-Stokes equations into the neural networks while being agnostic to the geometry or the initial and boundary conditions. We demonstrate HFM for several physical and biomedical problems by extracting quantitative information for which direct measurements may not be possible.

Raissi, Maziar↗

Flow Partitioning in Fully Saturated Soil Aggregates

Microbes play an important role in facilitating organic matter decomposition in soils, which is a major component of the global carbon cycle. Microbial dynamics are intimately coupled to environmental transport processes, which control access to labile organic matter and other nutrients that are needed for the growth and maintenance of microorganisms. Transport of soluble nutrients in the soil system is arguably most strongly impacted by preferential flow pathways in the soil. Since the physical structure of soils can be characterized as being formed from constituent micro aggregates which contain internal porosity, one pressing question is the partitioning of the flow among the “inter-aggregate” and “intra-aggregate” pores and how this may impact overall solute transport within heterogeneous soil structures. The answer to this question is particularly important in evaluating assumptions to be used in developing upscaled simulations based on highly-resolved mechanistic models. We constructed a number of diverse multi-aggregate structures with different packing ratios by stacking micro-aggregates containing internal pores and varying the size and shape of inter-aggregate pore spacing between them. We then performed pore-scale flow simulations using computational fluid dynamics methods to determine the flow patterns in these aggregate-of-aggregates structures and computed the partitioning of the flow through intra- and inter-aggregate pores as a function of the spacing between the aggregates. The results of these numerical experiments demonstrate that soluble nutrients are largely transported via flows through inter-aggregate pores. Although this result is consistent with intuition, we have also been able to quantify the relative flow capacity of the two domains under various conditions. For example, in our simulations, the flow capacity through the aggregates (intra-aggregate flow) was less than 2% of the total flow when the spacing between the aggregates was larger than 18 micron. Inter-aggregate pores continued to be the dominant flow pathways even at much smaller spacing; intra-aggregate flow was less than 10% of the total flow when the inter- and intra-aggregate pore sizes were comparable. Such studies are making it possible to identify which model upscaling assumptions are realistic and what computational methods are required for detailed numerical investigation of microbial carbon cycling dynamics in soil systems.

computational fluid dynamics↗

Mixed-flow design for microfluidic printing of two-component polymer semiconductor systems

The rational creation of two-component conjugated polymer systems with high levels of phase purity in each component is challenging but crucial for realizing printed soft-matter electronics. Here, we report a mixed-flow microfluidic printing (MFMP) approach for two-component π -polymer systems that significantly elevates phase purity in bulk-heterojunction solar cells and thin-film transistors. MFMP integrates laminar and extensional flows using a specially microstructured shear blade, designed with fluid flow simulation tools to tune the flow patterns and induce shear, stretch, and pushout effects. This optimizes polymer conformation and semiconducting blend order as assessed by atomic force microscopy (AFM), transmission electron microscopy (TEM), grazing incidence wide-angle X-ray scattering (GIWAXS), resonant soft X-ray scattering (R-SoXS), photovoltaic response, and field effect mobility. For printed all-polymer (poly[(5,6-difluoro-2-octyl-2H-benzotriazole-4,7-diyl)-2,5-thiophenediyl[4,8-bis[5-(2-hexyldecyl)-2-thienyl]benzo[1,2-b:4,5-b′]dithiophene-2,6-diyl]-2,5-thiophenediyl]) [J51]:(poly{[N,N′-bis(2-octyldodecyl)naphthalene-1,4,5,8-bis(dicarboximide)-2,6-diyl]-alt-5,5′-(2,2′-bithiophene)}) [N2200]) solar cells, this approach enhances short-circuit currents and fill factors, with power conversion efficiency increasing from 5.20% for conventional blade coating to 7.80% for MFMP. Moreover, the performance of mixed polymer ambipolar [poly(3-hexylthiophene-2,5-diyl) (P3HT):N2200] and semiconducting:insulating polymer unipolar (N2200:polystyrene) transistors is similarly enhanced, underscoring versatility for two-component π -polymer systems. Mixed-flow designs offer modalities for achieving high-performance organic optoelectronics via innovative printing methodologies.

42 ENGINEERING↗

Preliminary results from the Viking orbiter imaging experiment

During its first 30 orbits around Mars, the Viking orbiter took approximately 1000 photographic frames of the surface of Mars with resolutions that ranged from 100 meters to a little more than 1 kilometer. Most were of potential landing sites in Chryse Planitia and Cydonia and near Capri Chasma. Contiguous high-resolution coverage in these areas has led to an increased understanding of surface processes, particularly cratering, fluvial, and mass-wasting phenomena. Most of the surfaces examined appear relatively old, channel features abound, and a variety of features suggestive of permafrost have been identified. The ejecta patterns around large craters imply that fluid flow of ejecta occurred after ballistic deposition. Variable features in the photographed area appear to have changed little since observed 5 years ago from Mariner 9. A variety of atmospheric phenomena were observed, including diffuse morning hazes, both stationary and moving discrete white clouds, and wave clouds covering extensive areas.

Carr, M. H.↗

Rotor Re-Design for the SSME Fuel Flowmeter

The present report describes the process of redesigning a new rotor for the SSME Fuel Flowmeter. The new design addresses the specific requirement of a lower rotor speed which would allow the SSME operation at 1 15% rated power level without reaching a blade excitation by the wakes behind the hexagonal flow straightener upstream at frequencies close to the blade natural frequency. A series of calculations combining fleet flowmeters test data, airfoil fluid dynamics and CFD simulations of flow patterns behind the flowmeter's hexagonal straightener has led to a blade twist design alpha = alpha (radius) targeting a kf constant of 0.8256. The kf constant relates the fuel volume flow to the flowmeter rotor speed, for this particular value 17685 GPM at 3650 RPM. Based on this angle distribution, two actual blade designs were developed. A first design using the same blade airfoil as the original design targeted the new kf value only. A second design using a variable blade chord length and airfoil relative thickness targeted simultaneously the new kf value and an optimum blade design destined to provide smooth and stable operation and a significant increase in the blade natural frequency associated with the first bending mode, such that a comfortable margin could be obtained at 115% RPL. The second design is a result of a concurrent engineering process, during which several iterations were made in order to achieve a targeted blade natural frequency associated with the first bending mode of 1300 Hz. Water flow tests preliminary results indicate a kf value of 0.8179 for the f-irst design, which is within 1% of the target value. The second design rotor shows a natural frequency associated with the first bending mode of 1308 Hz, and a water-flow calibration constant of kf 0.8169.

Marcu, Bogdan↗

Preplanning for D and D: Monitoring the Vadose Zone at Radioactive Waste Trenches

Planning for ultimate Decontamination and Decommissioning (D and D) of a nuclear facility is as much a part of a successful nuclear strategy as is the ultimate disposal of radioactive waste. As facilities, in this case radioactive waste disposal trenches, are closed and abandoned leading to ultimate decommissioning, long term monitoring may be required. However, preplanning by characterizing, modeling, and monitoring the environment around the facility prior to and during operations will allow a performance assessment to be made and future behavior predicted. In the radioactive waste burial grounds of the Savannah River Site new slit trenches were constructed to receive demolition debris associated with site foot print reduction. Some of the construction debris and associated process waste contained small amounts of tritium. Since the trenches were constructed over an existing tritium groundwater plume the monitoring and performance assessment of the trench, particularly with respect to tritium contributions to the vadose zone and groundwater, were important. These disposal trenches vary in length and width but are typically constructed within the upper 7 to 8 meters (21 to 24 feet) of the local sediments. The unconfined aquifer (water table) typically underlies the area at depths varying from 20 to 24 meters (60 to 72 feet), depending on elevation. Therefore, with downward flow and 13 to 16 meters (40 to 48 feet) of unsaturated sediments separating the base of the waste trenches from the unconfined aquifer, there was potential for an environmental impact to the sediments within the vadose zone and to the underlying groundwater. Monitoring and predicting this impact can support ultimate D and D activities and future performance assessment evaluation. From this work several key observations were made that will support long term monitoring and subsequent D and D: - The observed lateral variation of thinly bedded sands and clays may be less than 20 meters particularly if lenticular sands are present. Ultimate D and D should consider monitoring and remedial activities that consider sampling on scales to address this issue. - The detailed modeling, when compared with the modeled depositional patterns, indicates flow paths for vadose zone fluids, therefore a plan should allow for these flow paths. - Detailed lithostratigraphic modeling, when based on correlations between soil properties, CPT soundings and borehole geophysical logs, can aid in precision placement of subsurface sensors and sample points for performance monitoring and D and D assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Internal flow patterns on heat transfer characteristics of a closed-loop oscillating heat-pipe with check valves using ethanol and a silver nano-ethanol mixture

The aim of this research was to investigate the internal flow patterns and heat transfer characteristics of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV). The ratio of number of check valves to meandering turns was 0.2. Ethanol and a silver nano-ethanol mixture were used as working fluids with a filling ratio of 50% by total volume of tube. The CLOHP/CV was made of a glass tube with an inside diameter of 2.4 mm. The evaporator section was 50 mm and 100 mm in length and there were 10 meandering turns. An inclination angle of 90 from horizontal axis was established. The evaporator section was heated by an electric heater and the condenser section was cooled by distilled water. Temperature at the evaporator section was controlled at 85 C, 105 C and 125 C. The inlet and outlet temperatures were measured. A digital camera and video camera were used to observe the flow patterns at the evaporator. The silver nano-ethanol mixture gave higher heat flux than ethanol. When the temperature at the evaporator section was increased from 85 C to 105 C and 125 C. It was found that, the flow patterns occurred as annular flow + slug flow, slug flow + bubble flow and dispersed bubble flow + bubble flow respectively. The main regime of each flow pattern can be determined from the flow pattern map ethanol and a silver nano-ethanol mixture. Each of the two working fluids gave corresponding flow patterns. (author)

42 ENGINEERING↗

Flow-Straightener Sleeve for Pump Valve

Flow-straightening sleeve contains vanes in modified honeycomb pattern. Each vane curved fluid-dynamic wing that helps straighten and smooth out flow of fluid passing over it. Sleeve performs more reliably and quietly, possibility of damage to internal valve parts greatly reduced, valve life expectancy increased and time between overhauls extended.

Tolpen, J.↗

Spatio-temporal patterning of extensile active stresses in microtubule-based active fluids

Abstract Microtubule-based active fluids exhibit turbulent-like autonomous flows, which are driven by the molecular motor powered motion of filamentous constituents. Controlling active stresses in space and time is an essential prerequisite for controlling the intrinsically chaotic dynamics of extensile active fluids. We design single-headed kinesin molecular motors that exhibit optically enhanced clustering and thus enable precise and repeatable spatial and temporal control of extensile active stresses. Such motors enable rapid, reversible switching between flowing and quiescent states. In turn, spatio-temporal patterning of the active stress controls the evolution of the ubiquitous bend instability of extensile active fluids and determines its critical length dependence. Combining optically controlled clusters with conventional kinesin motors enables one-time switching from contractile to extensile active stresses. These results open a path towards real-time control of the autonomous flows generated by active fluids.

36 MATERIALS SCIENCE↗

Global axisymmetric simulations of two-fluid reconnection in an experimentally relevant geometry

To address the interplay between local and global effects in magnetic reconnection, axisymmetric numerical simulations for the Magnetic Reconnection Experiment [M. Yamada et al., Phys. Plasmas 4, 1936 (1997)] are performed using the NIMROD code [C. R. Sovinec et al., J. Comput. Phys. 195, 355 (2004)]. The 'pull' and 'push' modes of the device are simulated both with and without two-fluid effects in the generalized Ohm's law. As in experiment, the pull reconnection rate is slowed due to the presence of downstream pressure associated with the outflow. Effects induced by toroidicity include a radially inward drift of the current sheet during pull reconnection and a radially outward displacement of the X-point during push reconnection. These effects result from the inboard side of the current sheet having less volume than the outboard side, facilitating the formation of large scale pressure gradients since the inboard side is more susceptible to a buildup or depletion of density. Toroidicity also leads to asymmetry of the quadrupole field during two-fluid simulations. During pull reconnection, the outboard lobes of the quadrupole typically peak close to the X-point, whereas the inboard quadrupole lobes peak near the flux core surfaces. At experimentally relevant parameters, the reconnection rate is found to depend more on the mode of operation than on the inclusion of two-fluid effects. The current sheet in two-fluid co-helicity simulations tilts due to a Lorentz force associated with the guide field and the outflowing electrons, resulting in asymmetric flow patterns for both ions and electrons. In two-fluid counter-helicity simulations, the Hall effect leads to a radial shift in position of the X-point and an asymmetric outflow pattern, which is examined in terms of separate force-density contributions. In general, asymmetry due to toroidicity or the Hall effect often leads to uneven outflow, which then feeds back on the reconnection process through large scale pressure gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical modeling of heat transfer in molten silicon during directional solidification process

Numerical investigation is performed for some of the thermal and fluid flow properties of silicon melt during directional solidification by numerical modeling. Dimensionless numbers are extremely useful to understand the heat and mass transfer of fluid flow on Si melt and control the flow patterns during crystal growth processes. The average grain size of whole crystal would increase when the melt flow is laminar. In the silicon growth process, the melt flow is mainly driven by the buoyancy force resulting from the horizontal temperature gradient. The thermal and flow pattern influences the quality of the crystal through the convective heat and mass transport. The computations are carried out in a 2D axisymmetric model using the finite-element technique. The buoyancy effect is observed in the melt domain for a constant Rayleigh number and for different Prandtl numbers. The convective heat flux and Reynolds numbers are studied in the five parallel horizontal cross section of melt silicon region. And also, velocity field is simulated for whole melt domain with limited thermal boundaries. The results indicate that buoyancy forces have a dramatic effect on the most of melt region except central part.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit inteference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

fluid shear stress micro sensor non-invasive senso↗