Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite

The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Registration of Cone-Beam Computer Tomography and Preprocedural Computer Tomography Aids in Localization of Adrenal Veins and Decreasing Radiation Dose in Adrenal Vein Sampling

PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectively compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement

IntroductionTo assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement.Materials and methodsAll consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated.ResultsSixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm{sup 2}, fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%).ConclusionThis study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using one display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A More Efficient, Radiation-Free Alternative to Systematic Chest X-Ray for the Detection of Embolized Seeds to the Lung

Purpose: To evaluate the efficacy of a seed-migration detector and to compare its performance to fluoroscopy and postoperative chest radiographs. Methods and Materials: A gamma scintillation survey meter was converted to a seed-migration detector by adding a shield on the probe detection window. The detector response to three {sup 125}I seed activities was characterized for different source-to-detector distances in water. The detector was used to perform a chest evaluation on 737 patients at their first postoperative visit. When the detector showed positive activity, seed migration was confirmed by taking a chest radiograph and by looking at the region with fluoroscopy. Results: One hundred and three patients (14.0%) presented at least one embolized seed. This accounts for 123 of the 39,887 seeds. Eighty-seven, 12, and 4 patients had respectively one, two, and three seed embolization. Compared with the seed-migration detector, detection based on fluoroscopy would have led to 13 false-negative detections (of 103, or 12.6%), and the radiograph would have resulted in 31 or 30.1%. More important, standard chest X-ray would have required a survey and extra radiation dose to lung to 100% of the patients, rather than the 14% who required it. Conclusions: The usual recommendation to perform chest radiographs at the first follow-up visit to scan lungs for embolized seeds should be revised because of the high false-negative rate. Scintillator-based gamma counter detector provides superior detection sensitivity and should be adopted as a standard of practice. Chest X-ray could be limited to documenting cases of positive migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years

This review covers the role of medical physics in addressing issues directly related to patient dosimetry in radiography, fluoroscopy, mammography, and CT. The sections on radiography and fluoroscopy radiation doses review the changes that have occurred during the last 50 to 60 years. A number of technological improvements have contributed to both a significant reduction in patient and staff radiation doses and improvements to the image quality during this period of time. There has been a transition from film-screen radiography with hand dip film processing to electronic digital imaging utilizing CR and DR. Similarly, fluoroscopy has progressed by directly viewing image intensifiers in darkened rooms to modern flat panel image receptor systems utilizing pulsed radiation, automated variable filtration, and digitally processed images. Mammography is one of the most highly optimized imaging procedures performed, because it is a repetitive screening procedure that results in annual radiation exposure. Mammography is also the only imaging procedure in the United States in which the radiation dose is regulated by the federal government. Consequently, many medical physicists have studied the dosimetry associated with screen-film and digital mammography. In this review, a brief history of mammography dose assessment by medical physicists is discussed. CT was introduced into clinical practice in the early 1970s, and has grown into one of the most important modalities available for diagnostic imaging. CT dose quantities and measurement techniques are described, and values of radiation dose for different types of scanner are presented. Organ and effective doses to adult patients are surveyed from the earliest single slice scanners, to the latest versions that include up to two x-ray tubes and can incorporate as many as 256 detector channels. An overview is provided of doses received by pediatric patients undergoing CT examinations, as well as methods, and results, of studies performed to assess the radiation absorbed by the conceptus of pregnant patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Unsupervised C-arm pose tracking with radiographic fiducial

Purpose: C-arm fluoroscopy reconstruction, such as that used in prostate brachytherapy, requires that the relative poses of the individual C-arm fluoroscopy images must be known prior to reconstruction. Radiographic fiducials can provide excellent C-arm pose tracking, but they need to be segmented in the image. The authors report an automated and unsupervised method that does not require prior segmentation of the fiducial. Methods: The authors compute the individual C-arm poses relative to a stationary radiographic fiducial of known geometry. The authors register a filtered 2D fluoroscopy image of the fiducial to its 3D model by using image intensity alone without prior segmentation. To enhance the C-arm images, the authors investigated a three-step cascade filter and a line enhancement filter. The authors tested the method on a composite fiducial containing beads, straight lines, and ellipses. Ground-truth C-arm pose was provided by a clinically proven method. Results: Using 111 clinical C-arm images and {+-}10 deg. and {+-}10 mm random perturbation around the ground-truth pose, a total of 2775 cases were evaluated. The average rotation and translation errors were 0.62 deg. (STD=0.31 deg.) and 0.72 mm (STD=0.55 mm) for the three-step filter and 0.67 deg. (STD=0.40 deg.) and 0.87 mm (STD=0.27 mm) using the line enhancement filter. Conclusions: The C-arm pose tracking method was sufficiently accurate and robust on human patient data for subsequent 3D implant reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biological effect of dose distortion by fiducial markers in spot-scanning proton therapy with a limited number of fields: A simulation study

Purpose: In accurate proton spot-scanning therapy, continuous target tracking by fluoroscopic x ray during irradiation is beneficial not only for respiratory moving tumors of lung and liver but also for relatively stationary tumors of prostate. Implanted gold markers have been used with great effect for positioning the target volume by a fluoroscopy, especially for the cases of liver and prostate with the targets surrounded by water-equivalent tissues. However, recent studies have revealed that gold markers can cause a significant underdose in proton therapy. This paper focuses on prostate cancer and explores the possibility that multiple-field irradiation improves the underdose effect by markers on tumor-control probability (TCP). Methods: A Monte Carlo simulation was performed to evaluate the dose distortion effect. A spherical gold marker was placed at several characteristic points in a water phantom. The markers were with two different diameters of 2 and 1.5 mm, both visible on fluoroscopy. Three beam arrangements of single-field uniform dose (SFUD) were examined: one lateral field, two opposite lateral fields, and three fields (two opposite lateral fields + anterior field). The relative biological effectiveness (RBE) was set to 1.1 and a dose of 74 Gy (RBE) was delivered to the target of a typical prostate size in 37 fractions. The ratios of TCP to that without the marker (TCP{sub r}) were compared with the parameters of the marker sizes, number of fields, and marker positions. To take into account the dependence of biological parameters in TCP model, {alpha}/{beta} values of 1.5, 3, and 10 Gy (RBE) were considered. Results: It was found that the marker of 1.5 mm diameter does not affect the TCPs with all {alpha}/{beta} values when two or more fields are used. On the other hand, if the marker diameter is 2 mm, more than two irradiation fields are required to suppress the decrease in TCP from TCP{sub r} by less than 3%. This is especially true when multiple (two or three) markers are used for alignment of a patient. Conclusions: It is recommended that 1.5-mm markers be used to avoid the reduction of TCP as well as to spare the surrounding critical organs, as long as the markers are visible on x-ray fluoroscopy. When 2-mm markers are implanted, more than two fields should be used and the markers should not be placed close to the distal edge of any of the beams.

60 APPLIED LIFE SCIENCES↗

A statistical method for retrospective cardiac and respiratory motion gating of interventional cardiac x-ray images

Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy. Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique. The principal component analysis (PCA) statistical method is used in combination with other image processing operations to make our proposed masked-PCA technique suitable for cardiorespiratory gating. Unlike many previously proposed techniques, our technique is robust to varying image-content, thus it does not require specific catheters or any other optically opaque structures to be visible. Therefore, it works without any knowledge of catheter geometry. The authors demonstrate the application of our technique for the purposes of retrospective cardiorespiratory gating of normal and very low dose x-ray fluoroscopy images. Results: For normal dose x-ray images, the algorithm was validated using 28 clinical electrophysiology x-ray fluoroscopy sequences (2168 frames), from patients who underwent radiofrequency ablation (RFA) procedures for the treatment of atrial fibrillation and cardiac resynchronization therapy procedures for heart failure. The authors established end-systole, end-expiration, and end-inspiration success rates of 97.0%, 97.9%, and 97.0%, respectively. For very low dose applications, the technique was tested on ten x-ray sequences from the RFA procedures with added noise at signal to noise ratio (SNR) values of√(5)0, √(1)0, √(8), √(6), √(5), √(2), and √(1) to simulate the image quality of increasingly lower dose x-ray images. Even at the low SNR value of √(2), representing a dose reduction of more than 25 times, gating success rates of 89.1%, 88.8%, and 86.8% were established. Conclusions: The proposed technique can therefore extract useful information from interventional x-ray images while minimizing exposure to ionizing radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-05: Design and Geometric Validation of An Externally and Internally Deformable, Programmable Lung Motion Phantom

Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.

60 APPLIED LIFE SCIENCES↗

An externally and internally deformable, programmable lung motion phantom

Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commercially available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.25 mm RMS error. The motion trajectories of internal and external radio-opaque markers as measured by fluoroscopy were found to be highly correlated (R > 0.95). Using the phantom, it was demonstrated that the motion trajectories of regions-of-interest on the surface as measured by VisionRT are highly consistent with corresponding fluoroscopically acquired surface marker trajectories, with RMS errors within 0.26 mm. Furthermore, it was shown that the trajectories of external and internal marker trajectories derived from NiftyReg deformation vector fields were within 1 mm root mean square errors comparing to trajectories obtained by segmenting markers from individual fluoro frames. Finally, it was shown that while 4DCT can be used to localize internal markers for sinusoidal motion with reasonable accuracy, the localization error increases significantly (by a factor of ∼2) in the presence of cycle-to-cycle variations that are observed in patient-derived respiratory motion. Conclusions: The authors have developed a realistic externally and internally deformable, programmable lung phantom that will serve as a valuable tool for clinical and investigational motion management studies in thoracic and abdominal radiation therapies.

60 APPLIED LIFE SCIENCES↗

Direct-conversion flat-panel imager with avalanche gain: Feasibility investigation for HARP-AMFPI

The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rushing photoconductor (HARP) in which the charge undergoes avalanche multiplication. An active matrix of thin film transistors is used to read out the electronic image. The authors call the proposed imager HARP active matrix flat panel imager (HARP-AMFPI). The key advantages of HARP-AMFPI are its high spatial resolution, owing to the direct-conversion a-Se layer, and its programmable avalanche gain, which can be enabled during low dose fluoroscopy to overcome electronic noise and disabled during high dose radiography to prevent saturation of the detector elements. This article investigates key design considerations for HARP-AMFPI. The effects of electronic noise on the imaging performance of HARP-AMFPI were modeled theoretically and system parameters were optimized for radiography and fluoroscopy. The following imager properties were determined as a function of avalanche gain: (1) the spatial frequency dependent detective quantum efficiency; (2) fill factor; (3) dynamic range and linearity; and (4) gain nonuniformities resulting from electric field strength nonuniformities. The authors results showed that avalanche gains of 5 and 20 enable x-ray quantum noise limited performance throughout the entire exposure range in radiography and fluoroscopy, respectively. It was shown that HARP-AMFPI can provide the required gain while maintaining a 100% effective fill factor and a piecewise dynamic range over five orders of magnitude (10{sup -7}-10{sup -2} R/frame). The authors have also shown that imaging performance is not significantly affected by the following: electric field strength nonuniformities, avalanche noise for x-ray energies above 1 keV and direct interaction of x rays in the gain region. Thus, HARP-AMFPI is a promising flat-panel imager structure that enables high-resolution fully quantum noise limited x-ray imaging over a wide exposure range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transnasal stent-assisted targeting technique for percutaneous jejunostomy placement in patients with hiatal hernias

Purpose: To report the transnasal stent-assisted targeting technique for percutaneous jejunostomy placement in patients with hiatal hernias. Materials and methods: Four patients, including three (75%) females and one (25%) male, with mean age of 77.5 years (range 73–78 years), and with a hiatal hernia and intrathoracic stomach precluding gastrostomy placement and loop snare placement into the mid-jejunum underwent the transnasal stent-assisted targeting technique for percutaneous jejunostomy placement. In all patients, a duodenal stent was inserted into the jejunum in a transnasal fashion. The stent was partially unsheathed in an anterior loop of jejunum and percutaneously targeted using an 18-gauge needle through which a guidewire was advanced, trapped within the stent, and removed through the nose. The tract was serially dilated and a jejunostomy was placed. Technical success, procedure time, fluoroscopy time, radiation exposure, complications, time to enteral feeding, and follow-up were recorded. Results: Technical success was 100% (4/4) with all four patients requiring only one needle pass before successful jejunal cannulation. Mean procedure time was 108 min. Mean fluoroscopy time was 44 min. Mean dose area product was 3969.3 μGym{sup 2}. No minor or major complications occurred. All four patients received enteral feeding one day after the procedure. Mean follow-up was 366 days. Conclusion: The transnasal stent-assisted targeting technique is a novel method for primary jejunostomy placement in patients with hiatal hernias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Extraspinal Painful Bone Metastases with Percutaneous Cementoplasty: A Prospective Study of 50 Patients

The aim of this study was to assess the efficacy of percutaneous cementoplasty (PC) with polymethylmethacrylate (PMMA) in painful extravertebral lytic bone metastases not responding to conventional therapy. Fifty patients (25 females), mean age 64.7 {+-} 11.2 years, underwent PC after giving informed consent. Procedures were performed under fluoroscopy (1/50) or combined fluoroscopy-CT (49/50) guidance in local anesthesia or under deep sedation in 7 patients with large metastases who underwent radiofrequency thermoablation (RFA) in the same session. Seventy lesions were treated (1-6 per patient; average, 1.4 {+-} 0.9), arranging in size from 1 to 10 cm (average, 3.6 {+-} 2.1 cm). Mean volume of PMMA per lesion was 5.9 {+-} 3.2 ml (range, 1.5-15.0 ml). Pain was prospectively evaluated on an 11-point visual analog scale (VAS) before and after the procedure (follow-up, 15 to 36 months). Mean VAS score dropped from 9.1 {+-} 1.2 (range: 6-10) to 2.1 {+-} 2.5 (range: 0-9). Mean VAS difference was 7.0 {+-} 2.3 (range, 1-10; p < 0.0001, Wilcoxon signed rank test). Forty-seven of the 50 patients (94%) suspended narcotic drugs, in 22 (44%) pain was controlled with a nonsteroidal anti-inflammatory drug, in 25 (50%) analgesic therapy was suspended, and 13 of 50 (26%) had complete pain regression. In 3 of the 50 patients (6%) pain was not improved. No statistical difference between osteoplasty and osteoplasty plus RFA was found (p = 0.8338, Mann-Whitney test). No complications arose during the procedure. Two patients with metastases in the femoral diaphysis reported a fracture 1 month after treatment. PC is effective to obtain pain regression in painful bone metastases not responding to conventional analgesic therapy; bone consolidation cannot be obtained in the diaphysis of long weight-bearing bones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗