Search NASA⌕ Search

SEARCH · Search NASA

Results for “FTS spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Raman spectroscopy of gases with a Fourier transform spectrometer - The spectrum of D2

Fourier transform spectrometry (FTS) is presently used to record the spontaneous incoherent laser Raman spectra of gases. The high resolution, sensitivity, calibration accuracy and spectral coverage achieved demonstrate the viability of FTS for Raman spectroscopy. Attention is given to the coefficients obtained by fitting measurements obtained from the spectrum of D2, containing both v = 0-0 and 1-0 transitions, to the Dunham (1932) expansion of the vibration-rotation energy levels.

Jennings, D. E.↗

Spectral characterization and performance of SPT-SLIM on-chip filterbank spectrometers

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) experiment is a pathfinder for demonstrating the use of on-chip spectrometers for millimeter (mm) Line Intensity Mapping (LIM). We present spectral bandpass measurements of the SPT-SLIM spectrometer channels made on site using a Fourier Transform Spectrometer during the first deployment of SPT-SLIM in the 2024-2025 Austral summer season. We note the effect of FTS systematics on measurements of on-chip filterbank spectrometer resolutions and demonstrate a technique for measuring the narrow band passes of the SPT-SLIM filterbanks that improves beyond the intrinsic resolution of a Fourier Transform Spectrometer.

Benson, C. S. [Cardiff U.]↗

An On-Chip Superconducting Kinetic Inductance Fourier Transform Spectrometer for Millimeter-Wave Astronomy

An on-chip FTS consists of two waveguides coupled to long superconducting transmission lines (STLs) (similar to 620 mm) using two coupling probes. The signal propagating on one of the STLs is phase-shifted with respect to the other line with a bias current that affects the nonlinear dependence of kinetic inductance, Lk(I)of the STL material. Here we describe the design and simulation of a superconducting on-chip FTS coupled to a dual polarization W-band (90-110 GHz) waveguide. These devices have applications in ground-based and space-based millimeter-wave spectral surveys.

Fourier transform spectrometer↗

A Spectral Atlas of the Nu(sub 12) Fundamental of (13)C(12)CH6 in the 12 Micron Region

The recent discovery of the minor isotopomer of ethane, (13)C(12)CH6, in the planetary atmospheres of Jupiter and Neptune, added ethane to the molecules which can be used to determine isotopic (12)C(12)C ratios for the jovian planets. The increased spectral resolution and coverage of the IR and far-IR instruments to be carried on the Cassini mission to Saturn and Titan may enable the detection of the minor isotopomer. Accurate frequency and cross-section measurements of the nu(sub 12) fundamental under controlled laboratory condition are important to interpret current and future planetary spectra. High resolution spectra of the minor isotopomer (13)C(12)CH6 have been recorded in the 12.2 micron region using the Kitt Peak Fourier Transform (FTS) and the Goddard Tunable Diode Laser spectrometer (TDL). In a global fit to 19 molecular constants in a symmetric top Hamiltonian, transition frequencies of the nu(sub 12) fundamental ranging up to J=35 and K=20 have been determined with a standard deviation of less than 0.0005 cm(exp -1). From selected line intensity measurements, a vibrational dipole moment for the nu(sub 12) fundamental has been derived. Observed and calculated spectra covering the region from 740 cm(exp -1) and to 910 cm(exp -1) are presented. A compilation of transition frequencies, line intensities, and lower state energies are included for general use in the astronomical community.

Weber, Mark↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

The NSO FTS database program and archive (FTSDBM)

Data from the NSO Fourier transform spectrometer is being re-archived from half inch tape onto write-once compact disk. In the process, information about each spectrum and a low resolution copy of each spectrum is being saved into an on-line database. FTSDBM is a simple database management program in the NSO external package for IRAF. A command language allows the FTSDBM user to add entries to the database, delete entries, select subsets from the database based on keyword values including ranges of values, create new database files based on these subsets, make keyword lists, examine low resolution spectra graphically, and make disk number/file number lists. Once the archive is complete, FTSDBM will allow the database to be efficiently searched for data of interest to the user and the compact disk format will allow random access to that data.

Lytle, D. M.↗

Geostationary Imaging FTS (GIFTS) Data Processing: Measurement Simulation and Compression

GIFTS (Geostationary Imaging Fourier Transform Spectrometer), a forerunner of next generation geostationary satellite weather observing systems, will be built to fly on the NASA EO-3 geostationary orbit mission in 2004 to demonstrate the use of large area detector arrays and readouts. Timely high spatial resolution images and quantitative soundings of clouds, water vapor, temperature, and pollutants of the atmosphere for weather prediction and air quality monitoring will be achieved. GIFTS is novel in terms of providing many scientific returns that traditionally can only be achieved by separate advanced imaging and sounding systems. GIFTS' ability to obtain half-hourly high vertical density wind over the full earth disk is revolutionary. However, these new technologies bring forth many challenges for data transmission, archiving, and geophysical data processing. In this paper, we will focus on the aspect of data volume and downlink issues by conducting a GIFTS data compression experiment. We will discuss the scenario of using principal component analysis as a foundation for atmospheric data retrieval and compression of uncalibrated and un-normalized interferograms. The effects of compression on the degradation of the signal and noise reduction in interferogram and spectral domains will be highlighted. A simulation system developed to model the GIFTS instrument measurements is described in detail.

Huang, Hung-Lung↗

Spectroscopic Capabilities and Possibilities of the Far Infrared and Submillimeter Telescope Mission

The Far Infrared and Submillimeter Telescope (FIRST) mission is the fourth European Space Agency corner stone mission. FIRST will be an observatory with a passively cooled (80 Kelvin) 3.5 meter class telescope and three cryogenic instruments covering the 670 to 80 mm spectral region. The mission is slated for a 4.5 year operational lifetime in an L2 orbit. It will share an Arian 5 launch with PLANCK in early 2007. The three payload instruments include the Spectral and Photometric Imaging Receiver (SPIRE), which is a bolometer array with Martin-Puplett FTS for 200-670 microns, the Photoconductor Array Camera and Spectrometer (PACS), which is a photoconductor array with a grating spectrometer for 80-210 microns and the Heterodyne Instrument for FIRST (HIFI), which is a series of seven heterodyne receivers covering 480-1250 GHz and portions of 1410-1910 GHz and 2400-2700 GHz. FIRST will make many detailed spectral surveys of a wide variety of objects previously obscured by the atmosphere and in regions of the spectrum seldom used for astronomical observations, With all of the spectroscopic capability on FIRST a great deal of laboratory spectroscopic support will be needed for accurate interpretation of the spectral data.

Pearson, J. C.↗

Hydrogen-Broadened Water from 50 to 300 cm-1 and 1300 to 4000 cm-1

To support remote sensing of the outer planets, absorption spectra of H2O broadened by H2 were recorded at room temperature using two Fourier transform spectrometers. The data from 1300 to 4000 cm-1 were obtained at 0.012 cm-1 resolution with the McMath FTS located at Kitt Peak National Observatory/National Solar Observatory. The remainder of the spectral data from 55 to 320 cm-1 were taken at 0.0056 cm-1 with the Bruker FTS.

remote sensing outer planets absorption spectra Fo↗

Passive tilt compensation in an FTS using a double-sided flat retroflector

An optical configuration for a tilt-compensated Fourier transform spectrometer is presented. An expanded and collimated He-Ne laser beam was passed through the interferometer and the collimated output was observed visually. The double-sided mirror was tilted through angles approaching 1 deg with no apparent degradation in the interference quality.

Jennings, Donald E.↗

TES Level 1 Algorithms: Interferogram Processing, Geolocation, Radiometric, and Spectral Calibration

The Tropospheric Emission Spectrometer (TES) on the Earth Observing System (EOS) Aura satellite measures the infrared radiance emitted by the Earth's surface and atmosphere using Fourier transform spectrometry. The measured interferograms are converted into geolocated, calibrated radiance spectra by the L1 (Level 1) processing, and are the inputs to L2 (Level 2) retrievals of atmospheric parameters, such as vertical profiles of trace gas abundance. We describe the algorithmic components of TES Level 1 processing, giving examples of the intermediate results and diagnostics that are necessary for creating TES L1 products. An assessment of noise-equivalent spectral radiance levels and current systematic errors is provided. As an initial validation of our spectral radiances, TES data are compared to the Atmospheric Infrared Sounder (AIRS) (on EOS Aqua), after accounting for spectral resolution differences by applying the AIRS spectral response function to the TES spectra. For the TES L1 nadir data products currently available, the agreement with AIRS is 1 K or better.

infrared remote sensing↗

The No Vibrational Fundamental Band: Temperature Dependence of N2-Broadening Coefficients

Rovibrational spectra of the vibrational fundamental of nitric oxide have been recorded under N2-broadening conditions at 0.0056 cm(exp-1) resolution using the Solar McMath FTS at the Kitt Peak National Observatory. The temperature range for the experiments was 296 K to 183 K. The 30 cm absorption cell used for the measurements is cooled with a helium compressor and can operate at temperatures down to 60 K; vibration isolation of the cell allows its use with high performance Fourier Transform Spectrometers. From these spectra, N2-broadened line widths have been determined thru m = 16.5. Qualitative as well as quantitative discrepancies are observed between our experimental determinations of the temperature dependence of the broadening and theoretical calculations.

Spencer, M. N.↗

Optical-Path-Difference Linear Mechanism for the Panchromatic Fourier Transform Spectrometer

A document discusses a mechanism that uses flex-pivots in a parallelogram arrangement to provide frictionless motion with an unlimited lifetime. A voicecoil actuator drives the parallelogram over the required 5-cm travel. An optical position sensor provides feedback for a servo loop that keeps the velocity within 1 percent of expected value. Residual tip/tilt error is compensated for by a piezo actuator that drives the interferometer mirror. This mechanism builds on previous work that targeted ground-based measurements. The main novelty aspects include cryogenic and vacuum operation, high reliability for spaceflight, compactness of the design, optical layout compatible with the needs of an imaging FTS (i.e. wide overall field-of-view), and mirror optical coatings to cover very broad wavelength range (i.e., 0.26 to 15 m).

Blavier, Jean-Francois L.↗

Image Stability Requirements For a Geostationary Imaging Fourier Transform Spectrometer (GIFTS)

A Geostationary Imaging Fourier Transform Spectrometer (GIFTS) has been selected for the NASA New Millennium Program (NMP) Earth Observing-3 (EO-3) mission. Our paper will discuss one of the key GIFTS measurement requirements, Field of View (FOV) stability, and its impact on required system performance. The GIFTS NMP mission is designed to demonstrate new and emerging sensor and data processing technologies with the goal of making revolutionary improvements in meteorological observational capability and forecasting accuracy. The GIFTS payload is a versatile imaging FTS with programmable spectral resolution and spatial scene selection that allows radiometric accuracy and atmospheric sounding precision to be traded in near real time for area coverage. The GIFTS sensor combines high sensitivity with a massively parallel spatial data collection scheme to allow high spatial resolution measurement of the Earth's atmosphere and rapid broad area coverage. An objective of the GIFTS mission is to demonstrate the advantages of high spatial resolution (4 km ground sample distance - gsd) on temperature and water vapor retrieval by allowing sampling in broken cloud regions. This small gsd, combined with the relatively long scan time required (approximately 10 s) to collect high resolution spectra from geostationary (GEO) orbit, may require extremely good pointing control. This paper discusses the analysis of this requirement.

Bingham, G. E.↗

Development of a Submillimeter-Wavelength Immersion Grating Spectrometer

The broad goal of this project was to develop a broadband, moderate-resolution spectrometer for submillimeter wavelengths. Our original approach was to build an immersion grating spectrometer, and as such, the first step was to identify the best material (lowest loss, highest index) for the grating medium, and to characterize its properties at the foreseen optical-bench operating temperature of 1.5 K. To this end, we put our initial efforts into upgrading an existing laboratory submillimeter Fourier transform spectrometer, which allowed us to carry out the requisite materials measurements. The associated cryogenic detector dewar was also redesigned and rebuilt to carry out this work. This dewar houses the 1.5 K detector and the filter wheel used in the materials characterization. Our goal was to have the beam propagate through the samples as uniformly as possible, so the optics were redesigned to allow for the samples to be traversed by a well-defined collimated beam. The optics redesign also placed the samples at an image of the aperture stop located within the FTS. After the rebuild, we moved into the testing phase.

Phillips, T. G.↗