Effects of blade-vane ratio and rotor-stator spacing of fan noise with forward velocity

A research fan stage was acoustically tested in an anechoic wind tunnel with a 41 m/sec tunnel flow. Two stator vane numbers giving cut-on and cut-off conditions were tested at three rotor-stator spacings ranging from about 0.5 to 2.0 rotor chords. These two stators were designed for similar aerodynamic performance. Hot film anemometer turbulence measurements were made at the leading edge of the stator for each spacing. The cut-off criterion strongly controlled the fundamental tone level at all spacings. The trends with spacing of the wake defect upwash component at the stator tip showed good agreement with the corresponding cut-on acoustic tone levels.

Woodward, R. P.↗

Effects of blade-vane ratio and rotor-stator spacing on fan noise with forward velocity

A research fan stage is acoustically tested in an anechoic wind tunnel with a 41 m/sec tunnel flow. Two stator vane numbers giving cut-on and cut-off conditions are tested at three rotor stator spacings ranging from 0.5 to 2.0 rotor chords. Hot-film anemometer turbulence measurements are made at the leading edge of the stator for each spacing, and a crossed film anemometer is radially transversed to define streamwise and upwash characteristics of the rotor blade wakes. Trends in the acoustic results are observed in the front and aft quadrants at 80% design fan speed. Aft quadrant results demonstrate a fundamental tone 9 dB lower for the 25 vane stator than for the 11 vane stator, while overtone levels are 3 dB higher. The cut-off criterion strongly controls fundamental tone level at all spacings, and spacing trends of the wake-defect upwash component show good agreement with corresponding cut-on acoustic tone levels.

Woodward, R. P.↗

A compact inflow control device for simulating flight fan noise

Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.

Homyak, L.↗

A compact inflow control device for simulating flight fan noise

Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.

Homyak, L.↗

Effects of Simulated Flight on Fan Noise Suppression

Attenuation properties of three treated fan inlets were evaluated. Tunnel flow simulated the inflow clean-up effect on source noise observed in flight and allowed observation of the blade passage frequency tone cut-off phenomenon. Acoustic data consisted of isolated inlet noise measured in the far field at two fixed positions and with traverses at four frequencies. Attenuation and source noise properties with and without flight simulation are compared and discussed. Averaged attenuation properties showed relative agreement of the inlets with their design intent, however, tunnel flow significantly affected the attenuation spectra.

Heidmann, M. F.↗

Fan Noise Prediction

Aircraft noise emission level restrictions in and around airports continue to grow more stringent every few years. Thus, it is important to predict noise emissions from aircraft accurately. Predicting noise from the engine(s) is an integral part of the efforts to characterize the noise signature of an aircraft. An important source of engine noise is the rotor-stator interaction noise produced as a result of impingement of fan rotor wakes on the fan exit guide vanes. Interaction noise propagates through the inlet and exhaust ducts of the engine and radiates to the far field. noise levels for a range of model fans stages that represent current aircraft engine designs. Eversman's radiation codes calculate both the inlet and exhaust noise radiation by propagating the internally measured rotor-stator interaction noise to the far field. Predicted far field sound pressure levels are then compared to the measured levels from wind tunnel tests. This effort's objective is to prove that the predicted levels actually describe the measured levels.

France, Joshua I.↗

Reduction of fan noise: A concept

Acoustic materials strategically located within or near noise sources are effective for noise abatement on wing mounted lift fans, nozzles, engines and other noise sources. Panels are straightforward and easily adaptable to situations outside of aircraft technology.

Simonson, M. R.↗

Non-linear duct acoustics and its application to fan noise

Quite often the scalar Helmholtz equation is assumed to be the fundamental equation of duct acoustics and various relations are derived from it. An investigation is, therefore, conducted regarding the underlying assumptions leading to the Helmholtz equation. It is found that serious errors, even well below 186 dB, are possible if the assumption of linearity were to be made. In duct acoustics these errors are highest near the cutoff points and in the case of ducts with transonic flow. It is pointed out that serious errors could arise if a nonlinear problem is analyzed by linear methods. At times, an entire phenomenon remains unpredictable by linear methods. Attention is given to the characteristics of nonlinear systems, the phenomenon of multiple pure tones in the case of noise from the aircraft engine fans, the limitations of the conventional acoustics equation, duct shape and nonlinearity, and the numerical simulation of a fan with 8 blades.

Vaidya, P. G.↗

Active control of fan noise from a turbofan engine

A three channel active control system is applied to an operational turbofan engine in order to reduce tonal noise produced by both the fan and high pressure compressor. The control approach is the feedforward filtered-x least-mean-square algorithm implemented on a digital signal processing board. Reference transducers mounted on the engine case provides blade passing and harmonics frequency information to the controller. Error information is provided by large area microphones placed in the acoustic far field. In order to minimize the error signal, the controller actuates loudspeakers mounted on the inlet to produce destructive interference. The sound pressure level of the fundamental tone of the fan was reduced using the three channel controller by up to 16 dB over a 60 deg angle about the engine axis. A single channel controller could produce reduction over a 30 deg angle. The experimental results show the control to be robust. Simultaneous control of two tones is done with parallel controllers. The fundamental and the first harmonic tones of the fan were controlled simultaneously with reductions of 12 dBA and 5 dBA, respectively, measured on the engine axis. Simultaneous control was also demonstrated for the fan fundamental and the high pressure compressor fundamental tones.

Thomas, Russell H.↗

Active control of fan noise from a turbofan engine

A three-channel active control system is applied to an operational turbofan engine to reduce tonal noise produced by both the fan and the high-pressure compressor. The control approach is the feedforward filtered-x least-mean-square algorithm implemented on a digital signal processing board. Reference transducers mounted on the engine case provide blade passing and harmonics frequency information to the controller. Error information is provided by large area microphones placed in the acoustic far field. To minimize the error signal, the controller actuates loudspeakers mounted on the inlet to produce destructive interference. The sound pressure level of the fundamental tone of the fan was reduced using the three-channel controller by up to 16 dB over a +/- 30-deg angle about the engine axis. A single-channel controller could produce reduction over a +/- 15-deg angle. The experimental results show the control to be robust. Outside of the areas contolled, the levels of the tone actually increased due to the generation of radial modes by the control sources. Simultaneous control of two tones is achieved with parallel controllers. The fundamental and the first harmonic tones of the fan were controlled simultaneously with reductions of 12 and 5 dBA, respectively, measured on the engine axis. Simultaneous control was also demonstrated for the fan fundamental and the high-pressure compressor fundamental tones.

Thomas, Russell H.↗

Fan Noise Source Diagnostic Test: Rotor Alone Aerodynamic Performance Results

The aerodynamic performance of an isolated fan or rotor alone model was measured in the NASA Glenn Research Center 9- by 15- Foot Low Speed Wind Tunnel as part of the Fan Broadband Source Diagnostic Test conducted at NASA Glenn. The Source Diagnostic Test was conducted to identify the noise sources within a wind tunnel scale model of a turbofan engine and quantify their contribution to the overall system noise level. The fan was part of a 1/5th scale model representation of the bypass stage of a current technology turbofan engine. For the rotor alone testing, the fan and nacelle, including the inlet, external cowl, and fixed area fan exit nozzle, were modeled in the test hardware; the internal outlet guide vanes located behind the fan were removed. Without the outlet guide vanes, the velocity at the nozzle exit changes significantly, thereby affecting the fan performance. As part of the investigation, variations in the fan nozzle area were tested in order to match as closely as possible the rotor alone performance with the fan performance obtained with the outlet guide vanes installed. The fan operating performance was determined using fixed pressure/temperature combination rakes and the corrected weight flow. The performance results indicate that a suitable nozzle exit was achieved to be able to closely match the rotor alone and fan/outlet guide vane configuration performance on the sea level operating line. A small shift in the slope of the sea level operating line was measured, which resulted in a slightly higher rotor alone fan pressure ratio at take-off conditions, matched fan performance at cutback conditions, and a slightly lower rotor alone fan pressure ratio at approach conditions. However, the small differences in fan performance at all fan conditions were considered too small to affect the fan acoustic performance.

Hughes, Christopher E.↗

Analytical Lift Fan Noise Study

Based on reasonable estimates of flow conditions occurring in an axial fan, acoustic radiation from various noise sources is evaluated. Results of computations on two specific fans are presented, and relative significance of the various sources is examined.

Rao, G. V. R.↗

Some observations about the components of transonic fan noise from narrow-band spectral analysis

Qualitative and quantitative spectral analyses are presented that give the broadband-noise, discrete-tone, and multiple-tone properties of the noise generated by a full-scale high-bypass single-stage axial-flow transonic fan (fan B, NASA Quiet Engine Program). The noise components were obtained from narrow-band spectra in conjunction with 1/3-octave-band spectra. Variations in the pressure levels of the noise components with fan speed, forward-quadrant azimuth angle, and frequency are presented and compared. The study shows that much of the apparent broadband noise on 1/3-octave-band plots consists of a complex system of shaft-order tones. The analyses also indicate the difficulties in determining or defining noise components, especially the broadband level under the discrete tones. The sources which may be associated with the noise components are discussed.

Saule, A. V.↗

Analytical parametric investigation of low pressure ratio fan noise

The results of an analytical study are reported which shows the effect of various physical and operating parameters on noise produced by low pressure ratio propulsive fans operating at subsonic top speeds. Acoustical duct lining effects are included in the study. The concepts used to develop the noise theory used in the study, as well as the correlation between the theory and model test results are also presented. It is shown that good correlation has been established between theory and experiment. Using the theory, it is shown that good aerodynamic design, maximum acceptable fan solidity, low tip speed operation and use of few blades and vanes leads to the lowest noise levels. Typical results of the study indicate that a fan operating at 1.2 fan pressure ratio and 700 ft/second tip speed with 12 blades and 7 vanes and including modest acoustic treatment on the duct wall would produce levels allowing a 100,000 lb. STOL aircraft to meet a noise level objective of 95 PNdB at 500 ft at takeoff.

Metzger, F. B.↗

Use of leaning vanes for fan noise reduction.

The obliquity of blade-vane interactions in an axial fan and its influence on noise generation are examined. Analysis indicates that leaning vanes decrease the amplitudes of the fluctuating pressures at the rotor-stator plane and modify the radial distribution. These changes lead to considerable cancellation in the near field and consequent reduction in radiated acoustic power. Acoustic measurements on a small scale fan with radial and leaning vanes compare favorably with analytical predictions.

Rao, G. V. R.↗

Effects of vane/blade ratio and spacing on fan noise, volume 1

The noise characteristics of a high-speed fan were studied. The experimental investigation was carried out on a 50.8 cm (20 in.) diameter scale model fan stage in an anechoic chamber with an inflow turbulence control screen installed. The forty-four blade rotor was tested with forty-eight vane and eighty-six vane stator rows, over a range of aixal rotor-stator spacings from 0.5 to 2.3 rotor tip chords. A two-dimensional strip theory model of rotor-stator interaction noise was employed to predict the measured tone power level trends, and good overall agreement with measured trends was obtained.

Gliebe, P. R.↗

Fan noise suppression

The principal suppressor parameters and their relationships have been used to formulate a suppressor design methodology which has been applied to the design of several full-scale suppressors. Tests of these suppressors on several full-scale fans have demonstrated noise reductions of the order of 10 PNdB. The amount of suppression in several instances seems to have been limited by reaching noise floors that are not clearly at the estimated jet noise level but are not far above it. In addition to identifying noise floors, two other areas are considered. The first is attenuation by the fan exhaust suppressors, which seems in most cases to be less than that of the inlet. The second is the effectiveness of outer cowl treatment alone on multiple pure tones. This question relates to whether a high-speed fan can become as quiet as a low-speed fan without a substantial increase in the amount of treatment.

Feiler, C. E.↗