First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Member of the Fast and Furious Family: A Relativistic and Time-variable UV Outflow in a Luminous Quasar

We report the fastest quasar outflow first detected in the ultraviolet, via variable C IV and Si IV absorption at outflow velocities −77,000 km s −1 to at least −90,000 km s −1 , in the radio-quiet quasar SDSS J231854.31+243954.2 (J2318). J2318 is a weak-lined quasar in the rest-frame ultraviolet, but Gemini GNIRS spectroscopy reveals an Hα redshift of z = 2.6781 ± 0.0004. A 20 yr photometric time series shows peak-to-peak variability of 0.5 mag in the g band. The C IV outflow strengthened monotonically over three epochs spanning ∼2.2 rest-frame years. The existence of such a high-velocity outflow implies that models of quasar outflows must be able to either accelerate gas to 0.3c while still preserving C IV and Si IV ions, or enable the formation of C IV and Si IV ions in gas, which has been accelerated to 0.3c. Virial estimates reveal a black-hole mass of 1.65 × 10 9 M ⊙ , which leads to an Eddington luminosity and Eddington ratio of 2.4 × 10 47 erg s −1 and 0.45, respectively. Using very conservative assumptions, the UV-absorbing outflow alone has an estimated mass loss of >0.82 M ⊙ yr −1 and a kinetic luminosity ratio L kin /L bol ≥ 0.75%. The lower limit is just above the threshold usually cited for significant feedback on the host galaxy. Comparison to PDS 456, the only other known quasar with a UV-absorbing outflow at 0.3c, suggests that the true $\dot{M}$ and Lkin/Lbol could be up to 2 orders of magnitude larger.

Seaton, Lucas M. [York University] (ORCID:00090006↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

OpenUniverse2024: a shared, simulated view of the sky for the next generation of cosmological surveys

The OpenUniverse2024 simulation suite is a cross-collaboration effort to produce matched simulated imaging for multiple surveys as they would observe a common simulated sky. Both the simulated data and associated tools used to produce it are intended to uniquely enable a wide range of studies to maximize the science potential of the next generation of cosmological surveys. We have produced simulated imaging for approximately 70 deg 2 of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Wide-Fast-Deep survey and the Nancy Grace Roman Space Telescope High-Latitude Wide-Area Survey, as well as overlapping versions of the ELAIS-S1 Deep-Drilling Field for LSST and the High-Latitude Time-Domain Survey for Roman. OpenUniverse2024 includes (i) an early version of the updated extragalactic model called Diffsky, which substantially improves the realism of optical and infrared photometry of objects, compared to previous versions of these models; (ii) updated transient models that extend through the wavelength range probed by Roman and Rubin; and (iii) improved survey, telescope, and instrument realism based on up-to-date survey plans and known properties of the instruments. It is built on a new and updated suite of simulation tools that improves the ease of consistently simulating multiple observatories viewing the same sky. The approximately 400 TB of synthetic survey imaging and simulated universe catalogs are publicly available, and we preview some scientific uses of the simulations.

large-scale structure of Universe↗

Ion-rich Acceleration during an Eruptive Flux Rope Event in a Multiple Null-point Configuration

We report on the γ-ray emission above 100 MeV from the GOES M3.3 flare SOL2012-06-03. The hard X-ray (HXR) and microwave emissions have typical time profiles with a fast rise to a well-defined peak followed by a slower decay. The >100 MeV emission during the prompt phase displayed a double-peaked temporal structure with the first peak following the HXR and microwaves, and the second one, about 3 times stronger, occurring 17 ± 2 s later. The time profiles seem to indicate two separate acceleration mechanisms at work, where the second γ-ray peak reveals a potentially pure or at least largely dominant ion acceleration. The Atmospheric Imaging Assembly imaging shows a bright elliptical ribbon and a transient brightening in the northwestern (NW) region. Nonlinear force-free extrapolations at the time of the impulsive peaks show closed field lines connecting the NW region to the southeastern part of the ribbon, and the magnetic topology revealed clusters of nulls. These observations suggest a spine-and-fan geometry, and based on these observations, we interpret the second γ-ray peak as being due to the predominant acceleration of ions in a region with multiple null points. The >100 MeV emission from this flare also exhibits a delayed phase with an exponential decay of roughly 350 s. We find that the delayed emission is consistent with ions being trapped in a closed flux tube with gradual escape via their loss cone to the chromosphere.

Pesce-Rollins, Melissa [Istituto Nazionale di Fisi↗

Advancing Li-plating detection: Motivating a multi-signal correlation approach

Facilitating fast charging in lithium-ion batteries (LiBs) is often linked to Li-plating, which harms performance, longevity, and safety. Early detection of Li-plating is essential for rapid technological development and for preventing performance deterioration and ensuring safety during operation. Fast and real-time detection, using commonly collected measurements like voltage (V), current (I), temperature (T), and pressure (P), is highly desirable. Existing standalone methods relying on electrochemical and mechanical signatures, using half, smaller, or specially designed cells often operated at lower temperatures, fail to account for real-world fast-charging conditions. These signatures may also have inherent unreliability in aged LiBs, a phenomenon currently not-well understood. All these uncertainties have complicated practical implementation of a robust Li-plating detection technique. This study, through multiple case studies involving real-world fast-charging conditions using automotive-grade 11.6 Ah LiBs, shows that many single signal-based diagnostic techniques may be inadequate to detect Li-plating. Among various signatures, end-of-charge rest pressure, differential pressure-sensing, and end-of-charge rest voltage were identified as particularly useful in detecting Li-plating. Furthermore, A multi-signal-based detection technique is shown to be more robust in detecting Li-plating. Using both fresh and aged cells, the results and analysis highlight how detection capabilities are influenced by various factors, including battery design, size, charging speed, operating temperature, and degradation level. Adopting such a multi-signal Li-plating detection approach may be instrumental in the rapid development of battery technology in laboratories, as well as ensuring the enhanced safety of next-generation LiBs in real-world fast-charging applications.

25 ENERGY STORAGE↗

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time reconstruction and control of pedestal-top electron density using RMP and gas puff at KSTAR

We report the experimental results of controlling the pedestal-top electron density by applying resonant magnetic perturbation (RMP) with in-vessel control coils and the main gas puff in the 2024-2025 KSTAR experimental campaign. The density is reconstructed using a parameterized $ψ_N$ grid and five channels of line-averaged density measured by the two-colored interferometer (TCI). The reconstruction procedure is accelerated by deploying a multi-layer perceptron to run in approximately 120 µ s and is sufficiently fast for real-time control. A proportional-integral controller was adopted, with the controller gains estimated from the system identification procedure. The experimental results demonstrate that the developed controller can follow a dynamic target while exclusively using both actuators. The absolute percentage errors between the electron density at $ψ_N$ = 0.89 and the target were approximately 1.5% median and a 2.5% average, respectively. The developed controller can even lower the density by using the pump-out mechanism under RMP, and it can follow a more dynamic range of density targets than a single actuator controller. The developed controller will enable experimental scenario exploration within a shot by dynamically setting the density target or maintaining a constant electron density within a discharge.

EFIT↗

Effect of pressure cycling and compression rate on the bcc-hcp transition in an FeNi alloy

Here, we investigate the body-centered cubic (bcc) to hexagonal close-packed (hcp) phase transition in Fe-10wt. %Ni alloy, combining pressure cycling and fast compression with time-resolved synchrotron x-ray diffraction in a dynamic diamond anvil cell. Three pressure cycles were conducted with compression rates ranging from 0.1 to nearly 10 3 GPa/s. During the first cycle with the slowest compression, the observed orientations in the bcc and hcp phases are consistent with the Burgers mechanism, followed by c-axis rotation of the hcp phase consistent with {$10$ $\bar{1}2$} twinning. During the following cycles with fast compression at 10 2 –10 3 GPa/s, the hcp phase exhibits negligible c-axis rotation with a nearly constant c/a ratio of ∼1.61 up to ∼30 GPa, indicating suppression of plastic deformation (especially, twinning) due to sample confinement from the gasket. Notably, the onset pressure of the transition decreases with additional pressure cycling and faster compression, which normally leads to over-pressurization. This suggests that defects or shear induced from the pressure cycling reduces the transition kinetics even during fast compression. These insights into the deformation and transition behavior in an FeNi alloy under multiple dynamic loading cycles can offer guidance for future design of advanced structural alloys and improve our understanding of planetary core processes.

FeNi alloy↗

Redox Couples Control Band Bending, Photovoltage, and Quasi-Fermi Levels in Tungsten Oxide (WO 3 ) Photoanodes

Tungsten oxide (WO 3 ) is a well-known photoanode and photocatalyst for photoelectrochemical (PEC) water oxidation. Because the compound has a deep valence band, it can facilitate the oxygen evolution reaction without added cocatalysts, and it can drive the oxidation of species with much higher electrochemical potentials, including the conversion of water to hydrogen peroxide, sulfate to persulfate, and iodate to meta-periodate. Here, we use the liquid vibrating Kelvin probe surface photovoltage (liquid VK-SPV) technique in combination with open circuit potential (OCP) and photoelectrochemical (PEC) scans to assess the possibility of reaching such oxidizing potentials in aqueous electrolytes and at open circuit. Here, this is done by mapping the quasi-Fermi levels of electrons and holes at the interfaces as a function of the light intensity. Nanostructured WO 3 photoelectrodes for this purpose were fabricated by thermal annealing of a tungstic acid solution on fluorine-doped tin oxide. Electrochemical measurements are conducted at open circuit and 400 nm LED light illumination in electrolytes containing fast (O 2 /H 2 O 2 ), slow (O 2 /H 2 O), and very oxidizing (NaIO 4 /NaIO 3 ) redox couples. Photovoltage values scale with the light intensity and with the built-in potential for each redox couple and reach values up to 0.61 V under 20 mW cm –2 illumination for the NaIO 4 electrolyte. This shows that the photoelectrodes behave like Schottky-type diodes whose maximum possible energy output is determined mainly by the built-in voltage of each junction. For slow redox couples, the quasi-Fermi level of the holes increases with light intensity due to hole accumulation at the WO 3 –liquid interface. For example, for the O 2 /H 2 O electrolyte, interfacial hole accumulation and removal occur on the 90–300 s time scale. For the fast hole acceptor H 2 O 2 , on the other hand, the quasi-Fermi level of the photoholes is pinned to the electrochemical potential of the O 2 /H 2 O 2 couple. This limits the energy conversion efficiency of the electrode. Overall, these results reveal the influence of charge transfer thermodynamics and kinetics on the photovoltage of WO 3 . Furthermore, the work further establishes VK-SPV as a contactless method to observe the photovoltage, carrier dynamics, and quasi-Fermi levels of semiconductor-liquid junctions.

Electrodes↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗