Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nimble Feedthrough Qualification - 125% High Explosive Overpressure Test Plan RevA

The primary purpose of this High Explosive (HE) Over-Pressure Test (OPT) is to qualify top cover diagnostic feedthroughs that will be used on LLNL Nimble Subcritical Experiment (SCE) Series designs per experimental design verification requirements specified in ASME Boiler and Pressure Vessel Code Case 2564, Impulsively-Loaded Pressure Vessels, Section VIII, Division 3; and to satisfy the over-test requirement of DOE-STD-1212. The diagnostic feedthroughs are part of the Vessel Confinement System (VCS), which is credited as a Safety Significant Design Feature per the U1a Facility Documented Safety Analysis (DSA). The OPT will be conducted at the LANL Area 1, R306 Firing Site (TA-15-R306) in a 3-foot diameter VCS depicted in Figure 1.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Battery Safety Factsheet

A brief overview of battery safety topics presented as a factsheet for a community audience. Battery safety topics include: battery management systems, thermal runaway, what to do in a battery fire emergency situation, battery storage considerations, commissioning, and battery codes and standards.

Battery Energy Storage↗

Long-term patterns of post-fire harvest diverge among ownerships in the Pacific West, U.S.A.

Abstract Post-fire harvest (PFH) is a forest management practice designed to salvage value from burned timber, mitigate safety hazards from dead trees, reduce long-term fuels, and prepare sites for replanting. Despite public controversy and extensive ecological research, little is known about how much PFH occurs on private and public lands in the U.S. Pacific West, or how practices changed with shifting forest policy and increasing area burned over the last three decades. We mapped PFH across 2.2M burned hectares in California, Oregon, and Washington between 1986-2017 and used time series intervention analysis to compare trends in area, rate (% of burned area harvested), and mean patch size between private (0.5M ha) and federal (1.6M ha) forest land and across a gradient of burn severity. Harvest rates varied by ownership (4.9% federal, 18.6% private, 8.0% overall), and practices evolved and diverged over the study period. PFH area and rate declined across all ownerships in the mid-1990s during a period of reduced fire activity. As area burned increased between the early 2000s and late 2010s, PFH area rebounded and surpassed late-1980s levels, while rates remained relatively low. On federal lands, PFH practices shifted in the early-to-mid 1990s towards lower rates (10.3% to 3.8%) and smaller patches (6.0 to 3.3 ha), following policy changes and increased litigation. PFH rates on federal lands decreased at all levels of burn severity, with the largest decreases (6.2% to 1.2%) in forests with low tree mortality (i.e. fire refugia). Conversely, private PFH rates and mean patch sizes more than doubled in forests burned at very low-to-moderate severity. Our results highlight how PFH practices have shifted with policy, socio-economic pressure, and increasing area burned over 31 years in the Pacific West. A similar area of post-fire harvest is now dispersed over larger fires, with practices diverging substantially between ownerships.

Zuspan, Aaron (ORCID:0000000315833710)↗

Elucidating the challenges in extracting ultra-slow flame speeds in a closed vessel - A CH 2 F 2 microgravity case study using optical and pressure-rise data

Refrigerants with a low global warming potential (GWP) possess mild flammability. Hence, a fundamental understanding of their combustion characteristics is required to assess their fire-hazardous potential. The laminar burning velocity is one fundamental property to describe these under safety evaluation aspects. However, measuring laminar burning velocities for slow-burning components, such as low-GWP alternatives, is challenging. This is due to influencing effects such as buoyant flame deformation, stretch, radiation, and confinement, especially at the flammability limits. Here, in the present study, we investigated near-limit flames of the representative refrigerant difluoromethane (CH 2 F 2 ) with nitrogen-enriched oxidizer mixtures to elucidate the potentials and limitations at ultra-slow flame speeds of two widely used flame speed measurement methods in the closed vessel configuration: the optical flame speed measurement in the early quasi-isobaric regime and the flame speed determination from the pressure-rise during the later phase of the isochoric combustion process. Experiments were performed under terrestrial- and microgravity, conducted in a specially designed setup suitable for drop tower applications, using both methods in parallel. Recommendations for the extraction of flame speed data are derived from the non-buoyant reference investigations under microgravity and transferred to ultra-slow flames at terrestrial gravity. Near-limit flames under microgravity were found to be significantly affected by stretch effects for the optical method so that flame speed extrapolations to unstretched conditions are prone to errors. Stretch also affects the pressure method’s lower evaluation limit, and errors can be estimated by combining flame speed data from the pressure method and Markstein lengths from optical experiments.

42 ENGINEERING↗

National Fire Protection Association Spurs the Safe Adoption of EVs Through Education and Outreach

As electric vehicles (EV) and their charging infrastructure steadily increase in popularity across the U.S., growing pains still exist, impeding their true potential for growth. The barriers include a general lack of knowledge around EV systems, range anxiety, electrical workplace safety practices, code compliance and inspection for charging stations, maintenance garages and workers, insurance concerns, and the potential risks associated with damaged lithium-ion batteries (fires, re-ignition, water immersion, and stranded energy).NFPA partnered with SMEs, training development organizations, and Clean City Coalitions to create a series of common online trainings for each EV ecosystem sector, educating communities on the realities of EV proliferation, myths, facts, statistics, codes, and basic information for each sector to become versed in EV knowledge. We also constructed a workshop program for the many EV stakeholders who should be involved in setting up a strategic, cohesive outlook for the participating towns and cities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries

Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.

25 ENERGY STORAGE↗

Los Alamos National Laboratory Floodplain Assessment for the West Road Post and Cable Fencing Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take action at Los Alamos National Laboratory (LANL) to install post and cable or in-kind barriers along West Road at selected locations near the Los Alamos County ice-skating rink in Los Alamos Canyon (Figure 1). The proposed project is intended to improve vehicular and pedestrian safety on West Road by reducing traffic hazards associated with unsafe roadside parking and reduce wildland fire hazards associated with vehicles driving and parking on vegetation. West Road crosses approximately 0.35 miles (mi.) (1,900 feet (ft.)) of the Los Alamos Canyon floodplain at the bottom of Los Alamos Canyon. Project activities within the floodplain include blocking access to the informal roadside parking along either side of West Road in Los Alamos Canyon.

42 ENGINEERING↗

Case study of UAS ignition of prescribed fire in a mixedwood on the William B. Bankhead National Forest, Alabama

Abstract Background For at least four decades, practitioners have recognized advantages of aerial versus ground ignition for maximizing the effectiveness of prescribed fires. For example, larger areas can be ignited in less time, or ignition energy may be variously targeted over an area in accordance with the uneven distribution of fuels. The maturation of wireless communication, geopositioning systems, and unmanned aerial systems (UAS) has enhanced those advantages, and UAS approaches also provide further advantages relative to helicopter ignitions, such as reduced risk to human safety, lower operating costs, and higher operational flexibility. In a long running study at the Bankhead National Forest in northcentral Alabama, prescribed fire has been used for nearly 20 years. Most of the burns have been hand-ignited via drip torches, while some have been aerially ignited via helicopter. In March 2022, for the first time, a UAS was used to ignite prescribed fires across a landscape that included a long-term research stand. This field note relates comparisons of both fire behavior and fuel consumption metrics for the UAS-ignited burn versus previous burns on the same stand, and versus burns of other research stands in the same year. Results The UAS-ignited prescribed fire experienced burn effects similar to those from ground-ignited prescribed fires on the same stand in previous years, as well as those from ground-ignited prescribed fires on other stands in the same year. Conclusion This post hoc analysis suggests that UAS ignition approaches may be sufficient for achieving prescribed burn goals, thereby enabling practitioners to realize the advantages offered by that ignition mode.

Environmental Sciences & Ecology↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Ion-Conducting, Scalable, and Mechanically Reinforced Ceramic Film for High Voltage Solid-State Batteries

Concerning the safety aspects of Li+ ion batteries, an epoxy-reinforced thin ceramic film (ERTCF) is prepared by firing and sintering a slurry-casted composite powder film. The ERTCF is composed of Li + ion conduction channels and is made of high amounts of sintered ceramic Li 1+ x Ti 2-x Al x (PO 4 ) 3 (LATP) and epoxy polymer with enhanced mechanical properties for solid-state batteries. The two- and three-dimensional characterizations are conducted not only for showing continuous Li+ ion channels thorough LATP ceramic channels with over 10-4 S cm-1 of ionic conductivity but also to investigate small amounts of epoxy polymer with enhanced mechanical properties. Solid-state Li + ion cells are fabricated using the ERTCF and they show initial charge–discharge capacities of 139/133 mAh g -1 . Furthermore, the scope of the ERTCF is expanded to high-voltage (>8 V) solid-state Li + ion batteries through a bipolar stacked cell design. Hence, it is expected that the present investigation will significantly contribute in the preparation of the next generation reinforced thin ceramic film electrolytes for high-voltage solid-state batteries.

25 ENERGY STORAGE↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 72 Outdoor Live Fire Range Gate Installation Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed upgrades are intended to improve range safety.

54 ENVIRONMENTAL SCIENCES↗

Large Local Currents in a Lithium-Ion Battery during Rest after Fast Charging

Increasing electric vehicle (EV) adoption requires lithium-ion batteries that can be charged quickly and safely. Some EV batteries have caught on fire despite being neither charged nor discharged. While the lithium that plates on graphite during fast charging affects battery safety, so do the internal ionic currents that can occur when the battery is at rest after charging. These currents are difficult to quantify; the external current that can readily be measured is zero. Here we study a graphite electrode at rest after 6C fast charging using operando X-ray microtomography. We quantify spatially resolved current density distributions that originate at plated lithium and end in underlithiated graphite particles. The average current densities decrease from 1.5 to 0.5 mA cm -2 in about 20 min after charging is stopped. Surprisingly, the range of the stripping current density is independent of time, with outliers above 20 mA cm -2 . In conclusion, the persistence of outliers provides a clue as to the origin of catastrophic failure in batteries at rest.

25 ENERGY STORAGE↗

Recent advances in combustion science related to hydrogen safety

Hydrogen is a key pillar in the global Net Zero strategy. Rapid scaling up of hydrogen production, transport, distribution and utilization is expected. This entails that hydrogen, which is traditionally an industrial gas, will come into proximity of populated urban areas and in some situations handled by the untrained public. To realize all their benefits, hydrogen and its technologies must be safely developed and deployed. The specific properties of hydrogen involving wide flammability range, low ignition energy and fast flame speed implies that any accidental release of hydrogen can be easily ignited. Comparing with conventional fuels, combustion systems fueled by hydrogen are also more prone to flame instability and abnormal combustion. This paper aims to provide a comprehensive review about combustion research related to hydrogen safety. It starts with a brief introduction which includes some overview about risk analysis, codes and standards. The core content covers ignition, fire, explosions and deflagration to detonation transition (DDT). Considering that DDT leads to detonation, and that detonation may also be induced directly under special circumstances, the subject of detonation is also included for completeness. The review covers laboratory, medium and large-scale experiments, as well as theoretical analysis and numerical simulation results. While highlights are provided at the end of each section, the paper closes with some concluding remarks highlighting the achievements and key knowledge gaps.

08 HYDROGEN↗

Effects of radiation heat loss on planar and spherical hydrofluorocarbon/air flames

Hydrofluorocarbons (HFC), which are mildly flammable and pose potential fire risks, have received greater attention as a viable low global warming potential alternative to traditional refrigerant and fire-suppressant compounds. Therefore, there is a demand to accurately quantify their flammability and re-activity to establish proper safety metrics. Here, this study investigates the effects of radiation heat loss on slowly-propagating HFC/air laminar flames. Planar 1-D simulations of R-32/air and R-1234yf/air flames show significant reductions in laminar flame speed due to radiative heat losses from the flame zone. Simulations of spherically expanding flames (SEF) revealed that the radiation-induced flow needs to be considered when interpreting data from experiments. To this end, a Spherical-flame RADiation-Induced Flow (SRADIF) model was developed to estimate the burned gas inward flow velocities in constant-pressure SEFs, utilizing the optically thin limit assumption to model radiation heat loss. The model was validated against results from detailed numerical simulations of SEFs, from which radiation-induced inward flow was derived using a new formulation considering both the radiation heat loss and convective flow effects. Results show that SRADIF accurately predicts the inward flow velocity for R-32/air mixtures over a range of conditions and performs significantly better compared to existing analytical models. However, the model was unable to accurately predict flow velocities for R-1234yf/air flames and the reason for this is discussed. (224 words)

42 ENGINEERING↗

Criticality Safety Calculations for Inadvertent PuF6 Formation

During a review of the Surplus Plutonium Disposition (SPD) at Savannah River Site (SRS) project Safety Basis Strategy a comment was made about the risk of inadvertent formation of plutonium hexafluoride, PuF6, during a plutonium fire suppressed by the NovecTM 1230 fire suppressant. NovecTM 1230 is a fluorine rich non-hydrogenous extinguishing agent. Hydrogenous materials, like water, increase reactivity of fissile material by adding moderation to the system and thus are generally not used as firefighting agents in fissile material areas.

Wade, Brindley↗

White Paper on Case Study of Safe Installation of Second-Life Energy Storage System

This technical report provides for a case study for the safe installation of a second-life, or repurposed, battery, that has been reconfigured for use as a stationary energy storage systems (ESS). Driven by legislative requirements such as California Senate Bill 615 and projections that retired EV batteries could meet a substantial portion of U.S. grid ESS needs beginning in 2035, the repurposing of EV batteries is anticipated to grow significantly. However, safety concerns arise from the effects of aging, unknown prior usage history, and changes in thermal runaway behavior, which may increase failure risks compared to new batteries. NFPA 855, the predominant U.S. standard for ESS installation, mandates that second-life batteries meet all requirements for new batteries, with repurposers complying with UL 1974 in addition to obtaining UL 9540 and UL 1973 listings. These are certifications that few repurposers have achieved and represent a regulatory barrier to entry for the market as a whole.

47 OTHER INSTRUMENTATION↗

A Green, Fire–Retarding Ether Solvent for Sustainable High–Voltage Li–Ion Batteries at Standard Salt Concentration

Lithium-ion batteries (LIBs) are increasingly encouraged to enhance their environmental friendliness and safety while maintaining optimal energy density and cost-effectiveness. Although various electrolytes using greener and safer glyme solvents have been reported, the low charge voltage (usually lower than 4.0 V vs Li/Li + ) restricts the energy density of LIBs. Herein, tetraglyme, a less-toxic, non-volatile, and non-flammable ether solvent, is exploited to build safer and greener LIBs. It is demonstrated that ether electrolytes, at a standard salt concentration (1 m), can be reversibly cycled to 4.5 V vs Li/Li + . Anchored with Boron-rich cathode-electrolyte interphase (CEI) and mitigated current collector corrosion, the LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode delivers competitive cyclability versus commercial carbonate electrolytes when charged to 4.5 V. Synchrotron spectroscopic and imaging analyses show that the tetraglyme electrolyte can sufficiently suppress the overcharge behavior associated with the high-voltage electrolyte decomposition, which is advantageous over previously reported glyme electrolytes. The new electrolyte also enables minimal transition metal dissolution and deposition. NMC811||hard carbon full cell delivers excellent cycling stability at C/3 with a high average Coulombic efficiency of 99.77%. In conclusion, this work reports an oxidation-resilient tetraglyme electrolyte with record-high 4.5 V stability and enlightens further applications of glyme solvents for sustainable LIBs by designing Boron-rich interphases.

36 MATERIALS SCIENCE↗