Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Super Strypi HWIL 6DOF (Hardware-In-Loop six-degree-of-freedom) Rev. 2175

The Super Strypi HWIL is a six degree-of-freedom (6DOF) simulation for the Super Strypi Launch Vehicle. The simulation is used to test the NGC flight software including the navigation software. Aerodynamic and propulsive forces, mass properties, ACS (attitude control system) parameters are defined in input files. Output parameters are saved to a Matlab mat file.

Gilkey, Jeff C.↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis, testing, and operation of the MAGI thermal control system

The Aerospace Corporation has completed the development of the Mineral and Gas Identifier (MAGI) sensor - an airborne multi-spectral infrared instrument that is designed to discriminate surface composition and to detect gas emissions from the environment. Sensor performance was demonstrated in a series of flights aboard a Twin Otter aircraft in December 2011 as a stepping stone to a future satellite sensor design. To meet sensor performance requirements the thermal control system was designed to operate the HgCdTe focal plane array (FPA) at 50 K with a 1.79 W heat rejection load to a 44.7 K sink and the optical assembly at 100 K with a 7.5 W heat load to a 82.3 K sink. Two commercial off-theshelf (COTS) Sunpower Stirling cryocoolers were used to meet the instrument’s cooling requirements. A thermal model constructed in Thermal Desktop was used to run parametric studies that guided the mechanical design and sized the two cryocoolers. This paper discusses the development, validation, and operation of the MAGI thermal control system. Detailed energy balances and temperature predictions are presented for various test cases to demonstrate the utility and accuracy of the thermal model. Model inputs included measured values of heat lift as a function of input power and cold tip temperature for the two cryocoolers. These measurements were also used to make predictions of the cool-down behavior from ambient conditions. Advanced heater software was developed to meet unique requirements for both sensor cool-down rate and stability at the set point temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purpose-Built UAVs for Physical Sampling of Trace Contamination at the Portsmouth Gaseous Diffusion Plant - 17331

The sampling of trace amounts of contamination, particularly of low-energy byproducts such as americium, presents a challenge for non-contact sensing. In many cases, such as determining the need for cleaning inside the exhaust shaft of the Waste Isolation Pilot Plant or sampling the walls of the enormous Gaseous Diffusion Plant at Portsmouth, it may be desirable to take physical swab samples at carefully distributed sample locations for analysis by mass spectrometry. Because of the danger posed to human workers in such scenarios, including risk of falls from lethal heights and exposure to low levels of radiation and the hassle of donning and doffing PPE, a low-cost robotic solution is desired. The inaccessibility of the heights involved suggest Unmanned Aerial Vehicle (UAV) solutions, rather than Unmanned Ground Vehicle (UGV) solutions, but conventional quadrotor UAVs are ill-suited to precise physical interaction with their surroundings. Quadrotors are under-actuated, rendering them non-holonomic and preventing the dexterous application of arbitrary generalized force/torques in interaction with the environment. At Purdue University, the authors have developed a number of novel UAV platforms suitable for dexterous interaction with the environment, making them ideal for such applications. These platforms can independently control forces in all directions, allowing for controlled application of the swab to the surface. Because of the scale of these structures (over 2 km in the case of the Gaseous Diffusion Plant), flight efficiency is of supreme importance. The Purdue team is took a variety of vehicles to the Gaseous Diffusion Plant for field trials on site in August, 2016. (With results available prior to the meeting.) The Purdue Dexterous Hexrotor is a fully-actuated Hexrotor capable of exerting forces in all six directions of force and torque. Operating alone or in swarms, the Dexterous Hexrotor can fly in free space, transition to contact through impact control, and sample the surface through force control. The Purdue I-BoomCopter is a tri-copter with an extra horizontal propeller that enables long-distance flight without pitching and the ability to apply closed-loop forces horizontally. Finally, the Purdue Tiltrotor VTOL is an under-actuated hybrid UAV that combines tilting rotors for vertical takeoff and landing, with a fixed-wing, flying-body design that is ultra-efficient for long-distance flight. The Dexterous Hexrotor provided two demonstrations of physical sampling of walls and crane rails. In sampling the large open sections of the inside of the plant, a small swarm of three UAVs is commanded to sample three distinct points on an internal map of the building. Human-supervised autonomy permits the UAVs to take off by themselves, find a clear elevation at which to fly through uncluttered space, navigate to their designated sampling points, and pause for confirmation by the human supervisor. The supervisor is presented with a video image of the intended sampling spot, which, if confirmed, the UAV will automatically approach and sample. The UAVs then autonomously return to the take-off spot. The second demo involved a single UAV searching upwards, then transitioning into 3-D SLAM mode to wait for a safe sampling spot on the 3-D scan to acquire the sample from the crane rail. The human supervisor, in this case, is responsible for ensuring the absence of cables and other obstacles. I-BoomCopter demonstrated its high-speed, long-distance coverage ability by making a few fast passes before homing in on a mock-up electrical panel with door, which it opened and closed. The dexterity of the I-BoomCopter results from its large propellers, which allow for controlled hovering and the horizontal thruster for applying forces of significant magnitude. Finally, the Tiltrotor VTOL is highly efficient in fixed-wing mode, but the tilt-rotor is under-actuated in hover. The tilt-rotor will take off vertically, then transition to high-speed, long-distance flight to make a number of passes inside the facility. The significance of these demos is the low-cost implementation of physical sampling over prescribable locations in difficult-to-reach areas of potentially contaminate facilities. To make this tractable over very large facilities, the demonstration of combinations of dexterous hovering ability and long-distance/high-speed flight is also in evidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of stochastic particle dispersion modeling in turbulent round jets

ODT (one-dimensional turbulence) simulations of particle-carrier gas interactions are performed in the jet flow configuration. Particles with different diameters are injected onto the centerline of a turbulent air jet. The particles are passive and do not impact the fluid phase. Their radial dispersion and axial velocities are obtained as functions of axial position. The time and length scales of the jet are varied through control of the jet exit velocity and nozzle diameter. Dispersion data at long times of flight for the nozzle diameter (7 mm), particle diameters (60 and 90 µm), and Reynolds numbers (10, 000–30, 000) are analyzed to obtain the Lagrangian particle dispersivity. Flow statistics of the ODT particle model are compared to experimental measurements. It is shown that the particle tracking method is capable of yielding Lagrangian prediction of the dispersive transport of particles in a round jet. In this study, three particle-eddy interaction models (Type-I, -C, and -IC) are presented to examine the details of particle dispersion and particle-eddy interaction in jet flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ToF-SIMS depth profiling of altered glass

Glass and mineral corrosion usually leads to the formation of morphologically and compositionally complex surface layers that can be characterized by various analytical techniques to infer rate control mechanisms. In this study, we investigate the capabilities and limitations of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to better understand chemical processes of glass corrosion. In particular, we focus on the potential impact of the ToF-SIMS ion beam on the distribution of several elements of interest in alteration layers formed on International Simple Glass, a six-oxide reference glass altered in a solution enriched in alkalis and spiked with H 2 18 O. A thin flake of glass partially altered on both sides is analyzed entirely from one side to the other to determine whether atoms weakly bonded to the solid are displaced by the beams. We highlight the beam effect on cations weakly bonded to the silicate network (Li, Na, K, and B, Ca, Cs to a lesser extent) affecting the profile shape of these elements. No impact is observed on 18 O and H, but it is demonstrated that quantification of isotopic ratios is possible only for a limited range of isotopic enrichment.

36 MATERIALS SCIENCE↗

Asymptotic scaling laws for the stagnation conditions of Z-pinch implosions

Implosions of magnetically driven annular shells (Z pinches) are studied in the laboratory to produce high-energy-density plasmas. Such plasmas have a wide-range of applications including x-ray generation, controlled thermonuclear fusion, and astrophysics studies. In this work, we theoretically investigate the in-flight dynamics of a magnetically driven, imploding cylindrical shell that stagnates onto itself upon collision on axis. The converging flow of the Z-pinch is analyzed by considering the implosion trajectory in the (A, M) parametric plane, where A is the in-flight aspect ratio and M is the implosion Mach number. For an ideal implosion in the absence of instabilities and in the limit of A ≫ 1, we derive asymptotic scaling laws for hydrodynamic quantities evaluated at stagnation (e.g., density, temperature, and pressure) and for performance metrics (e.g., soft x-ray emission, K-shell x-ray emission, and neutron yield) as functions of target-design parameters.

Ruiz, D. E. [Sandia National Laboratories (SNL-NM)↗

Detecting Surface Changes from an Underground Explosion in Granite Using Unmanned Aerial System Photogrammetry

Efficient detection and high-fidelity quantification of surface changes resulting from underground activities are important national and global security efforts. In this investigation, a team performed field-based topographic characterization by gathering high-quality photographs at very low altitudes from an unmanned aerial system (UAS)-borne camera platform. The data collection occurred shortly before and after a controlled underground chemical explosion as part of the United States Department of Energy’s Source Physics Experiments (SPE-5) series. The high-resolution overlapping photographs were used to create 3D photogrammetric models of the site, which then served to map changes in the landscape down to 1-cm-scale. Separate models were created for two areas, herein referred to as the test table grid region and the nearfield grid region. The test table grid includes the region within ~40 m from surface ground zero, with photographs collected at a flight altitude of 8.5 m above ground level (AGL). The near-field grid area covered a broader area, 90–130 m from surface ground zero, and collected at a flight altitude of 22 m AGL. The photographs, processed using Agisoft Photoscan® in conjunction with 125 surveyed ground control point targets, yielded a 6-mm pixel-size digital elevation model (DEM) for the test table grid region. This provided the ≤3 cm resolution in the topographic data to map in fine detail a suite of features related to the underground explosion: uplift, subsidence, surface fractures, and morphological change detection. The near-field grid region data collection resulted in a 2-cm pixel-size DEM, enabling mapping of a broader range of features related to the explosion, including: uplift and subsidence, rock fall, and slope sloughing. This study represents one of the first works to constrain, both temporally and spatially, explosion-related surface damage using a UAS photogrammetric platform; these data will help to advance the science of underground explosion detection.

54 ENVIRONMENTAL SCIENCES↗

A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS

Orthogonal injection time-of-flight (orthoTOF) mass spectrometry (MS) is the most prevalent form of TOFMS, owing to its greater control over incoming ion energy, the ability to correct for aberrations in incoming ion velocity and position, and its ability to provide an entire mass spectrum within a single scan. However, the duty cycle of orthoTOFMS is low compared with scanning analyzers, which can have 100% duty cycle when measuring a single type of ion. Typical duty cycles for orthoTOFMS range from 1% to 30%, depending on instrument geometry. Generally, as instrument resolution increases, duty cycle decreases. Additionally, the greatest duty cycle is achieved for the highest m/z ion recorded in the spectrum, and decreases for all other ions as a function of m/z. In a prior publication [Loboda, A.V.; Chernushevich, I.V. J. Am. Soc. Mass Spectrom. 20, 1342–1348 (20)], a novel trapping/release method for restoring the duty cycle of a V-geometry orthoTOFMS to near 100% (referred to as “Zeno pulsing”) was presented. Here, we apply that method to a W-TOF geometry analyzer with analog detection. Across a m/z range of 100–2000, sensitivity gains of ~5–20 are observed, for total ion currents approaching ~10{sup 7} ions·s{sup −1}. Zeno pulsing, or similar strategies for restoring duty cycle, will continue to be important as instrument resolution in orthoTOFMS is increased through the use of ion mirrors. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of a spherical plasma liner for plasma-jet-driven magneto-inertial fusion

Plasma-jet-driven magneto-inertial fusion is an alternative approach to controlled nuclear fusion, which aims to utilize a line-replaceable dense plasma liner as a repetitive spherical compression driver. In this experiment, first measurements of the formation of a spherical argon plasma liner formed from 36 discrete pulsed plasma jets are obtained on the Plasma Liner Experiment. Properties including liner uniformity and morphology, plasma density, temperature, and ram pressure are assessed as a function of time throughout the implosion process and indicate an apparent transition from initial kinetic inter-jet interpenetration to collisional regime near stagnation times, in accordance with theoretical expectation. A lack of primary shock structures between adjacent jets during flight implies that arbitrarily smooth liners may be formed by way of corresponding improvements in jet parameters and control. The measurements facilitate the benchmarking of computational models and understanding the scaling of plasma liners toward fusion-relevant energy density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices

Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision pulse shape simulation for proton detection at the Nab experiment

The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron β decay to an anticipated precision of approximately 0.1%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. In conclusion, we present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight Extreme Environment Diffractometer at the Helmholtz-Zentrum Berlin

The Extreme Environment Diffractometer (EXED) is a new neutron time-of-flight instrument at the BER II research reactor at the Helmholtz-Zentrum Berlin, Germany. Although EXED is a special-purpose instrument, its early construction made it available for users as a general-purpose diffractometer. In this respect, EXED became one of the rare examples, where the performance of a time-of-flight diffractometer at a continuous source can be characterized. In this paper, we report on the design and performance of EXED with an emphasis on the unique instrument capabilities. The latter comprise variable wavelength resolution and wavelength band, control of the incoming beam divergence, the possibility to change the angular positions of detectors and their distance to the sample, and use of event recording and offline histogramming. These features combined make EXED easily tunable to the requirements of a particular problem, from conventional diffraction to small angle neutron scattering. The instrument performance is demonstrated by several reference measurements and user experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Programmable Chemical Gradient Patterns by Soft Grayscale Lithography

A method for fabricating chemical gradients on planar and nonplanar substrates using grayscale lithography is reported. Compliant grayscale amplitude masks are fabricated using a vacuum-assisted microfluidic filling protocol that employs dilutions of a carbon-black-containing polydimethylsiloxane emulsion (bPDMS) within traditional clear PDMS (cPDMS) to create planar, fully self-supporting mask elements. The mask is then placed over a surface functionalized with a hydrophobic coumarin-based photocleavable monolayer, which exposes a polar group upon irradiation. The mask serves to modulate the intensity of incident UV light, thereby controlling the density of molecules cleaved. The resulting molecular-level grayscale patterns are characterized by condensation microscopy and imaging mode time-of-flight secondary-ion mass spectrometry (ToF-SIMS). Due to the inherent flexibility of this technique, the photofuse as well as the gradient patterns can be designed for a wide range of applications; in this paper two proof-of-concept demonstrations are shown. The first utilizes the ability to control the resulting contact angle of the surface for the fabrication of a passive pressure-sensitive microfluidic gating system. The second is a model surface modification process that utilizes the functional groups deprotected during the photocleavage to pattern the deposition of moieties with complementary chemistry. The spatial layout, resolution, and concentration of these covalently linked molecules follow the gradient pattern created by the grayscale mask during exposure. Furthermore, the programmable chemical gradient fabrication scheme presented in this work allows explicit engineering of both surface properties that dictate nonspecific interactions (surface energy, charge, etc.) and functional chemistry necessary for covalent bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold ion UV photofragmentation spectroscopy and dynamics (Invited)

Up to ten years ago, very little was known about the excited states of protonated amino acids isolated in the gas phase. From the experimental point of view, the study was hampered by the lack of ease of production of such species in sufficient density to apply photon-based techniques. With the development and widespread use of electrospray ionization sources coupled with modified or homebuilt mass spectrometers, there has been significant research into the spectroscopy of biomimetic and biologically relevant molecules. Besides, these species are floppy such that an efficient cooling is required to record clear spectroscopy. Warm protonated species display congested spectra. To extract precise spectroscopic information and avoid spectral congestion, the species need to be cooled down to less than 50 K. We present our latest results on the electronic spectroscopy of protonated phenylalanine and tyrosine on a large spectral domain (225-290 nm). These species are studied in a new simplified apparatus combining an electrospray ionization source, a cryogenically cooled quadrupole ion trap (∼10 K) and time-of-flight mass spectrometry. The role of proton transfer from the NH{sub 3}{sup +} moiety to the p-ring or to CO of the carboxylic acid group is evidenced by UV photofragment spectroscopy. This first step controls the fragmentation pathways, which strongly depend on the nature of the electronic excited states, i.e. ππ*, ππ*{sub CO} and πσ{sub NH3}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Triage of oxidation-prone proteins by Sqstm1/p62 within the mitochondria

Highlights: {yields} The mitochondrion contains its own protein quality control system. {yields} p62 localizes within the mitochondria and forms mega-dalton sized complexes. {yields} p62 interacts with oxidation-prone proteins and the proteins of quality control. {yields} In vitro delivery of p62 improves mitochondrial functions. {yields} p62 is implicated as a participant in mitochondrial protein quality control. -- Abstract: As the mitochondrion is vulnerable to oxidative stress, cells have evolved several strategies to maintain mitochondrial integrity, including mitochondrial protein quality control mechanisms and autophagic removal of damaged mitochondria. Involvement of an autophagy adaptor, Sqstm1/p62, in the latter process has been recently described. In the present study, we provide evidence that a portion of p62 directly localizes within the mitochondria and supports stable electron transport by forming heterogeneous protein complexes. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF) of mitochondrial proteins co-purified with p62 revealed that p62 interacts with several oxidation-prone proteins, including a few components of the electron transport chain complexes, as well as multiple chaperone molecules and redox regulatory enzymes. Accordingly, p62-deficient mitochondria exhibited compromised electron transport, and the compromised function was partially restored by in vitro delivery of p62. These results suggest that p62 plays an additional role in maintaining mitochondrial integrity at the vicinity of target machineries through its function in relation to protein quality control.

60 APPLIED LIFE SCIENCES↗

Development of soft x-ray time-resolved photoemission spectroscopy system with a two-dimensional angle-resolved time-of-flight analyzer at SPring-8 BL07LSU

We have developed a soft x-ray time-resolved photoemission spectroscopy system using synchrotron radiation (SR) at SPring-8 BL07LSU and an ultrashort pulse laser system. Two-dimensional angle-resolved measurements were performed with a time-of-flight-type analyzer. The photoemission spectroscopy system is synchronized to light pulses of SR and laser using a time control unit. The performance of the instrument is demonstrated by mapping the band structure of a Si(111) crystal over the surface Brillouin zones and observing relaxation of the surface photo-voltage effect using the pump (laser) and probe (SR) method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗