Depth profile of radiolytic fluence on Europa: implications for remote sensing and in-situ analyses
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The development of new technologies and the miniaturization of sensors bring new requirements for our ability to predict and forecast hazardous space weather conditions.
Micrometre and smaller scale dust within cometary comae can be observed by telescopic remote sensing spectroscopy [1] and the particle size and abundance can be measured by in situ spacecraft impact detectors [2]. Initial interpretation of the samples returned from comet 81P/Wild 2 by the Stardust spacecraft [3] appears to show that very fine dust contributes not only a small fraction of the solid mass, but is also relatively sparse [4], with a low negative power function describing grain size distribution, contrasting with an apparent abundance indicated by the on-board Dust Flux Monitor Instrument (DFMI) [5] operational during the encounter. For particles above 10 m diameter there is good correspondence between results from the DFMI and the particle size inferred from experimental calibration [6] of measured aerogel track and aluminium foil crater dimensions (as seen in Figure 4 of [4]). However, divergence between data-sets becomes apparent at smaller sizes, especially submicrometre, where the returned sample data are based upon location and measurement of tiny craters found by electron microscopy of Al foils. Here effects of detection efficiency tail-off at each search magnification can be seen in the down-scale flattening of each scale component, but are reliably compensated by sensible extrapolation between segments. There is also no evidence of malfunction in the operation of DFMI during passage through the coma (S. Green, personal comm.), so can the two data sets be reconciled?
No abstract available
No abstract available
No abstract provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence.
Introduction: Space weathering processesalter the microstructural, compositional, and optical properties of airless planetary surfaces.Solar wind space weatheringforms ion-damaged rims within the outermost ~100 nm of regolith grains through atomic-displacements and implantation of energetic H+and He+ions[1]. Transmission electron microscope(TEM)studies of space weathered Itokawa and lunar olivine particles reveal predominantly nanocrystalline solar wind-damaged rims with only minor regions of amorphization[2-5]. This finding differs from laboratoryion irradiation experiments in which samples become amorphous at fluences 2-3 orders of magnitude lower than the independentlyconstrained fluences for still-crystalline natural samples [6-7].Ion flux is generally considered to have a secondaryeffectcompared to fluence in these irradiation experiments. However, solar wind irradiation of natural samples occurs at a flux that is ~4-5 orders of magnitude lower than whatisused inlaboratory simulations (e.g., [6,8-9]). Constraining how the very low ion flux of solar wind influences the microstructural, chemical, and spectral alteration of silicate minerals will improve our understanding of solar wind space weathering and aid in the analysis of returned samples from the Hayabusa2 and OSIRIS-REx missions. Here we report results from low-and high-flux ion irradiation experiments on the Murchison (CM2)meteoritewithcomparable total fluences. Methods: We performed low-flux and high-flux He+(4 keV) and H+(1 keV) irradiation experiments on separate, dry-cut Murchison slabs. Low-flux He+irradiation reached a total fluence of 2.1 x 1016ions/cm2(~400 years of exposure at Bennu) using a flux of 3.6 x 1011ions/cm2/s; low-flux H+irradiation reached a total fluence of 3.9 x 1016ions/cm2(~30 years) using a flux of 6.6 x 1011ions/cm2/s. High-flux He+irradiation reached a total fluence of 2.0 x 1016ions/cm2(~400 years)using a flux of 9.1 x 1012ions/cm2/s; high-flux H+irradiation reached a total fluence of 5.8 x 1016ions/cm2(~50 years)using flux of 8.4 x 1012ions/cm2/s. By irradiating to similar total fluences in both the low-flux and high-flux experiments, we can better isolate and evaluatethe effects of ion flux. Differences between unirradiatedand irradiated surfaces are determined using threeanalytical techniques:(1) in situX-ray photoelectron spectroscopy(XPS) reveals changes in surface chemistry,(2) visible to near-infrared spectroscopy (VNIR; 0.35-2.5 μm) highlights changes in spectraltrends, such as albedo and slope, and (3) TEM and energy-dispersive X-ray spectroscopy (EDS) identifieschanges in nanoscale structure and elemental composition within olivine and matrix electron-transparent thin sections prepared using focused ion beam scanning electron microscopy (FIB-SEM). Results and Discussion: XPS analyses of the low-fluxand high-fluxHe+-and H+-irradiated samples showa minorreduction in surface carbon contentand chemicalreduction ofFe3+to Fe2+. The latter result is consistent with the higher Fe2+/Fe3+ratios observed in phyllosilicate-rich space weathered rims of Ryugu grains [10].VNIR analyses suggest that the low-flux H+-irradiated spectrum has a slightly bluer slope (over 0.65-2.5 μm) compared to the unirradiated VNIR spectrum from [9] while the low-flux He+-irradiated spectral slope is comparable to the unirradiated surface. Both the high-flux He+-and H+-irradiated VNIR spectra exhibitslightlyhigheralbedos at shorter wavelengths relativeto their unirradiated counterparts, with He+irradiation yielding a greater change. Thus far, the low-flux He+-irradiated matrix and olivine FIBsections as well as the low-flux H+-irradiated olivine FIBsection have been examined with TEM. The surfaces of all three samplesshowless vesiculation than high-flux/high-fluenceirradiated matrix and olivine samples from [9]. The depth of phyllosilicate amorphization in thelow-fluxHe+-irradiated matrix FIBsection varieslaterally, with crystalline domains occurring as shallow as ~25 nm in some regions. Thelow-flux He+-irradiated olivine FIBsection has acontinuous,~40-90 nm thick ion-affected layer with polycrystalline and amorphous microstructures. The low-flux H+-irradiated olivine sampleexhibits a distinct, ~10-40 nm ion-affected layer whose uppermost ~20 nmin thicker regions is predominantly amorphous.Continuing to compare results from this work to those from [9] will provide a comprehensive understanding of how ion flux impacts the microstructural, chemical, and optical modification of various mineral phases and, in turn,help identify space weathering features from parent body alteration in Hayabusa2 and OSIRIS-REx returned samples.
The effect of bombardment of 8 km per second atomic oxygen (AO) experienced by exposed surfaces of satellites in low Earth orbit must be considered in the selection of materials to be used in instruments and functional systems on these satellites. The degree of importance of the effects varies widely depending on the material, the application, and the exposure (fluence of atoms) to which it is to be subjected. Some highly erodible thin polymer film materials might be considered unacceptable on a long-lived space station, but may be perfectly serviceable on a normal shuttle flight. In order to determine the acceptability of a material for a particular environment, a designer must know the relationship between the magnitude of the effect (for example, mass-loss) and the magnitude of the fluence. To determine this relationship, we need data over a useful range of fluence. Until the return of the Long Duration Exposure Facility (LDEF), the bulk of the data on materials effects was obtained from a few shuttle flights, and the bulk of that data from the flight of experiment Evaluation of Oxygen Interaction with Materials (EOIM-2) on STS-8 in 1983. EOIM-2 obtained a fluence of 3.5 x 10(exp 20) atoms cm(exp -2), while the LDEF fluence approached 10(exp 22) atoms cm(exp -2), or about 30 times greater. Although other flight exposures had been obtained with lower fluences, considerable uncertainty was attached to these results because of the possibility of large relative systematic errors and of other factors such as sweeping angle of attack. In the future, it is hoped that simulation facilities in the laboratory will allow testing of materials without the necessity of flying them in space. In addition, if the relationship of effect with oxygen fluence is well determined, it should not be necessary to expose a material for an entire mission fluence. In this paper, we shall avoid a comparison of flight data with results from simulators, though that comparison is important for the materials community. The present discussion is limited to flight data only.
Phototropism is induced by blue light, which also induces desensitization, a partial or total loss of phototropic responsiveness. The fluence and fluence-rate dependence of desensitization and recovery from desensitization have been measured for etiolated and red light (669-nm) preirradiated Arabidopsis thaliana seedlings. The extent of desensitization increased as the fluence of the desensitizing 450-nm light was increased from 0.3 to 60 micromoles m-2 s-1. At equal fluences, blue light caused more desensitization when given at a fluence rate of 1.0 micromole m-2 s-1 than at 0.3 micromole m-2 s-1. In addition, seedlings irradiated with blue light at the higher fluence rate required a longer recovery time than seedlings irradiated at the lower fluence rate. A red light preirradiation, probably mediated via phytochrome, decreased the time required for recovery from desensitization. The minimum time for detectable recovery was about 65 s, and the maximum time observed was about 10 min. It is proposed that the descending arm of the fluence-response relationship for first positive phototropism is a consequence of desensitization, and that the time threshold for second positive phototropism establishes a period during which recovery from desensitization occurs.
The purpose of this study was to determine the effect of atomic oxygen (AO) exposure on the hydrophilicity of nine different polymers for biomedical applications. Atomic oxygen treatment can alter the chemistry and morphology of polymer surfaces, which may increase the adhesion and spreading of cells on Petri dishes and enhance implant growth. Therefore, nine different polymers were exposed to atomic oxygen and water-contact angle, or hydrophilicity, was measured after exposure. To determine whether hydrophilicity remains static after initial atomic oxygen exposure, or changes with higher fluence exposures, the contact angles between the polymer and water droplet placed on the polymer s surface were measured versus AO fluence. The polymers were exposed to atomic oxygen in a 100-W, 13.56-MHz radio frequency (RF) plasma asher, and the treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Pristine samples were compared with samples that had been exposed to AO at various fluence levels. Minimum and maximum fluences for the ashing trials were set based on the effective AO erosion of a Kapton witness coupon in the asher. The time intervals for ashing were determined by finding the logarithmic values of the minimum and maximum fluences. The difference of these two values was divided by the desired number of intervals (ideally 10). The initial desired fluence was then multiplied by this result (2.37), as was each subsequent desired fluence. The flux in the asher was determined to be approximately 3.0 x 10(exp 15) atoms/sq cm/sec, and each polymer was exposed to a maximum fluence of 5.16 x 10(exp 20) atoms/sq cm.
Isochronal and isothermal annealing studies were conducted on 0.1 and 2 ohm centimeter n(+)/p silicon cells after irradiation by 1 MeV electrons at fluences of 10 to the 14th power, 5 times 10 to the 14th power, and 10 to the 15th power per square centimeter. For the 0.1 ohm centimeter cells, reverse annealing was not observed in the isochronal data. However, reverse annealing was observed between approximately 200 and 325 C in the isochronal data of the 2 ohm centimeter cells. Isothermal annealing of 0.1 ohm centimeter cells at 500 C restored pre-irradiation maximum power P sub max within 20 minutes at fluence = 10 to the 14th power, in 180 minutes at fluence = 5 times 10 to the 14th power and to 92 percent of pre-irradiation P sub max in 180 minutes for fluence = 10 to the 15th power. Annealing at 450 C was found inadequate to restore 0.1 ohm centimeter cell performance within reasonable times for all fluence levels. By comparison, at 450 C, the P sub max of 2 ohm centimeter cells was restored within 45 minutes, for the two highest fluence levels, while for the lowest fluence, restoration was completed within 15 minutes. Spectral response data indicate that, for both resistivities, degradation occurs predominantly in the cells p-type base region.
Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.