Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Photon-HDF5: an open file format for single-molecule fluorescence experiments using photon-counting detectors

We introduce Photon-HDF5, an open and efficient file format to simplify exchange and long term accessibility of data from single-molecule fluorescence experiments based on photon-counting detectors such as single-photon avalanche diode (SPAD), photomultiplier tube (PMT) or arrays of such detectors. The format is based on HDF5, a widely used platform- and language-independent hierarchical file format for which user-friendly viewers are available. Photon-HDF5 can store raw photon data (timestamp, channel number, etc) from any acquisition hardware, but also setup and sample description, information on provenance, authorship and other metadata, and is flexible enough to include any kind of custom data. The format specifications are hosted on a public website, which is open to contributions by the biophysics community. As an initial resource, the website provides code examples to read Photon-HDF5 files in several programming languages and a reference python library (phconvert), to create new Photon-HDF5 files and convert several existing file formats into Photon-HDF5. As a result, to encourage adoption by the academic and commercial communities, all software is released under the MIT open source license.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic analysis of elemental mercury released from thermal decomposition of coal

Mercury (Hg) is a toxic and ubiquitous trace element in coal. Monitoring its release behavior during coal processing is a challenging problem. This paper presents a method that is capable of online measurement of the dynamic release behavior of elemental Hg (Hg{sup 0}) from thermal decomposition of coal. The method couples a temperature-programmed decomposition unit with an atomic fluorescence spectrometry detector (TPD-AFS). The AFS signal can be converted to Hg content for quantitative analysis through calibration. The main advantage of the TPD-AFS system is that it can provide either real-time or accumulated data. It was confirmed that the amount of Hg{sup 0} determined by this method agreed well with that by the Ontario-Hydro method, and the results are reproducible with a high accuracy. The method can be used to characterize the release behavior of Hg in coals upon heating and may be used to identify the forms of occurrence of Hg in coals. 16 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft X-ray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 {mu}m square. The array detector is mounted on a liquid cryogen-free {sup 3}He cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of {approx}0.01 sr and a maximum counting rate of more than 1 M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Average charge and its structure dependence of fragment ions under irradiation of a thin carbon foil with a 1-MeV/atom C{sub 3}{sup +} cluster ion

The charge states of fragment ions were measured for 1-MeV/atom C{sub 3}{sup +} cluster ions penetrating a carbon foil of 2.4-{mu}g/cm{sup 2} thickness. Those ions were detected by event-by-event mode with a fluorescent screen detector monitored by a charge-coupled device camera. The detected ion signals were traced by Coulomb explosion imaging technique, which enables us to classify charge states of each fragment ion and spatial arrangements of aligned cluster ions after emerging from the foil. Using this technique, we found the reduction of the average charge per ion. We also found that (i) the measured average charges of the aligned fragment ions in a linear-chain arrangement are larger than those in a triangular arrangement, and (ii) the edge-position ions in a linear-chain arrangement have the average charges greater than the middle-position ion. These experimental results are well supported by a recent refined theory on the cluster average charge.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements of hot-electron temperature in laser-irradiated plasmas

In a recently published work 1–3 we reported on measuring the total energy of hot electrons produced by the interaction of a nanosecond laser with planar CH-coated molybdenum targets, using the Mo K α emission. The temperature of the hot electrons in that work was determined by the high-energy bremsstrahlung [hard x-ray (HXR)] spectrum measured by a three-channel fluorescence-photomultiplier detector (HXRD). In the present work, we replaced the HXRD with a nine-channel image-plate (IP)–based detector (HXIP). For the same conditions (irradiance of the order of 10 14 W/cm 2 ; 2-ns pulses) the measured temperatures are consistently lower than those measured by the HXRD (by a factor ~1.5 to 1.7). In addition, we supplemented this measurement with three experiments that measure the hot-electron temperature using K α line-intensity ratios from high-Z target layers, independent of the HXR emission. These experiments yielded temperatures that were consistent with those measured by the HXIP. We showed that the thermal x-ray radiation must be included in the derivation of total energy in hot electrons (E hot ), and that this makes E hot only weakly dependent on hot-electron temperature. For a given x-ray emission in inertial confinement fusion compression experiments, this result would lead to a higher total energy in hot electrons, but the preheat of the compressed fuel may be lower because of the reduced hot-electron range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MSFC large-area imaging multistep proportional counter

A large-area multistep imaging proportional counter that is being currently developed at the Marshall Space Flight Center is described. The device, known as a multistep fluorescence gated detector, consists of a multiwire proportional counter (MWPC) with a preamplification region. The MWCP features superior spatial resolution with a very high degree of background rejection. It is ideally suited for use in X-ray astronomy in 20-100 keV energy range. The paper includes the MWPC schematic and a list of instrument specifications.

Ramsey, B. D.↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Picosecond wide-field time-correlated single photon counting fluorescence microscopy with a delay line anode detector

We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reduced lifetime near the coverslip in TIR compared to epifluorescence FLIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing hadronic-model predictions of depth of maximum of air-shower profiles and ground-particle signals using hybrid data of the Pierre Auger Observatory

We test the predictions of hadronic interaction models regarding the depth of maximum of air-shower profiles, X max , and ground-particle signals in water-Cherenkov detectors at 1000 m from the shower core, S ( 1000 ) , using the data from the fluorescence and surface detectors of the Pierre Auger Observatory. The test consists of fitting the measured two-dimensional ( S ( 1000 ) , X max ) distributions using templates for simulated air showers produced with hadronic interaction models pos-, et--04, 2.3d and leaving the scales of predicted X max and the signals from hadronic component at ground as free-fit parameters. The method relies on the assumption that the mass composition remains the same at all zenith angles, while the longitudinal shower development and attenuation of ground signal depend on the mass composition in a correlated way. The analysis was applied to 2239 events detected by both the fluorescence and surface detectors of the Pierre Auger Observatory with energies between 10 18.5 eV to 10 19.0 eV and zenith angles below 60°. We found, that within the assumptions of the method, the best description of the data is achieved if the predictions of the hadronic interaction models are shifted to deeper X max values and larger hadronic signals at all zenith angles. Given the magnitude of the shifts and the data sample size, the statistical significance of the improvement of data description using the modifications considered in the paper is larger than 5 σ even for any linear combination of experimental systematic uncertainties. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Silicon Drift Detector Array: An X-ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Silicon Drift Detector Array: An X-Ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

Gaskin, Jessica A.↗

TU-F-18A-05: An X-Ray Fluorescence Technique for Energy Calibration of Photon-Counting Detectors

Purpose: To investigate the feasibility of energy response calibration of a Si strip photon-counting detector by using the x-ray fluorescence technique. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on Si strips. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing Ag, I, Ba, and Gd, were placed in small plastic aliquots with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known energies for materials. The energy resolution was derived from the full width at half maximum (FWHM) of the fluorescence peaks. In addition, the angular dependence of the recorded fluorescence spectra was studied at 30°, 60°, and 120°. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The recorded pulse height was calibrated with respect to photon energy and the gain and offset values were calculated to be 7.0 mV/keV and −69.3 mV, respectively. Negligible variation in energy calibration was observed among the four energy thresholds. The variation among different pixels was estimated to be approximately 1 keV. The energy resolution of the detector was estimated to be 7.9% within the investigated energy range. Conclusion: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique provides an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for photons with energies above 10 18 eV using the hybrid detector of the Pierre Auger Observatory

A search for ultra-high energy photons with energies above 1 EeV is performed using nine years of data collected by the Pierre Auger Observatory in hybrid operation mode. An unprecedented separation power between photon and hadron primaries is achieved by combining measurements of the longitudinal air-shower development with the particle content at ground measured by the fluorescence and surface detectors, respectively. Only three photon candidates at energies 1 - 2 EeV are found, which is compatible with the expected hadron-induced background. Upper limits on the integral flux of ultra-high energy photons of 0.027, 0.009, 0.008, 0.008 and 0.007 km$^{-2}$ sr$^{-1}$ yr$^{-1}$ are derived at 95% C.L. for energy thresholds of 1, 2, 3, 5 and 10 EeV. These limits bound the fractions of photons in the all-particle integral flux below 0.1%, 0.15%, 0.33%, 0.85% and 2.7%. For the first time the photon fraction at EeV energies is constrained at the sub-percent level. The improved limits are below the flux of diffuse photons predicted by some astrophysical scenarios for cosmogenic photon production. Here, the new results rule-out the early top-down models $-$ in which ultra-high energy cosmic rays are produced by, e.g., the decay of super-massive particles $-$ and challenge the most recent super-heavy dark matter models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding the bias introduced in quantum dot blinking using change point analysis

Quantum dots are semiconductor crystals that are less than 100 nanometers in size; that is, between 1 billionth and 100 billionths of a meter. They can be composed of one semiconductor material or a core of one semiconductor surrounded by a shell of another. The quantum dots studied in this work consisted of a cadmium selenide core surrounded by a cadmium sulfide shell. When a quantum dot is illuminated with light, some of it can be absorbed and excites the quantum dot to a higher energy state. To relax back down to its resting state, light can be emitted in the form of fluorescence. The nature of the fluorescence that is emitted from a single quantum dot differs from that which is emitted from a bulk sample (usually a solid film or a solution of quantum dots). While in bulk samples the fluorescence over time fluctuates randomly about some average, maintaining a continuous average intensity, single quantum dot fluorescence switches between two or more intensities. This phenomenon is referred to as quantum dot blinking, and its origin is of significant relevance to solar cell, light emitting diode and biological tracking applications. Quantum dot blinking can be studied by exciting an isolated quantum dot with light and recording the ensuing fluorescence using sensitive detectors. This is done over many minutes, resulting in a fluorescence intensity (in counts per second) versus time trajectory. These trajectories must be further analyzed in order to understand the nature of the blinking behavior. Conventionally, a bin and threshold analysis is used, whereby the arrival times of fluorescent photons are binned to reduce the signal noise, and a threshold is used to separate the trajectory into periods of high and low fluorescence. In this study, the effects of bin size and threshold on the blinking kinetics were investigated, and the assumption that there is only one bright and one dark state was tested. To do so, a statistically rigorous method called change point analysis was needed which does not require binning and which can determine the number of intensity levels present. Blinking in 17 quantum dots was studied using both analysis methods. The primary parameter that was compared between the two methods is called a truncation time. Increasing the bin size was found to generally lead to a larger truncation time while increasing the threshold always decreased the truncation time. Using the change point analysis method, 12 out of 17 quantum dots were found to exhibit more than two intensity levels. Lastly, the assumption that only two intensity levels exist was found to significantly affect the blinking statistics: when individual levels were combined into one bright level, the truncation time would increase. The change point analysis method was found to be more suitable for studying multilevel blinking in quantum dots than the conventional bin and threshold method, since the effects of binning and thresholding can be alleviated and the two-level assumption relaxed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗