Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SCAMP: Rapid Focused Sonic Boom Waypoint Flight Planning Methods, Execution, and Results

Successful execution of the flight phase of the Superboom Caustic Analysis and Measurement Project (SCAMP) required accurate placement of focused sonic booms on an array of prepositioned ground sensors. While the array was spread over a 10,000-ft-long area, this is a relatively small region when considering the speed of a supersonic aircraft and sonic boom ray path variability due to shifting atmospheric conditions and aircraft trajectories. Another requirement of the project was to determine the proper position for a microphone-equipped motorized glider to intercept the sonic boom caustic, adding critical timing to the constraints. Variability in several inputs to these calculations caused some shifts of the focus away from the optimal location. Reports of the sonic booms heard by persons positioned amongst the array were used to shift the focus closer to the optimal location for subsequent passes. This paper describes the methods and computations used to place the focused sonic boom on the SCAMP array and gives recommendations for their accurate placement by future quiet supersonic aircraft. For the SCAMP flights, 67% of the foci were placed on the ground array with measured positions within a few thousand feet of computed positions. Among those foci with large caustic elevation angles, 96% of foci were placed on the array, and measured positions were within a few hundred feet of computed positions. The motorized glider captured sonic booms on 59% of the passes when the instrumentation was operating properly.

Haering, Edward A., Jr.↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

ION focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

Cooks, Robert Graham↗

Focusing transformers/filters in isotropic/anisotropic piezoelectrics

A focusing interdigital transducer (IDT) and corresponding single- and dual-port piezoelectric devices are disclosed. The focusing interdigital transducer, which generates Lamé acoustic waves, permits operation at significantly higher frequencies than those possible with traditional IDTs. The focusing IDT employs multiple arced fingers formed both above and below the piezoelectric layer to improve coupling efficiency by coupling through both the e31 and e33 piezoelectric coefficients to the piezoelectric layer. By optimizing both anchor design and location, acoustic wave losses are minimized, thereby improving the device's quality factor Q. Through proper bus design and selection of the number of IDT fingers, a device's impedance can be tuned for a given application. The focusing IDTs may be used in single-port filter devices and dual-port transformer devices. The single- and dual-port devices may operate at a single frequency, at two frequencies, or over a band of frequencies.

Siddiqui, Aleem↗

Ion focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

Cooks, Robert Graham↗

Ion focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

Cooks, Robert Graham↗

Ion focusing

The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

Cooks, Robert Graham↗

Coaxial color channel focus evaluation to estimate standoff height in directed energy deposition additive manufacturing

Directed energy deposition (DED) is an additive manufacturing process that is being rapidly adopted by industry and is well suited for the fabrication of complex components in a variety of metal alloys. In laser cladding systems such as DED, powder is blown in a stream to a metal substrate coincident with a laser necessary to deposit molten metal with 3D spatial control. The focus of both the laser and the powder stream are crucial, and best deposition occurs at a predetermined standoff height between the build surface and the print head. Generally, no monitoring of this distance is implemented in commercial DED systems. Due to potential over or under building, the standoff height often changes over time but tends to self-correct. However, inexpensive and minimally intrusive methods to identify optimal standoff are required to provide real-time control to maintain the optimal distance. The present work explores the quantification of the focus of the three-color channels of a coaxial camera to determine the standoff height. An experiment was performed in which a 254 mm wall is built and the standoff height, initially 5.0 mm below the optimal position, was then intentionally increased every 25.4 mm of wall length by an amount of 1.0 mm to a final position 7.0 mm above optimal. Computer vision is demonstrated to monitor the amount of focus in each color band and estimate standoff distance. Finally, a response can be calculated in under 40 ms using simple hardware and can work in most laser-based DED systems.

36 MATERIALS SCIENCE↗

SuperKEKB beam final focus superconducting magnet system

The SuperKEKB was designed and constructed as the upgraded accelerator of KEKB. In this accelerator design, the nano-beam scheme of collision was applied and a luminosity of 8 x10 35 cm -2 s -1 was targeted. In the design, the beam final focus system was the key component in the accelerator hardware elements. This final focus system consists of 55 superconducting magnets. In this paper, the designs of the magnets, the cryostats and the cryogenic system are shown, and the field measurement results are reported. The SuperKEKB beam operation with the final focus system started on 2018 March 19, and the magnet quench events up to 2020 December 16 are described.

43 PARTICLE ACCELERATORS↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Quantifying Dissolution Dynamics in Porous Media Using a Spatial Flow Focusing Profile

Abstract The diverse range of patterns in porous media formed by dissolution processes depends on the relative magnitude of flow, transport, and chemical reactions at pore surfaces. However, distinguishing between regimes often relies solely on qualitative, visual comparisons of emergent structures. Here, we propose a quantitative measure capable of identifying different regimes using the concept of the spatial flow focusing profile, which segments the medium into cross sections along the flow direction to calculate the flow focusing index for each section. We employ this measure in numerical simulations of a dissolving porous medium using a pore network model. We obtain a morphological phase diagram of dissolution patterns, which we characterize using the flow focusing profile. In particular, we demonstrate that analyzing the temporal changes in the profile allows one to quantitatively distinguish between wormholing and channeling. The transition between them is shown to be affected by the heterogeneity of the system.

58 GEOSCIENCES↗

Advances in laser-based bremsstrahlung x-ray sources. II. Laser pulse propagation and guiding in nonuniform plasma media in the presence of self-focusing

An analytic Wentzel–Kramers–Brillouin model is presented of Gaussian laser pulse propagation through plasma with a quadratic transverse density profile and an arbitrarily varying, longitudinal density gradient under conditions of nonlinear self-focusing. From these solutions, it is shown that in the absence of nonlinear self-focusing and transverse nonuniformity, for exponential pre-plasma density profiles, the use of a low density coating of the laser target with electron density n0∼11 ncr (e.g., a CH foam of density 35 mg/cm3 for 1-micron laser light) maximizes laser intensity at best focus. Also, under laser and plasma conditions relevant to recent experiments on high-power laser systems, conditions are obtained for a Gaussian laser pulse to propagate stably through the pre-plasma medium. Such conditions would be expected to enhance the production of relativistic electrons from laser-target coupling, providing a possible explanation for the observed increase in MeV photon dose and enabling applications such as laser-based MeV X-ray radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of self-generated magnetic fields in focused ion beams driven by intense picosecond laser pulses

We investigate the physics of ion beam focusing in the interaction of intense picosecond laser pulses with concave foils, using two-dimensional particle-in-cell simulations. Curved targets have been observed to deliver brighter multi-MeV ion beams than flat targets, and they could be used to ignite pre-compressed ICF fusion capsules in a scheme called ion fast ignition. Focusing is achieved by shaping the target and relying on an ion acceleration mechanism in which the ions are accelerated normal to the target surface; subsequently, the plasma expansion grows magnetic fields that advect with the plasma and deflect ions away from the target symmetry axis, causing the focal spot to shift downstream from its geometric location. The drop in both electric and magnetic field strengths in the expanding plasma makes the ion beam envelope asymmetric with respect to the focusing plane.

Focused ion beam↗

Focusing with saw-tooth refractive lenses at a high-energy X-ray beamline

The Advanced Photon Source 1-ID beamline, operating in the 40–140 keV X-ray energy range, has successfully employed continuously tunable saw-tooth refractive lenses to routinely deliver beams focused in both one and two dimensions to experiments for over 15 years. The practical experience of implementing such lenses, made of silicon and aluminium, is presented, including their properties, control, alignment, and diagnostic methods, achieving ∼1 µm focusing (vertically). Ongoing development and prospects towards submicrometre focusing at these high energies are also mentioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Viscoelastic Particle Focusing and Separation in a Spiral Channel

As one type of non-Newtonian fluid, viscoelastic fluids exhibit unique properties that contribute to particle lateral migration in confined microfluidic channels, leading to opportunities for particle manipulation and separation. In this paper, particle focusing in viscoelastic flow is studied in a wide range of polyethylene glycol (PEO) concentrations in aqueous solutions. Polystyrene beads with diameters from 3 to 20 μm are tested, and the variation of particle focusing position is explained by the coeffects of inertial flow, viscoelastic flow, and Dean flow. We showed that particle focusing position can be predicted by analyzing the force balance in the microchannel, and that particle separation resolution can be improved in viscoelastic flows.

42 ENGINEERING↗

Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗