Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fourier Transform Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hydrogen-Broadened Water from 50 to 300 cm-1 and 1300 to 4000 cm-1

To support remote sensing of the outer planets, absorption spectra of H2O broadened by H2 were recorded at room temperature using two Fourier transform spectrometers. The data from 1300 to 4000 cm-1 were obtained at 0.012 cm-1 resolution with the McMath FTS located at Kitt Peak National Observatory/National Solar Observatory. The remainder of the spectral data from 55 to 320 cm-1 were taken at 0.0056 cm-1 with the Bruker FTS.

remote sensing outer planets absorption spectra Fo↗

The v 1 -v 2 , v 3 -v 2 , v 1 , and v 3 bands of H 2 16 O: line positions and strengths

High-resolution spectra of H 2 16 O were recorded with a Fourier-transform spectrometer covering transitions in the (100)-(010), (001)-(010), (100)-(000), and (001)-(000) bands. The measured line frequencies were used to determine high accuracy values of rotational energy levels in the (100) and (001) vibrational states. The experimental results provide a more accurate representation of the line positions and strengths than those presently available for these bands.

Fourier-transform↗

Infrared spectroscopic remote sensing from the Cassini orbiter

An infrared spectroscopy instrument for infrared remote sensing from the Cassini orbiter is being breadboarded in the laboratory. The Composite Infrared Spectrometer (CIRS) consists of a pair of Fourier Transform Spectrometers (FTS) which together cover the range from 10 - 1400/cm with a spectral resolution up to 0.5/cm. The far-infrared FTS is a polarizing interferometer covering the 10 - 300/cm range. The mid-infrared FTS is a conventional Michelson FTS covering 200 - 1400/cm in three spectral channels. CIRS will retrieve information on the atmospheres of Titan and Saturn with good vertical resolution, from deep in their tropospheres to high in their stratospheres, and into the upper few centimeters of the regoliths of icy objects. The science objectives and design of CIRS are discussed.

Kunde, V.↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗

Early Results on the Saturn System from the Composite Infrared Spectrometer

The Composite Infrared Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wavenumber, from 10 to 1400 /cm (1 mm to 7 microns), with a spectral resolution that can be set from 0.5 to 15.5 /cm. The far infrared portion of the spectrum (10-600 /cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600-1100 /cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. More complete descriptions of the instrument and investigation are given in and. A brief description of the first results from observations through the Saturn orbital insertion period can be found in.

Flasar, F. M.↗

Tropospheric and Airborne Emission Spectrometers

X This paper describes the development of two related instruments, the Tropospheric Emission Spectrometer (TES) and the Airborne Emission Spectrometer (AES). Both instruments are infrared imaging Fourier Transform Spectrometers, used for measuring the state of the lower atmosphere, and in particular the measurement of ozone and ozone sources and sinks.

mission to planet earth global atmospheric models↗

Simple Parametric Model for Intensity Calibration of Cassini Composite Infrared Spectrometer Data

Accurate intensity calibration of a linear Fourier-transform spectrometer typically requires the unknown science target and the two calibration targets to be acquired under identical conditions. We present a simple model suitable for vector calibration that enables accurate calibration via adjustments of measured spectral amplitudes and phases when these three targets are recorded at different detector or optics temperatures. Our model makes calibration more accurate both by minimizing biases due to changing instrument temperatures that are always present at some level and by decreasing estimate variance through incorporating larger averages of science and calibration interferogram scans.

Brasunas, J.↗

Measurements of Line Positions and Strengths of HD O-18 and D2 O-18 in the 2500-4280 cm(exp -1) Region

Measurements of line positions and strengths of D2 O-18 and HD O-18 were obtained with a Fourier transform spectrometer. The data were analyzed to obtain energy levels of the (100), (020), and (001) vibrational states of HD O-18 and the (001) and (011) states of D2 O-18 and the vibrational bands of these states connected to the ground state covered the spectral region from 2500 to 4278 cm(exp -1). 456 absorption lines of D2 O-18 and 856 lines of HD O-18 were assigned from the spectra. The measurements were of oxygen-18 enriched samples of deuterated water vapor and the spectra also contained features of HD O-16, D2 O-16, H2 O-16, H2 O-17 and H2 O-18 of which several were used as frequency calibration standards.

Fourier transform spectrometer (FTS)↗

In-Flight Performance of the TES Loop Heat Pipe Rejection System: Seven Years in Space

The Tropospheric Emission Spectrometer (TES) is an infrared, high spectral resolution Fourier transform spectrometer with a 3.3 to 15.4 micron wavelength coverage. TES is a scanning instrument intended for determining the chemical state of the Earth's lower atmosphere (troposphere) from the surface to 30+ km. TES produces vertical profiles of important pollutant and greenhouse gases such as carbon monoxide, ozone, methane, and water vapor on a global scale every other day. TES was launched into orbit onboard NASA's earth Observing System Aura spacecraft on July 15, 2004 from Vandenberg Air Force Base, California.

tropospheric emission spectrometer↗

Cryogenic Fourier spectrometer for measuring trace species in the lower stratosphere

A cryogenic Fourier transform spectrometer has been built to measure thermal emission of the earth's limb from a balloon-borne platform. Liquid nitrogen cooling of the spectrometer and liquid helium cooling of the detectors has provided sufficient sensitivity to detect, at 5-15 microns, fifteen molecular species relevant to stratospheric ozone chemistry. The spectral resolution achieved, 0.022/cm, is the best yet attained for emission mode data at these wavelengths. The philosophy behind the design of the optical and electronic systems is presented, followed by an analysis of the performance achieved during balloon flight.

Brasunas, John C.↗

Nadir Measurements of Carbon Monoxide Distributions by the Tropospheric Emission Spectrometer Instrument Onboard the Aura Spacecraft: Overview of Analysis Approach and Examples of Initial Results

We provide an overview of the nadir measurements of carbon monoxide (CO) obtained thus far by the Tropospheric Emission Spectrometer (TES). The instrument is a high resolution array Fourier transform spectrometer designed to measure infrared spectral radiances from low Earth orbit. It is one of four instruments successfully launched onboard the Aura platform into a sun synchronous orbit at an altitude of 705 km on July 15, 2004 from Vandenberg Air Force Base, California. Nadir spectra are recorded at 0.06/cm spectral resolution with a nadir footprint of 5 x 8 km. We describe the TES retrieval approach for the analysis of the nadir measurements, report averaging kernels for typical tropical and polar ocean locations, characterize random and systematic errors for those locations, and describe instrument performance changes in the CO spectral region as a function of time. Sample maps of retrieved CO for the middle and upper troposphere from global surveys during December 2005 and April 2006 highlight the potential of the results for measurement and tracking of global pollution and determining air quality from space.

carbon monoxide↗

Apodization Control of Line Shape in Spectrometer

Kaiser-Bessel apodization function reduces unwanted sidebands. Report discusses apodization in Fourier-transform spectrometer (FTS) for Advanced Moisture and Temperature Sounder (AMTS). Purpose of apodization in instrument to control shape of spectrum in wavenumber space to keep radiation at other wavelengths in passband of spectrometer out of AMTS wavenumber channel.

Pires, Antonio↗

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.↗

Space-Based Near-Infrared CO2 Measurements: Testing the Orbiting Carbon Observatory Retrieval Algorithm and Validation Concept Using SCIAMACHY Observations over Park Falls, Wisconsin

Space-based measurements of reflected sunlight in the near-infrared (NIR) region promise to yield accurate and precise observations of the global distribution of atmospheric CO2. The Orbiting Carbon Observatory (OCO) is a future NASA mission, which will use this technique to measure the column-averaged dry air mole fraction of CO2 (XCO2) with the precision and accuracy needed to quantify CO2 sources and sinks on regional scales (approx.1000 x 1000 sq km and to characterize their variability on seasonal timescales. Here, we have used the OCO retrieval algorithm to retrieve XCO2 and surface pressure from space-based Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY) measurements and from coincident ground-based Fourier transform spectrometer (FTS) measurements of the O2 A band at 0.76 mm and the 1.58 mm CO2 band for Park Falls,Wisconsin. Even after accounting for a systematic error in our representation of the O2 absorption cross sections, we still obtained a positive bias between SCIAMACHY and FTS XCO2 retrievals of approx.3.5%. Additionally, the retrieved surface pressures from SCIAMACHY systematically underestimate measurements of a calibrated pressure sensor at the FTS site. These findings lead us to speculate about inadequacies in the forward model of our retrieval algorithm. By assuming a 1% intensity offset in the O2 A band region for the SCIAMACHY XCO2 retrieval, we significantly improved the spectral fit and achieved better consistency between SCIAMACHY and FTS XCO2 retrievals. We compared the seasonal cycle of XCO2 at Park Falls from SCIAMACHY and FTS retrievals with calculations of the Model of Atmospheric Transport and Chemistry/Carnegie-Ames-Stanford Approach (MATCH/CASA) and found a good qualitative agreement but with MATCH/CASA underestimating the measured seasonal amplitude. Furthermore, since SCIAMACHY observations are similar in viewing geometry and spectral range to those of OCO, this study represents an important test of the OCO retrieval algorithm and validation concept using NIR spectra measured from space. Finally, we argue that significant improvements in precision and accuracy could be obtained from a dedicated CO2 instrument such as OCO, which has much higher spectral and spatial resolutions than SCIAMACHY. These measurements would then provide critical data for improving our understanding of the carbon cycle and carbon sources and sinks.

carbon dioxide↗

Airborne Lidar Observations of the Stratosphere After the Pinatubo Eruption

The eruption of Mt. Pinatubo in June 1991 injected the largest mass of gases and ash into the stratosphere observed since lidar and satellite monitoring of the stratosphere became possible in the middle 1960's. Because of early indications of the significance of the eruption, NASA mounted an airborne mission to survey the stratospheric plume soon after the eruption. The NASA Wallops Electra aircraft was outfitted with a depolarization lidar, a correlation spectrometer (for SO2 measurements), a total-direct-diffuse spectral radiometer, and a Fourier transform spectrometer. Six flights were made during the period July 7-14.

Winker, David M.↗