At least 109 records · Page 6

Observation of a massive phason in a charge-density-wave insulator

The lowest-lying fundamental excitation of an incommensurate charge density wave (CDW) material is widely believed to be a massless phason -- a collective modulation of the phase of the CDW order parameter. However, as first pointed out by Lee and Fukuyama, long-range Coulomb interactions should push the phason energy up to the plasma energy of the CDW condensate, resulting in a massive phason and a fully gapped spectrum. Whether such behavior occurs in a CDW system has been unresolved for more than four decades. Using time-domain THz emission spectroscopy, we investigate this issue in the material (TaSe 4 ) 2 I, a classical example of a quasi-one-dimensional CDW insulator. Upon transient photoexcitation at low temperatures, we find the material strikingly emits coherent, narrow-band THz radiation. The frequency, polarization and temperature-dependence of the emitted radiation imply the existence of a phason that acquires mass by coupling to long-range Coulomb interaction. Our observations constitute the first direct evidence of the massive "Lee-Fukuyama" phason and highlight the potential applicability of fundamental collective modes of correlated materials as compact and robust sources of THz radiation.

36 MATERIALS SCIENCE↗

Quasiclassical Computations of Compton-Scattered Spectra

Quality X-ray sources are crucial to fundamental physics research, medical radiology, humanities research, and materials science. While synchrotron radiation (SR) facilities produce the state-of-the-art emissions with respect to brilliance and frequency tunability, the great expense required to build, maintain, and operate these structures greatly limits their accessibility to researchers. Much of the research conducted at SR facilities, however, may be conducted with inverse Compton sources (ICS). Accelerator-based Compton scattering light sources generate high-energy, high-brilliance emissions. Compton scattering is the process by which a photon scatters o? an electron. ICS offer an affordable, in-lab alternative to SR facilities. Even though SR facilities produce greater intensity emissions, Compton sources provide the same frequency tunability at the intensities suitable for the purposes of many researchers currently fighting for time at SR facilities, i.e., ICS provides intensities suitable for contrast imaging, X-ray fluorescence, X-ray-diffraction, and X-ray spectroscopy. The focus of this work is to create computational models to simulate Compton-scattered spectra. These models have been used to build a theoretical basis for methods of improving the quality of future Compton sources and to preform diagnostic analysis of existing light sources. The theoretical basis of each model is derived from first principles. The numerical methods employed by each model are defined. A full description of the various functionalities of each code will be addressed. Furthermore, an in-depth analysis of spectral bandwidth sources is discussed. The complex physics arising from an extremely high-intensity, nonlinear laser pulse is explored in detail. Methods of frequency modulation of the incident laser, i.e., a method for correcting the nonlinear broadening effects on the scattered spectrum, will also be discussed. The work will conclude with a an exploration of the ongoing research efforts regarding regimes of operation outside of the limits of these current models.

Johnson, Erik↗

Decoupling excitons from high-frequency vibrations in organic molecules

The coupling of excitons in π-conjugated molecules to high-frequency vibrational modes, particularly carbon–carbon stretch modes (1,000–1,600 cm -1 ) has been thought to be unavoidable. These high-frequency modes accelerate non-radiative losses and limit the performance of light-emitting diodes, fluorescent biomarkers and photovoltaic devices. Here, by combining broadband impulsive vibrational spectroscopy, first-principles modelling and synthetic chemistry, we explore exciton–vibration coupling in a range of π-conjugated molecules. We uncover two design rules that decouple excitons from high-frequency vibrations. First, when the exciton wavefunction has a substantial charge-transfer character with spatially disjoint electron and hole densities, we find that high-frequency modes can be localized to either the donor or acceptor moiety, so that they do not significantly perturb the exciton energy or its spatial distribution. Second, it is possible to select materials such that the participating molecular orbitals have a symmetry-imposed non-bonding character and are, thus, decoupled from the high-frequency vibrational modes that modulate the π-bond order. We exemplify both these design rules by creating a series of spin radical systems that have very efficient near-infrared emission (680–800 nm) from charge-transfer excitons. We show that these systems have substantial coupling to vibrational modes only below 250 cm -1 , frequencies that are too low to allow fast non-radiative decay. This enables non-radiative decay rates to be suppressed by nearly two orders of magnitude in comparison to π-conjugated molecules with similar bandgaps. Our results show that losses due to coupling to high-frequency modes need not be a fundamental property of these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenic 160-GHz MMIC Heterodyne Receiver Module

A cryogenic 160-GHz MMIC heterodyne receiver module has demonstrated a system noise temperature of 100 K or less at 166 GHz. This module builds upon work previously described in Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation (NPO-47664), NASA Tech Briefs, Vol. 35, No. 8 (August 2011), p. 27. In the original module, the local oscillator signal was saturating the MMIC low-noise amplifiers (LNAs) with power. In order to suppress the local oscillator signal from reaching the MMIC LNAs, the W-band (75 110 GHz) signal had to be filtered out before reaching 140 170 GHz. A bandpass filter was developed to cover 120 170 GHz, using microstrip parallel-coupled lines to achieve the desired filter bandwidth, and ensure that the unwanted W-band local oscillator signal would be sufficiently suppressed. With the new bandpass filter, the entire receiver can work over the 140 180-GHz band, with a minimum system noise temperature of 460 K at 166 GHz. The module was tested cryogenically at 20 K ambient temperature, and it was found that the receiver had a noise temperature of 100 K over an 8-GHz bandwidth. The receiver module now includes a microstrip bandpass filter, which was designed to have a 3-dB bandwidth of approximately 120-170 GHz. The filter was fabricated on a 3-mil-thick alumina substrate. The filter design was based on a W-band filter design made at JPL and used in the QUIET (Q/U Imaging ExperimenT) radiometer modules. The W-band filter was scaled for a new center frequency of 150 GHz, and the microstrip segments were changed accordingly. Also, to decrease the bandwidth of the resulting scaled design, the center gaps between the microstrip lines were increased (by four micrometers in length) compared to the gaps near the edges. The use of the 150-GHz bandpass filter has enabled the receiver module to function well at room temperature. The system noise temperature was measured to be less than 600 K (at room temperature) from 154 to 168 GHz. Additionally, the use of a W-band isolator between the receiver module and the local oscillator source also improved the noise temperature substantially. This may be because the mixer was presented with a better impedance match with the use of the isolator. Cryogenic testing indicates a system noise temperature of 100 K or less at 166 GHz. Prior tests of the MMIC amplifiers alone have resulted in a system noise temperature of 65.70 K in the same frequency range (.160 GHz) when cooled to an ambient temperature of 20 K. While other detector systems may be slightly more sensitive (such as SIS mixers), they require more cooling (to 4 K ambient) and are not as easily scalable to build a large array, due to the need for large magnets and other equipment. When cooled to 20 K, this receiver module achieves approximately 100 K system noise temperature, which is slightly higher than single-amplifier module results obtained at JPL (65.70 K when an amplifier is corrected for back-end noise contributions). If this performance can be realized in practice, and a scalable array can be produced, the impact on cosmic microwave background experiments, astronomical and Earth spectroscopy, interferometry, and radio astronomy in general will be dramatic.

Samoska, Lorene A.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The HYSPIRI Decadal Survey Mission: Update on the Mission Concept and Science Objectives for Global Imaging Spectroscopy and Multi-Spectral Thermal Measurements

The NASA HyspIRI mission is planned to provide global solar reflected energy spectroscopic measurement of the terrestrial and shallow water regions of the Earth every 19 days will all measurements downlinked. In addition, HyspIRI will provide multi-spectral thermal measurements with a single band in the 4 micron region and seven bands in the 8 to 12 micron region with 5 day day/night coverage. A direct broadcast capability for measurement subsets is also planned. This HyspIRI mission is one of those designated in the 2007 National Research Council (NRC) Decadal Survey: Earth Science and Applications from Space. In the Decadal Survey, HyspIRI was recognized as relevant to a range of Earth science and science applications, including climate: "A hyperspectral sensor (e.g., FLORA) combined with a multispectral thermal sensor (e.g., SAVII) in low Earth orbit (LEO) is part of an integrated mission concept [described in Parts I and II] that is relevant to several panels, especially the climate variability panel." The HyspIRI science study group was formed in 2008 to evaluate and refine the mission concept. This group has developed a series of HyspIRI science objectives: (1) Climate: Ecosystem biochemistry, condition & feedback; spectral albedo; carbon/dust on snow/ice; biomass burning; evapotranspiration (2) Ecosystems: Global plant functional types, physiological condition, and biochemistry including agricultural lands (3) Fires: Fuel status, fire frequency, severity, emissions, and patterns of recovery globally (4) Coral reef and coastal habitats: Global composition and status (5) Volcanoes: Eruptions, emissions, regional and global impact (6) Geology and resources: Global distributions of surface mineral resources and improved understanding of geology and related hazards These objectives are achieved with the following measurement capabilities. The HyspIRI imaging spectrometer provides: full spectral coverage from 380 to 2500 at 10 nm sampling; 60 m spatial sampling with a 150 km swath; and fully downlinked coverage of the Earth's terrestrial and shallow water regions every 19 days to provide seasonal cloud-free coverage of the terrestrial surface. The HyspIRI Multi-Spectral Thermal instrument provides: 8 spectral bands from 4 to 12 microns; 60 m spatial sampling with a 600 km swath; and fully downlinked coverage of the Earth's terrestrial shallow water regions every 5 days (day/night) to provide nominally cloud-free monthly coverage. The HyspIRI mission also includes an on-board processing and direct broadcast capability, referred to as the Intelligent Payload Module (IPM), which will allow users with the appropriate antenna to download a subset of the HyspIRI data stream to a local ground station. These science and science application objectives are critical today and uniquely addressed by the combined imaging spectroscopy, thermal infrared measurements, and IPM direct broadcast capability of HyspIRI. Two key objectives are: (1) The global HyspIRI spectroscopic measurements of the terrestrial biosphere including vegetation composition and function to constrain and reduce the uncertainty in climate-carbon interactions and terrestrial biosphere feedback. (2) The global 8 band thermal measurements to provide improved constraint of fire related emissions. In this paper the current HyspIRI mission concept that has been reviewed and refined to its current level of maturity with a Data Products Symposium, Science Workshop and NASA HWorkshop is presented including traceability between the measurements and the science and science application objectives.

Green, Robert O.↗

Technology Development of Miniaturized Far-Infrared Sources for Biomolecular Spectroscopy

The objective of this project was to develop a purely solid-state based, thus miniaturized, far-infrared (FIR) (also known as terahertz (THz)) wave source using III-V semiconductor nanostructures for biomolecular detection and sensing. Many biomolecules, such as DNA and proteins, have distinct spectroscopic features in the FIR wavelength range as a result of vibration-rotation-tunneling motions and various inter- and intra-molecule collective motions. Spectroscopic characterization of such molecules requires narrow linewidth, sufficiently high power, tunable (in wavelength), and coherent FIR sources. Unfortunately, the FIR frequency is one of the least technologically developed ranges in the electromagnetic spectrum. Currently available FIR sources based on non-solid state technology are bulky, inefficient, and very often incoherent. In this project we investigated antimonide based compound semiconductor (ABCS) nanostructures as the active medium to generate FIR radiation. The final goal of this project was to demonstrate a semiconductor THz source integrated with a pumping diode laser module to achieve a compact system for biomolecular applications.

Kono, Junichiro↗

Examining Metal Identity and Proximity Effects on Acetylene Hydrogenation with Azolate-Based MOFs

Liquid organic hydrogen carriers (LOHCs) are an attractive fuel source due to their compatibility with existing transportation methods and ease of use. However, they suffer from sluggish (de)hydrogenation kinetics. One promising platform for developing next-generation catalysts is metal–organic frameworks (MOFs), which can enable systematic interrogation into the influence of metal identity and spatial arrangement. In this study, the effect of the coordination environment was investigated using Ni- and Co-based azolate MOFs: MFU-4l-OH (M x Zn 5–x (OH) 4 (BTDD) 3 ; x = 4 for M = Co and x = 3 for M = Ni, H 2 BTDD = bis(1H-1,2,3-triazolo[4,5-b][4′,5′-i])dibenzo[1,4]dioxin), composed of single-site nodes, and M(OH) 2 BBTA (M = Ni, Co; H 2 BBTA = 1H,5H-benzo(1,2-d:4,5-d’)bistriazole), composed of extended chain-type nodes. The catalysts were characterized by isotherms, powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), inductively coupled plasma-optical emission spectroscopy (ICP-OES), and X-ray photoelectron spectroscopy (XPS) analysis. Acetylene hydrogenation activity under steady state conditions (150 °C, 1:1 C 2 H 2 :H 2 ) revealed higher turnover frequencies (TOFs) up 1.17 × 10 –2 mol C 2 H 2 mol −1 Ni min −1 and 1.98 × 10 –3 mol C 2 H 2 mol −1 Co min −1 for Ni-MFU-4l-OH and Co-MFU-4l-OH, respectively, compared to their BBTA analogues. However, the Co-based MOFs, particularly Co 2 (OH) 2 -BBTA, exhibited greater selectivity (up to 19%) for the fully hydrogenated ethane product. Isosteric heat of adsorption (Q st ) measurements for ethylene and ethane revealed that the BBTA framework had stronger binding to the products than MFU-4l. Furthermore, these findings demonstrate that metal identity and coordination environment may modulate acetylene hydrogenation performance, leading to design principles for tuning LOHC hydrogenation catalysts.

catalysts↗

57 Fe nuclear resonance vibrational spectroscopic studies of tetranuclear iron clusters bearing terminal iron( III )–oxido/hydroxido moieties

57 Fe nuclear resonance vibrational spectroscopy (NRVS) has been applied to study a series of tetranuclear iron ([Fe 4 ]) clusters based on a multidentate ligand platform (L 3− ) anchored by a 1,3,5-triarylbenzene linker and pyrazolate or (tertbutylamino)pyrazolate ligand (PzNH t Bu − ). These clusters bear a terminal Fe(III)–O/OH moiety at the apical position and three additional iron centers forming the basal positions. The three basal irons are connected with the apical iron center via a μ 4 -oxido ligand. Detailed vibrational analysis via density functional theory calculations revealed that strong NRVS spectral features below 400 cm −1 can be used as an oxidation state marker for the overall [Fe 4 ] cluster core. The terminal Fe(III)–O/OH stretching frequencies, which were observed in the range of 500–700 cm −1 , can be strongly modulated (energy shifts of 20–40 cm −1 were observed) upon redox events at the three remote basal iron centers of the [Fe 4 ] cluster without the change of the terminal Fe(III) oxidation state and its coordination environment. Therefore, the current study provides a quantitative vibrational analysis of how the remote iron centers within the same iron cluster exert exquisite control of the chemical reactivities and thermodynamic properties of the specific iron site that is responsible for small molecule activation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isolating the Contributions of Specific Network Sites to the Diffuse Vibrational Spectrum of Interfacial Water with Isotopomer-Selective Spectroscopy of Cold Clusters

Decoding the structural information contained in the interfacial vibrational spectrum of water requires understanding how the spectral signatures of individual water molecules respond to their local hydrogen bonding environments. In this study, we isolated the contributions for the five classes of sites that differ according to the number of donor (D) and acceptor (A) hydrogen bonds that characterize each site. These patterns were measured by exploiting the unique properties of the water cluster cage structures formed in the gas phase upon hydration of a series of cations M+·(H2O)n (M = Li, Na, Cs, NH4, CH3NH3, H3O, and n = 5, 20-22). This selection of ions was chosen to systematically express the A, AD, AAD, ADD, and AADD hydrogen bonding motifs. The spectral signatures of each site were measured using two-color, IR-IR isotopomer-selective photofragmentation vibrational spectroscopy of the cryogenically cooled, mass selected cluster ions in which a single intact H2O is introduced without isotopic scrambling, an important advantage afforded by the cluster regime. The resulting patterns provide an unprecedented picture of the intrinsic line shapes and spectral complexities associated with excitation of the individual OH groups, as well as the correlation between the frequencies of the two OH groups on the same water molecule, as a function of network site. The properties of the surrounding water network that govern this frequency map are evaluated by dissecting electronic structure calculations that explore how changes in the nearby network structures, both within and beyond the first hydration shell, affect the local frequency of an OH oscillator. The qualitative trends are recovered with a simple model that correlates the OH frequency with the network-modulated local electron density in the center of the OH bond.

Yang, Nan↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

NASA Tech Briefs, January 2004

Topics covered include: Multisensor Instrument for Real-Time Biological Monitoring; Sensor for Monitoring Nanodevice-Fabrication Plasmas; Backed Bending Actuator; Compact Optoelectronic Compass; Micro Sun Sensor for Spacecraft; Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets; Finned-Ladder Slow-Wave Circuit for a TWT; Directional Radio-Frequency Identification Tag Reader; Integrated Solar-Energy-Harvesting and -Storage Device; Event-Driven Random-Access-Windowing CCD Imaging System; Stroboscope Controller for Imaging Helicopter Rotors; Software for Checking State-charts; Program Predicts Broadband Noise from a Turbofan Engine; Protocol for a Delay-Tolerant Data-Communication Network; Software Implements a Space-Mission File-Transfer Protocol; Making Carbon-Nanotube Arrays Using Block Copolymers: Part 2; Modular Rake of Pitot Probes; Preloading To Accelerate Slow-Crack-Growth Testing; Miniature Blimps for Surveillance and Collection of Samples; Hybrid Automotive Engine Using Ethanol-Burning Miller Cycle; Fabricating Blazed Diffraction Gratings by X-Ray Lithography; Freeze-Tolerant Condensers; The StarLight Space Interferometer; Champagne Heat Pump; Controllable Sonar Lenses and Prisms Based on ERFs; Measuring Gravitation Using Polarization Spectroscopy; Serial-Turbo-Trellis-Coded Modulation with Rate-1 Inner Code; Enhanced Software for Scheduling Space-Shuttle Processing; Bayesian-Augmented Identification of Stars in a Narrow View; Spacecraft Orbits for Earth/Mars-Lander Radio Relay; and Self-Inflatable/Self-Rigidizable Reflectarray Antenna.

Source record↗

New methodology for measuring electron density perturbations caused by plasma coherent modes using profile reflectometry: Magnitudes and radial profiles in DIII-D

New capabilities of fast-sweep frequency-modulated profile reflectometry are explored to measure electron density ne perturbation magnitudes and radial profiles due to plasma coherent modes in DIII-D. The first approach is based on the frequency analysis of phase perturbations associated with high frequency (~MHz) Alfvén eigenmodes (AEs). The measurement of ~5.5 MHz fast-ion-driven global Alfvén eigenmodes (GAEs) is demonstrated in a neutral beam-heated DIII-D plasma. The GAE induced a broad radial distribution of phase perturbations in the profile reflectometer data. Analysis of these data determined the effective cutoff location displacement and the estimated ne fluctuation profile. In the second approach, high resolution ne profiles are used directly to determine the radial structure of ne perturbations due to a neo-classical tearing mode. These new measurements broaden the application of profile reflectometry and advance the development of AE spectroscopy as a tool for non-invasive diagnosis of fast-ion-driven modes in DIII-D and burning plasmas such as ITER.

47 OTHER INSTRUMENTATION↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Electronic structure and lattice dynamics of 1⁢𝑇−VSe 2 : Origin of the three-dimensional charge density wave

To characterize in detail the charge density wave (CDW) transition of 1⁢𝑇−VSe 2 , its electronic structure and lattice dynamics are comprehensively studied by means of x-ray diffraction, muon spectroscopy, angle resolved photoemission (ARPES), diffuse and inelastic x-ray scattering, and state-of-the-art first-principles density functional theory calculations. Resonant elastic x-ray scattering does not show any resonant enhancement at either V or Se, indicating that the CDW peak at the 𝐾 edges describes a purely structural modulation of the electronic ordering. ARPES experiments identify (i) a pseudogap at 𝑇 > 𝑇⁢ CDW , which leads to a depletion of the density of states in the ML-M'L' plane at 𝑇 < 𝑇⁢ CDW , and (ii) anomalies in the electronic dispersion reflecting a sizable impact of phonons on it. A diffuse scattering precursor, characteristic of soft phonons, is observed at room temperature (RT) and leads to the full collapse of the low-energy phonon (𝜔 1 ) with propagation vector (0.25 0 −0.3) r.l.u. Here, we show that the frequency and linewidth of this mode are anisotropic in momentum space, reflecting the momentum dependence of the electron-phonon interaction (EPI), hence demonstrating that the origin of the CDW is, to a much larger extent, due to the momentum dependent EPI with a small contribution from nesting. The pressure dependence of the 𝜔 1 soft mode remains nearly constant up to 13 GPa at RT, with only a modest softening before the transition to the high-pressure monoclinic C2/m phase. The wide set of experimental data is well captured by our state-of-the art first-principles anharmonic calculations with the inclusion of van der Waals corrections in the exchange-correlation functional. The comprehensive description of the electronic and dynamical properties of VSe 2 reported here adds important pieces of information to the understanding of the electronic modulations in the family of transition-metal dichalcogenides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spin-energy entanglement of a time-focused neutron

Intraparticle entanglement of individual particles such as neutrons could enable another class of scattering probes that are sensitive to entanglement in quantum systems and materials. Here, in this work, we present experimental results demonstrating quantum contextuality as a result of entanglement between the spin and energy modes (i.e., degrees of freedom) of single neutrons in a beam using a pair of resonant radio-frequency neutron spin flippers in the modulated intensity with zero effort configuration. We verified the mode entanglement by measuring a Clauser-Horne-Shimony-Holt contextuality witness S defined in the spin and energy subsystems, observing a clear breach of the classical bound of |S| ≤ 2, obtaining S = 2.40 ± 0.02. These entangled beams could enable alternative approaches for directly probing dynamics and entanglement in quantum materials whose low-energy excitation scales match those of the incident entangled neutron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗