Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Removal of drift from frequency stability measurements

A method of estimating frequency drift rate and removing its effect from Allan variance plots is given. When tried on a test of hydrogen masers, the methods gives consistent results. An error in the previous Allan variance computation algorithm is corrected.

Greenhall, C. A.↗

A novel multistage estimation of the signal parameters of a possibly data-modulated sinusoid under very high dynamics

A novel multistage estimation scheme is presented for estimating the parameters of a received carrier signal possibly phase-modulated by unknown data, and experiencing very high Doppler, Doppler rate, etc. Such a situation arises, for example, in the case of Global Positioning Systems (GPS) where the signal parameters are directly related to the position, velocity, acceleration and jerk of the GPS receiver. In the proposed multistage scheme, the first stage estimator operates as a coarse estimator resulting in higher rms estimation errors but with a relatively small probability of the frequency estimation error exceeding one-half of the sampling frequency (an event termed cycle slip). The second state of the estimator operates on the error signal available from the first stage, refining the overall estimates, and in the process also reduces the number of cycle slips. The first stage algorithm is selected to be a modified least squares algorithm operating upon the differential signal model and referred to as differential least squares. This estimation stage provides relatively coarse estimates of the frequency and its derivatives. The second algorithm is simply an extended Kalman filter which also yields the estimate of the phase along with a more refined estimate of frequency as well. A major advantage of the proposed algorithm is a reduction in the threshold on received carrier power-to-noise power spectral density ratio as compared to the threshold achievable by either of these algorithms alone. In fact, it appears from the simulations that for the case of an unmodulated carrier, the proposed scheme achieves the same threshold as for an almost exact and computationally intensive implementation of the maximum likelihood estimator.

Kumar, Rajendra↗

Rapid estimation of bending frequencies of rotating beams

A procedure is presented in the form of charts which permits the rapid estimation of the natural bending frequencies of helicopter rotor blades, both rotating and nonrotating. Since the approach is based on Southwell's equation, an evaluation of the method with regard to such things as higher modes, blade offset, and variable mass and stiffness distributions is also given. The evaluation shows that when nonrotating beam bending modes are used, Southwell's equation yields reasonably accurate bending frequencies for rotating helicopter blades. Example comparisons of frequencies estimated using the charts with values given by the manufacturer for several actual blades show that the simplified procedure yields good practical results.

Robert T Yntema↗

Vibrational processing of a dynamic structural flight system: A multichannel spectral estimation approach

Dynamic testing of large flight vehicles (rockets) is not only complex, but also can be very costly. These flights are infrequent and can lead to disastrous effects if something were to fail during the flight. The development of sensors coupled to internal components offers a great challenge in reducing their size, yet still maintaining their precision. Sounding rockets provide both a viable and convenient alternative to the more costly vehicular flights. Some of the major objectives are to test various types of sensors for monitoring components of high interest as well as investigating real-time processing techniques. Signal processing presents an extreme challenge in this noisy multichannel environment. The estimation and tracking of modal frequencies from vibrating structures is an important set of features that can provide information about the components under test; therefore, high resolution multichannel spectral processing is required. Finally, the application of both single channel and multichannel techniques capable of producing reliable modal frequency estimates of a vibrating structure from uncertain accelerometer measurements is discussed.

42 ENGINEERING↗

Using Bayesian Methodology to Estimate Liquefied Natural Gas Leak Frequencies

This analysis provides estimates on the leak frequencies of nine components found in liquefied natural gas (LNG) facilities. Data was taken from a variety of sources, with 25 different data sets included in the analysis. A hierarchical Bayesian model was used that assumes that the log leak frequency follows a normal distribution and the logarithm of the mean of this normal distribution is a linear function of the logarithm of the fractional leak area. This type of model uses uninformed prior distributions that are updated with applicable data. Separate models are fit for each component listed. Five order-of-magnitude fractional leak areas are considered, based on the flow area of the component. Three types of supporting analyses were performed: sensitivity of the model to the data set used, sensitivity of the leak frequency estimates to differences in the model structure or prior distributions, and sufficiency of sample sized used for convergence. Recommended leak frequency distributions for all component types and leak sizes are given. These leak frequency predictions can be used for quantitative risk assessments in the future.

03 NATURAL GAS↗

Nonmagnetized Collisional Plasma Parameter Estimation From Two Frequency Signal Interrogation Attenuation

A nonmagnetized collisional plasma parameter estimator from two frequency signal interrogation attenuation is developed. The plasma parameters that are estimated are the plasma frequency, electron neutral momentum collision frequency, and the plasma thickness. The plasma frequency and electron neutral momentum collision frequency are considered uniform across the plasma thickness. The relative permittivity is defined, and the complex index of refraction is developed. Using this definition and applying the plasma frequency, electron neutral momentum collision frequency, the radial propagation frequency, and plasma thickness, an attenuation is determined for known cases. The development of the estimator is discussed. The estimator uses a performance index where the minimum difference between the plasma frequencies and electron neutral momentum collision frequencies is determined for the two signal interrogation frequencies under the constraint of the same plasma thickness. The estimator was developed in three stages which include iterative, sequential, and adaptive. The setups of the iterative, sequential, and adaptive approaches are discussed. The impact of the interrogation frequency and the estimator setup is investigated. The estimator in the three development stages is compared with known cases and the plasma parameter estimator performance is quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spread-Spectrum Carrier Estimation With Unknown Doppler Shift

We present a method for the frequency estimation of a BPSK modulated, spread-spectrum carrier with unknown Doppler shift. The approach relies on a classic periodogram in conjunction with a spectral matched filter. Simulation results indicate accurate carrier estimation with processing gains near 40. A DSP-based prototype has been implemented for real-time carrier estimation for use in New Mexico State University's proposal for NASA's Demand Assignment Multiple Access service.

DeLeon, Phillip L.↗

Interpolation as a means of shift selection for multilevel Monte Carlo with lattice displacements

The calculation of disconnected diagram contributions to physical signals is a computationally expensive task in Lattice QCD. To extract the physical signal, the trace of the inverse Lattice Dirac operator, a large sparse matrix, must be stochastically estimated. Because the variance of the stochastic estimator is typically large, variance reduction techniques must be employed. Multilevel Monte Carlo (MLMC) methods reduce the variance of the trace estimator by utilizing a telescoping sequence of estimators. Frequency Splitting is one such method that uses a sequence of inverses of shifted operators to estimate the trace of the inverse of the lattice Dirac operator, however there is no a priori way to select the shifts that minimize the cost of the multilevel trace estimation. We present a sampling and interpolation scheme that is able to predict the variances associated with Frequency Splitting under displacements of the underlying space time lattice. The interpolation scheme is able to predict the variances to high accuracy and therefore choose shifts that correspond to an approximate minimum of the cost for the trace estimation. We show that Frequency Splitting with the chosen shifts displays significant speedups over multigrid deflation

Whyte, Travis↗

Inverse scattering for an exterior Dirichlet problem

Scattering caused by a metallic cylinder in the field of a wire carrying a periodic current is studied, with a view to determining the location and shape of the cylinder in light of far field measurements between the cylinder and the wire. The associated direct problem is the exterior Dirichlet problem for the Helmholtz equation in two dimensions, and an improved low frequency estimate for its solution by integral equation methods is shown by inverse scattering calculations to be accurate to this estimate. The far field measurements are related to low frequency boundary integral equations whose solutions may be expressed in terms of a mapping function for the exterior of the unknown curve onto the exterior of a unit disk. The conformal transformation's Laurent expansion coefficients can be related to those of the far field, the first of which leads to the calculation of the distance between the source and the cylinder, while the other coefficients are determined by placing the source in a different location.

Hariharan, S. I.↗

Respiratory modulation of human autonomic rhythms

We studied the influence of three types of breathing [spontaneous, frequency controlled (0.25 Hz), and hyperventilation with 100% oxygen] and apnea on R-R interval, photoplethysmographic arterial pressure, and muscle sympathetic rhythms in nine healthy young adults. We integrated fast Fourier transform power spectra over low (0.05-0.15 Hz) and respiratory (0.15-0.3 Hz) frequencies; estimated vagal baroreceptor-cardiac reflex gain at low frequencies with cross-spectral techniques; and used partial coherence analysis to remove the influence of breathing from the R-R interval, systolic pressure, and muscle sympathetic nerve spectra. Coherence among signals varied as functions of both frequency and time. Partialization abolished the coherence among these signals at respiratory but not at low frequencies. The mode of breathing did not influence low-frequency oscillations, and they persisted during apnea. Our study documents the independence of low-frequency rhythms from respiratory activity and suggests that the close correlations that may exist among arterial pressures, R-R intervals, and muscle sympathetic nerve activity at respiratory frequencies result from the influence of respiration on these measures rather than from arterial baroreflex physiology. Most importantly, our results indicate that correlations among autonomic and hemodynamic rhythms vary over time and frequency, and, thus, are facultative rather than fixed.

Non-NASA Center↗

Optimizing shift selection in multilevel Monte Carlo for disconnected diagrams in lattice QCD

The calculation of disconnected diagram contributions to physical signals is a computationally expensive task in Lattice QCD. To extract the physical signal, the trace of the inverse Lattice Dirac operator, a large sparse matrix, must be stochastically estimated. Because the variance of the stochastic estimator is typically large, variance reduction techniques must be employed. Multilevel Monte Carlo (MLMC) methods reduce the variance of the trace estimator by utilizing a telescoping sequence of estimators. Frequency Splitting is one such method that uses a sequence of inverses of shifted operators to estimate the trace of the inverse lattice Dirac operator, however there is no a priori way to select the shifts that minimize the cost of the multilevel trace estimation. Here we present a sampling and interpolation scheme that is able to predict the variances associated with Frequency Splitting under displacements of the underlying space time lattice. The interpolation scheme is able to predict the variances to high accuracy and therefore chooses shifts that correspond to an approximate minimum of the cost for the trace estimation. We show that Frequency Splitting with the chosen shifts displays significant speedups over multigrid deflation, and that these shifts can be used for multiple configurations within the same ensemble with no penalty to performance.

97 MATHEMATICS AND COMPUTING↗

Kalman plus weights: a time scale algorithm

KPW is a time scale algorithm that combines Kalman filtering with the basic time scale equation (BTSE). A single Kalman filter that estimates all clocks simultaneously is used to generate the BTSE frequency estimates, while the BTSE weights are inversely proportional to the white FM variances of the clocks. Results from simulated clock ensembles are compared to previous simulation results from other algorithms.

time time scales stability Kalman filtering↗

Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections

Purpose: Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981–5005 (2013)]. Methods: A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11–0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. Results: For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors’ previous experimental measurements using source-based skull corrections O’Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285–1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood–brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Conclusions: Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography.

60 APPLIED LIFE SCIENCES↗

Inhibiting multiple mode vibration in controlled flexible systems

Prior research has led to the development of input command pre-shapers that can significantly reduce residual vibration. These shapers exhibit marked insensitivity to errors in natural frequency estimates and can be used to minimize vibration at more than one frequency. A method is outlined for the development of multiple mode input shapers. An examination is made of the results of shaper performance tests conducted on linear and non-linear computer models of MACE, an MIT/NASA experimental flexible structure.

Hyde, James M.↗

Using input command pre-shaping to suppress multiple mode vibration

Spacecraft, space-borne robotic systems, and manufacturing equipment often utilize lightweight materials and configurations that give rise to vibration problems. Prior research has led to the development of input command pre-shapers that can significantly reduce residual vibration. These shapers exhibit marked insensitivity to errors in natural frequency estimates and can be combined to minimize vibration at more than one frequency. This paper presents a method for the development of multiple mode input shapers which are simpler to implement than previous designs and produce smaller system response delays. The new technique involves the solution of a group of simultaneous non-linear impulse constraint equations. The resulting shapers were tested on a model of MACE, an MIT/NASA experimental flexible structure.

Hyde, James M.↗

Understanding drivers of oil and gas well integrity issues in the greater wattenberg area of Colorado

Well integrity is critically important to maintain to minimize the environmental impacts of oil and gas development and other subsurface energy operations. The Wattenberg Field of Colorado—a top producing field with >40,000 wells—has one of the most robust publicly reported well integrity programs in the country. Here, in this study, we analyzed annular pressure and annular-fluid geochemical test results collected from Wattenberg wells through the end of 2019 to characterize the frequency and spatial variability of integrity issues in the field and understand their drivers. Estimated frequencies of integrity issues among tested wells were 8.2-17.1% between 1955 and 2019 and 6.1-11.4% in 2019 alone. The frequency of integrity issues was nearly four times greater in wells located above the Longmont Wrench Fault Zone. Potential drivers of integrity issues were identified using ensemble decision tree models trained with a broad set of relevant information. Models show that well integrity issues are spatially clustered on regional and sub-regional scales and suggest the relatively high frequency of integrity issues observed is likely attributed to geologic factors. These findings are valuable for regulatory agencies and operators seeking to inform well integrity monitoring, plugging, and emissions reduction efforts and design future subsurface energy projects.

03 NATURAL GAS↗

Effects of oscillating shock impingement on the mixing of a gaseous jet in a Mach 3 airstream

Oscillating shocks of different frequencies were impinged on a 15 deg downstream angled, sonic helium jet injected into a Mach 3 airflow. The oscillating shocks were produced by the normal injection of a steady liquid jet from an opposing wall into the Mach 3 airflow. The freestream Reynolds number per centimeter was 500,000 producing a boundary layer 1.6 times the helium injector diameter in thickness. Vertical helium concentration profiles were taken at nine transverse stations at an axial station 90 helium jet diameters downstream. Helium concentration was measured using an aspirating hot film probe with an integral thermocouple. Oscillating shock frequencies of 60 kHz, 120 kHz, and 240 kHz were studied, compared with the estimated frequencies of 60 kHz of the largest eddies in the approach boundary layer. Visualization using nanoshadowgraph photographs, showed large turbulent structures in all cases. In addition, there were clear changes in eddy size with changing frequency visible on the nanoshadowgraphs. Impingement of the oscillating shock upstream of the helium jet had no measurable effect on the mixing. Impingement downstream of the helium injector produced measurable changes in the mixing achieved. Increasing the frequency of the oscillating shock decreased the maximum concentration and the penetration height of the maximum concentration. There were additional measurable effects on the area of a typical concentration contour with increased oscillation frequency.

Thomas, R. H.↗

HIGH DYNAMIC RANGE OBSERVATIONS OF SOLAR CORONAL TRANSIENTS AT LOW RADIO FREQUENCIES WITH A SPECTRO-CORRELATOR

A new antenna system with a digital spectro-correlator that provides high temporal, spectral, and amplitude resolutions has been commissioned at the Gauribidanur Observatory near Bangalore in India. Presently, it is used for observations of the solar coronal transients in the scarcely explored frequency range ≈30–15 MHz. The details of the antenna system, the associated receiver setup, and the initial observational results are reported. Some of the observed transients exhibited quasi-periodicity in their time profiles at discrete frequencies. Estimates of the associated magnetic field strength (B) indicate that B ≈ 0.06–1 G at a typical frequency such as 19.5 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗