Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Low-power multichannel ASIC for Gamma-ray Medical Imager

In this CRADA BNL agreed to revise the design and layout of a prototype low-noise multi-channel front-end ASIC for use in Digirad’s new generation of gamma cameras based on CsI-Si pixel sensors. The ASIC must provide low-noise charge amplification, photon-counting and amplitude/timing resolving capability, multiplexed readout. Starting from the first prototype developed in 2011 CRADA BNL-C-10-10 BNL agreed on the following modifications.

99 GENERAL AND MISCELLANEOUS↗

Moly 99 Reactor Case Study

Molybdenum-99 (Moly 99) is a critical raw material for Technetium (Tc) 99m, a radioactive isotope most widely used in nuclear medicine procedures. Moly 99 has a short half-life of about six hours, which means it cannot be stockpiled. When Moly 99 decays, it turns into Tc 99m, which has a half-life of 214,000 years. The photon energy emitted from the decay of Moly 99 is used in a variety of nuclear imaging technologies such as gamma cameras. Furthermore, radiopharmaceutical manufacturers use the photon energy emitted from the decay of Moly 99 to produce generators for hospitals, clinics, and radiopharmacies. Once Moly 99 decays to Tc 99m, it is used to make individual patient doses for a variety of diagnostic imaging procedures. The Moly 99 Reactor Design is a conceptual blueprint for Moly 99 production that does not use weapon-grade uranium; instead, the reactor has a target core of low-enriched uranium. The reactor design is small, reaching a foot-and-a-half in height and diameter and consumes less than two megawatts of power. The reactor's only purpose is for medical isotope production and with every fission, Moly 99 is produced.

07 ISOTOPE AND RADIATION SOURCES↗

Heart Imaging System

Johnson Space Flight Center's device to test astronauts' heart function in microgravity has led to the MultiWire Gamma Camera, which images heart conditions six times faster than conventional devices. Dr. Jeffrey Lacy, who developed the technology as a NASA researcher, later formed Proportional Technologies, Inc. to develop a commercially viable process that would enable use of Tantalum-178 (Ta-178), a radio-pharmaceutical. His company supplies the generator for the radioactive Ta-178 to Xenos Medical Systems, which markets the camera. Ta-178 can only be optimally imaged with the camera. Because the body is subjected to it for only nine minutes, the radiation dose is significantly reduced and the technique can be used more frequently. Ta-178 also enables the camera to be used on pediatric patients who are rarely studied with conventional isotopes because of the high radiation dosage.

Source record↗

Fabricating High-Resolution X-Ray Collimators

A process and method for fabricating multi-grid, high-resolution rotating modulation collimators for arcsecond and sub-arcsecond x-ray and gamma-ray imaging involves photochemical machining and precision stack lamination. The special fixturing and etching techniques that have been developed are used for the fabrication of multiple high-resolution grids on a single array substrate. This technology has application in solar and astrophysics and in a number of medical imaging applications including mammography, computed tomography (CT), single photon emission computed tomography (SPECT), and gamma cameras used in nuclear medicine. This collimator improvement can also be used in non-destructive testing, hydrodynamic weapons testing, and microbeam radiation therapy.

Appleby, Michael↗

Imaging method for monitoring delivery of high dose rate brachytherapy

A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A liquid xenon radioisotope camera.

A new type of gamma-ray camera is discussed that makes use of electron avalanches in liquid xenon and is currently under development. It is shown that such a radioisotope camera promises many advantages over any other existing gamma-ray cameras. Spatial resolution better than 1 mm and counting rates higher than one million C/sec are possible. An energy resolution of 11% FWHM has recently been achieved with a collimated Hg-203 source using a parallel-plate ionization chamber containing a Frisch grid.

Zaklad, H.↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

Hoover, R. B.↗

Gamma ray imager on the DIII-D tokamak

A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1–60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

JET next D-T campaign is presently scheduled for the year 2017. The main scientific objectives include the assessment of the isotopic effects on various plasma aspects: mainly on confinement, on the threshold to access the H mode and on ELM behaviour. From a technical point of view, the total yield of the entire D-T phase is expected to be 1.7 1021 neutrons, about a factor of six higher than the previous main D-T campaign on JET, DTE1. Therefore the radiation field will be quite relevant for next step devices, since the neutron flux at the first wall (∼10{sup 16} n/cm{sup 2}s), for example, will be comparable to the one in ITER behind the blanket. From a point of view of diagnostics developments, for many years JET diagnostics have been upgraded in order to provide adequate support for the scientific exploitation of a D-T campaign. The main efforts have concentrated on improving three main aspects of JET measuring capability: 1) the quality of the measurements of the electron and ion fluids to support the plasma physics programme 2) the diagnostic for the fusion products 3) diagnostic technologies for ITER. In terms of general diagnostic capability, compared to the previous DTE1, JET diagnostics have a much better spatial and temporal resolution of both the ion and electron fluid (about one order of magnitude improvement for each parameter). The consistency of the various independent measurements of the same parameters has also increased significantly; the three independent measurements of the electron temperature, for example, agree now within 5%. Moreover, solutions are being addressed to operate some cameras, both visible and IR, even during the full D-T phase to provide imaging of the plasma and the first wall. Various upgrades of neutral particle analysis are being considered, mainly to measure the isotopic composition. A new set of reflectometers is expected to provide valuable information about the changes in the turbulence with the different fuel mixtures. With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extra-light gamma-ray imager for safeguards and homeland security

Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

42 ENGINEERING↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of imaging to the atmospheric Cherenkov technique

Turver and Weekes proposed using a system of phototubes in the focal plane of a large reflector to give an air Cherenkov camera for gamma ray astronomy. Preliminary results with a 19 element camera have been reported previously. In 1983 the camera was increased to 37 pixels; it has now been routinely operated for two years. A brief physical description of the camera, its mode of operation, and the data reduction procedures are presented. The Monte Carlo simultations on which these are based on also reviewed.

Cawley, M. F.↗

Modulated Multiple Slit Camera for improved localization of gamma ray bursts

An instrument is described in which a cylindrical modulation collimator is added to one half of a Multiple Slit Camera (MSC) coded-aperture imaging system. The instrument provides gamma-ray burst positions from a single spacecraft that are as precise as the best positions from the long-baseline network of interplanetary spacecraft. The determination of fine positions is described, and the fine-position capability is shown to operate over about two-thirds of the MSC's nearly all-sky field of view. It is noted that the addition of the modulation collimator only slightly reduces the system's sensitivity and can improve the location precision for gamma-ray bursts and slower hard-X-ray transients to about 0.1 sq arcmin.

Gorenstein, P.↗