Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma ray detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SAS-2 High energy gamma-ray observations of the Vela pulsar

The second Small Astronomy Satellite high-energy (35 MeV) gamma-ray telescope detected pulsed gamma-ray emission at the radio period from PSR 0833-45, the Vela pulsar, as well as an unpulsed flux from the Vela region. The pulsed emission consists of two peaks, one following the radio peak by about 13 msec, and the other 0.4 period after the first. The luminosity of the pulsed emission above 100 MeV from Vela is about 0.1 that of the pulsar NP0532 in the Crab nebula, whereas the pulsed emission from Vela at optical wavelengths is less than 0.0004 that from the Crab. The relatively high intensity of the pulsed gamma-ray emission and the double peak structure, compared to the single pulse in the radio emission, suggests that the high energy gamma-ray pulsar emission may be produced under different conditions from those found at lower energies.

Thompson, D. J.↗

Simultaneous optical/gamma ray observations of GRB's

The photographic sky patrols of the Observatories Sonneberg (FRG), Ondrejov (CSFR), Odessa (Ukraine) are used to look for patrol plates which were exposed simultaneously with a gamma-ray burst (GRB) detected by gamma ray observations. The results for the first year of data are presented. For several GRB plates which contain the GRB location, and the exposure time of which contains the time of the GRB are presented. The results of the research for optical flashes on these simultaneous plates are discussed.

Kouveliotou, C.↗

Simultaneous optical/gamma-ray observations of GRBs

Details on the project to search for serendipitous time correlated optical photographic observations of Gamma Ray Bursters (GRB's) are presented. The ongoing photographic observations at nine observatories are used to look for plates which were exposed simultaneously with a gamma ray burst detected by the gamma ray instrument team (BATSE) and contain the burst position. The results for the first two years of the gamma ray instrument team operation are presented.

Greiner, J.↗

A new method for determining the Hubble constant from sub-TeV gamma-ray observations

The present uncertainty in the Hubble constant leaves unresolved questions regarding the age of the universe and related matters involving the amount and nature of the dark matter in the universe, consistency with the inflationary model of the universe, and the need for a cosmological constant. It is clear that a significantly precise determination of the Hubble constant by as many different methods as possible is crucial to our knowledge and understanding of the character of the universe. We propose here an entirely new method for determining the Hubble constant, based on measuring the extinction of high-energy gamma-rays emitted by detectable gamma-ray emitting blazars at various redshifts.

Salamon, M. H.↗

GLAST GRB Observations and Capabilities

Gamma Ray Large Area Space Telescope (GLAST) is schedule to launch on May 16, 2008. GLAST consists of the Large Area Telescope (LAT), which will detect gamma rays above 20 MeV with unprecedented sensitivity, and the GLAST Burst Monitor (GBM), which will provide all-sky monitoring of GRBS in the 10 kev to 30 MeV range. Predicted GRB capabilities of GLAST will be described. The on-orbit performance of the instruments and preliminary GRB observations will be presented.

Meegan, Charles↗

Gamma-Ray Imaging for Explosives Detection

We describe a gamma-ray imaging camera (GIC) for active interrogation of explosives being developed by NASA/GSFC and NSWCICarderock. The GIC is based on the Three-dimensional Track Imager (3-DTI) technology developed at GSFC for gamma-ray astrophysics. The 3-DTI, a large volume time-projection chamber, provides accurate, approx.0.4 mm resolution, 3-D tracking of charged particles. The incident direction of gamma rays, E, > 6 MeV, are reconstructed from the momenta and energies of the electron-positron pair resulting from interactions in the 3-DTI volume. The optimization of the 3-DTI technology for this specific application and the performance of the GIC from laboratory tests is presented.

deNolfo, G. A.↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionizing Organic Compound Based Nanocomposites for Efficient Gamma-Ray Sensor

Thin film and nanocrystalline materials of oxides have been very attractive choice as low cost option for gamma-ray detection and have shown great promise. Our studies on pure oxide films indicated that thickness and microstructure have pronounced effect on sensitivity. Since the interaction of gamma-ray with composites involves all three interaction processes; photoelectric effect, Compton scattering, and pair production, composites containing ionic organics have better chance for enhancing sensitivity. In the composites of ionizing organics oxidation effect of unusual oxides changes much faster and hence increases the sensitivity of radiation. In this study, we have used nickel oxide and titanium oxide in ionic organics to develop composite materials for low energy gamma-ray sensing. We prepared composites containing ethylene carbonate and evaluated the effect of commercial Cs-137 radiation source by studying current-voltage relationship at several frequencies. Radiated samples showed higher resistivity compared to as prepared composites.

Singh, N. B.↗

Burst detection capability of the Mars Observer gamma-ray spectrometer

This paper describes the gamma-ray burst detection capability of the gamma-ray spectrometer on board the Mars Observer spacecraft. The instrument is designed to respond to significant bursts by suspending its observation of the Martian surface in favor of optimizing the collection of pre-burst, burst, and post-burst data. The results are expected to contribute to our understanding of gamma-ray bursts through a high energy resolution search for line emission, by the examination of spectral shapes and by comprising one leg of an arrival time network to determine the direction of origin.

Metzger, Albert E.↗

Recent Results on SNRs and PWNe from the Fermi Large Area Telescope

Topics include: Fermi LAT Collaboration groups; galactic results from LAT; a GeV, wide-field instrument; the 1FGL catalog, the Fermi LAT 1FGL source catalog, unidentified gamma-ray sources; variability in 1FGL sources; curvature in 1FGL sources; spectral-variability classification; pulsars and their wind nebulae; gamma-ray pulsars and MSPs; GeV PWN search; Crab pulsar and nebula; Vela X nebular of Vela pulsar; MSH 15-52; supernova remnants, resolved GeV sources, galactic transients, LAT unassociated transient detections; gamma rays from a nova; V407 Cyngi - a symbiotic nova; V407 Cygni: a variable star; and March 11 - a nova. Summary slides include pulsars everywhere, blazars, LAT as an electron detector, cosmic ray spectrum, the Large Area Telescope, the Fermi Observatory, LAT sensitivity with time, candidate gamma-ray events, on-orbit energy calibration and rate, a 1 year sky map, LAT automated science processing, reported GeV flares, early activity and spectacular flare, gamma-ray transients near the galactic plane , two early unassociated transients, counter part search - Fermi J0910-5404; counterpart search 3EG J0903-3531, and a new LAT transient - J1057-6027.

Hays, Elizabeth↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Egret detection of the blazar PKS 0420-014

During its full-sky survey, the Energetic Gamma Ray Experiment Telescope (EGRET) high-energy instrument aboard the Compton Gamma-Ray Observatory detected gamma-ray emission in the energy range above 30 MeV from a source identified as the blazar PKS 0420-014. This object was observed during two separate viewing periods in 1992 February/March and May/June. An intensity decrease above 100 MeV of a factor of at least 1.5 from a maximum of (5.0 +/- 1.4) x 10(exp -7) photons 1 sq cm/s was observed during that time interval indicating extensive variability. The photon spectrum in the range between 30 and 10,000 MeV at the time of the maximum intensity is well represented by a power law with an exponent of -1.9 +/- 0.3. Some similarities with other EGRET detected blazars are briefly discussed.

Radecke, H.-D.↗

Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles

Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum sensing using a qubit for the detection of ionizing radiation

Quantum sensing utilizes the inherent sensitivity of a quantum system to external stimuli. Our goal is to leverage this sensitivity to develop a quantum sensor designed for the detection of ionizing radiation. Here we report on the design, fabrication, and measurement of a new quantum device for hard x-ray and gamma-ray detection. Our quantum device is based on a superconducting quantum bit (qubit) with superconducting tunnel junctions as the core device elements. We describe our experimental investigation directed toward the detection metrics of energy resolution, dynamic range, and active area. In contrast to existing superconducting detectors, the active area per qubit may be much larger than the physical area of the tunnel junctions or the physical area of the qubit device, due to the sensitivity of quantum coherence to ionizing radiation deposition within a radius on the millimeter or centimeter scale. Furthermore, our experimental design enables an ionizing radiation source at room temperature to be detected by our quantum sensor at low temperature.

qubit↗

Gamma rays and supernova explosions

The detection of gamma rays from supernovae will provide interesting tests of current theory. Some current ideas on the expected gamma ray flux, as modified by recent theoretical results are reviewed.

Arnett, W. D.↗

An experimental assessment of the imaging quality of the low energy gamma-ray telescope ZEBRA

One gamma-ray detection plane of the ZEBRA telescope, consisting of nine position sensitive scintillation crystal bars designed to operate over the spectral range 0.2 to 10 MeV, has been constructed in the laboratory. A series of experimental images has been generated using a scaled down flight pattern mask in conjunction with a diverging gamma-ray beam. Point and extended sources have been imaged in order to assess quantitatively the performance of the system.

Butler, R. C.↗