Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sample analysis systems and methods of use thereof

The invention generally relates to sample analysis systems and methods of use thereof. In certain aspects, the invention provides a system for analyzing a sample that includes an ion generator configured to generate ions from a sample. The system additionally includes an ion separator configured to separate at or above atmospheric pressure the ions received from the ion generator without use of laminar flowing gas, and a detector that receives and detects the separated ions.

42 ENGINEERING↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A High Precision Measurement of the Proton Charge Radius at JLab

The elastic electron-proton (e-p) scattering and the spectroscopy of hydrogen atoms are the two traditional methods to determine the proton charge radius (r p ). In 2010, a new method using muonic hydrogen (µH) 1 spectroscopy reported a r p result that was nearly ten times more precise but significantly smaller than the values from the compilation of all previous r p measurements. This discrepancy is often referred to as the "proton charge radius puzzle". In order to investigate the puzzle, the PRad experiment (E12-11-106) was first proposed in 2011 and performed in 2016 in Hall B at the Thomas Jefferson National Accelerator Facility, with both 1.1 and 2.2 GeV electron beams. The experiment measured the e-p elastic scattering cross sections in an unprecedented low values of momentum transfer squared region (Q 2 = 2.1× 10 -4 -0.06 (GeV/c) 2 ), with a sub-percent precision. The PRad experiment utilized a calorimetric method that was magnetic-spectrometer-free. Its detector setup included a large acceptance and high resolution calorimeter (HyCal), and two large-area, high spatial-resolution Gas Electron Multiplier (GEM) detectors. To have a better control over the systematic uncertainties, the absolute e-p elastic scattering cross section was normalized to that of the well-known Møller scattering process, which was measured simultaneously during the experiment. For each beam energy, all data with different Q 2 were collected simultaneously with the same detector setup, therefore sharing the same integrated luminosity. The windowless H 2 gas-flow target utilized in the experiment largely removed a typical background source, the target cell windows. The proton charge radius was determined as r p = 0.831±0.007 stat. ±0.012 p fm, which is smaller than the average r p from previous e-p elastic scattering experiments, but in agreement with the µH spectroscopic results within the experimental uncertainties.

Source record↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

Initial tests of Accelerator Mass Spectrometry with the Argonne Gas-Filled Analyzer and the commissioning of the MONICA detector

As the scope of Accelerator Mass Spectrometry (AMS) expands, there is an increased need to extend the capability of isobaric separation to the medium-heavy mass region. Existing AMS facilities are limited in their ability to separate radioactive nuclei in the A = 100–200 range of interest from their neighboring stable isobars, as such measurements require higher energies than available in most facilities. ATLAS is one of the highest energy system used for AMS based experiments and has enabled isobaric discrimination for medium to heavy nuclides, notably via the Gas-Filled Magnet technique. Further, a preparatory experiment performed in November, 2019, successfully demonstrated isobaric separation of 92 Zr- 92 Mo using the Argonne Gas-Filled Analyzer (AGFA) with high magnetic rigidity. Since that time, MONICA, an eight-anode ionization chamber that measures both energy loss and position with two sets of split anodes, has been developed to aid in AMS experiments at AGFA and has undergone four commissioning runs at the Nuclear Science Laboratory at the University of Notre Dame utilizing Si, Fe/Ni, and Mn beams. This report presents the AGFA AMS run (November 2019) and the subsequent commissioning runs of the MONICA detector, including preliminary measurements on the long-lived isotopes 39 Ar (268 y) and for the first time on 42 Ar (33 y).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Kariya ( Hildegardia barteri (Mast.) Kosterm) Seed Oil Fatty Acid Methyl Ester Prepared from Basic Catalytic Transesterification

The rising global energy demand, alongside concerns regarding environmental deterioration due to the use of fossil fuels, has spurred extensive investigation into renewable energy alternatives. Biomass-derived biodiesel, especially from lesser-known oil sources, emerges as a promising option. This research focuses on analyzing the fatty acid methyl esters (FAMEs) derived from Kariya (Hildegardia barteri (Mast.) Kosterm) seed oil through basic catalytic transesterification using gas chromatography–flame ionization detector (GC–FID) analysis, assessing its potential as a biodiesel feedstock. Oil extraction from Kariya seeds was carried out using three solvents (n-hexane, ethanol, and a 1:1 blend of hexane and ethanol), followed by transesterification with methanol. Gas chromatography–mass spectrometry (GC–MS) and GC–FID analyses were utilized to identify and quantify FAMEs in the resulting biodiesel. The results revealed various FAMEs, including methyl myristate, methyl palmitate, methyl stearate, methyl oleate, methyl linoleate, and methyl linolenate. Significant differences in FAME composition were observed among the samples, with hexane–ethanol Kariya oil biodiesel (HE-KOB) showing the highest FAME content (76.1%). This combination of solvents exhibited synergistic effects on the composition of HE-KOB, suggesting potential optimization strategies for biodiesel production. Fourier transform infrared spectroscopy (FTIR) provided additional insights into the molecular composition of the biodiesel samples, confirming their biodiesel nature through the identified functional groups such as methyl, methylene, hydrocarbon, ester, aldehyde, and alkene. Thermogravimetric analysis (TGA) for thermal decomposition also gave an insight into FAME composition and its contribution to the degree of conversion of biodiesel to energy. These findings highlight the feasibility of utilizing Kariya seed oil as a biodiesel feedstock, emphasizing the importance of solvent selection and transesterification conditions in optimizing FAME yield and composition. This research contributes to the exploration of underutilized oil sources for sustainable biodiesel production, aligning with the global shift towards cleaner and renewable energy sources.

09 BIOMASS FUELS↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Measurement of the free neutron lifetime in a magneto-gravitational trap with in situ detection

Here, in this study, we publish three years of data from the UCNτ experiment performed at the Los Alamos Ultracold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We previously reported a value from our 2017–2018 data for the neutron lifetime of 877.75 ± 0.28 (statistical) +0.22–0.16 (systematic) s. We have collected an additional three years of data reported here for the first time. When all the data from UCNτ are averaged for 2017, 2018, 2020, 2021, and 2022, we report an updated value for the lifetime of 877.83 ± 0.22 (statistical)+0.20–0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on residual gas, and employed four different UCN detector geometries both to reduce the correction required for rate dependence and to explore potential contributions due to phase space evolution.

Cabibbo-Kobayashi-Maskawa matrix↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗