Thin-film temperature sensors for gas turbine engines Problems and prospects

The erosion and corrosion of thermocouples used to measure the temperature in turbine engines are studied. Structural and metallurgical interactions and instabilities at thermocouple interfaces are analyzed. Consideration is given to the adhesion, dielectric quality, surface topography, and hardness of the thermal oxides; it is observed that the structural and thermoelectric stability of thin-film thermocouple elements depends on adhesion, surface topography, and dielectric strength. The electrical conductivity and impurity content of the oxide scale are evaluated. Methods for improving the adhesion of thermocouples on the alumina surfaces are described. Compositional inhomogeneities in the sensors and contamination of the thermocouple elements are examined. The fabrication of the thermocouples is discussed. It is noted that Al2O3 and Si3N4 are useful for developing stable thermocouple elements on the surface of the blades and vanes.

Budhani, R. C.↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

A research on integrated-circuit sensors for gas chromatography

Fabrication of a miniature gas chromatograph column using integrated circuit technology was studied and found to be feasible. A bonding problem of forming a strong, gas tight seal between two wafers of silicon has prevented the completion of the column design. Continuing research using tin or a chromium-gold bond promises to overcome the problems of using the proposed gold-eutectic bond. Specifications for the miniature gas chromatograph column are: a spiral capillary column of semi-circular cross section, 30 micron radius, and a total length of 6.9 meters etched into a silicon structure 50 mm in diameter and 0.625 mm thick.

Source record↗

Improved 02/H2 Gas Mixture Sensor

Monitor of mixture concentrations uses catalyzed and uncatalyzed temperature probe. Sensor includes Pt-catalyzed temperature probe mounted in line with similar uncatalyzed temperature probe. Use of common temperature probes and standard, flareless, high-pressure tubefittings resulted in design conductive to installation in almost any system. Suitable for use in regenerative fuel cells, life-support systems, and other closed systems.

Moulthrop, L. C.↗

Predictive sensor method and apparatus

A predictive algorithm is used to determine, in near real time, the steady state response of a slow responding sensor such as hydrogen gas sensor of the type which produces an output current proportional to the partial pressure of the hydrogen present. A microprocessor connected to the sensor samples the sensor output at small regular time intervals and predicts the steady state response of the sensor in response to a perturbation in the parameter being sensed, based on the beginning and end samples of the sensor output for the current sample time interval.

Nail, William L.↗

Real-Time Optical Fuel-to-Air Ratio Sensor for Gas Turbine Combustors

The measurement of the temporal distribution of fuel in gas turbine combustors is important in considering pollution, combustion efficiency and combustor dynamics and acoustics. Much of the previous work in measuring fuel distributions in gas turbine combustors has focused on the spatial aspect of the distribution. The temporal aspect however, has often been overlooked, even though it is just as important. In part, this is due to the challenges of applying real-time diagnostic techniques in a high pressure and high temperature environment. A simple and low-cost instrument that non-intrusively measures the real-time fuel-to-air ratio (FAR) in a gas turbine combustor has been developed. The device uses a dual wavelength laser absorption technique to measure the concentration of most hydrocarbon fuels such as jet fuel, methane, propane, etc. The device can be configured to use fiber optics to measure the local FAR inside a high pressure test rig without the need for windows. Alternatively, the device can readily be used in test rigs that have existing windows without modifications. An initial application of this instrument was to obtain time-resolved measurements of the FAR in the premixer of a lean premixed prevaporized (LPP) combustor at inlet air pressures and temperatures as high as 17 atm at 800 K, with liquid JP-8 as the fuel. Results will be presented that quantitatively show the transient nature of the local FAR inside a LPP gas turbine combustor at actual operating conditions. The high speed (kHz) time resolution of this device, combined with a rugged fiber optic delivery system, should enable the realization of a flight capable active-feedback and control system for the abatement of noise and pollutant emissions in the future. Other applications that require an in-situ and time-resolved measurement of fuel vapor concentrations should also find this device to be of use.

Nguyen, Quang-Viet↗

Alpha-Particle Gas-Pressure Sensor

An approximate model was developed to establish design curves for the saturation region and a more complete model developed to characterize the current-voltage curves for an alpha-particle pressure sensor. A simple two-parameter current-voltage expression was developed to describe the dependence of the ion current on pressure. The parameters are the saturation-current pressure coefficient and mu/D, the ion mobility/diffusion coefficient. The sensor is useful in the pressure range between 0.1 and 1000 mb using a 1 - mu Ci(241) Am source. Experimental results, taken between 1 and up to 200 mb, show the sensor operates with an anode voltage of 5 V and a sensitivity of 20 fA/mb in nitrogen.

Buehler, M. C.↗

Fiber optic sensors for gas turbine control

An apparatus for detecting flashback occurrences in a premixed combustor system having at least one fuel nozzle includes at least one photodetector and at least one fiber optic element coupled between the at least one photodetector and a test region of the combustor system wherein a respective flame of the fuel nozzle is not present under normal operating conditions. A signal processor monitors a signal of the photodetector. The fiber optic element can include at least one optical fiber positioned within a protective tube. The fiber optic element can include two fiber optic elements coupled to the test region. The optical fiber and the protective tube can have lengths sufficient to situate the photodetector outside of an engine compartment. A plurality of fuel nozzles and a plurality of fiber optic elements can be used with the fiber optic elements being coupled to respective fuel nozzles and either to the photodetector or, wherein a plurality of photodetectors are used, to respective ones of the plurality of photodetectors. The signal processor can include a digital signal processor.

Shu, Emily Yixie↗

Fiber optic sensors for gas turbine control

An apparatus for detecting flashback occurrences in a premixed combustor system having at least one fuel nozzle includes at least one photodetector and at least one fiber optic element coupled between the at least one photodetector and a test region of the combustor system wherein a respective flame of the fuel nozzle is not present under normal operating conditions. A signal processor monitors a signal of the photodetector. The fiber optic element can include at least one optical fiber positioned within a protective tube. The fiber optic element can include two fiber optic elements coupled to the test region. The optical fiber and the protective tube can have lengths sufficient to situate the photodetector outside of an engine compartment. A plurality of fuel nozzles and a plurality of fiber optic elements can be used with the fiber optic elements being coupled to respective fuel nozzles and either to the photodetector or, wherein a plurality of photodetectors are used, to respective ones of the plurality of photodetectors. The signal processor can include a digital signal processor.

Shu, Emily Yixie↗

Fiber optic sensors for gas turbine control

An apparatus for detecting flashback occurrences in a premixed combustor system having at least one fuel nozzle includes at least one photodetector and at least one fiber optic element coupled between the at least one photodetector and a test region of the combustor system wherein a respective flame of the fuel nozzle is not present under normal operating conditions. A signal processor monitors a signal of the photodetector. The fiber optic element can include at least one optical fiber positioned within a protective tube. The fiber optic element can include two fiber optic elements coupled to the test region. The optical fiber and the protective tube can have lengths sufficient to situate the photodetector outside of an engine compartment. A plurality of fuel nozzles and a plurality of fiber optic elements can be used with the fiber optic elements being coupled to respective fuel nozzles and either to the photodetector or, wherein a plurality of photodetectors are used, to respective ones of the plurality of photodetectors. The signal processor can include a digital signal processor.

Shu, Emily Yixie↗

Optical multi-species gas monitoring sensor and system

The system includes at least one light source generating light energy having a corresponding wavelength. The system's sensor is based on an optical interferometer that receives light energy from each light source. The interferometer includes a free-space optical path disposed in an environment of interest. The system's sensor includes an optical device disposed in the optical path that causes light energy of a first selected wavelength to continue traversing the optical path whereas light energy of at least one second selected wavelength is directed away from the optical path. The interferometer generates an interference between the light energy of the first selected wavelength so-traversing the optical path with the light energy at the corresponding wavelength incident on the optical interferometer. A first optical detector detects the interference. At least one second detector detects the light energy at the at least one second selected wavelength directed away from the optical path.

Polzin, Kurt A.↗

Alpha-Particle Gas-Pressure Sensor

An approximate model was developed to establish design curves for the saturation region and a more complete model developed to characterize the current-voltage curves for an alpha-particle pressure sensor.

alpha-particle↗

Aircraft instrumentation system for the remote sensing of carbon monoxide

A light twin-engine aircraft has been instrumented with a carbon monoxide remote gas sensor system and test flown over the Southern Lake Michigan basin during August, 1976. The remote sensor is based on the gas filter correlation technique. The radiance levels from the sensor along with the data on the surface temperature, air temperature, dewpoint, and altitude were digitized and recorded on seven-track magnetic tape. Air samples were collected at various altitudes over selected sites for later analysis of carbon monoxide concentration and comparison with the inferred concentration from the remote sensor. The values of carbon monoxide obtained from the air samples and the values inferred from the remote sensor for data collected over water are in good agreement.

Beck, S. M.↗

Acoustic composition sensor for cryogenic gas mixtures

An acoustic sensor useful for the determination of the composition of a gaseous binary mixture in cryogenic liquid spills has been characterized. One version of the instrument traps a known mixture of helium and nitrogen at ambient temperature in a tube which is interrogated by sonic pulses to determine the speed of sound and hence the composition. Experimental data shows that this sensor is quite accurate. The second version uses two unconfined microphones which sense sound pulses. Experimental data acquired during mixing when liquid nitrogen is poured into a vessel of gaseous helium is presented. Data during transient cooling of the tubular sensor containing nitrogen when the sensor is dipped into liquid nitrogen and during transient warm-up when the sensor is withdrawn are also presented. This sensor is being developed for use in the mixing of liquid cryogens with gas evolution in the simulation of liquid hydrogen/liquid oxygen explosion hazards.

Shakkottai, P.↗

Redesigned Gas Mass Flow Sensors for Space Shuttle Pressure Control System and Fuel Cell System

A program was conducted to determine if a state of the art micro-machined silicon solid state flow sensor could be used to replace the existing space shuttle orbiter flow sensors. The rather aggressive goal was to obtain a new sensor which would also be a multi-gas sensor and operate over a much wider flow range and with a higher degree of accuracy than the existing sensors. Two types of sensors were tested. The first type was a venturi throat design and the second was a bypass design. The accuracy of venturi design was found to be marginally acceptable. The bypass sensor was much better although it still did not fully reach the accuracy goal. Two main problems were identified which would require further work.

Source record↗