Search NASA⌕ Search

SEARCH · Search NASA

Results for “Glovebox”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Specimen Size Artifacts Associated with a Glovebox Deployable Laser Flash Diffusivity Measurement System

To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary results from three USML-1 Glovebox experiments

Three simple experiments, namely, Marangoni convection in closed containers (MCCC), fiber pulling in microgravity, and stability of a double float zone are described which were conducted during the U.S. Microgravity Laboratory mission (USML) in July 1992. Results show that, in the MCCC experiment, there was no evidence of partial wetting between the liquid and the walls either in the wetting or nonwetting configuration. In the nonwetting system, the void formed a hemispherical bubble that remained pinned to the walls with considerable contact line resistance. Significant differences were observed in the ability to pull liquid strings in low gravity in those materials which readily form liquid strands in normal gravity and do not necessarily form strands in reduced gravity. The double float zone configuration appeared to be quite stable in both cylindrical and sheet form.

Naumann, Robert J.↗

USML-1 microgravity glovebox experiment no. 1 Passive Accelerometer System

The passive accelerometer system (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The accelerometer can be used when the spacecraft continuously rotates during the orbit such that some line of reference in the craft always points along the vector connecting the earth's mass center with the spacecraft mass center. PAS was used successfully on the first United States Microgravity Laboratory (USML-1).

Alexander, J. Iwan D.↗

Slide Conveying of Granular Materials-Thinking Out of the Glovebox

The vibratory conveyor, routinely employed for normal-gravity transport of granular materials, usually consists of a continuous open trough vibrated sinusoidally to induce axial movement of a granular material. Motivated in part by a hypothetical application in zero gravity, we propose a novel modification of the vibratory conveyor based on a closed 2d trough operating in a "slide-conveying" mode, with the granular mass remaining permanently in contact with the trough walls. We present a detailed analysis of the mechanics of transport, based on a rigid-slab model for the granular mass with frictional (Coulomb) slip at the upper and lower walls. The form of the vibration cycle plays a crucial role, and the optimal conveying cycle is not the commonly assumed rectilinear sinusoidal motion. The conveying efficiency for the novel slide conveyor will be presented for several simple vibration cycles, including one believed to represent the theoretical optimum.

Goddard, J. D.↗

Pore Formation and Mobility (PFMI): An International Space Station Glovebox Investigation

Porosity in the form of "bubbles and pipes" can occur during controlled directional solidification processing of metal alloys. It is detrimental to material properties and precludes obtaining meaningful scientific results. On Earth, density differences allow an initiated bubble can rise through the liquid and "pop" at the surface resulting in a sound casting. This is not likely to occur in a microgravity environment and, unfortunately, a number of experiments conducted in microgravity have suffered from porosity effects. The current investigation is a systematic effort towards understanding porosity formation and mobility during controlled directional solidification in a microgravity environment. This will be investigated by utilizing a transparent material, succinonitrile (SCN), in conjunction with a translating temperature gradient stage so that direct observation and recording of pore generation and mobility can be made. The talk will cover the porosity problem, the details of the proposed experiments and the experimental hardware, and the expectations from the microgravity experiments.

Grugel, R. N.↗

Nucleation of Crystals From Solution in Microgravity (USML-1 Glovebox (GBX) Investigation)

A new method for initiating nucleation from solutions in microgravity which avoids nucleation on container walls and other surfaces is described. This method consists of injecting a small quantity of highly concentrated, heated solution into the interior of a lightly supersaturated, cooler host gowth solution. It was tested successfully on USML-I, producing a large number of LAP crystals whose longest dimension averaged 1 mm.

Kroes, Roger L.↗

Results from On-Board CSA-CP and CDM Sensor Readings During the Burning and Suppression of Solids II (BASS-II) Experiment in the Microgravity Science Glovebox (MSG)

For the first time on ISS, BASS-II utilized MSG working volume dilution with gaseous nitrogen (N2). We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced oxygen concentration in the working volume for each test. We calibrated the model with CSA-CP oxygen readings offset using the Mass Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient oxygen level, to our test matrices. The main variables tested in BASS-II were ambient oxygen concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS-II also utilized the on-board CSA-CP for oxygen and carbon monoxide readings, and the CDM for carbon dioxide readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The oxygen and carbon dioxide readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. Lastly, we calculated the heat release rates during each test from the oxygen consumption and burn times, using the constant 13.1 kJ of heat released per gram of oxygen consumed. The results showed that the majority of the tests had heat release rates well below 100 Watts.

combustion products↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division’s Systems Test Branch at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), and Infrared (IR) lamps. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Kaixin Cui↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater plates. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA) suits↗