Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulating the Effects of Stellarator Geometry on Gyrokinetic Drift-Wave Turbulence

Nuclear fusion is a clean, safe form of energy with abundant fuel. In magnetic fusion energy (MFE) experiments, the plasma fuel is confined by magnetic fields at very high temperatures and densities. One fusion reactor design is the non-axisymmetric, torus-shaped stellarator. Its fully-3D fields have advantages over the simpler, better-understood axisymmetric tokamak, including the ability to optimize magnetic configurations for desired properties, such as lower transport (longer confinement time). Turbulence in the plasma can break MFE confinement. While turbulent transport is known to cause a significant amount of heat loss in tokamaks, it is a new area of research in stellarators. Gyrokinetics is a good mathematical model of the drift-wave instabilities that cause turbulence. Multiple gyrokinetic turbulence codes that had great success comparing to tokamak experiments are being converted for use with stellarator geometry. This thesis describes such adaptations of the gyrokinetic turbulence code, GS2. Herein a new computational grid generator and upgrades to GS2 itself are described, tested, and benchmarked against three other gyrokinetic codes. Using GS2, detailed linear studies using the National Compact Stellarator Experiment (NCSX) geometry were conducted. The first compares stability in two equilibria with different beta=(plasma pressure)/(magnetic pressure). Overall, the higher beta case was more stable than the lower beta case. As high beta is important for MFE experiments, this is encouraging. The second compares NCSX linear stability to a tokamak case. NCSX was more stable with a 20% higher critical temperature gradient normalized by the minor radius, suggesting that the fusion power might be enhanced by about 50%. In addition, the first nonlinear, non-axisymmetric GS2 simulations are presented. Finally, linear stability of two locations in a W7-AS plasma were compared. The experimentally-measured parameters used were from a W7-AS shot in which measured heat fluxes match neoclassical theory predictions at inner radii, but are too large for neoclassical predictions at outer radii. Results from GS2 linear simulations show that the outer location has higher gyrokinetic instability growth rates than at the inner one. Mixing-length estimates of the heat flux are within a factor of 3 of the experimental measurements, indicating that gyrokinetic turbulence may be responsible for the higher transport measured by the experiment in the outer regions. Future nonlinear simulations can explore this question in more detail.

Gyrokinetics↗

KIVA-3V release 2

KIVA3VRELEASE2 is a computer program for the numerical calculation of transient, two and three-dimensional, chemically reactive flows with sprays. It is a newer version of the earlier KIVA3 (1993) that has now been extended to model vertical of canted valves in the cylinder head of a gasoline or diesel engine. KIVA3, in turn, was based on the earlier KIVA2 (1989) and uses the same numerical solution procedure and solves the same sort of equations. KIVA3VRELEASE2 uses a block-structured mesh with connectivity defined through indirect addressing. The departure from a single rectangular structure in logical space allows complex geometries to be modeled with significantly greater efficiency because large regions of deactivated cells are no longer necessary. Cell-face boundary conditions permit greater flexibility and simplification in the application of boundary conditions. KIVA3VRELEASE2 contains a number of significant changes. New features enhance the robustness, efficiency, and usefullness of the overall program for engine modeling. Automatic restart of the cycle with a reduced timestep in case of iteration limit or temperature overflow will reduce code crashes. A new option provides automatic deactivation of a port region when it is closed from the cylinder and reactivation when it communicates with the cylinder. Corrections in the code improve accuracy; extensions to the particle-based liquid wall film model makes the model more complete and a spli injection option has been added. A new subroutine monitors the liquid and gaseous fuel phases and energy balance data and emissions are monitored and printed. New features have been added to the grid generator K3PREP and the graphics post processor, K3POST.

Carrington, David↗

WBS 2.2.1.402 - Wave-SPARC: Systematic Process & Analysis for Reaching Commercialization

Wave-SPARC is empowering the marine energy community with the tools necessary to achieve a significant improvement in techno-economic performance of wave generated grid power. A detailed systems engineering approach simultaneously balances around 100 cost and performance drivers (functional requirements and capabilities) of wave energy converters (WECs). Publicly accessible technology innovation and assessment methods and tools (new to the wave energy sector) have been delivered. They guide technology development trajectories to successful outcomes in less time, at less overall cost, and with less encountered risk. Through the use of these methods and tools along with proven structured inventive techniques the project continues to deliver high potential novel wave energy technology concepts for validation and subsequent development by industry. The intended outcomes are: (1) Invention, assessment, identification, verification and validation of novel and high techno-economic-potential WEC technology concepts to deliver high-confidence "seeds" for subsequent industrial development to full commercial application and economic viability (2) Development and delivery of WEC technology innovation and assessment methodologies and tools and provision of these as services and for free use by industry and the entire sector (3) International collaboration for global best practice alignment of assessment and innovation methods.

innovation↗

Comparison between Flownex and Corona thermal-hydraulic models for a single HTR prismatic fuel assembly - 18544

Computational tools and methodologies that can perform thermal-hydraulic analyses to reasonably predict the temperature distribution for the whole core of HTRs are useful for operational and safety analyses. In this paper, Flownex (a system code based on a one-dimensional thermal-fluid network methodology) and CORONA (Core Reliable Optimization and thermo-fluid Network Analysis) thermal-hydraulic models and results for a vertically stacked single fuel assembly will be compared. In Flownex, a basic unit cell containing part of the graphite and the associated fuel elements and coolant channels was developed. CORONA uses a basic unit cell concept for generating computational grids using several types of basic unit cells to model the heat transfer through the hexagonal blocks and a 1-D formulation to model the flow through the coolant channels. In CORONA, computational grids are generated using a combination of pre-generated mesh cells. The coolant channels and fuel rods are modelled explicitly. Flownex in contrast, models fuel and coolant channels implicitly by defining representative coolant channels, fuel rods and coated particle layers associated with each unit cell. Flownex can therefore model temperatures at coated particle level and also through each graphite block. The computational mesh employed by Flownex is much coarser than the mesh employed by CORONA. In both models, the helium gap between the fuel compact and the graphite block is modelled as stagnant. Flownex results were found to be of the same order of magnitude as those obtained using CORONA. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect on the condition of the metal in A K-300-3.5 turbine owing to multicycle fatigue from participation of a power generating unit in grid frequency and power regulation

The effect on the condition of the rotor material owing to multicycle fatigue caused by variable stresses during participation of a power generating unit in grid frequency and power regulation is evaluated using the K-300-23.5 steam turbine as an example. It is shown that during normalized primary frequency regulation the safety factor is at least 50, while during automatic secondary regulation of frequency and power there is essentially no damage to the metal.

42 ENGINEERING↗

Adaptive Generation of Multimaterial Grids from imaging data for Biomedical Lagrangian Fluid-Structure Simulations

Spatial discretization of complex imaging-derived fluid-solid geometries, such as the cardiac environment, is a critical but often overlooked challenge in biomechanical computations. This is particularly true in problems with Lagrangian interfaces, where, the fluid and solid phases must match geometrically. For simplicity and better accuracy, it is also highly desirable for the two phases to share the same surface mesh at the interface between them. We outline a method for solving this problem, and illustrate the approach with a 3D fluid-solid mesh of the mouse heart. An MRI perfusion-fixed dataset of a mouse heart with 50μm isotropic resolution was semi-automatically segmented using a customized multimaterial connected-threshold approach that divided the volume into non-overlapping regions of blood, tissue and background. Subsequently, a multimaterial marching cubes algorithm was applied to the segmented data to produce two detailed, compatible isosurfaces, one for blood and one for tissue. Both isosurfaces were simultaneously smoothed with a multimaterial smoothing algorithm that exactly conserves the volume for each phase. Using these two isosurfaces, we developed and applied novel automated meshing algorithms to generate anisotropic hybrid meshes on arbitrary biological geometries with the number of layers and the desired element anisotropy for each phase as the only input parameters. Since our meshes adapt to the local feature sizes and include boundary layer prisms, they are more efficient and accurate than non-adaptive, isotropic meshes, and the fluid-structure interaction computations will tend to have relative error equilibrated over the whole mesh.

59 BASIC BIOLOGICAL SCIENCES↗

Neural Network Predictive Controller for Grid-Connected Virtual Synchronous Generator

In this paper, a neural network predictive controller is proposed to regulate the active and the reactive power delivered to the grid generated by a three-phase virtual inertia-based inverter. The concept of the conventional virtual synchronous generator (VSG) is discussed, and it is shown that when the inverter is connected to non-inductive grids, the conventional PI-based VSGs are unable to perform acceptable tracking. The concept of the neural network predictive controller is also discussed to replace the traditional VSGs. This replacement enables inverters to perform in both inductive and non-inductive grids. The simulation results confirm that a well-trained neural network predictive controller illustrates can adapt to any grid impedance angle, compared to the traditional PI-based virtual inertia controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of Cascaded H-Bridge Multilevel Inverter with Individual MPPT for Grid-Connected Photovoltaic Generators

A single-phase cascaded H-bridge multilevel inverter for a grid-connected photovoltaic (PV) system with nonactive power compensation is presented in this paper. To maximize the solar energy extraction of each PV string, an individual maximum power point tracking (MPPT) control scheme is applied, which allows the independent control of each dc-link voltage. A generalized nonactive power theory is applied to generate the nonactive current reference. Within the inverters™ capability, the local consumption of nonactive power is provided to realize power factor correction. A single-phase modular cascaded multilevel inverter prototype has been built. Each H-bridge is connected to a 195 W solar panel. Simulation and experimental results are presented to validate the proposed ideas.

14 SOLAR ENERGY↗

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Rapid generation of optimal generalized Monkhorst-Pack grids

In this report computational modeling of the properties of crystalline materials has become an increasingly important aspect of materials research, consuming hundreds of millions of CPU-hours at scientific computing centers around the world each year, if not more. A routine operation in such calculations is the evaluation of integrals over the Brillouin zone. We have previously demonstrated that performing such integrals using generalized Monkhorst-Pack k-point grids can roughly double the speed of these calculations relative to the widely-used traditional Monkhorst-Pack grids. However the generation of optimal generalized Monkhorst-Pack grids is not implemented in most software packages due to the computational cost and difficulty of identifying the best grids. To address this problem, we present new algorithms that allow rapid generation of optimal generalized Monkhorst-Pack grids on the fly. We demonstrate that the grids generated by these algorithms are on average significantly more efficient than those generated using existing algorithms across a range of grid densities. For grids that correspond to a real-space supercell with at least 50 Å between lattice points, which is sufficient to converge density functional theory calculations within 1 meV/atom for nearly all materials, our algorithm finds optimized grids in an average of 0.19 s on a single processing core. To facilitate the widespread adoption of this approach, we present new open-source tools including a library designed for integration with third-party software packages.

36 MATERIALS SCIENCE↗

A New Multi-Scale State Estimation Framework for the Next Generation of Power Grid EMS

Accurate system state information under various operation conditions is a prerequisite for power grid monitoring and efficient control. To achieve that goal, a new multi-scale state estimation framework is proposed, paving the way for the development of next generation of energy management system (EMS). The developed framework consists of three key components, namely the static state estimation (SSE) module, the dynamic state estimation (DSE) module, the interfaces and switching logics between the two modules. Specifically, the singular spectrum analysis (SSA)-based change point detection approach is developed to monitor the system continuously. If no event is detected by the SSA, the robust SSE using both SCADA and PMU measurements is executed. Otherwise, the event is declared and the results from SSE are used to derive the initial condition for DSE. During the transient process, only PMU-based DSE is executed for system monitoring and it will be terminated when SSA does not detect any change point of the system. After that, the DSE results are forwarded for SSE initialization and bus voltage magnitude and angle estimations. Simulation results carried out on the IEEE 39-bus system demonstrate the effectiveness and benefits of the proposed framework.

Power system state estimation, energy management s↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗