Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics

A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA's Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were ≥ 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.

Ion Thruster↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics

A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA’s Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were ≥ 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.

George C. Soulas↗

Hourglass control in staggered-grid hydrodynamics using virtual element stabilization techniques

Numerical simulations using the staggered-grid hydrodynamics (SGH) discretization suffer from hourglass instabilities. In this work, we develop a stabilization method to suppress the hourglass instabilities using techniques from the virtual element method (VEM). The stiffness matrix of the VEM consists of two terms: the consistency matrix which is rank deficient and the stability matrix. Here, we first show that in two dimensions and on general polygons, the stiffness matrix of the SGH is identical to the consistency matrix of the linear VEM for both the diffusion equation and the linear elasticity equation. These analyses explain the origin of the hourglass instabilities of the SGH discretization method, and establish a theoretical foundation for our proposed stabilization method by augmenting the stiffness matrix of the SGH discretization using the VEM stability matrix. Then, we present numerical examples using Lagrangian SGH simulations. The numerical experiments demonstrate that the proposed VEM stabilization method is effective at eliminating hourglass modes in the SGH discretization.

97 MATHEMATICS AND COMPUTING↗

Boundary-Layer Stability Analysis of the Mean Flows Obtained Using Unstructured Grids

Boundary-layer stability analyses of mean flows extracted from unstructured-grid Navier- Stokes solutions have been performed. A procedure has been developed to extract mean flow profiles from the FUN3D unstructured-grid solutions. Extensive code-to-code validations have been performed by comparing the extracted mean ows as well as the corresponding stability characteristics to the predictions based on structured-grid solutions. Comparisons are made on a range of problems from a simple at plate to a full aircraft configuration-a modified Gulfstream-III with a natural laminar flow glove. The future aim of the project is to extend the adjoint-based design capability in FUN3D to include natural laminar flow and laminar flow control by integrating it with boundary-layer stability analysis codes, such as LASTRAC.

Liao, Wei↗

Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Fourth Edition

As the world increasingly seeks low-carbon energy solutions, solar power emerges as the most abundant resource on our planet. However, the challenge of effectively harnessing this energy is crucial in the coming years. Solar energy applications such as photovoltaics, solar heating and cooling, and concentrating solar power use different technologies to capitalize on sunlight. Each system has unique capabilities and requirements, underscoring the need for reliable information about solar resources across diverse installations, from residential rooftops to large-scale power plants. This is especially important for substantial projects, often exceeding $1 billion in construction costs. Before embarking on such ventures, it is imperative to obtain accurate data concerning solar resource quality and reliability at specific sites. Developers require detailed historical information, including seasonal, daily, hourly, and, ideally, subhourly variability to effectively predict a power plant's annual performance. Without these vital data, financial analyses fall short. Moreover, with the growing adoption of distributed photovoltaics, integrating these generation sources becomes critical to maintaining grid reliability and stability. By accurately forecasting generation patterns, utilities and system operators can facilitate greater integration of solar energy, thus ensuring the operational stability of the grid. The complexity and importance of these issues have prompted the foremost experts in the field to collaborate under the auspices of the International Energy Agency's (IEA's) Photovoltaic Power Systems Programme (PVPS) Task 16 to publish this handbook, which summarizes state-of-the-art information about all these topics. The efforts focus on providing reliable data and insights that can help shape our investments in solar energy and drive a sustainable future.

14 SOLAR ENERGY↗

A solution adaptive grid procedure for an upwind parabolized flow solver

A solution adaptive grid procedure based on an error equi-distribution scheme is developed and applied to a Parabolized Navier-Stokes solver. An improved method for selecting weighting functions is introduced which involves normalizing a combination of flowfield gradients and curvature of a number of dependent variables and then selecting the largest at each point. The scheme re-distributes grid points line-by-line, with grid point motion controlled by forces analogous to tensional and torsional spring forces with the spring constants set equal to the weighting functions. Torsional terms are functions of the grid point positions along neighboring grid lines and provide grid smoothness and stability. A grid-fitting scheme is introduced for external flows in which the number of grid points in the freestream are reduced to a minimum. Results for several problems are presented to demonstrate the improvements obtainable with the solution adaptive grid procedure.

Harvey, Albert D.↗

IEEE PES GM Poster - Cyber-Informed Engineering Approach to Mitigating BESS Supply Chain Concerns

Battery energy storage systems (BESS) are increasingly important to meet the needs of grid resilience and reliability. BESS provide critical grid services, maintaining stability of the grid with increased variable conditions. However, there are significant geopolitical and security concerns regarding their operation in critical infrastructure, due to lack of a domestic supply chain and prevalence of foreign entity of concern (FEOC) components in BESS and associated inverter-based resources. The supply chain challenge is dually exacerbated by a lack of alternative suppliers who can meet the economic targets for energy delivery and a potentially adversarial supply chain. Solutions are needed to secure components, addressing mixed layers of risk and engineering controls. This paper presents a specific application of Cyber-Informed Engineering (CIE) principles for BESS and recommends an alternative strategy to blocking the supply chain, ensuring that grid modernization targets can be met despite lack of a validated or secure supply chain. This study focuses on the United State (U.S.) use case, but the process can be applied globally to address supply chain security challenges. CIE practices represent the next step in functional assurance and risk mitigation, ensuring optimal resource allocation and enhancing security measures to safeguard the future of energy in the U.S. and beyond.

25 - ENERGY STORAGE↗

Rapid Aero Modeling of a Lift+Cruise UAM Configuration for Stability and Control Using Overset Grid CFD

This talk will address some aspects of an effort to develop both static and dynamic stability and control derivatives of a generic Lift+Cruise Urban Air Mobility vehicle. In particular, the use of NASA overset grid CFD packages OVERFLOW and Chimera Grid Tools allowed for rapid grid and solution generation while varying many database factors. Approach details include coarse gridding and control effectors, rotor disk modeling, convergence evaluation, and parallel execution on a midrange compute resource. A brief *description of the Rapid Aero Modeling (RAM) approach, including design of experiments and response surface modeling, will be given, and recent simulations of powered and unpowered dynamic multisine maneuvers will be presented.

Overset Grid CFD↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial Energy Storage Review

As the United States moves to net-zero carbon emission by 2050, a transition to renewable energy generation is required. However, the variable nature of renewable energy generation at high penetrations can cause imbalances in generation and transmission of electricity. These imbalances can be circumvented by the deployment of energy storage. Global industrial energy storage is projected to grow 2.6 times in the coming decades, from just over 60 GWh to 167 GWh in 2030. The challenge is to balance energy storage capabilities with the power and energy needs for particular industrial applications. Energy storage technologies can be classified by the form of the stored energy. The most common forms include thermal, chemical, electrochemical, and mechanical storage technologies. The most appropriate storage technology will depend on the unique energy needs of the industrial application. The purpose of this report is to provide a review of energy storage technologies relevant to the U.S. industrial sector, highlighting the applications in industry that will benefit from increased integration of energy storage, as well as the respective challenges and opportunities unique to integrating different storage technologies.

25 ENERGY STORAGE↗

Electrifying Connection, Managing Impacts to Transit & the Grid

This brochure describes the potential impacts at scale electrified transportation may have on the grid by analyzing current deployments and provides recommendations onthe available resources or solutions to help stabilize the grid in other regions.

Source record↗

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental investigation of flow turbulence effects on premixed methane-air flames

An experimental assessment of a novel technique for measuring turbulent flame speeds was conducted. Unconfined, V-shaped, methane-air flames stabilized in grid turbulence were investigated. Local flame speeds were measured employing hot film and laser anemometry and fine wire thermocouples. The measurement instrumentation was extended to provide mean and fluctuating temperature information about turbulent flames. The flames in grid turbulence exhibited an increase in flame speed with increased length scale and velocity fluctuations. At high combustor velocities, stabilizer wake turbulence dominated the flame properties.

Smith, K. O.↗

Automatic Boundary-Layer Adaptation of Structured Grids in VULCAN-CFD

In supersonic and hypersonic flow computations, well-resolved boundary layers are essential for accurate quantification of surface heating and transition prediction, particularly via linear stability analysis. Grid design for hypersonic flows with shocks, boundary-layer separation, and/or complex mean flow features incorporating spanwise/azimuthal inhomogeneities is a difficult issue. In comparison to a manual grid adaptation procedure, an autonomous grid adaptation technique offers significant improvements in computing time and solution quality. The VULCAN-CFD solver already includes a validated procedure for automatic adaption of structured grids to the bow shock. The present focus is on implementing an automatic boundary-layer adaptation capability in VULCAN-CFD that adapts structured, multiblock grids to both the bow shock and the boundary layer at the same time. The boundary-layer adaptation algorithm allows the user to specify the number of cells within the boundary layer, along with the input parameters used for detecting the edge of the boundary layer, namely, the variable used in the edge detection criterion,the edge detection method, the detection direction, and the relaxation factor used during the morphing of the grid. The algorithm automatically distributes grid points along the wall-normal direction to achieve a smooth variation in grid spacing from the edge of the boundary layer to a"junction" location within the outer part of the grid. Illustrative results are presented for three different high-speed configurations: the two-dimensional flow over a cylinder at Mach 17.6 and unit Reynolds number of Re=0.38x10^6 m^-1, the axisymmetric flow over a cone-cylinder-flare model at Mach 6.0 and Re = 10.5×10^6 m^-1, and the three-dimensional flow over a blunt, 7-degree half-angle cone at 5-degree angle of attack in a Mach 9.79 flow with Re = 17.1×10^6 m^-1. The automated boundary-layer adaptation is shown to provide an adequate grid topology that is aligned with the bow shock in the outer part of the grid and also resolves the viscous boundary-layer region close to the surface.

boundary layer transition↗