Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water

Up-and-Coming IMCs

While the good oxidation and environmental resistance, high melting points, and comparatively low densities of such ordered intermetallics as Ti 3 Al, NiAl, FeAl, and NbAl 3 render them good candidates for advanced aerospace structures, their poor toughness at low temperatures and low strength at elevated temperatures have prompted the development of fiber-reinforced intermetallic-matrix composites (IMCs) with more balanced characteristics. Fabrication methods for continuous-fiber IMCs under development include the P/M 'powder cloth' method, the foil/fiber method, and thermal spraying. The ultimate success of IMCs depends on fibers truly compatible with the matrix materials.

Randy Bowman

Real-space visualization of a defect-mediated charge density wave transition

Here, we study the coupled charge density wave (CDW) and insulator-to-metal transitions in the 2D quantum material 1T-TaS 2 . By applying in situ cryogenic 4D scanning transmission electron microscopy with in situ electrical resistance measurements, we directly visualize the CDW transition and establish that the transition is mediated by basal dislocations (stacking solitons). We find that dislocations can both nucleate and pin the transition and locally alter the transition temperature T c by nearly ~75 K. This finding was enabled by the application of unsupervised machine learning to cluster five-dimensional, terabyte scale datasets, which demonstrate a one-to-one correlation between resistance—a global property—and local CDW domain-dislocation dynamics, thereby linking the material microstructure to device properties. This work represents a major step toward defect-engineering of quantum materials, which will become increasingly important as we aim to utilize such materials in real devices.

4D-STEM

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing

Minimum Heating Re-Entry Trajectories for Advanced Hypersonic Launch Vehicles

Optimal re-entry trajectories are generated for reusable launch vehicles which minimize: (1) the heat absorbed at the vehicle surface, (2) the lower surface temperature, and (3) the heat absorbed by the internal structure. The approach uses the energy state approximation technique and a finite control volume heat transfer code coupled to a flight path integration code. These trajectories are compared to the optimal re-entry trajectory minimizing the integrated convective heat rate to determine which trajectory produces the minimum internal structural temperatures for a given thermal protection system. Three different thermal protection systems are considered: tile, blanket, and metallic.

Robert Windhorst

Salt to Metal to Salt Heat Transfer in Narrow Fuel Pins (Final CRADA Report)

This work focused on improving the understanding and modeling of conjugate heat transfer in the Stable Salt Reactor (SSR), particularly the transfer of heat from molten fuel salt inside narrow fuel pins, through the metal cladding and into the surrounding coolant salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

NASA 50 amp hour nickel cadmium battery waste heat determination

A process for determining the waste heat generated in a 50-ampere-hour, nickel cadmium battery as a function of the discharge rate is described and results are discussed. The technique involved is essentially calibration of the battery as a heat transfer rate calorimeter. The tests are run at three different levels of battery activity, one at 40-watts of waste heat generated, one at 60, and one at 100. Battery inefficiency ranges from 14 to 18 percent at discharge rates of 284 to 588 watts, respectively and top-of-cell temperatures of 20 C.

Mueller, V. C.

Thermal Protection Facility: Taking the Heat

Video highlighting the products and manufacturing capabilities of the Thermal Protection Facility at Kennedy Space Center which is part of the JSC EA/ES division. This record includes an mp4 video with a run time of 9 min. 13 sec.; in color; with sound.

TPSF

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Behavior of 2-Cell CPV Ni-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at -5 C. The pulse tests consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 8 % state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation. The results show that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Vaidyanathan, Hari

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean

Numerical simulation of frost formation and heat transfer on fin-and-tube heat exchangers in turbulent cross-flow

Frost formation in fin-and-tube heat exchangers in turbulent cross-flow presents significant challenges in industrial refrigeration applications, affecting heat transfer efficiency and operational reliability. The purpose of this work is to investigate frost deposition and growth on a staggered bank of a fin-and-tube freezer coil under turbulent forced convection conditions. The focus here is on investigating conditions that closely replicate real-world scenarios in large walk-in industrial freezers. Using a direct numerical simulation approach, we examine the flow dynamics and thermal behaviour in the presence of frost, considering turbulent regimes characterized by a Reynolds number in the range 1050 ≤ R e D , avg ≤ 4800 , with the characteristic length being the outer diameter of the tube and the velocity being the bulk fluid velocity between the plates (fins). Computational fluid dynamics simulations are employed to resolve the interactions between turbulent airflow and the frost layer. Our approach incorporates a modified immersed boundary method and a slow-time acceleration technique to address the complex dynamic interface between the continuously evolving frost layer and the flowing air stream. Our findings indicate that frost forms more on the sides of the finned surfaces (plates) and less on the tubes themselves. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics