Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH FIELD MAGNET FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Snowmass Topical Group Summary Report: IF04 -- Trigger and Data Acquisition Systems

A trend for future high energy physics experiments is an increase in the data bandwidth produced from the detectors. Datasets of the Petabyte scale have already become the norm, and the requirements of future experiments -- greater in size, exposure, and complexity -- will further push the limits of data acquisition technologies to data rates of exabytes per seconds. The challenge for these future data-intensive physics facilities lies in the reduction of the flow of data through a combination of sophisticated event selection in the form of high-performance triggers and improved data representation through compression and calculation of high-level quantities. These tasks must be performed with low-latency (i.e. in real-time) and often in extreme environments including high radiation, high magnetic fields, and cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass Topical Group Summary Report: IF04 -- Trigger and Data Acquisition Systems

A trend for future high energy physics experiments is an increase in the data bandwidth produced from the detectors. Datasets of the Petabyte scale have already become the norm, and the requirements of future experiments -- greater in size, exposure, and complexity -- will further push the limits of data acquisition technologies to data rates of exabytes per seconds. The challenge for these future data-intensive physics facilities lies in the reduction of the flow of data through a combination of sophisticated event selection in the form of high-performance triggers and improved data representation through compression and calculation of high-level quantities. These tasks must be performed with low-latency (i.e. in real-time) and often in extreme environments including high radiation, high magnetic fields, and cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White paper on NIF Discovery Science and frontier regimes of HEDP

Over the past two decades, experimental capabilities at high energy density (HED) facilities such as the National Ignition Facility (NIF), Omega, and Omega EP lasers, and the Z pulsed power facility are able to make precision measurements of fundamental quantities such as equations of state (EOS), material phase, opacities, and ionization levels Z. Flow based quantities are also being studied, such as hydrodynamic instabilities, evolution into turbulence, turbulent dynamo magnetic field amplification, magnetic reconnection; plasma instabilities, plasma wakefield particle acceleration; and relativistic plasma phenomena, such as (e + ,e - ) pair creation. Experimental regimes can be created that reproduce conditions relevant to planetary and exoplanet interiors, stellar interiors, the interiors of brown dwarfs, and the envelope conditions of white dwarf stars. Diagnostic techniques have been developed hand in hand with these new experimental regimes that can be accessed. In this white paper, a brief summary of key experimental achievements from the NIF Discovery Science (basic science) program will be presented; followed by a discussion of current challenges, needs, and potential paths forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetohydrodynamics in free surface liquid metal flow relevant to plasma-facing components

Abstract While flowing Liquid Metal (LM) Plasma-Facing Components (PFCs) represent a potentially transformative technology to enable long-pulse operation with high-power exhaust for fusion reactors, Magnetohydrodynamic (MHD) drag in the conducting LM will reduce the flow speed. Experiments have been completed in the linear open-channel LMX-U device [Hvasta et al 2018 Nucl. Fusion 58 01602] for validation of MHD drag calculations with either insulating or conducting walls, with codes similar to those used to design flowing LM PFCs for a Fusion Nuclear Science Facility [Kessel et al 2019 Fusion Sci. Technol . 75 886]. We observe that the average channel flow speed decreased with the use of conducting walls and the strength of the applied transverse magnetic field. The MHD drag from the retarding Lorentz force resulted in an increase of the LM depth in the channel that ‘piled up’ near the inlet, but not the outlet. As reproduced by OpenFOAM and ANSYS CFX calculations, the magnitude and characteristics of the pileup in the flow direction increased with the applied traverse magnetic field by up to 120%, as compared to the case without an applied magnetic field, corresponding to an average velocity reduction of ∼45%. Particle tracking measurements confirmed a predicted shear in the flow speed, with the surface velocity increasing by 300%, despite the 45% drop in the average bulk speed. The MHD effect makes the bulk flow laminarized but keeps surface waves aligned along the magnetic field lines due to the anisotropy of MHD drag. The 3D fringe field and high surface velocity generate ripples around the outlet region. It was also confirmed that the MHD drag strongly depends on the conductivity of the channel walls, magnetic field, and volumetric flow rate, in agreement with the simulations and a developed analytical model. These validated models are now available to begin to determine the conditions under which the ideal LM channel design of a constant flow speed and fluid depth could be attained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Bound States in the Continuum Enabled by Magnetic Resonances Coupled to a Mirror

Dielectric metasurfaces made of high refractive index and low optical loss materials have emerged as promising platforms to achieve high-quality factor modes enabling strong light–matter interaction. Bound states in the continuum have shown potential to demonstrate narrow spectral resonances but often require asymmetric geometry and typically feature strong polarization dependence, complicating fabrication and limiting practical applications. Here, we introduce a novel approach for designing high-quality bound states in the continuum using magnetic dipole resonances coupled to a mirror. The resulting metasurface has simple geometric parameters requiring no broken symmetry. To demonstrate the unique features of our photonic platform we show a record-breaking third harmonic generation efficiency from the metasurface benefiting from the strongly enhanced electric field at high-quality resonances. Our approach mitigates the shortcomings of previous platforms with simple geometry enabling facile and large-area fabrication of metasurfaces paving the way for applications in optical sensing, detection, quantum photonics, and nonlinear devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Soft Matter Sample Environments for Time-Resolved Small Angle Neutron Scattering Experiments: A Review

With the promise of new, more powerful neutron sources in the future, the possibilities for time-resolved neutron scattering experiments will improve and are bound to gain in interest. While there is already a large body of work on the accurate control of temperature, pressure, and magnetic fields for static experiments, this field is less well developed for time-resolved experiments on soft condensed matter and biomaterials. We present here an overview of different sample environments and technique combinations that have been developed so far and which might inspire further developments so that one can take full advantage of both the existing facilities as well as the possibilities that future high intensity neutron sources will offer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HERMES 2019 Upgrade Characterization - Quick Look Report (UUR)

Characterizing the electromagnetic environment created by the recently upgraded HERMES III pulser is the primary objective addressed by this report. The pulser upgrade design was intended not only to provide higher electric field and magnetic field illumination amplitudes but also to provide a more collimated beam, focused along the center-line of the courtyard. For high-voltage pulsers to be useful as qualification systems, they must have the requisite peak values and uniform, predictable peak field spatial patterns. To assess the peak electric field values and uniformity of the spatial pattern of the electric fields for the upgraded HERMES system, a 1 6 full-power shot illumination of 9 electric and 9 magnetic field sensors in the courtyard of the HERMES III facility was conducted. The data acquired from this test showed an increase an increase in electric field amplitude, but still an asymmetry in the spatial distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

rf chopper for prebunched radioactive ion beams

An rf chopper system is being designed for the ReAccelerator (ReA) linac at the Facility for Rare Isotope Beams at Michigan State University. The 80.5 MHz ReA radio-frequency quadrupole accelerates prebunched 16.1 MHz beams, producing four satellite bunches for every main bunch. The chopper system includes an rf deflector that kicks every bunch vertically to spatially separate main and satellite bunches. A constant magnetic field superimposed with the chopper electric field biases the beam trajectory to ensure the high-intensity bunches do not experience a net deflection and are injected straight to the ReA6 cryomodule or sent for experiments. The kicked bunches are low in intensity and will be sent to a beam dump, resulting in a clean 16.1 MHz beam structure, which allows for a reliable time-of-flight separation of the isotopes. Published by the American Physical Society 2024

Physics↗

Extended-magnetohydrodynamics in under-dense plasmas

Extended-magnetohydrodynamics (MHD) transports magnetic flux and electron energy in high-energy-density experiments, but individual transport effects remain unobserved experimentally. Two factors are responsible in defining the transport: electron temperature and electron current. Here, each electron energy transport term has a direct analog in magnetic flux transport. To measure the thermally driven transport of magnetic flux and electron energy, a simple experimental configuration is explored computationally using a laser-heated pre-magnetized under-dense plasma. Changes to the laser heating profile precipitate clear diagnostic signatures from the Nernst, cross-gradient-Nernst, anisotropic conduction, and Righi-Leduc heat-flow. With a wide operating parameter range, this configuration can be used in both small and large scale facilities to benchmark MHD and kinetic transport in collisional/semi-collisional, local/non-local, and magnetized/unmagnetized regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and modeling of indirectly driven magnetized implosions on the NIF

The use of magnetic fields to improve the performance of hohlraum-driven implosions on the National Ignition Facility (NIF) is discussed. The focus is on magnetically insulated inertial confinement fusion, where the primary field effect is to reduce electron-thermal and alpha-particle loss from the compressed hotspot (magnetic pressure is of secondary importance). We summarize the requirements to achieve this state. The design of recent NIF magnetized hohlraum experiments is presented. These are close to earlier shots in the three-shock, high-adiabat (BigFoot) campaign, subject to the constraints that magnetized NIF targets must be fielded at room-temperature, and use ≲1 MJ of laser energy to avoid the risk of optics damage from stimulated Brillouin scattering. We present results from the original magnetized hohlraum platform, as well as a later variant that gives a higher hotspot temperature. In both platforms, imposed fields (at the capsule center) of up to 28 T increase the fusion yield and hotspot temperature. Integrated radiation-magneto-hydrodynamic modeling with the Lasnex code of these shots is shown, where laser power multipliers and a saturation clamp on cross-beam energy transfer are developed to match the time of peak capsule emission and the P2 Legendre moment of the hotspot x-ray image. The resulting fusion yield and ion temperature agree decently with the measured relative effects of the field, although the absolute simulated yields are higher than the data by 2.0−2.7×. The tuned parameters and yield discrepancy are comparable for experiments with and without an imposed field, indicating the model adequately captures the field effects. Self-generated and imposed fields are added sequentially to simulations of one BigFoot NIF shot to understand how they alter target dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strongly Tapered Helical Undulator System for Fast-greens Installation

RadiaBeam, in collaboration with UCLA and Fermilab, is developing a strongly tapered helical undulator system for the Tapering Enhanced Stimulated Superradiant Amplification experiment at 515 nm (TESSA-515). The experiment will be carried out at the FAST facility at Fermilab as a Gamma-Ray high Efficiency ENhanced Source (FAST-GREENS). The undulator system was designed by UCLA, engineered by RadiaBeam, and will be installed on the beamline at Fermilab (FNAL). The design is based on a permanent magnet Halbach scheme of four 1-meter long undulator sections; two of which have been completed and installed. The undulator period is fixed at 32 mm and the magnetic field amplitude can be tapered by tuning the gap along the interaction. Each magnet can be individually adjusted by 1 mm, offering up to 25% magnetic field tunability with a minimum gap of 5.58 mm. This paper discusses the design and engineering of the undulator system and the stage 0 installation status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

Unveiling the Interplay: Cold Work, Recrystallization, and Flux Expulsion in SRF Cavities

The fabrication of SRF cavities from sheet materials includes deep-drawing, electron beam welding, chemical and mechanical polishing, high-temperature heat treatment, and material diffusion. The performance of these cavities is frequently limited by magnetic flux trapping giving rise to additional rf loss. In this presentation, we thoroughly examine how recrystallization influences flux expulsion in SRF cavities, using cold-worked niobium sheets from various suppliers. Our findings reveal that cold-worked sheets enhance flux expulsion, especially at lower heat treatment temperatures, by promoting improved recrystallization. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavities with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 C/3h

Dhakal, P. [Old Dominion Univ., Norfolk, VA (Unite↗

Concept Design and Analysis of the Magnet System of the Sustained High Power Density Tokamak Facility

A recent National Academy study recommended a next-step sustained high power density (SHPD) facility for the United States that can be a bridge to a compact fusion pilot plant. A design has been initiated to investigate a possible SHPD non-deuterium-tritium device that builds upon recent low aspect ratio tokamak studies. Here, a 1.2-m device with a 2.4 aspect ratio has been chosen to evaluate physics performance goals within a double-null plasma machine arrangement centered on three component features: high current density toroidal field (TF) and central ohmic heating/poloidal field (PF) coils, liquid metal divertor/first wall systems, and the integration of a limited set of outboard dual-coolant lead lithium test blankets that can be maintained within a vertical maintenance approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

Thomas Jefferson National Accelerator Facility (Jeffer- son Lab) currently studies the feasibility of upgrading its energy to 22 GeV. It considers addition of six more linac passes. The highest energy passes will share two new arcs designed using the Fixed-Field Alternating Gradient (FFA) technology. The FFA arcs are built using permanent combined-function magnets. They will be connected to the linacs through transition sections that will match the optics of all six passes to the linacs. With the high number of con- straints and the limited space available, we are investigating a parametric resonance technique to match the optics quasi- independently at each energy. A resonance is excited at each individual energy to selectively control its optics. The reso- nant dipole and quadrupole kick harmonics are imposed for all energies simultaneously using Panofsky corrector mag- nets placed throughout the FFA arcs. This paper presents the current progress on that transition section design

Deitrick, K.↗