Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Restore-L Satellite Servicing Internship Final Report

An experiment was conducted to determine whether a sample of shorter flexible metal hoses could sustain tensile loads of up to 200 lbf and continue to meet the minimum mission requirements. The purpose of this experiment was to determine if tension loads during the processing of the hoses compromise performance. With this information, it will be decided whether the flight flex-hose manufacturer should proceed with the testing of the full-scale flex-hoses. To reduce the time and funding required for this test, a test fixture was designed and assembled in the Engineering Development & Operations (EDO) test facility. In this test fixture, two Engineering Development Unit (EDU) flex-hoses were loaded with free floating weights up to 350 lbf. A load of 200 lbf equates to the maximum expected loading with a margin of safety, thus all data recorded after 200 lbf was purely for reference. Measurements were taken using a tape measure and a custom datum measurement system to record the loaded and unloaded length of each flex-hose at various loads. Any permanent stretching beyond a 1/8th of an inch was indicative of inelastic yielding. The loading of each flex-hose was done with an initial weight 80 lbf and was increased to 100 lbf. Additional loading up to 350 lbf was done by 50 lbf increments thereafter. During the performance of the test, slippage occurred in the mounting of the flex-hoses in the test fixture. The first slippage occurred during the testing of the first flex-hose due to the collar of the flex-hose slipping within the collet of the top Kellem. As a result, the first flex-hose test was terminated early to modify the fixture. Due to the flex-hose not inelastically yielding, the test was repeated on the first flex hose. This test resulted in another instance of slippage in the upper collar of the Kellem due to tape interfering with the securing of a collet around the collar of the flex-hose. The test was then continued with one more slippage of the flex-hose within the collet of the bottom Kellem. Preventive measures were taken for future slippage, and the second hose remained secure during testing.Once the tests were concluded, the elongation of each hose was analyzed for inelastic yielding. Both flex-hoses stretched a measurable and repeatable amount under loading, however, this stretching was recovered once each hose was unloaded. As a result, both EDU flex-hoses did not experience any inelastic yielding during the tension testing. Once received, one additional flex-hose will be tested for yielding, but at the time of this paper, the recommendation is to proceed with testing of the full-scale flex-hoses at the flex-hose manufacturer.

Dziekan, Joseph↗

Extensive Aging and Evaluation of Nonmetallic Components in the Waste Transfer System at Hanford - 18371

Nonmetallic materials are used in the United States Department of Energy's Hanford Site Tank Farm waste transfer system. These materials include the inner primary hoses in the hose-in-hose transfer lines (HIHTLs), Garlock{sup R} gaskets, ethylene propylene diene monomer (EPDM) O-rings, and other nonmetallic materials. These nonmetallic materials are exposed to β and γ radiation, caustic solutions as well as high temperature and pressure stressors. How the nonmetallic components react to each of these stressors individually has been well established. However, simultaneous exposure of these stressors has not been evaluated and is of great concern to Hanford Site engineers. FIU-ARC engineers worked closely with key Hanford HLW personnel to develop an experimental test plan that determines how these nonmetallic components react to various simultaneous stressor exposures. In this paper, data obtained from experimental testing of the hose-in-hose transfer lines, Garlock{sup R} gaskets and EPDM O-rings used in the Hanford tank farm waste transfer system under simultaneous stressor exposures is presented. The stressor exposure experiments consisted of combinations of simultaneous stressor exposure of caustic solution and elevated temperature stressors. Evaluation of materials that have been conditioned with the various stressors for duration of 6-months was conducted and compared with baseline unexposed materials. Evaluations included burst pressure tests of the EPDM hose-in-hose transfer lines, leak pressure tests of the EPDM O-rings and Garlock{sup R} gaskets, material tensile strength test of EPDM and Garlock{sup R} coupons. Scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX) was conducted on aged and un-aged baseline coupons to determine if there was any change in the surface microstructure and to see how far the NaOH penetrated analysis is continuing. Conclusions from the 6-month testing indicates that the specimens did not see a significant in the pressure tests, but the material properties of both the EPDM and Garlock{sup R} coupons did see changes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coherent seeding of self-modulated plasma wakefield accelerators

The growth of the beam self-modulation and hosing instabilities initiated by a seed wakefield is examined. Although the growth rates for the self-modulation and hosing instabilities are comparable, it is shown that an externally excited wakefield can be effective in selectively seeding the beam radial self-modulation, enabling the beam to fully modulate before strong beam hosing develops. Methods for coherent seeding are discussed.

43 PARTICLE ACCELERATORS↗

HLW Flexible jumper materials compatibility evaluation

H-Tank Farm Engineering tasked SRNL/Materials Science & Technology (MS&T) to evaluate the compatibility of Goodyear Viper® chemical transfer hose with HLW solutions. The hose is proposed as a flexible Safety Class jumper for up to six months service. SRNL/MS&T performed various tests to evaluate the effects of radiation, high pH chemistry and elevated temperature on the hose, particularly the inner liner. Test results suggest an upper dose limit of 50 Mrad for the hose. Room temperature burst pressure values at 50 Mrad are estimated at 600- 800 psi, providing a safety factor of 4.0-5.3X over the anticipated operating pressure of 150 psi and a safety factor of 3.0-4.0X over the working pressure of the hose (200 psi), independent of temperature effects. Radiation effects are minimal at doses less than 10 Mrad. Doses greater than 50 Mrad may be allowed, depending on operating conditions and required safety factors, but cannot be recommended at this time. At 250 Mrad, burst pressure values are reduced to the hose working pressure. At 300 Mrad, burst pressures are below 150 psi. At a bounding continuous dose rate of 57,870 rad/hr, the 50 Mrad dose limit is reached within 1.2 months. Actual dose rates may be lower, particularly during non-transfer periods. Refined dose calculations are therefore recommended to justify longer service. This report details the tests performed and interpretation of the results. Recommendations for shelf-life/storage, component quality verification, and post-service examination are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Pressure, Low Temperature Composite Nozzles for Long-Term H2 Dispensing (Final Report)

Final report on evaluation of NanoSonic high pressure hydrogen hoses under CRADA 399. NanoSonic hose liners, fiber winding, and hose end crimp fittings were analyzed for material properties, design, and burst test performance. The hose burst pressures exceeded 100 MPa under -130C sub ambient conditions. Hose crimp fittings were found to have some defects from assembly that impacted burst pressures. The use of digital image correlation provided unique insight to the crimped fitting influence on the composite material and the winding pattern during burst testing.

08 HYDROGEN↗

The NASA Dryden AAR Project: A Flight Test Approach to an Aerial Refueling System

The integration of uninhabited aerial vehicles (UAVs) into controlled airspace has generated a new era of autonomous technologies and challenges. Autonomous aerial refueling would enable UAVs to travel further distances and loiter for extended periods over time-critical targets. The NASA Dryden Flight Research Center recently has completed a flight research project directed at developing a dynamic hose and drogue system model to support the development of an automated aerial refueling system. A systematic dynamic model of the hose and drogue system would include the effects of various influences on the system, such as flight condition, hose and drogue type, tanker type and weight, receiver type, and tanker and receiver maneuvering. Using two NASA F/A-18 aircraft and a conventional hose and drogue aerial refueling store from the Navy, NASA has obtained flight research data that document the response of the hose and drogue system to these effects. Preliminary results, salient trends, and important lessons are presented.

Hansen, Jennifer L.↗

The NASA Dryden Flight Test Approach to an Aerial Refueling System

The integration of uninhabited aerial vehicles (UAVs) into controlled airspace has generated a new era of autonomous technologies and challenges. Autonomous aerial refueling would enable UAVs to travel further distances and loiter for extended periods over time-critical targets. The NASA Dryden Flight Research Center recently has completed a flight research project directed at developing a dynamic hose and drogue system model to support the development of an automated aerial refueling system. A systematic dynamic model of the hose and drogue system would include the effects of various influences on the system, such as flight condition, hose and drogue type, tanker type and weight, receiver type, and tanker and receiver maneuvering. Using two NASA F/A-18 aircraft and a conventional hose and drogue aerial refueling store from the Navy, NASA has obtained flight research data that document the response of the hose and drogue system to these effects. Preliminary results, salient trends, and important lessons are presented

Hansen, Jennifer L.↗

Modified Fittings Enhance Industrial Safety

Kennedy Space Center is not only home to one of the largest buildings in the world - the massive Vehicle Assembly Building - it also hosts a number of one-of-a-kind facilities. The more than 30-mile-long campus has witnessed every launch from the Space Shuttle Launch Pad, as well as many homecomings at the Shuttle Landing Facility. Just as important, the Space Station Processing Facility (SSPF) has seen each element of the International Space Station (ISS) that passes through Kennedy before it goes into orbit. The SSPF is where ISS components are checked, tested, and adjusted before being packed into the Space Shuttle for transport. In an environment like the SSPF - spanning 457,000 square feet of processing areas, operational control rooms, laboratories, logistics areas, and office space - large workstands and equipment used to support the processing of ISS components need to be moved around the facility. One of the devices employed for this task is an air pallet. An air pallet moves on cushions of air instead of wheels. Compressed air inflates the cushions underneath the pallet and is then expelled through exhaust holes. This forms a thin film of air between the cushions and the floor, lifting the platform off the floor and making it easy to move the heavy workstands, equipment, and ISS components. Concerned with the safety of the connections on the pressurized air hoses used for the air pallets, engineers at Kennedy modified an existing commercial cam and groove fitting to control the air supply hose in the event of an accidental release of a pressurized hose. This modification prevented the hose from detaching and, propelled by compressed air, striking workers or equipment. "At the time, these were not available on commercial coupling halves, so NASA made a modification and then put them into use. If a worker were to accidentally try to remove a pressurized hose from the pallet, it no longer rapidly separated, and it safely relieved the pressure," says Paul Schwindt, an engineer at Kennedy who together with Alan Littlefield, also an engineer at Kennedy, designed the modification.

Source record↗

Aerocoat 7 Replacement Coatings

Kennedy Space Center has used Aerocoat 7 (AR-7) to protect stainless-steel flex hoses at Launch Complex (LC-39) and hydraulic lines of the Mobile Launcher Platform (MLP) because it provides excellent corrosion protection in low-temperature applications. The Sovereign Company produced AR-7 exclusively for NASA but discontinued production because the coating released high levels of volatile organic compounds (VOCs) and had a significant environmental impact. The purpose of this project was to select and evaluate potential replacement coatings for AR-7 that would be more environmentally sound. The physical and mechanical properties of commercially available coatings were investigated through the Internet. The ideal coating would be fluid enough to penetrate the outer mesh of a stainless-steel flex hose and coat the inner hose, and flexible enough to withstand the movement of the hose, as well as the expansion and contraction of its metal caused by changes in temperature.

Source record↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

Flow Testing of Corrugated Metal Flexhoses to Evaluate Flow-Induced Vibration and Stiffness

Corrugated metal flexhoses are used to supply fluid routing where straight rigid pipes cannot meet the design requirements due to vibrations, thermal expansion, or motion. These types of hoses are found in a wide range of applications at KSC (Exploration Ground Systems Program in particular) with various fluid commodities such as fuel, oxidizers, coolant, and cryogenics. However, flexibility of design comes at a price: due to increased levels of turbulence generated by the hose geometry, the necessary supply pressure must increase to achieve the same flow rate. Furthermore, the convolutes of the flexhoses interact with the flow field to generate areas of flow separation which leads to a phenomenon known as vortex shedding. When the frequency of vortex shedding couples with the natural frequency of the hose, this can be detrimental and cause premature failure. There are a limited amount of software that can correctly model the coupled fluid structure interactions(FSI) between the solid and fluid physics. This project aims to develop a computer model that can predict Flow-Induced Vibration (FIV) on flexhoses in one of the atypical configurations found in the State-of-the-Art (SOTA) standard for hoses in an angulated state. Our research seeks to extend the literature and expand NASA’s FIV standard. The computational rigor and resources available in the Apollo Era did not allow for flow coupling between fluids and structure interfaces to evaluate FIV of the flexhose. Our team believes that modern techniques and methods of evaluation should be used to reevaluate and extend the database of FIV and stiffness properties of flexhoses to assess the risk of failure. The core performance criteria is a computer model that is able to predict the FIV frequency within 10%.

Jared F. Congiardo↗

Evaluation of Nonmetallic Components in the Hanford Waste Transfer System - 17287

Nonmetallic materials are currently being used in the United States Department of Energy's Hanford Site Tank Farm waste transfer system. These materials include the inner primary hoses in the hose-in-hose transfer lines (HIHTLs), Garlock{sup R} gaskets, ethylene propylene diene monomer (EPDM) O-rings. These materials are exposed to a number of stressors and the synergistic effects are not well understood. Florida International University (FIU) engineers have developed an experimental test loop to determine how the nonmetallic materials react to both individual and simultaneous stressors. The initial phase of testing includes exposure of coupons and components to caustic material at various temperatures for varying lengths of time. The coupons are manufactured from EPDM and Garlock{sup R} sheets and will be used to evaluate changes in material data from baseline data. Components (inner hoses, O-rings and gaskets) will also be used to determine the effects from an environment similar to its operational environment. The test loop utilizes a 25% NAOH solution as the fluid and can accommodate eighteen component assemblies, each consisting of one EPDM HIHTL, EPDM O-ring and Garlock{sup R} gasket. There are three assembly aging sets, one for each temperature (37.78 deg. C, 54.44 deg. C and 79.44 deg. C) and each set contains six assemblies; three for each of the two time periods (6 months and 1 year). Prior to aging, a sample set of the components had baseline mechanical properties tested and a sample set of the coupons had baseline material properties determined as per ASTM standards. After the aging is completed the mechanical and material properties of the aged samples will be measured and compared with the bass-line data to obtain an understanding of the synergistic effects of the two stressors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of temperature and aging duration on ethylene propylene diene monomer (EPDM) nonmetallic components used in caustic liquid waste transfer lines

Nonmetallic materials are used in waste transfer lines at the United States Department of Energy’s Hanford Site Tank Farm in Benton County, Washington, USA. During use, the ethylene propylene diene monomer (EPDM) inner hose of the hose-in-hose transfer lines (HIHTLs) are exposed to β and γ radiation, caustic solutions as well as high temperatures and high pressures. Aging behavior of specimens of EPDM HIHTLs and dog-bone shaped specimens were evaluated by exposing to a solution of 25% sodium hydroxide (NaOH) at 38 °C, 54 °C and 77 °C for 6 and 12-months as well as water only at 77 °C for 12-months. Tensile strength and burst pressure of the specimens were characterized and compared with the unexposed (baseline) specimens. Both the tensile strength of the EPDM material and the burst pressure of the HIHTLs significantly decreased with the higher temperatures and longer exposure times. Analyses using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) of the HIHTLs and the dog-bone specimens were conducted. Our results show that the surface degradation increased with increasing exposure temperature. Penetration of NaOH into the EPDM material also increased with increasing temperature and exposure duration.

36 MATERIALS SCIENCE↗

Effect of solution concentration on ethylene propylene diene monomer (EPDM) nonmetallic components used in caustic liquid waste transfer lines

The hose-in-hose transfer lines (HIHTL) used to transfer waste at the United States Department of Energy’s Hanford Site Tank Farm are fabricated from an ethylene propylene diene monomer (EPDM) synthetic rubber. During waste transport, these hoses are exposed to several stressors including caustic solutions at high temperatures and high pressures, as well as β and γ radiation. The aging behavior of HIHTL and dog-bone shaped EPDM specimens were evaluated by exposure to solutions at 77 °C containing 0.00, 6.25, 12.50, and 25.00 % (v/v) sodium hydroxide (NaOH) for 12-months. After the exposure, the material properties of the specimens were measured and compared to the unaged samples. The material properties evaluated included the tensile strength of the EPDM dog-bone samples and the burst pressure of the HIHTL. Both the tensile strength of the EPDM dog-bone samples and the burst pressure of the HIHTL specimens exposed to the 6.25 % NaOH solution exhibited the most significant deterioration and those exposed to 25.00 % NaOH solution had the least deterioration. Finally, examination of the HIHTL and the EPDM dog-bone specimens with scanning electron microscopy showed that the deterioration for the specimens exposed to 6.25 % NaOH solution were the most severe and the samples exposed to 25.00 % NaOH solution had the least deterioration.

42 ENGINEERING↗

HERO WEC V1 Upgrades - SolidWorks Models (WEC, RO System, and Submersible Pump Housing)

The attached zip files include SolidWorks pack-and-go assemblies of NREL's HERO WEC (hydraulic and electric reverse osmosis wave energy converter), the reverse osmosis (RO) assembly, and the submersible pump assembly that is used to provide flow to the RO assembly in the electric configuration. These 3 models were upgraded in 2023 from their baseline models. The HERO WEC model does not include all aspects of the design (i.e. RO system, electrical enclosure, hose, cable), it only includes the WEC and PTO (power take-off) design. This model supersedes the old MHKDR model submission, linked below. The RO model file includes a SolidWorks (version 2023) pack-and-go assembly of the RO assembly that was used for HERO WEC as it was upgraded in 2023. This model ONLY includes the RO assembly and not the WEC, hoses, etc. The submersible pump enclosure model includes a SolidWorks (version 2023) pack-and-go assembly of the submersible pump assembly that is used to provide flow to the RO assembly in the electric configuration HERO WECas it was upgraded in 2023. This model ONLY includes the submersible pump assembly and not the WEC, RO system, hoses, etc. This work has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

BENCH SCALE SALTSTONE PROCESS DEVELOPMENT MIXING STUDY

The Savannah River National Laboratory (SRNL) was requested to develop a bench scale test facility, using a mixer, transfer pump, and transfer line to determine the impact of conveying the grout through the transfer lines to the vault on grout properties. Bench scale testing focused on the effect the transfer line has on the rheological property of the grout as it was processed through the transfer line. Rheological and other physical properties of grout samples were obtained prior to and after pumping through a transfer line. The Bench Scale Mixing Rig (BSMR) consisted of two mixing tanks, grout feed tank, transfer pump and transfer hose. The mixing tanks were used to batch the grout which was then transferred into the grout feed tank. The contents of the feed tank were then pumped through the transfer line (hose) using a progressive cavity pump. The grout flow rate and pump discharge pressure were monitored. Four sampling stations were located along the length of the transfer line at the 5, 105 and 205 feet past the transfer pump and at 305 feet, the discharge of the hose. Scaling between the full scale piping at Saltstone to bench scale testing at SRNL was performed by maintaining the same shear rate and total shear at the wall of the transfer line. The results of scaling down resulted in a shorter transfer line, a lower average velocity, the same transfer time and similar pressure drops. The condition of flow in the bench scale transfer line is laminar. The flow in the full scale pipe is in the transition region, but is more laminar than turbulent. The resulting plug in laminar flow in the bench scale results in a region of no-mixing. Hence mixing, or shearing, at the bench scale should be less than that observed in the full scale, where this plug is non existent due to the turbulent flow. The bench scale tests should be considered to be conservative due to the highly laminar condition of flow that exists. Two BSMR runs were performed. In both cases, wall shearing was shown to reduce the rheological properties of the grout as it was processed through the transfer line. Samples taken at the static feed tank showed that gelling impacted the rheological properties of the grout before it was fed into the pump and transfer line. A comparison of the rheological properties of samples taken at the feed tank and transfer line discharge indicated shearing of the grout was occurring in the transfer line. Bench scale testing of different mixing methods with three different salt solutions showed that method of mixing influences the rheological properties of the grouts. The paddle blade mixing method of the salt solution used for the BMSR testing provided comparable rheological properties of the grout prepared in the BMSR after 14 minutes of processing, B3. The paddle blade mixing method can be used to represent BMSR results and mixing time can be adjusted to represent larger scale mixing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Teflon-packed flexible joint

Teflon-packed flexible joint separates the movement of the shaker from the liquid nitrogen hose during the ground testing of cryogenic zero-g equipment. The joint allows the hose to lie on the floor in a stationary position as the shaker moves back and forth, thus, the hose is not subject to violent motion.

Belmont, G. E.↗

Clamp Restrains Pressure Line

Safety restraint protects people and property if a high-pressure fitting fails. As long as pressure line remains attached at the fitting, clamp exerts essentially no force on hose. If fitting fails, force of fluid leaving free end of hose causes the cam on the clamp to compress hose with a positive locking action.

Aliberti, J. A.↗