Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYGROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Airborne and Ground-Based Measurements Using a High-Performance Raman Lidar

A high-performance Raman lidar operating in the UV portion of the spectrum has been used to acquire, for the first time using a single lidar, simultaneous airborne profiles of the water vapor mixing ratio, aerosol backscatter, aerosol extinction, aerosol depolarization and research mode measurements of cloud liquid water, cloud droplet radius, and number density. The Raman Airborne Spectroscopic Lidar (RASL) system was installed in a Beechcraft King Air B200 aircraft and was flown over the mid-Atlantic United States during July August 2007 at altitudes ranging between 5 and 8 km. During these flights, despite suboptimal laser performance and subaperture use of the telescope, all RASL measurement expectations were met, except that of aerosol extinction. Following the Water Vapor Validation Experiment Satellite/Sondes (WAVES_2007) field campaign in the summer of 2007, RASL was installed in a mobile trailer for groundbased use during the Measurements of Humidity and Validation Experiment (MOHAVE-II) field campaign held during October 2007 at the Jet Propulsion Laboratory s Table Mountain Facility in southern California. This ground-based configuration of the lidar hardware is called Atmospheric Lidar for Validation, Interagency Collaboration and Education (ALVICE). During theMOHAVE-II field campaign, during which only nighttime measurements were made, ALVICE demonstrated significant sensitivity to lower-stratospheric water vapor. Numerical simulation and comparisons with a cryogenic frost-point hygrometer are used to demonstrate that a system with the performance characteristics of RASL ALVICE should indeed be able to quantify water vapor well into the lower stratosphere with extended averaging from an elevated location like Table Mountain. The same design considerations that optimize Raman lidar for airborne use on a small research aircraft are, therefore, shown to yield significant dividends in the quantification of lower-stratospheric water vapor. The MOHAVE-II measurements, along with numerical simulation, were used to determine that the likely reason for the suboptimal airborne aerosol extinction performance during theWAVES_2007 campaign was amisaligned interference filter. With full laser power and a properly tuned interference filter,RASL is shown to be capable ofmeasuring themain water vapor and aerosol parameters with temporal resolutions of between 2 and 45 s and spatial resolutions ranging from 30 to 330 m from a flight altitude of 8 km with precision of generally less than 10%, providing performance that is competitive with some airborne Differential Absorption Lidar (DIAL) water vapor and High Spectral Resolution Lidar (HSRL) aerosol instruments. The use of diode-pumped laser technology would improve the performance of an airborne Raman lidar and permit additional instrumentation to be carried on board a small research aircraft. The combined airborne and ground-based measurements presented here demonstrate a level of versatility in Raman lidar that may be impossible to duplicate with any other single lidar technique.

Whiteman, David N.↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Detailed Structure of the Tropical Upper Troposphere and Lower Stratosphere as Revealed by Balloon Sonde Observations of Water Vapor, Ozone, Temperature, and Winds During the NASA TCSP and TC4 Campaigns

We report on balloon sonde measurements of water vapor and ozone using the cryogenic frost point hygrometer and electrochemical concentration cell ozonesondes made at Alajuela, Costa Rica (10.0 N, 84.2 W) during two NASA airborne campaigns: the Tropical Convective Systems and Processes (TCSP) mission in July 2005 and the Tropical Composition, Clouds, and Climate Coupling Experiment (TC4), July - August 2007. In both campaigns we found an upper troposphere that was frequently supersaturated but no evidence that deep convection had reached the tropopause. The balloon sondes were complemented by campaigns of 4 times daily high-resolution radiosondes from mid-June through mid-August in both years. The radiosonde data reveal vertically propagating equatorial waves that caused a large increase in the variability of temperature in the tropical tropopause layer (TTL). These waves episodically produced cold point tropopauses (CPTs) above 18 km, yet in neither campaign was saturation observed above approx 380 K or 17 km. The averages of the water vapor minima below this level were 5.2 ppmv in TCSP and 4.8 ppmv in TC4, and the individual profile minima all lay at or above approx 360 K. The average minima in this 360 C380 K layer provide a better estimate of the effective stratospheric entry value than the average mixing ratio at the CPT. We refer to this upper portion of the TTL as the tropopause saturation layer and consider it to be the locus of the final dehydration of nascent stratospheric air. As such, it is the local equivalent to the tape head of the water vapor tape recorder.

Selkirk, Henry B.↗

The Relation Between Atmospheric Humidity and Temperature Trends for Stratospheric Water

We analyze the relation between atmospheric temperature and water vapor-a fundamental component of the global climate system-for stratospheric water vapor (SWV). We compare measurements of SWV (and methane where available) over the period 1980-2011 from NOAA balloon-borne frostpoint hygrometer (NOAA-FPH), SAGE II, Halogen Occultation Experiment (HALOE), Microwave Limb Sounder (MLS)/Aura, and Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) to model predictions based on troposphere-to-stratosphere transport from ERA-Interim, and temperatures from ERA-Interim, Modern Era Retrospective-Analysis (MERRA), Climate Forecast System Reanalysis (CFSR), Radiosonde Atmospheric Temperature Products for Assessing Climate (RATPAC), HadAT2, and RICHv1.5. All model predictions are dry biased. The interannual anomalies of the model predictions show periods of fairly regular oscillations, alternating with more quiescent periods and a few large-amplitude oscillations. They all agree well (correlation coefficients 0.9 and larger) with observations for higherfrequency variations (periods up to 2-3 years). Differences between SWV observations, and temperature data, respectively, render analysis of the model minus observation residual difficult. However, we find fairly well-defined periods of drifts in the residuals. For the 1980s, model predictions differ most, and only the calculation with ERA-Interim temperatures is roughly within observational uncertainties. All model predictions show a drying relative to HALOE in the 1990s, followed by a moistening in the early 2000s. Drifts to NOAA-FPH are similar (but stronger), whereas no drift is present against SAGE II. As a result, the model calculations have a less pronounced drop in SWV in 2000 than HALOE. From the mid-2000s onward, models and observations agree reasonably, and some differences can be traced to problems in the temperature data. These results indicate that both SWV and temperature data may still suffer from artifacts that need to be resolved in order to answer the question whether the large-scale flow and temperature field is sufficient to explain water entering the stratosphere.

Fueglistaler, S.↗

Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofısica de Andalucıa (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

MIPAS validation↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

The Phoenix TECP Relative Humidity Sensor: Revised Results

The original calibration function of the RH sensor on the Phoenix mission's Thermal and Electrical Conductivity Sensor (TECP), has been revised to correct the erroneously-published original calibration equation, to demonstrate the value of this unique data set, and to improve characterization of H2O exchange between the martian regolith and atmosphere. TECP returned two data streams, the temperature of the electronics analog board (Tb) and the digital 12-bit output of the RH sensor (DN), both of which are required to uniquely specify the H2O abundance. Because the original flight instrument calibration was performed against a pair of hygrometers that measured frost point (Tf), the revised calibration equation is also cast in terms of frost point. The choice of functional form for the calibration function is minimally constrained. A series of profiles across the calibration data cloud at constant DN and Tb does not reveal any evidence of a complex functional form. Therefore, a series of polynomials in both DN and Tb was investigated, along with several non-linear functions of DN and Tb.

Phoenix mission↗

Aircraft Measurements of BrO, IO, Glyoxal, NO2, H2O, O2-O2 and Aerosol Extinction Profiles in the Tropics: Comparison with Aircraft-/Ship-Based in Situ and Lidar Measurements

Tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO), iodine monoxide (IO) and small oxygenated hydrocarbons like glyoxal (CHOCHO) in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO2), water vapor (H2O) and O2-O2 collision complexes (O4/ were measured by the University of Colorado Airborne Multi-AXis Differential Optical Absorption Spectroscopy (CU AMAXDOAS) instrument, aerosol extinction by high spectral resolution lidar (HSRL), in situ aerosol size distributions by an ultra high sensitivity aerosol spectrometer (UHSAS) and in situ H2O by vertical-cavity surface-emitting laser (VCSEL) hygrometer. Data are presented from two research flights (RF12, RF17) aboard the National Science Foundation/ National Center for Atmospheric Research Gulfstream V aircraft over the tropical Eastern Pacific Ocean (tEPO) as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO) project (January/February 2012). We assess the accuracy of O4 slant column density (SCD) measurements in the presence and absence of aerosols. Our O4-inferred aerosol extinction profiles at 477 nm agree within 6% with HSRL in the boundary layer and closely resemble the renormalized profile shape of Mie calculations constrained by UHSAS at low (sub-Rayleigh) aerosol extinction in the free troposphere. CU AMAX-DOAS provides a flexible choice of geometry, which we exploit to minimize the SCD in the reference spectrum (SCDREF, maximize signal-to-noise ratio) and to test the robustness of BrO, IO and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01) and provides independent validation data from ship-based in situ cavity-enhanced DOAS and MAX-DOAS. Inside the marine boundary layer (MBL) no BrO was detected (smaller than 0.5 pptv), and 0.2-0.55 pptv IO and 32-36 pptv glyoxal were observed. The near-surface concentrations agree within 30% (IO) and 10% (glyoxal) between ship and air-craft. The BrO concentration strongly increased with altitude to 3.0 pptv at 14.5 km (RF12, 9.1 to 8.6 deg N; 101.2 to 97.4 deg W). At 14.5 km, 5-10 pptv NO2 agree with model predictions and demonstrate good control over separating tropospheric from stratospheric absorbers (NO2 and BrO). Our profile retrievals have 12-20 degrees of freedom (DoF) and up to 500m vertical resolution. The tropospheric BrO vertical column density (VCD) was 1.5 x 10(exp 13) molec cm(exp -2) (RF12) and at least 0.5 x 10(exp 13) molec cm(exp -2) (RF17, 0- 10 km, lower limit). Tropospheric IO VCDs correspond to 2.1 x 10(exp 12) molec cm(exp -2) (RF12) and 2.5 x 10(exp 12) molec cm(exp -2) (RF17) and glyoxal VCDs of 2.6 x 10(exp 14) molec cm(exp -2) (RF12) and 2.7 x 10(exp 14) molec cm(exp -2) (RF17). Surprisingly, essentially all BrO as well as the dominant IO and glyoxal VCD fraction was located above 2 km (IO: 58 plus or minus 5 %, 0.1-0.2 pptv; glyoxal: 52 plus or minus 5 %, 3-20 pptv). To our knowledge there are no previous vertically resolved measurements of BrO and glyoxal from aircraft in the tropical free troposphere. The atmospheric implications are briefly discussed. Future studies are necessary to better understand the sources and impacts of free tropospheric halogens and oxygenated hydrocarbons on tropospheric ozone, aerosols, mercury oxidation and the oxidation capacity of the atmosphere.

Volkamer, R.↗

A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

Phoenix Thermal and Electrical Conductivity Sensor↗

Ticosonde CFH at Costa Rica: A Seasonal Climatology of Tropical UT-LS Water Vapor and Inter-Comparisons with MLS and CALIPSO

Balloon sonde measurements of tropical water vapor using the Cryogenic Frostpoint Hygrometer were initiated in Costa Rica in July 2005 and have continued to the present day. Over the nine years through July 2014, the Ticosonde program has launched 174 CFH payloads, representing the longest-running and most extensive single-site balloon dataset for tropical water vapor. In this presentation we present a seasonal climatology for water vapor and ozone at Costa Rica and examine the frequency of upper tropospheric supersaturation with comparisons to cloud fraction and cloud ice water content observations from the Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) on the CALIPSO mission. We then make a critical comparison of these data to water vapor measurements from the MLS instrument on board Aura in light of recently published work for other sites. Finally, we examine time series of 2-km altitude averages in the upper troposphere-lower stratosphere at Costa Rica in light of anomalies and trends seen in various large-scale indices of tropical water vapor.

water vapor↗

SEACIONS During the 2012 Asian Monsoon: A Strategic Approach to Determining Convective Impacts on Tropospheric Ozone and TTL Gravity Waves

Purpose of making ozone and water vapor profiles measurements in SEAC4RS is to give consistent coverage of the vertical structure at fixed sites to (1) complement 2 campaign aircraft sampling; (2) ground-truth satellite measurements of H O and ozone; (3) provide profiles for model evaluation; (4) study processes responsible for day-to-day variability at each site. Revised objective for 2013, due to cancellation of the 2012 and 2013 plans to operate in Southeast Asia: rapidly re-configure the original "SEACIONS," Southeast Asian Consortium for Intensive Ozonesonde Network Study, to a SouthEast American plan (SEACIONS) for collecting daily ozonesonde data during DC-8 and ER-2 flights throughout the southeastern US. As in previous IONS (2004, 2006, 2008), students were trained at St Louis, Tallahassee, Houston, Penn State, Huntsville, Socorro. Images of the soundings and related flight-planning products were posted each day at NASA and Penn State (PSU) websites. With the aircraft based at Ellington Field (Houston), water CFH (cryogenic frost-point hygrometer) sondes in addition to ozonesondes, were to be taken launched at that site.

Thompson, Anne M.↗

Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

Diskin, Glenn S.↗

Mars Ecopoiesis Testbed

Mars surface conditions where liquid water is absent were simulated for the purposes of laboratory research. A pressure-temperature (P-T) profile was maintained in which no combination of pressure or temperature corresponds to the liquid region of the water phase diagram. The triple point of pure water occurs at T = 0.1oC and P(H2O) = 6.01 mbar; therefore all temperatures and pressures must be kept below these values, respectively. A 35-day test was performed in a commercial planetary simulation system (Techshot, Inc., Greenville, IN) in which the minimum night-time temperature was -80oC, the maximum daytime temperature was +26oC, the simulated day-night light cycle in earth hours was 12-on and 12-off, and the total pressure of the pure CO2 atmosphere was maintained below 11 mbar. Any water present was allowed to equilibrate with the changing temperature and pressure. The gas phase was sampled into a CR1-A condensation-mirror low-pressure hygrometer, which uses liquid nitrogen (down to 77oK) to determine the dew point (Buck Technologies, Boulder, CO). Dew point was measured once every hour and recorded on a data logger, along with the varying temperature in the chamber, from which the partial pressure of water was calculated. The resulting calculated daily cycles were tracked on the water P-T diagram, and no points were found to fall within the liquid-phase region of the diagram. It is concluded that there was no liquid water present throughout the test except during the initial pump-down period when aqueous specimens were introduced on the first day (less than 1 hour). Mars regolith simulant was present during this test, and further investigation is needed to determine whether liquid water could have been present or absent in the regolith in the form of brine. Biological samples consisting of Cyanobacteria: Anabena sp., Chroococcidiopsis CCMEE171, Plectonema boryanum; Eubacteria: Bacillus subtilis, Pseudomonas aeruginosa, and Eukaryota: Chlorella ellipsoidia were maintained in the simulator under the above-described conditions. The exposed specimens were tested for intracellular esterase activity, chlorophyll content (where appropriate) and reproductive survival. All tests yielded low-level positive results in all cases. In parallel to these terrestrial studies a planned design study was undertaken for the proposed test bed. Design requirements include compact assembly for transport and installation on the planetary surface (multiple units per mission would be expected), protective internal package for the release of organisms, a means of atmosphere exchange, access to sunlight, a means of penetrating the planetary surface, and most importantly a means of acquiring regolith while meeting the requirements of planetary protection. In consultation with advisers a design was created, and a large-scale mock-up of this design was fabricated by additive manufacturing at Techshot, Inc. with moving parts that simulated the components of the design. The mock-up assembly has been demonstrated to interested parties. A means of detecting live metabolism will also be included in the test bed. Several options were reviewed, and it is concluded that, by the time the ecopoiesis test bed is ready for testing the optimum instrument will be the equivalent of a hand-held mass spectrometer for metabolic gas analysis. This will maximize versatility and reveal much more information than could a detector of a single product (such as molecular oxygen), and the

Ecopoiesis↗

TPSAS-NF1676L-32936-DND

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument, installed on the International Space Station (ISS), has completed over a year of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument, scanning the light from the sun and moon, through the limb of the Earth’s atmosphere. It was launched in February 2017 and provides data from June 2017 to the present. It continues SAGE's legacy of ozone, aerosol and water vapor profile measurements and extends the lengthy records for monitoring constituents important for understanding stratospheric ozone trends. This presentation shows the preliminary validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles with those of NOAA ESRL/GMD and NIWA mission-funded ozonesondes and frost point hygrometers, and comparisons with other correlative data.

Susan Kizer↗

TPSAS-NF1676L-30150-DND

Validation of science data products from the Stratospheric Aerosol and Gas Experiment (SAGE) III, installed on the International Space Station (ISS) in March 2017, requires intercomparison with validated data sources. The SAGE III/ISS mission is actively utilizing in-situ profile measurements from balloon packages, consisting of a standard meteorological radiosonde, ozonesonde, and frost-point hygrometer, that were launched coincident with SAGE III/ISS overpass opportunities. Some packages have included an aerosol sonde. This provides regional correlations of ozone, water vapor and aerosol extinction between the in-situ measurement data and the SAGE III/ISS profile products. In addition, ground-based LIDAR measurements and aircraft-based measurements of ozone, water vapor, aerosol extinction and nitrogen dioxide will provide additional validation data for correlation with the SAGE III/ISS data products. Initial results of the mission directed validation program will be presented. When possible, operation and launch times were modified to improve the temporal and spatial coincidence between the measurements. Results and progress utilizing LIDAR and balloon-borne aerosol observations are discussed herein, while intercomparisons that make use of ozone sondes is are presented in the companion poster by Kizer et al.

Travis Knepp↗

Airborne High Spectral Resolution Lidar-2 Measurements of Enhanced Depolarization in Marine Aerosols

Airborne NASA Langley Research Center (LaRC) High Spectral Resolution Lidar-2 (HSRL-2) measurements acquired during the recent NASA EVS-3 Aerosol Cloud Meteorology Interactions over the Western Atlantic Experiment (ACTIVATE) revealed enhanced particulate linear depolarization associated with aerosols within the marine boundary layer. These HSRL-2 observations were acquired off the east coast of the United States in February and March 2020 when this lidar was deployed on the NASA LaRC UC-12 aircraft. HSRL-2 measured profiles of aerosol backscattering, extinction,and depolarization at 355 and 532nm and aerosol backscattering and depolarization at 1064nm. Typically HSRL-2 measures low (<5%) linear particulate depolarization associated with marine sea salt aerosols. However, during several ACTIVATE flights, particularly those that occurred with outbreaks of cold, dry air, linear particulate depolarization exceeded 15-20% (532nm) for aerosols within a few hundred meters above the surface. These high values indicated that these particles were nonspherical. Elevated depolarization values were also observed at 355 and 1064 nm. HSRL-2 measured aerosol extinction/backscatter ratio (“lidar ratio”) values around 20-25 sr (355 and 532 nm) that are typically associated with sea salt particles. Coincident measurements of relative humidity from dropsondes released from the UC-12and in situ Diode Laser Hygrometer (DLH) measurements flown on the NASA HU-25 aircraft showed that highest depolarization values of these nonspherical particles were found when the relative humidity (RH)was below 50-60%.These lidar observations of elevated depolarization associated with sea salt aerosol are consistent with previous lidar measurements of sea salt aerosols in dry conditions. We discuss these HSRL-2 measurements also in the context of coincident airborne in situ measurements of particle size and composition acquired on the HU-25 aircraft. We also found that CALIOP satellite measurements observed elevated depolarization during some similar cold air outbreaks. In such cases, the operational CALIOP algorithms attributed the elevated depolarization to nonspherical dust particles rather than the more likely scenario of nonspherical sea salt particles associated with low RH.

aerosols↗

SAGE III/ISS Validation of Ozone and Water Vapor V5.2 Data Using Collocated Balloon-Borne Measurements

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed nearly four years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles from the newly released v5.2 science product with those of balloon launched ozonesonde and frost point hygrometer measurements and satellite data from the Microwave Limb Sounder.

S Kizer↗

Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS): Validation of Ozone Using In-situ Measurements

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed four years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone vertical profiles from the newly released v5.2 science product with those of balloon launched ozonesonde and frost point hygrometer measurements, LIDAR, and satellite data from the Microwave Limb Sounder.

stratospheric ozone↗