Search NASASearch

SEARCH · Search NASA

Results for “Hand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Circuit For Control Of Electromechanical Prosthetic Hand

Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

Bozeman, Richard J., Jr.

Space Shuttle Reusable Solid Rocket Motor (RSRM) Hand Cleaning Solvent Replacement at Kennedy Space Center (KSC)

At Kennedy Space Center (KSC), Thiokol Corporation provides the engineering to assemble and prepare the Space Shuttle Reusable Solid Rocket Motor (RSRM) for launch. This requires hand cleaning over 86 surfaces including metals, adhesives, rubber and electrical insulations, various painted surfaces and thermal protective materials. Due to the phase-out of certain ozone depleting chemical (ODC) solvents, all RSRM hand wipe operations being performed at KSC using l,l,1-trichloroethane (TCA) were eliminated. This presentation summarizes the approach used and the data gathered in the effort to eliminate TCA from KSC hand wipe operations.

Keen, Jill M.

Design of the NASA Robonaut Hand

The design of a highly anthropomorphic human scale robot hand for space based operations is described. This five finger hand combined with its integrated wrist and forearm has fourteen independent degrees of freedom. The device approximates very well the kinematics and required strength of an astronaut's hand when operating through a pressurized space suit glove. The mechanisms used to meet these requirements are explained in detail along with the design philosophy behind them. Integration experiences reveal the challenges associated with obtaining the required capabilities within the desired size. The initial finger control strategy is presented along with examples of obtainable grasps.

Lovchik, Chris S.

Compact Dexterous Robotic Hand

A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.

Lovchik, Christopher Scott

Robotic Hand

The Omni-Hand was developed by Ross-Hime Designs, Inc. for Marshall Space Flight Center (MSFC) under a Small Business Innovation Research (SBIR) contract. The multiple digit hand has an opposable thumb and a flexible wrist. Electric muscles called Minnacs power wrist joints and the interchangeable digits. Two hands have been delivered to NASA for evaluation for potential use on space missions and the unit is commercially available for applications like hazardous materials handling and manufacturing automation. Previous SBIR contracts resulted in the Omni-Wrist and Omni-Wrist II robotic systems, which are commercially available for spray painting, sealing, ultrasonic testing, as well as other uses.

Source record

Identification of a new EF-hand superfamily member from Trypanosoma brucei

We identified several open reading frames between the regions encoding calmodulin and ubiquitin-EP52/1 in the genome of Trypanosoma brucei. One of these, EFH5, encodes a protein 192 amino acids long. The EFH5 transcript is present in poly(A)+ mRNA and is present at similar levels in the mammalian bloodstream form and the insect procyclic form. EFH5 contains four EF-hand homolog domains, two of which are inferred to bind Ca2+ ions. We expressed EFH5 as a fusion protein in Escherichia coli and demonstrated calcium-binding activity of the fusion protein using the 45Ca-overlay technique. The function of EFH5 remains unknown; however, as the fourth EF-hand homolog identified in trypanosomes, it attests to the broad range of functions assumed by calcium functioning as a second messenger. EFH5, which is most closely related to LAV1-2 from Physarum, represents a distinct subfamily among the EF-hand-containing proteins.

Non-NASA Center

3 degree of freedom hand controller

A hand controller which includes a hand grip having therein a gimble mechanism for allowing rotatory motion about three axes which intersect in the interior of the hand grip and from which motion transmitting members allow the motions about the three axes to be transmitted to remote pick off devices and also along which force feedback signals may be fedback to the gimble structure to provide the correct feel for the grip.

Menahem, Israel

Computer implemented method, and apparatus for controlling a hand-held tool

The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.

Wagner, Kenneth William

Artificial dexterous hand

An artificial dexterous hand is provided for grasping and manipulating objects. The hand includes left and right thumbs that are operatively connected to an engagement assembly which causes movement of the left and right thumbs. The left thumb has a left thumb base and is movable about three separate first left thumb axes which run through the left thumb base. Correspondingly, the right thumb has a right thumb base and is movable about three separate first right thumb axes which run through the right thumb base. The engagement assembly has a gear assembly which is operatively connected to a motor assembly. Upon actuation by the motor assembly, the gear assembly causes movement of the left and right thumbs about the first left thumb axes and first right thumb axes respectively. The hand can also have a center finger which is operatively connected to the engagement assembly and which is interposed between the left and right thumbs. The finger has a finger base and is movable about two separate first finger axes running through the finger base. Therefore, upon actuation by the motor assembly, the gear assembly will also cause movement of the finger about the first finger axes.

Lee, Sukhan

A Combination of Traditional and Novel Methods Used to Evaluate the Impact of an EVA Glove on Hand Performance

The gloved hand is an astronaut s primary means of interacting with the environment, so performance on an EVA is strongly impacted by any restrictions imposed by the glove. As a result, these restrictions have been the subject of study for decades. However, previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Instead, studies have tended to focus on the dexterity, strength and functional performance of the gloved hand. Therefore, it has been difficult to judge the impact of each type of restriction on the glove s overall capability. The lack of basic information on glove mobility in particular, is related to the difficulty in instrumenting a gloved hand to allow an accurate evaluation. However, the current study aims at developing novel technological capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve upon their current designs. A series of evaluations were performed in ungloved, unpressurized and pressurized (4.3 psi) conditions, to allow a comparison across pressures and to the baseline barehanded condition. In addition, a subset of the testing was also performed with the Thermal Micrometeoroid Garment (TMG) removed. This test case in particular provided some interesting insight into how much of an impact the TMG has on gloved mobility -- in some cases, as much as pressurization of the glove. Previous rule-of-thumb estimates had assumed that the TMG would have a much lower impact on mobility, while these results suggest that an improvement in the TMG could actually have a significant impact on glove performance. Similarly, tactility testing illustrated the impact of glove pressurization on tactility and provided insight on the design of interfaces to the glove. The metrics described in this paper have been used to benchmark the Phase VI EVA glove and to develop requirements for the next generation glove for the Constellation program.

Rajulu, Sudhakar

Gender-related Changes in Dorsal Hand and Foot Vein Function Following 60 Days of Head Down Bed Rest

It is well known that female astronauts are more likely to experience post-flight orthostatic hypotension and presyncope compared to male astronauts. It has been suggested that the disproportionally higher incidence of presyncope (83% of female vs. 20% male crewmembers) may be due to sex-related differences in vascular function between the upper and lower limbs. However, much of this evidence is specific to changes in resistance vessels. Given that more than 70% of the circulating blood volume resides in compliance vessels, it is conceivable that even small changes in venous function may contribute to post-flight orthostatic hypotension. In spite of this, little is currently known regarding the influence of microgravity exposure on venous function between males and females. PURPOSE: To determine the influence of 60 days of HDBR on dorsal foot and hand vein function between healthy males (M) and females (F). METHODS: Using 2-D ultrasound, dorsal hand and foot vein diameter responses to intravenous infusions phenylephrine (PE), acetylcholine (ACh), and nitroglycerine (NTG) were determined in 26 adults; 10 females (age:37 +/- 2 yr ) and 16 males (age:34 +/- 2 yr ). Changes in venous function were calculated as the difference between diameter at baseline and following each venoactive drug. Differences in venous function between limb and sexes across HDBR were determined using mixed-effects linear regression. RESULTS: In response to 60 days of HDBR, the change in venousconstrictor response to PE in the dorsal hand veins was not significantly different between M and F. Interestingly, the change in constrictor response in the dorsal foot veins (compared to pre HDBR) was approximately 30% greater in the F, whereas the constrictor response was approximately 45% less in the M (p=0.026). HDBR had no influence on the change in dilator response to ACh, or NTG between M and F and between vascular beds. CONCLUSION: These results demonstrate that 60 days of HDBR contributes to sex-related differences in venous function. Importantly, the changes are specific to dorsal foot veins and do not appear to be related to changes in endothelial or smooth muscle function. Previous data from our laboratory indicate that females have an impaired sympathetic response following HDBR. However, the results from the current investigation imply that F maintain the ability to respond to sympathetic stimulation but may not be able to adequately activate a proper response following HDBR.

Westby, Christian M.

Distributing Data from Desktop to Hand-Held Computers

A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to

Elmore, Jason L.

Using Arm and Hand Gestures to Command Robots during Stealth Operations

Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

stealth operations

Hand-Based Biometric Analysis

Hand-based biometric analysis systems and techniques provide robust hand-based identification and verification. An image of a hand is obtained, which is then segmented into a palm region and separate finger regions. Acquisition of the image is performed without requiring particular orientation or placement restrictions. Segmentation is performed without the use of reference points on the images. Each segment is analyzed by calculating a set of Zernike moment descriptors for the segment. The feature parameters thus obtained are then fused and compared to stored sets of descriptors in enrollment templates to arrive at an identity decision. By using Zernike moments, and through additional manipulation, the biometric analysis is invariant to rotation, scale, or translation or an input image. Additionally, the analysis uses re-use of commonly seen terms in Zernike calculations to achieve additional efficiencies over traditional Zernike moment calculation.

Bebis, George

Feasibility Assessment of an EVA Glove Sensing Platform to Evaluate Potential Hand Injury Risk Factors

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.

Reid, Christopher R.

Hand-Based Biometric Analysis

Hand-based biometric analysis systems and techniques are described which provide robust hand-based identification and verification. An image of a hand is obtained, which is then segmented into a palm region and separate finger regions. Acquisition of the image is performed without requiring particular orientation or placement restrictions. Segmentation is performed without the use of reference points on the images. Each segment is analyzed by calculating a set of Zernike moment descriptors for the segment. The feature parameters thus obtained are then fused and compared to stored sets of descriptors in enrollment templates to arrive at an identity decision. By using Zernike moments, and through additional manipulation, the biometric analysis is invariant to rotation, scale, or translation or an in put image. Additionally, the analysis utilizes re-use of commonly-seen terms in Zernike calculations to achieve additional efficiencies over traditional Zernike moment calculation.

Bebis, George

Long-term reliability of hand-soldering M55365 Ta capacitors

This is a continuation of the report “Effects of Hand Soldering MIL-PRF-55365 Tantalum Capacitors,” which discusses the parametric effects of convection reflow soldering, JPL standard hand soldering, and optimized hand soldering on solid tantalum capacitors. The current focus is determining the long-term reliability effects of the various soldering techniques. Unfortunately, the 100-piece sample size chosen for the highly accelerated life tests was too small to reliably determine the effects of the different soldering techniques on the lifespan of the parts. In hindsight, this likely could have been predicted based on the large alphas and small betas of the Weibull failure distributions discovered during the scouting trials. Now that the effects of inadequate sample size are better understood, an opportunity exists to not only discover whether there are real differences in the reliability associated with the various soldering techniques, but also the potential to discover the voltage acceleration model and the temperature acceleration effect for these capacitors. It is recommended that the testing be repeated with a more appropriate sample size to capture this useful information.

Spence, Penelope

Thinking Inside the Box: A Hands-On Student Activity for Building a Contamination Containment Glovebox to Encourage Problem Solving in a Collaborative Environment

Contamination containment gloveboxes are sealed containers where operators outside the glovebox can safely manipulate hazardous or contamination-sensitive materials inside the glovebox through glove ports on the container. Containment gloveboxes are used in the space industry to study sample materials returned from space such as lunar, asteroid, and comet materials, to manufacture sensitive instruments and space ight hardware, and to perform contamination-sensitive experiments. A hands-on activity has been developed by contamination control engineer and STEM education experts as part of the Virginia Earth System Science Scholars (VESSS) summer academy program to teach high school students about gloveboxes and about problem solving in a collaborative environment. In this activity, student teams are given a list of common household materials (e.g. plastic bags, plastic straws, aluminum foil, tape, disposable gloves, etc.) for building their own glovebox. Students work together to sketch and design their glovebox before being provided a kit of materials, which they must purchase along with any extra materials with a mock team budget. They are given 30 minutes to build their glovebox, however, they do not know what will be placed inside the glovebox or what operations they will need to perform within the glovebox. At the end of the build time, teams are given a small, sealed paper envelope which they place in the glovebox. Each team selects a team member to be designated as the operator, and the operator places their hands in the gloves of the glovebox. The operator uses their gloves to open the envelope in the glovebox, and they discover they have 20 minutes to assemble a jigsaw puzzle. However, the puzzle is \contaminated" with talcum powder. After the 20 minute time period, teams are judged on how well they completed and cleaned the contaminated puzzle. In a post-activity debrief, teams discuss lessons learned such as how the actual built box di ered from the sketched design, the challenge of managing a budget for materials, how the team dealt with surprises, and if their glovebox allowed enough room for the operator to perform the task. This activity has been part of the VESSS summer academy since 2016, and teaches students teamwork, creativity, hands-on experimentation, communication, and reasoning skills. In a demonstration at IAC, a volunteer from the audience will be chosen to assemble a glovebox during the presentation using the same kit of materials and will demonstrate handling puzzle pieces in the completed glovebox.

Elaine Seasly