Simulation of 100-300 GHz solid-state harmonic sources

Accurate and efficient simulations of the large-signal time-dependent characteristics of second-harmonic Transferred Electron Oscillators (TEO's) and Heterostructure Barrier Varactor (HBV) frequency triplers have been obtained. This is accomplished by using a novel and efficient harmonic-balance circuit analysis technique which facilitates the integration of physics-based hydrodynamic device simulators. The integrated hydrodynamic device/harmonic-balance circuit simulators allow TEO and HBV circuits to be co-designed from both a device and a circuit point of view. Comparisons have been made with published experimental data for both TEO's and HBV's. For TEO's, excellent correlation has been obtained at 140 GHz and 188 GHz in second-harmonic operation. Excellent correlation has also been obtained for HBV frequency triplers operating near 200 GHz. For HBV's, both a lumped quasi-static equivalent circuit model and the hydrodynamic device simulator have been linked to the harmonic-balance circuit simulator. This comparison illustrates the importance of representing active devices with physics-based numerical device models rather than analytical device models.

NONLINEAR CIRCUITS↗

Large-scale harmonic balance simulations with Krylov subspace and preconditioner recycling

The multi-harmonic balance method combined with numerical continuation provides an efficient framework to compute a family of time-periodic solutions, or response curves, for large-scale, nonlinear mechanical systems. The predictor and corrector steps repeatedly solve a sequence of linear systems that scale by the model size and number of harmonics in the assumed Fourier series approximation. In this paper, a novel Newton–Krylov iterative method is embedded within the multi-harmonic balance and continuation algorithm to efficiently compute the approximate solutions from the sequence of linear systems that arise during the prediction and correction steps. Further, the method recycles, or reuses, both the preconditioner and the Krylov subspace generated by previous linear systems in the solution sequence. A delayed frequency preconditioner refactorizes the preconditioner only when the performance of the iterative solver deteriorates. The GCRO-DR iterative solver recycles a subset of harmonic Ritz vectors to initialize the solution subspace for the next linear system in the sequence. The performance of the iterative solver is demonstrated on two exemplars with contact-type nonlinearities and benchmarked against a direct solver with traditional Newton–Raphson iterations.

97 MATHEMATICS AND COMPUTING↗

Enabling elliptically polarized high harmonic generation with short cross polarized laser pulses

Abstract Enabling elliptically polarized high-order harmonics overcomes a historical limitation in the generation of this highly nonlinear process in atomic, molecular and optical physics with applications in other branches. Here, we shed new light on a controversy between experimental observations and theoretical predictions on the possibility to generate harmonics with large ellipticity using two bichromatic laser pulses which are linearly polarized in orthogonal directions. Results of numerical calculations confirm the previous experimental data that in short laser pulses even harmonics with large ellipticity can be obtained for the interaction of such cross-polarized laser pulses with atoms initially in a s - or p -state, while odd harmonics have low ellipticity. The amount of the ellipticity can be controlled via the relative carrier-envelope phase of the pulses, their intensity ratio and the duration of the pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Attosecond synchronization of extreme ultraviolet high harmonics from crystals

The interaction of strong near-infrared (NIR) laser pulses with wide-bandgap dielectrics produces high harmonics in the extreme ultraviolet (XUV) wavelength range. These observations have opened up the possibility of attosecond metrology in solids, which would benefit from a precise measurement of the emission times of individual harmonics with respect to the NIR laser field. In this work, we show that, when high-harmonics are detected from the input surface of a magnesium oxide crystal, a bichromatic probing of the XUV emission shows a clear synchronization largely consistent with a semiclassical model of electron–hole recollisions in bulk solids. On the other hand, the bichromatic spectrogram of harmonics originating from the exit surface of the 200 μm-thick crystal is strongly modified, indicating the influence of laser field distortions during propagation. Our tracking of sub-cycle electron and hole re-collisions at XUV energies is relevant to the development of solid-state sources of attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Enhancing high-order harmonic generation by controlling the diffusion of the electron wave packet

We experimentally study the enhancement of high-order harmonic generation (HHG) driven by synthesized ω <#comment/> − <#comment/> 3 ω <#comment/> laser fields, where we control whether the ionization rate or the electron wave packet’s diffusion is the dominant enhancement mechanism. When minimizing the electron wave packet’s diffusion, the excursion times of the corresponding electron trajectories are reduced by a factor of 2 or more. This result is important for imaging techniques that use the returning electron wave packet to probe the remaining ion. Furthermore, we achieve a 10 × <#comment/> to 3800 × <#comment/> enhancement of the harmonic yield driven by the bichromatic fields relative to that of an optimized single-color field, showing that the bichromatic fields improve HHG’s capability as a light source. We also measure that the two-color field’s harmonics have half the divergence angle compared to their single-color counterpart, suggesting that the “short” electron trajectories play a more prominent role compared to their “long” trajectory counterparts, thus improving the wavefront of the emerging harmonic beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

Equivalence of a harmonic oscillator to a free particle and Eisenhart lift

Highlights: • Equivalence of a harmonic oscillator to a free particle is considered. • The Eisenhart lift is applied to most general harmonic and linear potentials. • In geometric language, equivalence is the result of the conformal flatness of the Eisenhart metric. It is widely known in quantum mechanics that solutions of the Schrödinger equation (SE) for a linear potential are in one-to-one correspondence with the solutions of the free SE. The physical reason for this correspondence is Einstein’s principle of equivalence. What is usually not so widely known is that solutions of the Schrödinger equation with harmonic potential can also be mapped to the solutions of the free Schrödinger equation. The physical understanding of this equivalence is not known as precisely as in the case of the equivalence principle. We present a geometric picture that will link both of the above equivalences with one constraint on the Eisenhart metric.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Harmonic and Subharmonic RF Injection Locking of THz Metasurface Quantum-Cascade VECSEL

Harmonic and subharmonic RF injection locking is demonstrated in a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL). By tuning the RF injection frequency around integer multiples and submultiples of the cavity round-trip frequency, different harmonic and subharmonic orders can be excited in the same device. Modulation-dependent behavior of the device has been studied with recorded lasing spectral broadening and locking bandwidths in each case. In particular, harmonic injection locking results in the observation of harmonic spectra with bandwidths over 200 GHz. A semiclassical Maxwell-density matrix formalism has been applied to interpret QC-VECSEL dynamics, which aligns well with experimental observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Giant electric field-induced second harmonic generation in polar skyrmions

Electric field-induced second harmonic generation allows electrically controlling nonlinear light-matter interactions crucial for emerging integrated photonics applications. Despite its wide presence in materials, the figures-of-merit of electric field-induced second harmonic generation are yet to be elevated to enable novel device functionalities. Here, we show that the polar skyrmions, a topological phase spontaneously formed in PbTiO3/SrTiO3 ferroelectric superlattices, exhibit a high comprehensive electric field-induced second harmonic generation performance. The second-order nonlinear susceptibility and modulation depth, measured under non-resonant 800 nm excitation, reach ~54.2 pm V −1 and ~664% V −1 , respectively, and high response bandwidth (higher than 10 MHz), wide operating temperature range (up to ~400 K) and good fatigue resistance (>10 10 cycles) are also demonstrated. Through combined in-situ experiments and phase-field simulations, we establish the microscopic links between the exotic polarization configuration and field-induced transition paths of the skyrmions and their electric field-induced second harmonic generation response. Our study not only presents a highly competitive thin-film material ready for constructing on-chip devices, but opens up new avenues of utilizing topological polar structures in the fields of photonics and optoelectronics.

Nonlinear optics↗

Extreme ultraviolet time- and angle-resolved photoemission setup with 21.5 meV resolution using high-order harmonic generation from a turn-key Yb:KGW amplifier

Characterizing and controlling electronic properties of quantum materials require direct measurements of nonequilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for time- and angle-resolved photoemission spectroscopy using high-order harmonic probe pulses generated by a robust, moderately high power (20 W) Yb:KGW amplifier with a tunable repetition rate between 50 and 150 kHz. By driving high-order harmonic generation (HHG) with the second harmonic of the fundamental 1025 nm laser pulses, we show that single-harmonic probe pulses at 21.8 eV photon energy can be effectively isolated without the use of a monochromator. The on-target photon flux can reach 5 × 1010 photons/s at 50 kHz, and the time resolution is measured to be 320 fs. The relatively long pulse duration of the Yb-driven HHG source allows us to reach an excellent energy resolution of 21.5 meV, which is achieved by suppressing the space-charge broadening using a low photon flux of 1.5 × 108 photons/s at a higher repetition rate of 150 kHz. The capabilities of the setup are demonstrated through measurements in the topological semimetal ZrSiS and the topological insulator Sb2−xGdxTe3.

Liu, Yangyang↗

Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

A second-harmonic, dispersion interferometer is used to image large-area (≃5 cm 2 ) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample’s dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer’s performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of ΔΦ min ≳ 15 mrad and spatial resolution of Δx res ≃ 100 μm. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N gas ≃ 6 × 10 20 cm –3 and N e ≃ 5 × 10 16 cm –3 ; line-integrated density, ∫N gas dl ~ 2 × 10 19 cm –2 and ∫N e dl ~ 1 × 10 16 cm –2 . The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second harmonic generation for estimating state of charge of lithium-ion batteries

This study applied the nonlinear ultrasonic method, second harmonic generation, to precisely estimate the state of charge (SoC) in lithium-ion batteries. The second harmonic of the longitudinal wave is generated on a pouch cell battery at 5 MHz with a through-transmission setup. The relative nonlinear parameter β' is determined by analyzing the amplitudes at the fundamental and second harmonic frequencies. To enhance the nonlinear parameter's measurement accuracy, multiple excitation amplitudes are employed. Two separate charge/discharge tests (four-cycle and eight-cycle) are conducted on the battery at a rate of C/10. The nonlinear parameter is measured periodically during the charge/discharge process, and temperature compensation is applied to the measurement. The correlation curves between the nonlinear parameter and the actual SoC align well for the four-cycle and eight-cycle tests, and a robust linear relationship is observed for both correlation curves. A linear model and a second-order polynomial model are applied to fit the correlation using all data points from both tests. The two models are employed to validate the SoC prediction on a second battery by using a four-cycle test. Furthermore, the results indicate that both models can predict the SoC with an accuracy of approximately 3%, whereas the polynomial model demonstrates smaller errors in the regions near 0% and 100% SoC. Therefore, the nonlinear parameter β', measured through the second harmonic generation, can effectively predict lithium-ion battery SoC with an accuracy of less than 3%.

25 ENERGY STORAGE↗

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Galaxy clustering in harmonic space from the dark energy survey year 1 data: compatibility with real-space results

ABSTRACT We perform an analysis in harmonic space of the Dark Energy Survey Year 1 Data (DES-Y1) galaxy clustering photometric data using products obtained for the real-space analysis. We test our pipeline with a suite of lognormal simulations, which are used to validate scale cuts in harmonic space as well as to provide a covariance matrix that takes into account the DES-Y1 mask. We then apply this pipeline to DES-Y1 data taking into account survey property maps derived for the real-space analysis. We compare with real-space DES-Y1 results obtained from a similar pipeline. We show that the harmonic space analysis we develop yields results that are compatible with the real-space analysis for the bias parameters. This verification paves the way to performing a harmonic space analysis for the upcoming DES-Y3 data.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic shear in harmonic space from the Dark Energy Survey Year 1 Data: compatibility with configuration space results

ABSTRACT We perform a cosmic shear analysis in harmonic space using the first year of data collected by the Dark Energy Survey (DES-Y1). We measure the cosmic weak lensing shear power spectra using the metacalibration catalogue and perform a likelihood analysis within the framework of CosmoSIS. We set scale cuts based on baryonic effects contamination and model redshift and shear calibration uncertainties as well as intrinsic alignments. We adopt as fiducial covariance matrix an analytical computation accounting for the mask geometry in the Gaussian term, including non-Gaussian contributions. A suite of 1200 lognormal simulations is used to validate the harmonic space pipeline and the covariance matrix. We perform a series of stress tests to gauge the robustness of the harmonic space analysis. Finally, we use the DES-Y1 pipeline in configuration space to perform a similar likelihood analysis and compare both results, demonstrating their compatibility in estimating the cosmological parameters S8, σ8, and Ωm. We use the DES-Y1 metacalibration shape catalogue, with photometric redshifts estimates in the range of 0.2−1.3, divided in four tomographic bins finding σ8(Ωm/0.3)0.5 = 0.766 ± 0.033 at 68 per cent CL. The methods implemented and validated in this paper will allow us to perform a consistent harmonic space analysis in the upcoming DES data.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of symmetric cumulants of hexagonal flow harmonics in Pb-Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

Correlations between event-by-event fluctuations of anisotropic flow harmonics are measured in Pb-Pb collisions at a center-of-mass energy per nucleon pair of 5.02 TeV, as recorded by the ALICE detector at the LHC. This study presents correlations up to the hexagonal flow harmonic 𝑣 6 , which was measured for the first time. The magnitudes of these higher-order correlations are found to vary as a function of collision centrality and harmonic order. These measurements are compared to viscous hydrodynamic model calculations with EKRT initial conditions and to the iEBE-VISHNU model with T R ⁢ENTo initial conditions. The observed discrepancies between the data and the model calculations vary depending on the harmonic combinations. Due to the sensitivity of model parameters estimated with Bayesian analyses to these higher-order observables, the results presented in this work provide new and independent constraints on the initial conditions and transport properties in theoretical models used to describe the system created in heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D small-gain formula allowing strong focusing and harmonic lasing for a ring-based x-ray free electron laser oscillator

We present a detailed derivation of a formula for the small-gain calculation for an x-ray free electron laser oscillator (XFELO) based on a medium-energy (3–4 GeV) storage ring. We found harmonic lasing and strong focusing are essential for this beam energy range. Taking the small-signal low-gain formula developed by Kim and his colleagues, we modified it in such a way that the gain can be calculated without the “no focusing approximation,” and a strong focusing can be applied, as well as harmonic lasing. In this formula, the gain is represented as a product of two factors with one of them depending only on the harmonic number, undulator period, and gap. Using this factor, we show that it is favorable to use harmonic lasing to achieve hard x-ray FEL working in the small-signal low-gain regime with the medium-energy electron beam. Our formula also allows FEL optimization by varying the vertical gradient of the undulator, the vertical dispersion, and the horizontal and vertical focusing, independently. As an example, we applied this formula to study the feasibility of an XFELO option for the National Synchrotron Light Source II (NSLS-II) upgrade. Since a quite high peak current is required for the FEL, collective effects of beam dynamics in medium-energy synchrotrons significantly affect the electron beam parameters. We carried out a multiparameter optimization taking collective effects into account. Note, even though our example is for a ring-based XFELO at 3 to 4 GeV, the formula and, in particular, the approach developed here may be applied to other types of FELs. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Optimal Spatial Separation of High-Order Harmonics from Infrared Driving Lasers with an Annular Beam in the Overdriven Regime

We study high-order harmonic generation (HHG) with an annularly shaped high-power, high-repetition-rate laser. In this work we investigate how the spatial separation (or divergence) of the incident laser and the generated high-order harmonics depends on the gas pressure when the laser intensity is in the overdriven regime. It is shown that, when the cone size of the incident annular beam is relatively large, the resulting harmonics are highly collimated along the propagation axis and are spatially separated from the incident beam. Under the overdriven condition, dynamic phase matching favors HHG emissions from short-trajectory electrons that are efficiently built up in the second half of the gas medium. We verify that using an annular beam is a simple and effective method for separating the intense incident infrared laser from the generated high harmonics. Such high-flux and low-divergence light pulses are expected to be powerful sources in the laboratory for ultrafast probing of electron dynamics.

47 OTHER INSTRUMENTATION↗