Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Experimental demonstration of a 5 kW th granular-flow reactor for solar thermochemical energy storage with aluminum-doped calcium manganite particles

A two-step cycle was discussed for solar thermochemical energy storage based on aluminum-doped calcium manganite reduction/oxidation reactions for direct integration into Air Brayton cycles. The two steps encompassed 1) the storage of concentrated solar direct irradiation via the thermal reduction of aluminum-doped calcium manganite and 2) the delivery of heat to an Air-Brayton cycle via re-oxidation of oxygen-deficient aluminum-doped calcium manganite. The re-oxidized aluminum-doped calcium manganite was fed back to the first step to complete the cycle. A 5 kWth solar thermochemical reactor operating under vacuum was fabricated and tested to examine the first cycle reduction step. Reactor operating conditions and high-flux solar simulator control were tuned for continuous reactor operation with particle temperatures > 1073 K. Continuous operation was achieved using intermittent, dense granular flows. A maximum absorption efficiency of 64.7% was shown, accounting for both sensible and chemical heat storage.

25 ENERGY STORAGE↗

Understanding supercooling mechanism in sodium sulfate decahydrate phase-change material

Salt hydrate-based phase-change materials are considered promising for future heat storage applications in residential heating/cooling systems. Smooth phase transition from the liquid to solid phase and vice versa is essential for effective heat exchanger; however, supercooling in salt hydrates delays the onset of liquid–solid phase transition. We investigate the molecular level mechanism of supercooling in sodium sulfate decahydrate (SSD). SSD is a complex salt hydrate whose properties are governed by electrostatic forces that include pure Coulombic interactions as well as hydrogen bonds. Experimentally, we examine the importance of a nucleator in reducing supercooling temperatures. We investigated the effect of various mass concentrations of a borax nucleator on a decrease of supercooling temperatures. Molecular dynamics simulation techniques are used to obtain a basic understanding of supercooling in SSD. We observe that by introducing borax as a nucleator, there is a decrease in the supercooling temperature before nucleation. Our molecular dynamics simulations show that long-range electrostatics between sodium and sulfate ion pairs and that with polar water molecules is responsible for delayed nucleation in SSD that results in supercooling, and also, dynamics of charged molecules slows down. The lack of crystallization leads to amorphous structures in supercooled SSD.

36 MATERIALS SCIENCE↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

Sensitivity of Arctic Surface Temperature to Including a Comprehensive Ocean Interior Reflectance to the Ocean Surface Albedo Within the Fully Coupled CESM2

Abstract Almost all current climate models simplify the ocean surface albedo (OSA) by assuming the reflected solar energy without the ocean interior contribution. In this study, an improved ocean surface albedo scheme is incorporated into the Community Earth System Model version 2 (CESM2) to assess the sensitivity of Arctic surface temperature to including ocean interior reflectance to the OSA. Fully coupled CESM2 simulations with and without ocean interior reflectance are subsequently performed, we focus on the analysis of Arctic surface temperature responses. Incorporating ocean interior reflectance increases absorbed solar radiation and warms the ocean, enhancing seasonal heat storage and release across the Arctic Ocean, and increasing sea ice reduction and positive climate feedbacks that elevates Arctic surface temperature. Seasonal variations in air‐surface temperature differences induce changes in turbulent heat flux patterns, concurrently modifying dynamic advection and moisture processes that affect boundary layer humidity and low clouds, especially in winter. Based on partitioning physical processes in the thermodynamic energy equation, surface air warming is induced primarily through positive heating anomalies of vertical advection, latent heat release, and longwave radiative forcing. Through an examination of the surface energy budget, skin temperature warming is driven predominantly by increased downward longwave radiation, positive surface albedo feedback in summer, and increased conductive heat transport from the ocean particularly in winter. Significant effects of ocean interior reflectance on the Arctic Ocean, including sea surface warming and sea ice reduction, justify the importance of ocean interior reflectance in climate models for better understanding of ongoing Arctic climate changes.

Meteorology & Atmospheric Sciences↗

Planning for cooler communities: Vacant lots as components of heat resilience in Mesa, Arizona

Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.

community resilience↗

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

14 SOLAR ENERGY↗

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

Gou, Yimeng↗

Evaluating Enhanced Reservoir Evaporation Losses From CMIP6‐Based Future Projections in the Contiguous United States

Abstract Enhanced reservoir evaporation has become an emerging concern regarding water loss, especially when compounded with the ever‐increasing water demand. In this study, we evaluated the evaporation rates and losses for 678 major reservoirs (representing nearly 90% of total storage capacity) in the Contiguous United States over historical baseline (1980–2019), near‐term (2020–2039), and mid‐term (2040–2059) future periods. The evaporation rate was estimated using the Lake Evaporation Model (LEM), an advanced lake evaporation model that addresses both heat storage and fetch effects, driven by multi‐ensemble downscaled Coupled Model Intercomparison Projects 6 (CMIP6) projections under the SSP585 emission scenario. The results project that the evaporation loss may increase by 2.5 × 10 7 m 3 /yr through the research period (1980–2059). Among all regions, the Rio Grande is projected to have the largest increasing rate in the near‐term and mid‐term future, with values of 7.11% of 10.25%, respectively. At the seasonal scale, the most significant increase in the evaporation rate is projected during the fall. The evaporation is projected to increase faster than the streamflow over many of the regions in the southwestern US during the summer/fall, suggesting that the shortage of water will be further exacerbated. The climate models contribute the most to the variance, as compared to the other components related to the projection of evaporation losses (e.g., hydrological model, downscaling method, and historical meteorological data set). These findings demonstrate the need to consider accelerated water loss through open water evaporation in long‐term water resources planning across various spatiotemporal scales.

54 ENVIRONMENTAL SCIENCES↗

Experimental screening of salt hydrates for thermochemical energy storage for building heating application

The selection of a suitable salt hydrate for use in a thermochemical energy storage system is challenging. In this work, the most promising salts to store intermediate heat energy were selected and tested. The criteria set are; volumetric energy density of >500 kWh m-3 with a dehydration temperature of <100 degrees C, material cost of <3.5 USD kg-1 (<15 USD kWh-1), melting does not occur during dehydration and safety. Based on that, the salt hydrates SrCl 2 , MgSO 4 , Na 3 PO 4 , MgCl 2 and SrBr 2 were selected and tested experimentally. A constant temperature and humidity chamber was used to measure moisture sorption of different salts. The hydration is investigated under the conditions of 20 degrees C and 20, 30, 40, 60 and 80% RH, while dehydration is investigated under the conditions of 70, 100 and 140 degrees C using an oven. These dehydration temperatures of <100 degrees C are suitable for solar application whereas the dehydration temperature of 140 degrees C is suitable for waste heat. Furthermore, the salts are cycled over 30 times under the hydration conditions of 20 degrees C, 60% RH with a dehydration temperature of 100 degrees C. From these results, it is concluded that SrCl 2 and SrBr 2 are the most promising salts. This study outlines both the advantages and disadvantages of each salt and states the conditions they are most suitable for.

25 ENERGY STORAGE↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Porous Liquids: Versatile Fusion of Porosity and Fluidity

Porous liquids and fluids with permanent porosity have been explored over the past decade as transformative functional materials for several sustainable chemical processes. This perspective tracks the evolution of porous liquids and summarizes recent advances in the development of porous liquids for several applications, such as sorptive separations, catalysis, etc. Finally, the latter section discusses the prospects of porous liquids in several novel applications (bio applications, gas storage, heat insulation) and machine learning guided pathways for task-specific design and synthesis of porous liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The implications of future climate change on the blue water footprint of hydropower in the contiguous US

As the largest renewable energy source, hydropower is essential to the sustainability of the global energy market. However, a considerable amount of water can be lost in the form of evaporation from the associated multipurpose reservoirs, and hence enlarge the blue water footprint (BWF) of hydropower in a warming climate. To facilitate the sustainable management of both water and energy resources under the impact of climate change in the contiguous United States (CONUS), the BWF values of 143 major multipurpose reservoirs were evaluated during the historical period (1985–2014) and two future periods (2020–2049 and 2070–2099). The historical reservoir evaporation loss was calculated using the Landsat-based reservoir surface area and a new evaporation rate algorithm that considers the heat storage effect. Future projections of runoff availability, hydropower generation, and reservoir evaporation were estimated based on the downscaled climate model ensemble from phase 5 of the Coupled Model Intercomparison Project (CMIP5). It was found that the BWF for the CONUS is highly spatially heterogeneous, with an average value of 26.2 m 3 /MWh in the historical period. In the future, the BWF values are projected to increase under both Representative Concentration Pathway (RCP) 4.5 and 8.5 scenarios. This is especially noticeable under RCP 8.5, which has an average BWF value of 30.2 m 3 /MWh for 2070–2099 (increasing by 15.3% from 26.2 m 3 /MWh). The uncertainty ranges increase even more, from 3.4 m 3 /MWh during 2020–2049 to 5.7 m 3 /MWh during 2070–2099. These findings can benefit water and energy resources management in identifying suitable environmental, economic, operational, and investment strategies for multipurpose reservoirs in a changing environment.

13 HYDRO ENERGY↗

Enhancing the efficiency benefit of thermal barrier coatings for homogeneous charge compression ignition engines through application of a low-k oxide

Prior experiments reported by the authors have proven the hypothesis that achieving a dynamic temperature swing on the combustion chamber surface will lead to improved thermal and combustion efficiencies of the homogeneous charge compression ignition engine. A thin layer of yttria-stabilized zirconia, roughly 150 μm, was plasma sprayed on the piston top. It led to markedly advanced ignition and heat release in the gasoline homogeneous charge compression ignition engine, accompanied with reduced unburnt hydrocarbon and carbon monoxide emissions, improved combustion efficiency, and a higher thermal efficiency. A related computational study highlighted the critical role of coating thermal conductivity in achieving a desired dynamic response; hence, the second phase of experimental investigations focused on introducing structured porosity in the yttria-stabilized zirconia coating, as a means of reducing effective conductivity. Indeed, additional incremental improvements were observed, as well as limitations related to adverse effects of the surface roughness and the fuel interactions with the surface roughness and open pores. Erosion can also be a problem in a direct injection engine. Therefore, the third round of investigations focused on a material with a natively low conductivity (low-k), sprayed on the top of an Al piston in a relatively dense form, and in a way that yields a smooth surface. The objective was to capitalize on the low conductivity, while avoiding the pitfalls accompanying high-porosity formulations. The heat-storage capacity was limited by keeping the thickness relatively low. The results verify the paramount importance of thermal conductivity in the context of high “temperature swing” behavior and indicate a potential to improve the homogeneous charge compression ignition engine’s combustion efficiency roughly 1.5%, with the overall indicated efficiency improvement on the order of 5%, on a relative basis. In addition, the low-k oxide thermal barrier applied to the piston extended significantly the low-load homogeneous charge compression ignition operability limit.

42 ENGINEERING↗

EXPERIMENTAL INVESTIGATION OF IMPACT AND ABRASION EROSIONS AT LOW VELOCITIES AND COMPARISON TO CFD SIMULATIONS

Wear and erosion damage of materials due to interaction of the surface with solid particles is a major issue in various industries. This phenomenon is common in mining, and oil and gas production, causing damages worth millions of dollars annually. Erosion is becoming a critical issue in renewable technologies as well such as concentrated solar thermal power (CSP) systems. In some CSP systems, solid particles can be used to absorb solar energy and enhance the heat storage. However, these particles may cause significant amount of wear to system components while falling down the power tower at high temperatures. This damage can be costly, and therefore, investigating solid particle erosion in CSP systems is of utmost importance. In collaboration with Sandia National Laboratories, the erosion durability of particle-based Generation 3 (GEN3) CSP system are being investigated both experimentally and numerically. In order to develop models to predict the life time of such systems, erosion under low temperature and low particle impact velocity conditions are investigated. Impact erosion and abrasion erosion experiments are conducted for low velocity and low temperature conditions for various candidate particles and containment materials. The impact erosion testing is conducted for three different containment material including Stainless Steel 316, special refractory material, and Inconel 740H with CARBOBEAD HSP 40/70 ceramic particles and UNIWEST 430 silica quartz erodent particles. All this data will enable us to better model the erosion behavior of these materials and provides a data base to investigate erosion at high temperatures experienced in CSP systems. At low temperatures and low velocities the softer refractory material exhibited greater erosion by an order-of-magnitude when compared to the harder Inconel 740H and Stainless Steel 316 materials. The overall erosion ratio for all the candidate materials was of the order of 10 -7 kg/kg. We also investigated wear in containment materials from sliding of particles over the surfaces at very low angles, also referred to as abrasion. For the velocities expected in a typical 1MW CSP plant, visible surface wear was noted, but the overall mass loss per unit surface area was found to be dependent on the hardness of the containment material tested. In this manuscript, we also present Computational Fluid Dynamics (CFD) simulations and erosion prediction of low velocity impact erosion. These results are compared with the experimental data to evaluate the ability of available erosion models for predicting erosion under these conditions.

14 SOLAR ENERGY↗