Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Self-shielding of a plasma-exposed surface during extreme transient heat loads

The power deposition on a tungsten surface exposed to combined pulsed/continuous high power plasma is studied. A study of the correlation between the plasma parameters and the power deposition on the surface demonstrates the effect of particle recycling in the strongly coupled regime. Upon increasing the input power to the plasma source, the energy density to the target first increases then decreases. We suggest that the sudden outgassing of hydrogen particles from the target and their subsequent ionization causes this. This back-flow of neutrals impedes the power transfer to the target, providing a shielding of the metal surface from the intense plasma flux.

36 MATERIALS SCIENCE↗

Recrystallization and modification of the stainless-steel surface relief under photonic heat load in powerful plasma discharges

Targets made of ITER-grade 316L(N)-IG stainless steel and Russian-grade 12Cr18Ni10Ti stainless steel with a close composition were exposed at the QSPA-T plasma gun to plasma photonic radiation pulses simulating conditions of disruption mitigation in ITER. After a large number of pulses, modification of the stainless-steel surface was observed, such as the formation of a wavy structure, irregular roughness, and cracks on the target surface. X-ray and optic microscopic analyses of targets revealed changes in the orientation and dimensions of crystallites (grains) over a depth of up to 20 μm for 316L(N)-IG stainless steel after 200 pulses and up to 40 μm for 12Cr18Ni10Ti stainless steel after 50 pulses, which is significantly larger than the depth of the layer melted in one pulse (∼10 μm). In a series of 200 tests of ITER-grade 316L(N)-IG ITER stainless steel, a linear increase in the height of irregularity (roughness) with increasing number of pulses at a rate of up to ∼1 μm per pulse was observed. No alteration in the chemical composition of the stainless-steel surface in the series of tests was revealed. A model is developed that describes the formation of wavy irregularities on the melted metal surface with allowance for the nonlinear stage of instability of the melted layer with a vapor/plasma flow above it. A decisive factor in this case is the viscous flow of the melted metal from the troughs to tops of the wavy structure. The model predicts saturation of the growth of the wavy structure when its amplitude becomes comparable with its wavelength. Approaches to describing the observed stochastic relief and roughness of the stainless-steel surface formed in the series of tests are considered. The recurrence of the melting-solidification process in which mechanisms of the hill growth compete with the spreading of the material from the hills can result in the formation of a stochastic relief.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing Design Heating Loads in Superinsulated Buildings

The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Analysis of a Pulse Detonation Cross Flow Heat Load Experiment

A comparison between experimentally measured and numerically simulated, time-averaged, point heat transfer rates in a pulse detonation (PDE) engine is presented. The comparison includes measurements and calculations for heat transfer to a cylinder in crossflow and to the tube wall itself using a novel spool design. Measurements are obtained at several locations and under several operating conditions. The measured and computed results are shown to be in substantial agreement, thereby validating the modeling approach. The model, which is based in computational fluid dynamics (CFD) is then used to interpret the results. A preheating of the incoming fuel charge is predicted, which results in increased volumetric flow and subsequent overfilling. The effect is validated with additional measurements.

Paxson, Daniel E.↗

The use of solar simulation systems for producing artificial global radiation for the purpose of determining the heat load of rooms

Certain climatic tests which require solar and sky radiation were carried out in the laboratory by using simulated global radiation. The advantages of such a method of measurement and the possibilities and limitations resulting from the simulation of global radiation are described. Experiments concerning the thermal load in rooms were conducted in order to test the procedure. In particular, the heat gain through a window with sunshade is discussed, a venetian blind between the panes of a double-glazed window being used in most cases.

Kalt, A. C.↗

Comparison of ELM heat loads in snowflake and standard divertors

An analysis is given of the impact of the tokamak divertor magnetic structure on the temporal and spatial divertor heat flux from edge localized modes (ELMs). Two configurations are studied: the standard divertor where the poloidal magnetic field (B{sub p}) varies linearly with distance (r) from the magnetic null and the snowflake where B{sub p} varies quadratrically with r. Both one and two-dimensional models are used to analyze the effect of the longer magnetic field length between the midplane and the divertor plate for the snowflake that causes a temporal dilation of the ELM divertor heat flux. A second effect discussed is the appearance of a broad region near the null point where the poloidal plasma beta can substantially exceed unity, especially for the snowflake configuration during the ELM; such a condition is likely to drive additional radial ELM transport.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Loads Due to Small Penetrations in Multilayer Insulation Blankets

The main penetrations (supports and piping) through multilayer insulation systems for cryogenic tanks have been previously addressed by heat flow measurements. Smaller penetrations due to fasteners and attachments are now experimentally investigated. The use of small pins or plastic garment tag fasteners to each the handling and construction of multilayer insulation (MLI) blankets goes back many years. While it has long been understood that penetrations and other discontinuities degrade the performance of the MLI blanket, quantification of this degradation has generally been lumped into gross performance multipliers (often called degradation factors or scale factors). Small penetrations contribute both solid conduction and radiation heat transfer paths through the blanket. The conduction is down the stem of the structural element itself while the radiation is through the hole formed during installation of the pin or fastener. Analytical models were developed in conjunction with MLI perforation theory and Fouriers Law. Results of the analytical models are compared to experimental testing performed on a 10 layer MLI blanket with approximately 50 small plastic pins penetrating the test specimen. The pins were installed at 76-mm spacing inches in both directions to minimize the compounding of thermal effects due to localized compression or lateral heat transfer. The testing was performed using a liquid nitrogen boil-off calorimeter (Cryostat-100) with the standard boundary temperatures of 293 K and 78 K. Results show that the added radiation through the holes is much more significant than the conduction down the fastener. The results are shown to be in agreement with radiation theory for perforated films.

Structural attachments↗

High speed interference heating loads and pressure distributions resulting from elevon deflections

Effects of elevon-induced three-dimensional shock-wave turbulent boundary-layer interactions on hypersonic aircraft surfaces are analyzed. Detailed surface pressure and heating rate distributions obtained on wing-elevon-fuselage models representative of aft portions of hypersonic aircraft are compared with analytical and experimental results from other sources. Examples are presented that may be used to evaluate the adequacy of current theoretical methods for estimating the effects of three-dimensional shock-wave turbulent boundary-layer interactions on hypersonic aircraft surfaces.

Johnson, C. B.↗

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fundamental studies of heat load and thermal-structure analysis of large space structures

Investigation of the basic requirements for modeling slender member shadowing effects on thermally induced deformation continues. The theoretical formulation is complete and computer programming is underway. The basic requirements for thermal finite elements to model heat transfer in orbiting structures were also studied. The need for planar isothermal elements to model large space structures' antenna meshes was established. Finite Element approaches for modeling space structure cable and membrane components with thermal effects is underway. Three levels of structural modeling and analysis were identified: (1) a linear-elastic small deflection analysis that does not permit cable slackening; (2) a linear-elastic analysis that includes stress stiffening (the ANSYS program), but not large deflections; and (3) full nonlinear large deflection analysis with stress stiffening. Methods of determining cable initial tensions are currently being evaluated.

Thornton, E. A.↗

Response of NSTX Liquid Lithium divertor to High Heat Loads

Samples of the NSTX Liquid Lithium Divertor (LLD) with and without an evaporative Li coating were directly exposed to a neutral beam ex-situ at a power of ~1.5 MW/m2 for 1-3 seconds. Measurements of front face and bulk sample temperature were obtained. Predictions of temperature evolution were derived from a 1D heat flux model. No macroscopic damage occurred when the "bare" sample was exposed to the beam but microscopic changes to the surface were observed. The Li-coated sample developed a lithium hydroxide (LiOH) coating, which did not change even when the front face temperature exceeded the pure Li melting point. These results are consistent with the lack of damage to the LLD surface and imply that heating alone may not expose pure liquid Li if the melting point of surface impurities is not exceeded. This suggests that flow and heat are needed for future PFCs requiring a liquid Li surface. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of aggregate building thermal dynamic model and unmeasured internal heat load from data

This paper is on the problem of simultaneously identifying the parameters of an aggregate thermal dynamic model of a multi-zone building and unknown disturbances from input-output data. An aggregate model is a single-zone equivalent of a multi-zone building, and is useful for many purposes, including model based control of large heating, ventilation and air conditioning (HVAC) equipment that delivers thermal energy to the entire building. A key challenge in identification is the presence of unknown disturbance since it is not measurable but non-negligible.We first present a principled method to aggregate a multizone building model into a single zone model. We then provide a method to identify thermal parameters and the unknown disturbance for this aggregate (single-zone) model. Finally, we test our proposed identification algorithm to data generated from a virtual building. A key insight provided by the aggregation method allows us to recognize under what conditions the estimation of the disturbance signal will be necessarily poor and uncertain.

Guo, Zhong↗

High Temperature Heat Rejection System for Large Heat Loads; Architecture and Trade Study Results

To investigate space nuclear reactor technologies, NASA has awarded several contracts under Project Prometheus, the Nuclear Systems Program. The effort described in this paper was performed under one of those contracts (the Brayton NRA) . Like all power conversion systems, nuclear power conversion systems operate at efficiencies less than 100% resulting in the need to reject waste heat to space. Several different HRSs (Heat Rejection Systems) potential designs have been identified for rejecting NEP (Nuclear Electric Power) waste heat and several of them for a CBC (Closed Brayton Cycle) power conversion system are described herein and the results of their initial analyses presented. The analyses presented were performed as part of an initial trade study to recommend a promising HRS for advancement of its TRL.

Nilitkin, Michael N.↗

Impact of Periodic Unsteadiness on Performance and Heat Load in Axial Flow Turbomachines

Results of an analytical and experimental investigation, directed at the understanding of the impact of periodic unsteadiness on the time-averaged flows in axial flow turbomachines, are presented. Analysis of available experimental data, from a large-scale rotating rig (LSRR) (low speed rig), shows that in the time-averaged axisymmetric equations the magnitude of the terms representing the effect of periodic unsteadiness (deterministic stresses) are as large or larger than those due to random unsteadiness (turbulence). Numerical experiments, conducted to highlight physical mechanisms associated with the migration of combustor generated hot-streaks in turbine rotors, indicated that the effect can be simulated by accounting for deterministic stress like terms in the time-averaged mass and energy conservation equations. The experimental portion of this program shows that the aerodynamic loss for the second stator in a 1-1/2 stage turbine are influenced by the axial spacing between the second stator leading edge and the rotor trailing edge. However, the axial spacing has little impact on the heat transfer coefficient. These performance changes are believed to be associated with the change in deterministic stress at the inlet to the second stator. Data were also acquired to quantify the impact of indexing the first stator relative to the second stator. For the range of parameters examined, this effect was found to be of the same order as the effect of axial spacing.

Sharma, Om P.↗