Search NASA⌕ Search

SEARCH · Search NASA

Results for “High contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging perturbed shock propagation in powders

A novel experimental methodology is presented to study the deviatoric response of powders in shock regimes. The powders are confined to a cylindrical wedge volume, and a projectile-driven shock wave with a sinusoidally varying front propagates through the powder. The perturbed shock wave exhibits a damping behavior due to irreversible processes of viscosity and strength (deviatoric) of the powder with propagation through increasing powder thicknesses. The inclined surface of the wedge is polished and coated to establish a diffuse surface suitable for reflecting incident laser light into a high-speed camera imaging at 5 MHz. Images of the contrast loss upon shock wave arrival at the observation surface are post-processed for qualitative and quantitative information. New data of shock damping behavior with parameters of perturbation wavelength and initial shock strength are presented for powders of copper, tantalum, and tungsten carbide as well as their mixtures. We present the first full-field images showing additional spatial disturbances on the perturbed shock front that appear dependent on particle material and morphology.

47 OTHER INSTRUMENTATION↗

Direct observations of shock-induced melting in a porous solid using time-resolved x-ray diffraction

Here in this work we provide direct evidence of shock-induced melting and associated kinetics in a porous solid (aluminum powder) using time-resolved x-ray diffraction. Unambiguous evidence of melting in 50% porous aluminum (Al) powder samples, shocked to peak pressures between ~13 - 19 GPa, was provided by the broadening of the Debye-Scherrer ring corresponding to the (111) peak. Shocked Al powder did not melt completely in any of our experiments within the durations of measurement. Incomplete (partial) melting of the powder, even after several hundreds of nanoseconds of shock loading, provides insights into thermal transport with Al powder particles under high-pressure dynamic loading. Such insights are quite valuable for developing well-constrained melting models and thermodynamic equations of state for porous Al and other porous solids relevant to planetary and materials science.

36 MATERIALS SCIENCE↗

Quantitative phase microscopy monitors subcellular dynamics in single cells exposed to nanosecond pulsed electric fields

A substantial body of literature exists to study the dynamics of single cells exposed to short duration (<1 μs), high peak power (~1 MV/m) transient electric fields. Much of this research is limited to traditional fluorescence-based microscopy techniques, which introduce exogenous agents to the culture and are only sensitive to a single molecular target. Quantitative phase imaging (QPI) is a coherent imaging modality which uses optical path length as a label-free contrast mechanism, and has proven highly effective for the study of single-cell dynamics. In this work, we introduce QPI as a useful imaging tool for the study of cells undergoing cytoskeletal remodeling after nanosecond pulsed electric field (nsPEF) exposure. In particular, we use cell swelling, dry mass and disorder strength measurements derived from QPI phase images to monitor the cellular response to nsPEFs. We hope this demonstration of QPI's utility will lead to a further adoption of the technique for the study

59 BASIC BIOLOGICAL SCIENCES↗

Multi-microscopy characterization of threading dislocations in CVD-grown diamond films

We present site-coincident imaging of a high dislocation density boron-doped chemical vapor deposition-grown homoepitaxial (001) diamond film using electron channeling contrast imaging (ECCI), cathodoluminescence, transmission electron microscopy (TEM), and scanning secondary ion mass spectroscopy (SIMS). With growing interest in large area heteroepitaxial substrates, we show that ECCI is a promising technique to accurately evaluate dislocations in diamond films. We find the electron backscatter yield is sufficient to distinguish individual threading dislocations in ECCI despite the low atomic number of carbon, and we have generally good agreement between dislocations observed in ECCI and TEM of the same region. Importantly, relying on luminescence in the 430 nm dislocation-related A-band alone results in an underestimation of the defect density as we find only 20%–40% of the threading dislocations luminesce. Here, we further show that dislocations do not perturb the spatial uniformity of boron doping measured by SIMS, even when the dislocations are clustered with high density, and we can tentatively rule out strong segregation effects at the dislocations. Our results establish the complementary use of microscopy and microanalysis methods to rapidly characterize and understand the impact of dislocations in diamond thin films.

36 MATERIALS SCIENCE↗

Time resolved in-situ multi-contrast X-ray imaging of melting in metals

In this work, the application of a time resolved multi-contrast beam tracking technique to the investigation of the melting and solidification process in metals is presented. The use of such a technique allows retrieval of three contrast channels, transmission, refraction and dark-field, with millisecond time resolution. We investigated different melting conditions to characterize, at a proof-of-concept level, the features visible in each of the contrast channels. We found that the phase contrast channel provides a superior visibility of the density variations, allowing the liquid metal pool to be clearly distinguished. Refraction and dark-field were found to highlight surface roughness formed during solidification. This work demonstrates that the availability of the additional contrast channels provided by multi-contrast X-ray imaging delivers additional information, also when imaging high atomic number specimens with a significant absorption.

36 MATERIALS SCIENCE↗

Design of Neutron Microscopes Equipped with Wolter Mirror Condenser and Objective Optics for High-Fidelity Imaging and Beam Transport

We present and compare the designs of three types of neutron microscopes for high-resolution neutron imaging. Like optical microscopes, and unlike standard neutron imaging instruments, these microscopes have both condenser and image-forming objective optics. The optics are glancing-incidence axisymmetric mirrors and therefore suitable for polychromatic neutron beams. The mirrors are designed to provide a magnification of 10 to achieve a spatial resolution of better than 10 μm. The resolution of the microscopes is determined by the mirrors rather than by the L/Dratio as in conventional pinhole imaging, leading to possible dramatic improvements in the signal rate. We predict the increase in the signal rate by at least two orders of magnitude for very high-resolution imaging, which is always flux limited. Furthermore, in contrast to pinhole imaging, in the microscope, the samples are placed far from the detector to allow for a bulky sample environment without sacrificing spatial resolution.

47 OTHER INSTRUMENTATION↗

High Contrast Pattern Projection To Enable Background Oriented Schlieren Based Air Leak Detection Through Any Interior Or Exterior Building Surface

Air leakage in buildings wastes an estimated 4 quads of energy per year in the United States. Finding and sealing leakage sites is critical in existing buildings. Previous work has shown that background oriented Schlieren (BOS) imaging can be used to visualize air leakage but requires the leak to exit through a high contrast surface like a brick wall. To remedy this, different techniques of projecting various high contrast patterns on low contrast building surfaces like interior gypsum walls or vinyl siding were investigated. For each technique, the background quality was measured and compared to an ideal printed random dot background. The background quality metrics were correlated with the measured visualization metrics to understand which metrics are most important for maximizing air leak visualization performance. In this work, leakage visualization performance is presented for these various projected backgrounds with an aim to expand the building surfaces suitable for the BOS leak detector.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

Scattering-type scanning near-field optical microscopy with Akiyama piezo-probes

Recent developments of the scattering-type scanning near-field optical microscope at cryogenic temperatures (cryogenic s-SNOM or cryo-SNOM) have led to many breakthroughs in the studies of low energy excitations in quantum materials. However, the simultaneous demands on vibration isolation, low base temperature, precise nano-positioning, and optical access make the construction of a cryo-SNOM a daunting task. Adding to the overhead space required for a cryo-SNOM is the atomic force microscopy control, which predominantly utilizes a laser-based detection scheme for determining the cantilever tapping motion. In this work, we provide an alternative and straightforward route to performing s-SNOM using metal-coated Akiyama probes, where the cantilever tapping motion is detected through a piezoelectric signal. We show that the Akiyama-based cryo-SNOM attains high spatial resolution, good near-field contrast, and is able to perform imaging with a significantly more compact system compared to other cryo-SNOM implementations. Our results firmly establish the potential of s-SNOM based on self-sensing piezo-probes, which can easily accommodate far-infrared wavelengths and high magnetic fields in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strain-driven oxygen vacancy ordering in LaNiO 3 thin films revealed by integrated differential phase contrast imaging in scanning transmission electron microscopy

Rare-earth nickelates, such as LaNiO 3 (LNO), exhibit complex electronic properties, with ordered oxygen vacancies (OOV) influencing conductivity and magnetic behavior. We investigate the structural stability of strain-induced OOV phases in LNO thin films grown on SrTiO 3 substrates and the impact of Ruddlesden–Popper (RP) faults. Using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and integrated differential phase contrast (iDPC) STEM imaging, we conducted atomic-scale structural and compositional analyses of OOV. Geometric phase analysis (GPA) was employed to measure the strain in fault-free and RP fault regions, while density functional theory (DFT) calculations explored different OOV arrangements in the LNO phase. Simulated iDPC-STEM imaging of energy-stabilized structures was performed to correlate with experimental results. Here, our findings reveal superstructure modulation in the chemical composition and atomic-scale lattice structure in LNO, primarily due to the formation of the OOV in Ni–O layers of the LaNiO 2.5 phase. The out-of-plane compressive strain of about 2% stabilizes this phase, reducing the strain, diminishing OOV, and transforming them into LNO.

36 MATERIALS SCIENCE↗

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Debris Disk Results from the Gemini Planet Imager Exoplanet Survey's Polarimetric Imaging Campaign

We report the results of a ∼4 yr direct imaging survey of 104 stars to resolve and characterize circumstellar debris disks in scattered light as part of the Gemini Planet Imager (GPI) Exoplanet Survey. We targeted nearby (≲150 pc), young (≲500 Myr) stars with high infrared (IR) excesses (L {sub IR}/L {sub ⋆} > 10{sup −5}), including 38 with previously resolved disks. Observations were made using the GPI high-contrast integral field spectrograph in H-band (1.6 μm) coronagraphic polarimetry mode to measure both polarized and total intensities. We resolved 26 debris disks and 3 protoplanetary/transitional disks. Seven debris disks were resolved in scattered light for the first time, including newly presented HD 117214 and HD 156623, and we quantified basic morphologies of five of them using radiative transfer models. All of our detected debris disks except HD 156623 have dust-poor inner holes, and their scattered-light radii are generally larger than corresponding radii measured from resolved thermal emission and those inferred from spectral energy distributions. To assess sensitivity, we report contrasts and consider causes of nondetections. Detections were strongly correlated with high IR excess and high inclination, although polarimetry outperformed total intensity angular differential imaging for detecting low-inclination disks (≲70°). Based on postsurvey statistics, we improved upon our presurvey target prioritization metric predicting polarimetric disk detectability. We also examined scattered-light disks in the contexts of gas, far-IR, and millimeter detections. Comparing H-band and ALMA fluxes for two disks revealed tentative evidence for differing grain properties. Finally, we found no preference for debris disks to be detected in scattered light if wide-separation substellar companions were present.

79 ASTRONOMY AND ASTROPHYSICS↗

Perivascular network segmentations derived from high-field MRI and their implications for perivascular and parenchymal mass transport in the rat brain

A custom segmentation workflow was applied to ex vivo high-field MR images of rat brains acquired following in vivo intraventricular contrast agent infusion to generate maps of the perivascular spaces (PVS). The resulting perivascular network segmentations enabled analysis of perivascular connections to the ventricles, parenchymal solute clearance, and dispersive solute transport within PVS. Numerous perivascular connections between the brain surface and the ventricles suggest the ventricles integrate into a PVS-mediated clearance system and raise the possibility of cerebrospinal fluid (CSF) return from the subarachnoid space to the ventricles via PVS. Assuming rapid solute exchange between the PVS and CSF spaces primarily by advection, the extensive perivascular network decreased the mean clearance distance from parenchyma to the nearest CSF compartment resulting in an over 21-fold reduction in the estimated diffusive clearance time scale, irrespective of solute diffusivity. This corresponds to an estimated diffusive clearance time scale under 10 min for amyloid-beta which suggests that the widespread distribution of PVS may render diffusion an effective parenchymal clearance mechanism. Additional analysis of oscillatory solute dispersion within PVS indicates that advection rather than dispersion is likely the primary transport mechanism for dissolved compounds greater than 66 kDa in the long (> 2 mm) perivascular segments identified here, although dispersion may be significant for smaller compounds in shorter perivascular segments.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of sucrose crystallization kinetics using confocal microscopy: Determining differences in sucrose crystallization kinetics between single and polycrystal studies

Sucrose solution crystal growth kinetics are dependent on temperature, concentration, and impurities. A double polarized confocal microscopy system was used to obtain photographs with high contrast between growing crystals and the background for color background removal image processing. Seeded solutions of 72 wt% sucrose at 27, 35, 45, and 55°C were compared for single and polycrystals. Polycrystal analysis was determined to offer more rapid image processing and to be more applicable to systems in real operating conditions, while single-crystal analysis was determined to give more comprehensive descriptions of individual crystal behavior at the cost of slower processing.

36 MATERIALS SCIENCE↗