Search NASA⌕ Search

SEARCH · Search NASA

Results for “High energy density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A generalized approach to x-ray data modeling for high-energy-density plasma experiments

Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, in this study, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.

Nagayama, Taisuke↗

Charged-particle transport in high energy density plasmas

This Special Topic Collection grew out of two gatherings of researchers active in the high energy density (HED) physics community: a mini-conference on charged-particle transport in HED plasma held during the 64th annual meeting of the American Physical Society's Division of Plasma Physics (Spokane, WA, November 2022) and a dedicated charged-particle transport coefficient code comparison workshop (Livermore, CA, July 2023). These gatherings provided opportunities for theoretical, computational, and experimental researchers to discuss the state of the field, including current capabilities and methods, needs of hydrodynamic simulations, and frontiers for future research. Finally, this special issue collects a total of 13 research and review articles on charged-particle transport in HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

K-shell radiation and bright spot characteristics of high-energy-density Fe-Cr-Ni plasmas influenced by X-pinch load geometry

K-shell radiation is diagnostically advantageous for the study of high-energy-density plasmas. Here, the current work investigates the influence of load geometry on K-shell x-rays in Z-pinch plasmas produced on the 1-MA Zebra generator. Stainless steel (Fe: 69%, Cr: 20%, Ni: 9%) X-pinch wire loads are fielded with an interwire angle of 31° (small-angle) or 62.5° (large-angle), respectively and studied using various x-ray diode, imaging, and spectroscopic diagnostics. The large-angle geometry produced large, individual x-ray-emitting bright spots (> 3 keV) at the wire cross-point averaging areas ≥ 1 mm 2 , with noteworthy soft x-ray (> 0.75 keV) bursts and radiation yields ≤ 14.6 kJ. The small-angle geometry produced multiple x-ray-emitting bright spots extending the pinch axis with smaller average sizes (≤ 0.5 mm 2 ), consistent with stronger current, increased radiation yield (≥ 15.5 kJ), and notable hard x-ray (> 9 keV) bursts, which peak with largest cumulative bright spot size. Spectroscopic analysis is performed with non-LTE collisional-radiative modeling, indicating a cold, nonthermal plasma region radiating from neutral to Ne-like ions, a hot, thermal region radiating from Fe and Cr He- and Li-like ions, and an intermediate region radiating Kα satellites from Li-like to O-like ions. Modeling of the nonthermal and satellite features imply a fractional hot electron abundance ~0.1% and ~0.5% for large- and small-angle geometries, respectively. Relative intensity analysis is performed on Heα and Kα lines, revealing intensity ratios that deviate from the original wire composition. Optical depth estimates allude to optically thick, thermal K-shell plasmas with densities consistent with non-LTE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting Discharge Mechanism of CF x as a High Energy Density Cathode Material for Lithium Primary Battery

Lithium/fluorinated graphite (Li/CFx) primary batteries show great promise for applications in a wide range of energy storage systems due to their high energy density (>2100 Wh kg –1 ) and low self-discharge rate (<0.5% per year at 25 °C). While the electrochemical performance of the CF x cathode is indeed promising, the discharge reaction mechanism is not thoroughly understood to date. In this article, a multiscale investigation of the CF x discharge mechanism is performed using a novel cathode structure to minimize the carbon and fluorine additives for precise cathode characterizations. Titration gas chromatography, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, cross-sectional focused ion beam, high-resolution transmission electron microscopy, and scanning transmission electron microscopy with electron energy loss spectroscopy are utilized to investigate this system. Results show no metallic lithium deposition or intercalation during the discharge reaction. Crystalline lithium fluoride particles uniformly distributed with <10 nm sizes into the CF x layers, and carbon with lower sp2 content similar to the hard-carbon structure are the products during discharge. This article deepens the understanding of CF x as a high energy density cathode material and highlights the need for future investigations on primary battery materials to advance performance.

25 ENERGY STORAGE↗

Modeling Hydrodynamic Instabilities, Shocks, and Radiation Waves in High Energy Density Experiments [Dissertation]

This thesis presents the computational design, modeling, and analysis of three experiments in high-energy density physics (HEDP), all of them concerning fundamental radiation flows. The first experiment is a laboratory astrophysics experiment to investigate the role of the Kelvin-Helmholtz instability (KHI) in the process of galactic filaments supplying gas to galactic halos. The achieved goal was to provide a first study in which the role of the instability is maximal and predict behavior in future iterations of an experiment accessing a more radiative regime where the role of the instability is stifled. This experiment would help answer how certain galaxies are able to grow so rapidly and produce many stars as the KHI limits this process. The second experiment, COAX, is a radiation flow experiment with a novel spectroscopy diagnostic configuration, designed to spatially measure the temperature of a radiation wave as it travels down a doped foam. A key result of this work was the development of a synthetic spectroscopy application and application of modern spectroscopy comparison techniques to provide our first temperature reconstructions from the experimental data. This experimental platform serves as the launching ground for a number of new experiments that vary the basic premise and thus is foundational to our ongoing research. The final experiment is a full integration of modeling, design, and theoretical development for the Radishock experiment. This experimental platform studies the head-on collision of a radiation wave with a counter-propagating shock, and like COAX, uses spectroscopy to diagnose and detect the interaction. My research analyzes the successful shots, indicating aspects of successful detections and suggests improvements to future iterations of the design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Seismic Signature of a High-Energy Density Physics Laboratory and Its Potential for Measuring Time-Dependent Velocity Structure

The Z Machine at Sandia National Laboratories is a pulsed power facility for high-energy density physics experiments that can shock materials to extreme temperatures and pressures through a focused energy release of up to ~ 25 MJ in < 100 nanoseconds. It has been in operation for more than two decades and conducts up to ~ 100 experiments, or “shots,” per year. Based on a set of 74 known shot times from 2018, we determined that Z Machine shots produce detectable ~ 3–17 Hz ground motion 12 km away at the Albuquerque Seismological Laboratory, New Mexico (ANMO), borehole seismograph, with peak signal at ~ 7 Hz. The known shot waveforms were used to create a three-component template, leading to the detection of 2339 Z Machine shots since 1998 through single-station cross-correlation. Local seismic magnitude estimates range from local magnitude (M L ) —2 to —1.3 and indicate that only a small fraction of the shot energy is transmitted by seismic phases observable at 12 km distance. The most recent major facility renovation, which was intended to decrease mechanical dissipation, is associated with an abrupt decrease in observed seismic amplitudes at ANMO despite stable maximum shot energy. The highly repetitive impulsive sources are well suited to coda-wave interferometry to investigate time-dependent velocity structures. Relative velocity variations (dv/v) show an annual cycle with amplitude of ~ 0.2%. Local minima are observed in the late spring, and dv/v increases through the summer monsoon rainfall, possibly reflecting patchy saturation as rainfall infiltrates near the eastern edge of the Albuquerque basin. Importantly, the cumulative results demonstrate that forensic seismology can provide insight into long-term operation of facilities such as pulsed-power laboratories, and that their recurring signals may be valuable for studies of time-dependent structure

54 ENVIRONMENTAL SCIENCES↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the importance of three-dimensional modeling for high-energy-density physics experiments

Laser-driven cylindrical implosion experiments enable direct measurements of hydrodynamic instability growth in convergent geometries, providing a wealth of validation data in the high-energy-density regime. These experiments are designed to be nearly axially invariant, allowing for modeling with complementary two-dimensional slices of the cylinder. Two distinct hydrodynamics codes are employed to model a subset of these experiments, and the results are shown to be in very good agreement with each other and the available experimental data. While this 2D modeling approach adequately captures most of the physics of the implosion and ensuing instability growth, there are crucial aspects from the three-dimensional nature of the experiments that are missed in 2D. The first fully 3D simulations of these experiments are presented, and small but significant differences are found to arise from both the axial and azimuthal non-uniformity in the laser drive. Recent experimental results confirming the drive asymmetry are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametrized ion-distribution model for extended x-ray absorption fine-structure analysis at high-energy-density conditions

Experiments today can compress solids near isentropically to pressures approaching 100 × 106 atmospheres; however, determining the temperature of such matter remains a major challenge. Extended x-ray absorption fine-structure (EXAFS) spectroscopy is one of the few techniques sensitive to the bulk temperature of highly compressed solid matter, and the validity of this temperature measurement relies on constraining the local ion structure from the EXAFS spectrum. At high-energy-density (HED) conditions, the local ion structure often becomes distorted, which must be accounted for during the EXAFS analysis. Described here is a technique, using a parametrized ion-distribution model to directly analyze EXAFS spectra that provides a better constraint on the local structure than traditional second- or third-order cumulant expansion techniques at HED conditions. The parametrized ion-distribution model is benchmarked by analyzing EXAFS spectra from nickel molecular-dynamics simulations at ∼100 GPa and shown to provide a 10%–20% improvement in constraining the cumulants of the true ion distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser cutting apparatus for high energy density and diamond anvil cell science

In this paper, we present a low-cost, high-resolution laser cutting system designed for use in the fabrication of samples for high energy density physics. Such samples are necessarily small but require precision and repeatability, particularly with the recently available high repetition rates possible at modern facilities. The system allows simultaneous laser cutting, using nanosecond near-infrared laser pulses, and optical microscopy so that the cut can be monitored in real time. The capabilities of the system are demonstrated on a range of materials for both laser-matter interaction targets and components for high pressure diamond anvil cell experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy-density cylindrical capacitors

Manufacturing technique produces high quality metalized-film cylindrical capacitors of energy density greater than 0.1 J/g uncased, using either 24-gage polyvinylidene flouride or 14-gage polycarbonate film. Components are wound wrinkle-free on hollow PTFE cores, using winding machine that applies constant dynamically controlled tension to film during winding operation.

Parker, R. D.↗

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗

New Engineering Concepts to High Energy Density Li-S Batteries

Li-S batteries (LSBs) with energy densities > 500 Wh/kg @ C/5 and >1000 cycles, cycle life operating over wide temperatures has been identified to be critical for meeting the global energy demands. Progress is however, very much limited due to several major hurdles related to the following: (a) poor Li' reaction kinetics (conductivity/diffusivity) enabling full reversible S conversion to Li2S, (b) inferior electron (e) conductivity, specific capacity and cycle life due to electrolyte soluble species of polysulfides (PSs) formed with the reaction of Li ions with sulfur migrating to anode, (c) unstable solid electrolyte interphase (SEI) formation and finally, (d) dendrites that are formed on the Li metal anode severely limiting the cycle life due to polarization at the solid/liquid interfaces causing safety, inferior capacity, energy density, rate, and cycle life issues. Creation of a fully functional economical ≤$80/kWh, high energy density LSBs is vital for enabling its widespread commercial deployment and use in current and next generation electric vehicles.

25 ENERGY STORAGE↗

A redox-active organic cation for safer high energy density Li-ion batteries

Ni-rich layered cathode materials are at the forefront to be deployed in high energy density Li-ion batteries for the automotive market. However, the intrinsic poor structural and interfacial stability during overcharging could trigger violent thermal failure, which severely limits their wide application. To protect the Ni-rich cathode from overcharging, we firstly report a redox-active cation, thioether-substituted diaminocyclopropenium, as an electrolyte additive to limit the cell voltage within the safe value during overcharging. The organic cation demonstrates a record-breaking electrochemical reversibility at ~4.55 V versus Li + /Li and solubility (0.5 M) in carbonate-based electrolyte. The protection capability of the additive was explored in two cell chemistries: a LiNi 0.8 Co 0.15 Al 0.05 O 2 /graphite cell and a LiNi 0.8 Co 0.15 Al 0.05 O 2 /silicon–graphene cell with areal capacities of ~2.2 mA h cm -2 and ~3 mA h cm -2 , respectively. With 0.2 M addition, the LiNi 0.8 Co 0.15 Al 0.05 O 2 /graphite cell survived 54 cycles at 0.2C with 100% overcharge. Moreover, the cell can carry an utmost 4.4 mA cm -2 (2C) with 100% overcharge and a maximum capacity of 7540% SOC at 0.2C.

25 ENERGY STORAGE↗

Electrochemically Stable High Energy Density Lithium-Sulfur Batteries

Lithium-Sulfur batteries (LSB) have emerged as one of the strong contenders for high energy density rechargeable batteries in the Li-ion battery domain. The LSB system is considered as the most promising to achieve the next milestone in energy density of 500 Wh/kg. However, the LSB system is plagued with problems of polysulfide formation which are soluble in the organic electrolyte leading to loss in capacity and eventual cell failure. The problem is further compounded by dendrite formation on the Li anode during electrochemical cycling leading to puncturing of the separator causing eventual short-circuiting of the cell and consequent heat generation resulting in major safety hazards of flammability of the organic liquid electrolyte and impending explosion. This chapter describes various approaches developed to combat both cathode and anode issues. These involve synthesis and characterization of complex framework materials (CFMs) for confining the polysulfides and sulfur in the LSB cathodes. The CFMs include a CFM host and a coating applied to the CFM host, which includes one or more form of an electronic conductor, a lithium-ion conductor and a functional electrocatalyst for electrocatalytically converting the soluble polysulfides to Li 2 S. Further, sulfur is infiltrated into the CFM host creating a sulfur-carbon linkage serving as effective anchors for trapping the ensuing polysulfides. The systems have been tested in coin cells and pouch cells with metallic Li anodes under lean electrolyte conditions of 3-4 μl/mg of electrolyte (E) to sulfur (S) ratios showing promise and feasibility. New emergent dendrite-free alloys have also been identified to test against pure Li and CFM cathodes in coin cell and pouch cell configurations under lean electrolyte conditions. Results of these studies are described and discussed with thoughts on future directions.

25 ENERGY STORAGE↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗