Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC national accelerator laboratory. Here we have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1–10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (> 30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (< 10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30–160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure ≥ 1.5Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2Torr, simulation results and experimental data show that the beam transfers about 60% of its energy to the wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light and Electron Emission as Breakdown Probes: Synergistic DC and RF Study

The project was motivated by a particular and critical need in accelerator R&D to understand vacuum breakdown and arc as it would allow for developing high gradient machines. Accelerator systems operated at high gradients are less costly and more compact. This, in turn, would enable advanced and cost-effective accelerators for future colliders. Universities and medical centers would be able to build compact accelerator machines for basic X-ray and microscopy sciences, therapy, isotope production, sterilization etc.

43 PARTICLE ACCELERATORS↗

New accelerator capabilities with the high-gradient C-band [Slides]

LANSCE accelerator upgrades: Applications such as pRad desire higher proton beam energy. Material science at LANL will benefit from powerful directional high repetition rate X-ray sources. As it considers itself to be the NNSA accelerator laboratory, LANL should play role in developing compact accelerators for various national security missions.

43 PARTICLE ACCELERATORS↗

The science case for an intermediate energy advanced and novel accelerator linear collider facility

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1–100 GV/m, leading to compact acceleration facilities. However, intermediate energy facilities (IEF) are required to test the critical technology elements on the way towards multi-TeV-class colliders. Here a science case for a 20–100 GeV center-of-mass energy ANA-based lepton collider that can be a candidate for an intermediate energy facility is presented. The IEF can provide numerous opportunities for high energy physics studies including precision Quantum Chromodynamics and Beyond the Standard Model physics measurements, investigation of charged particle interactions with extreme electromagnetic fields, and exploring muon and proton beam acceleration. Possible applications of this collider include the studies of γγ and electron beam-fixed target/beamdump collider designs. Thus, the goal of the proposed IEF is to both carry out particle physics measurements in the 20-100 GeV ranges as well as to serve as an ANA demonstrator facility.

43 PARTICLE ACCELERATORS↗

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration of Cascaded Modulator-Chicane Microbunching of a Relativistic Electron Beam

Here, we present results of an experiment showing the first successful demonstration of a cascaded microbunching scheme. Two modulator-chicane prebunchers arranged in series and a high power mid-IR laser seed are used to modulate a 52 MeV electron beam into a train of sharp microbunches phase locked to the external drive laser. This configuration is shown to greatly improve matching of the beam into the small longitudinal phase space acceptance of short-wavelength accelerators. We demonstrate trapping of nearly all (96%) of the electrons in a strongly tapered inverse free-electron laser accelerator, with an order-of-magnitude reduction in injection losses compared to the classical single-buncher scheme. These results represent a critical advance in laser-based longitudinal phase space manipulations and find application in high gradient advanced acceleration as well as in high peak and average power coherent radiation sources.

43 PARTICLE ACCELERATORS↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

High gradient RF test results of S-band and C-band cavities for medical linear accelerators

TERA Foundation has proposed and designed hadrontherapy facilities based on novel linacs, i.e. high gradient linacs which accelerate either protons or light ions. The overall length of the linac, and therefore its cost, is almost inversely proportional to the average accelerating gradient. With the scope of studying the limiting factors for high gradient operation and to optimize the linac design, TERA, in collaboration with the CLIC Structure Development Group, has conducted a series of high gradient experiments. The main goals were to study the high gradient behavior and to evaluate the maximum gradient reached in 3 and 5.7 GHz structures to direct the design of medical accelerators based on high gradient linacs. Lastly, this paper summarizes the results of the high power tests of 3.0 and 5.7 GHz single-cell cavities.

43 PARTICLE ACCELERATORS↗

Experimental high gradient testing of a 17.1 GHz photonic band-gap accelerator structure

We report the design, fabrication and high gradient testing of a 17.1 GHz Photonic Band Gap accelerator structure. Photonic band-gap (PBG) structures are promising candidates for electron accelerators capable of high-gradient operation because they have the inherent damping of high order modes required to avoid beam breakup instabilities. The 17.1 GHz PBG structure tested was a single cell structure composed of a triangular array of round copper rods of radius 1.45 mm spaced by 8.05 mm. The test assembly consisted of the test PBG cell located between conventional (pillbox) input and output cells, with input power of up to 4 MW from a klystron supplied via a TM01 mode launcher. Breakdown at high gradient was observed by diagnostics including reflected power, downstream and upstream current monitors and visible light emission. The testing procedure was first benchmarked with a conventional disc-loaded waveguide structure, which reached a gradient of 87 MV/m at a breakdown probability of 1.19 × 10^-1 per pulse per meter. The PBG structure was tested with 100 ns pulses at power levels of less than 90 MV/m in order to limit the surface temperature rise to 120 K. The PBG structure reached up to 89 MV/m at a breakdown probability of 1.09×10^-1 per pulse per meter. These test results show that a PBG structure can simultaneously operate at high gradients and low breakdown probability, while also providing wakefield damping.

43 PARTICLE ACCELERATORS↗

Nanosecond rf-Power Switch for Gyrotron-Driven Millimeter-Wave Accelerators

The development of alternative mm-wave high-gradient, >200 MV/m, accelerating structures offers a promising path to reduce the cost and footprint of future TeV-scale linear colliders, as well as linacs for industrial, medical, and security applications. The major factor limiting accelerating gradient is vacuum rf breakdown. The probability of such breakdowns increases with pulse length. For reliable operation, millimeter-wave structures require nanoseconds-long pulses at the megawatt level. This power is available from gyrotrons, which have a minimum pulse length on the order of microseconds. To create shorter pulses and to reliably detect rf breakdowns, we developed the following devices: a laser-based rf switch capable of selecting 10 ns long pulses out of the microseconds long gyrotron pulses, thus enabling the use of the gyrotrons as power sources for mm-wave high-gradient linacs, and a shot-to-shot sub-THz spectrometer with high-frequency resolution, capable of detecting pulse shortening due to rf breakdowns. We will describe the principle of operation of these devices and their achieved parameters. Here, we also report on the experimental demonstration of these devices with the high-power gyrotron at the Massachusetts Institute of Technology. In the experiments, we demonstrate nanosecond rf power modulation, shot-to-shot measurements of the pulse spectra, and detection of rf breakdowns.

43 PARTICLE ACCELERATORS↗

High Efficiency Uniform Wakefield Acceleration of a Positron Beam Using Stable Asymmetric Mode in a Hollow Channel Plasma

Plasma wakefield acceleration in the blowout regime is particularly promising for high-energy acceleration of electron beams because of its potential to simultaneously provide large acceleration gradients and high energy transfer efficiency while maintaining excellent beam quality. However, no equivalent regime for positron acceleration in plasma wakes has been discovered to date. We show that after a short propagation distance, an asymmetric electron beam drives a stable wakefield in a hollow plasma channel that can be both accelerating and focusing for a positron beam. A high charge positron bunch placed at a suitable distance behind the drive bunch can beam-load or flatten the longitudinal wakefield and enhance the transverse focusing force, leading to high efficiency and narrow energy spread acceleration of the positrons. Three-dimensional quasistatic particle-in-cell simulations show that an over 30% energy extraction efficiency from the wake to the positrons and a 1% level energy spread can be simultaneously obtained. Further optimization is feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PRESERVATION OF THE HIGH QUALITY FACTOR AND ACCELERATING GRADIENT OF Nb3Sn-COATED CAVITY DURING PAIR ASSEMBLY

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

Eremeev, G.V.↗