Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

Holekamp, Kara↗

MAMS - A high spatial resolution multispectral scanner

The Multispectral Atmospheric Mapping Sensor (MAMS) is an airborne scanner which collects imagery in eight visible and three IR bands, with ground resolution of 100 m at a nominal aircraft altitude of 20 km. The visible channels provide continuous spectral coverage from 0.42 to 1.05 microns, and the IR channels measure upwelling and reflected radiation at combinations of 3.7, 6.5, 11.1, and 12.5 microns. These include channels nearly identical to the Landsat TM channels 1-4, and similar to those on the VISSR Atmospheric Sounder (VAS) and AVHRR instruments. The high spatial resolution permits investigation of surface thermal and atmospheric water vapor structure at scales not available from current stabilities. Significant modifications have been made since engineering flights in 1985 to improve the radiometric performance. The increased data quality and recent multidisciplinary applications of this data are presented.

Atkinson, Robert J.↗

Fe 3+ /Fe T ratios of amphiboles determined by high spatial resolution single-crystal synchrotron Mössbauer spectroscopy

The Fe 3+ /Fe T ratios (Fe 3+ /[Fe 2+ +Fe 3+ ]) in minerals can be used to understand their crystallization and post-crystallization conditions. However, as natural minerals are often zoned and contain inclusions, bulk techniques, e.g., wet chemistry, may not provide accurate Fe 3+ /Fe T values for a single phase of interest. We determined Fe 3+ /Fe T ratios of amphiboles in different crystallographic orientations by single-crystal synchrotron Mössbauer spectroscopy (SMS) in energy and time domain modes from four volcanic localities (Long Valley Caldera, Mount St. Helens, Lassen Volcanic Center, U.S.A., and Mt. Pinatubo, Philippines). The high spatial resolution (as low as 12 × 12 μm spot size) and standard-free nature of SMS allow the detection of intra-grain compositional heterogeneities in Fe 3+ /Fe T with relatively low uncertainties. Here, we combine SMS with major element compositions, water contents, and hydrogen isotope compositions to document the Fe 3+ /Fe T ratios as a function of mineral composition and post-crystallization dehydrogenation. Spectra were fitted with up to five distinct sites: ferrous iron on M(1), M(2), M(3), and ferric iron on M(2) and M(3), consistent with X-ray diffraction studies on single crystals of amphibole. The Fe 3+ /Fe T ratios range from 0.14 ± 0.03 (Long Valley Caldera), 0.51 to 0.63 ± 0.02 (representing intra-grain heterogeneities, Mount St. Helens) to 0.86 ± 0.03 (Lassen Volcanic Center). The latter grain experienced post-crystallization dehydrogenation, shown by its low water content (0.6 ± 0.05 wt%) and its elevated hydrogen isotope composition (δD = +25 ± 3‰ relative to SMOW). The Fe 3+ /Fe T ratios of 0.62 ± 0.01 and 0.20 ± 0.01 of two Mt. Pinatubo grains correlate with high-Al 2 O 3 cores and low-Al 2 O 3 rims and smaller phenocrysts in the sample, respectively. This study shows that SMS is capable of distinguishing two different domains with dissimilar Fe 3+ /Fe T values formed under different crystallization conditions, demonstrating that SMS in combination with major element, water, and hydrogen isotope compositions allows the interpretation of amphibole Fe 3+ /Fe T ratios in the context of crystallization and post-crystallization processes.

47 OTHER INSTRUMENTATION↗

A High Spatial Resolution Study of Far IR Emission of Galaxies

This grant funded observations and data reduction on the Kuiper Airborne Observatory. The research project was successfully completed. New insights into the distribution of far infrared emission across star-forming galaxies was obtained, and student training was achieved. The efforts contributed towards new observing strategies that will impact future NASA missions. The results of the effort have been presented in several papers in the refereed literature, including: "Morphology of Far Infrared Emission in Galaxies". "Far Infrared Thermal Emission from the Inner Cooling Flow Region of NGC1275". "Distribution of Light in the'Dusty-Hand'Galaxy NGC2146". Presentations of the results of this program have also been given at the following meetings and symposia: "High Spatial Resolution Study of the Active Cooling Flow Galaxy NGC 1275" "The Extent of Far IR Emission in Luminous Galaxies".

Lester, Dan↗

Atmospheric Correction of High-Spatial-Resolution Commercial Satellite Imagery Products Using MODIS Atmospheric Products

Remotely sensed ground reflectance is the basis for many inter-sensor interoperability or change detection techniques. Satellite inter-comparisons and accurate vegetation indices such as the Normalized Difference Vegetation Index, which is used to describe or to imply a wide variety of biophysical parameters and is defined in terms of near-infrared and redband reflectance, require the generation of accurate reflectance maps. This generation relies upon the removal of solar illumination, satellite geometry, and atmospheric effects and is generally referred to as atmospheric correction. Atmospheric correction of remotely sensed imagery to ground reflectance, however, has been widely applied to only a few systems. In this study, we atmospherically corrected commercially available, high spatial resolution IKONOS and QuickBird imagery using several methods to determine the accuracy of the resulting reflectance maps. We used extensive ground measurement datasets for nine IKONOS and QuickBird scenes acquired over a two-year period to establish reflectance map accuracies. A correction approach using atmospheric products derived from Moderate Resolution Imaging Spectrometer data created excellent reflectance maps and demonstrated a reliable, effective method for reflectance map generation.

Pagnutti, Mary↗

Sputter-Coated Metal Screening for Small Molecule Analysis and High-Spatial Resolution Imaging in Laser Desorption Ionization Mass Spectrometry

Nanoparticles are efficient matrices in laser desorption/ionization (LDI) mass spectrometry (MS), especially for the profiling or imaging of small molecules. Recently, solvent-free physical vapor desorption (PVD), or sputter coating, was adopted as a homogenous method to rapidly apply metal nanoparticles (NPs) in situ to samples prior to LDI MS or MS imaging analysis. However, there has been no systematic study comparing different metal targets for the analysis of a variety of small molecule metabolites. Here, we present a screening and optimization of various sputter-coated metals, including Ag, Au, Cu, Pt, Ni, and Ti, for LDI analysis of small molecules in both positive and negative ion modes. Optimized sputter coating is then applied to high-spatial resolution LDI mass spectrometry imaging (MSI) of maize root and seed cross-sections. Noble metals, Ag, Au, and Pt, are found to be much more efficient than transition metals and organic matrices for most small metabolites. Sputter-coated metals are efficient for neutral lipids, such as triacylglycerols and diacylglycerols, but are very inefficient for most phospholipids. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Spatial-Resolution Quantitative Chemomechanical Mapping of Organic Composite Cathodes for Sulfide-Based Solid-State Batteries

Understanding the chemo-mechanical behaviors of electrodes, particularly at the electrode/electrolyte interfaces, is critical for improving the performance of all-solid-state batteries. However, due to the instability of electrolyte materials under ambient conditions, such characterizations are challenging, particularly for sulfide-based all-solid-state batteries. Herein, by combining time-of-flight secondary-ion mass spectroscopy (ToF-SIMS) and in-SEM nanoindentation measurements, a systematic quantitative investigation of the chemo-mechanical behaviors of pyrene-4,5,9,10-tetraone (PTO) /Li 6 PS 5 Cl composite cathodes is carried out. Chemical and quantitative mechanical information of the composite cathode were collected with high spatial resolution after developing and implementing an air-free characterization protocol. By directly connecting the Young’s modulus and hardness with the Li distribution in the composite cathode, a comprehensive chemo-mechanical mapping of the PTO/ Li 6 PS 5 Cl composite cathode has been established. Furthermore, this work improves our knowledge of the critical chemo-mechanical phenomena that occur at the cathode/electrolyte interfaces in all-solid-state batteries.

25 ENERGY STORAGE↗

Research Relative to High Spatial Resolution Passive Microwave Sounding Systems

Methods to obtain high resolution passive microwave weather observations, and understanding of their probable impact on numerical weather prediction accuracy were investigated. The development of synthetic aperture concepts for geosynchronous passive microwave sounders were studied. The effects of clouds, precipitation, surface phenomena, and atmospheric thermal fine structure on a scale of several kilometers were examined. High resolution passive microwave sounders (e.g., AMSU) with an increased number of channels will produce initialization data for numerical weather prediction (NWP) models with both increased spatial resolution and coverage. The development of statistical models for error growth in high resolution primitive equation NWP models which permit the consequences of various observing system alternatives, including sensors and assimilation times and procedures is discussed. A high resolution three dimensional primitive equation NWP model to determine parameters in an error growth model similar to that formulated by Lorenz, but with more degrees of freedom is utilized.

Staelin, D. H.↗

High spatial resolution continuum and H-alpha imaging of the high-redshift IRAS source FSC 10214+4724

New observations are reported which support the view that the high-redshift IRAS source FSC 10214+4724 is a rare extreme example of the class of ultraluminous infrared galaxies observed in the local universe. The presence of two continuum components and a compact H-alpha source suggests that a merger between two or more gas-rich systems has triggered the production of a powerful dust-enshrouded quasar which is responsible for the bulk of the luminosity.

Soifer, B. T.↗

High-Spatial-Resolution Mass Rates From GRACE and GRACE-FO: Global and Ice Sheet Analyses

GRACE and GRACE-FO gravimetry data are unique in its ability to observe global water mass variability and has frequently been applied for the determination of global mass rates to quantify the impacts of climate change and human activity on global freshwater availability and land ice evolution. However, its relatively coarse spatial resolution of ∼300-500 km at monthly intervals precludes its direct use to measure mass changes in smaller drainage basins and individual glacier systems. We present a new global high resolution mascon product that improves spatial resolution and signal recovery by estimating trends directly from more than 16 years of Level 1B GRACE and GRACE-FO data. We compare this product to independent gravimetry spherical harmonic trend estimates and to ice sheet mass rates derived from ICESat and ICESat-2 laser altimetry. We demonstrate enhanced global signal recovery and improved agreement with ICESat/ ICESat-2 and discuss likely causes for the remaining discrepancies between the gravimetry and laser altimetry solutions.

Bryant D. Loomis↗

High spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry

Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. In our research, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We further describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues.

59 BASIC BIOLOGICAL SCIENCES↗

Development and operation of a Pr 2 Fe 14 B based cryogenic permanent magnet undulator for a high spatial resolution x-ray beam line

Short period, high field undulators are used to produce hard x-rays on synchrotron radiation based storage ring facilities of intermediate energy and enable short wavelength free electron laser. Cryogenic permanent magnet undulators take benefit from improved magnetic properties of RE 2 Fe 14 B (Rare Earth based magnets) at low temperatures for achieving short period, high magnetic field and high coercivity. Using Pr 2 Fe 14 B instead of Nd 2 Fe 14 B, which is generally employed for undulators, avoids the limitation caused by the spin reorientation transition phenomenon, and simplifies the cooling system by allowing the working temperature of the undulator to be directly at the liquid nitrogen one (77 K). We describe here the development of a full scale (2 m), 18 mm period Pr 2 Fe 14 B cryogenic permanent magnet undulator (U18). The design, construction and optimization, as well as magnetic measurements and shimming at low temperature are presented. In conclusion, the commissioning and operation of the undulator with the electron beam and spectrum measurement using the Nanoscopmium beamline at SOLEIL are also reported.

43 PARTICLE ACCELERATORS↗

Matrix recrystallization for MALDI-MS imaging of maize lipids at high-spatial resolution

Matrix recrystallization is optimized and applied to improve lipid ion signals in maize embryos and leaves. A systematic study was performed varying solvent and incubation time. During this study, unexpected side reactions were found when methanol was used as a recrystallization solvent, resulting in the formation of a methyl ester of phosphatidic acid. Furthermore, using an optimum recrystallization condition with isopropanol, there is no apparent delocalization demonstrated with a transmission electron microscopy (TEM) pattern and maize leaf images obtained at 10 μm spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Fiber Sensors With High Spatial Resolution in Extreme Radiation Environments in Nuclear Reactor Cores

This paper is a comprehensive experimental report on the neutron radiation effects of distributed optical fiber sensors with enhanced Rayleigh scattering profiles in an in-pile environment. Femtosecond laser direct writing was used to inscribe Type-II modifications in standard telecom fibers and radiation-hardened fibers with fluorine-doped cores. Rayleigh backscattering signals were enhanced for continuous 1.5 m. In-pile lead-out sensors tests were carried out at the MIT Research Reactor for two months, which was operated at a nominal power of 5.7 MW with fast neutron (>0.1 MeV) flux of 1.29 × 1014 n/cm2/s and an in-core temperature of up to 560°C. Using the Optical Frequency Domain Reflectometry technique, the backscattering profiles of fiber sensors were interrogated with a 3-cm spatial resolution to monitor the temperature profile of the reactor. Results show that laser inscribed Type-II modifications in the form of nanogratings are highly stable against extreme temperature and ionizing radiation. Both standard telecom fibers and radiation-hardened fibers with laser-enhanced Rayleigh profiles can continuously perform distributed temperature measurements over the entire duration of the in-pile testing. Temperature coefficients of sensors and spectral shift quality were studied as functions of total radiation fluence. To the best of our knowledge, we present for the first time, the temperature profile of an operating nuclear reactor core with 3-cm spatial resolution, enabled by distributed fiber sensors with laser-enhanced Rayleigh scattering profiles. The high spatial resolution measurements can provide valuable data for the design and validation of digital twin and virtual reality of nuclear energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spectroscopy-based isotopic (δ 13 C) analysis for high spatial resolution of carbon exchange in the rhizosphere

The rhizosphere is a highly dynamic zone bridging plant roots with needed nutrient resources in soil. While the rhizosphere may be small, it has a disproportionally large impact on plant success and biomass production. A suite of rhizosphere-hosted microbial and geochemical interactions facilitate nutrient acquisition by plant roots, and, in turn, the roots stimulate these processes by supplying organic carbon into the rhizosphere. The small physical dimensions of the rhizosphere, however, can constrain efforts to elucidate key carbon exchange processes and their spatial extent and localization. We present a method for spatially resolved δ 13 C analysis of rhizosphere samples by coupling laser ablation (LA) sampling with isotopic analysis using capillary absorption spectroscopy (CAS) which differs from conventional mass spectrometer (MS) approaches. The CAS system has high sensitivity (requires fewer nanomoles of CO 2 per analysis) than comparable MS systems, which enables reduced sample size requirements to thereby improve spatial resolution (from 25 μm to as low as a projected 5 μm spatial resolution). We demonstrate the utility of CAS using rhizosphere samples from switchgrass plants exposed to 13 CO 2 . As a result, this technique will provide a capability for tracking the extent and spatial distribution of root exudate into the rhizosphere at highly detailed spatial scales.

59 BASIC BIOLOGICAL SCIENCES↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Using High Spatial Resolution Satellite Imagery to Map Forest Burn Severity Across Spatial Scales in a Pine Barrens Ecosystem

As a primary disturbance agent, fire significantly influences local processes and services of forest ecosystems. Although a variety of remote sensing based approaches have been developed and applied to Landsat mission imagery to infer burn severity at 30 m spatial resolution, forest burn severity have still been seldom assessed at fine spatial scales (less than or equal to 5 m) from very-high-resolution (VHR) data. We assessed a 432 ha forest fire that occurred in April 2012 on Long Island, New York, within the Pine Barrens region, a unique but imperiled fire-dependent ecosystem in the northeastern United States. The mapping of forest burn severity was explored here at fine spatial scales, for the first time using remotely sensed spectral indices and a set of Multiple Endmember Spectral Mixture Analysis (MESMA) fraction images from bi-temporal - pre- and post-fire event - WorldView-2 (WV-2) imagery at 2 m spatial resolution. We first evaluated our approach using 1 m by 1 m validation points at the sub-crown scale per severity class (i.e. unburned, low, moderate, and high severity) from the post-fire 0.10 m color aerial ortho-photos; then, we validated the burn severity mapping of geo-referenced dominant tree crowns (crown scale) and 15 m by 15 m fixed-area plots (inter-crown scale) with the post-fire 0.10 m aerial ortho-photos and measured crown information of twenty forest inventory plots. Our approach can accurately assess forest burn severity at the sub-crown (overall accuracy is 84% with a Kappa value of 0.77), crown (overall accuracy is 82% with a Kappa value of 0.76), and inter-crown scales (89% of the variation in estimated burn severity ratings (i.e. Geo-Composite Burn Index (CBI)). This work highlights that forest burn severity mapping from VHR data can capture heterogeneous fire patterns at fine spatial scales over the large spatial extents. This is important since most ecological processes associated with fire effects vary at the less than 30 m scale and VHR approaches could significantly advance our ability to characterize fire effects on forest ecosystems.

Meng, Ran↗