Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulating the X-Ray Image Contrast to Set-Up Techniques with Desired Flaw Detectability

The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is being developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing X-ray detector resolution for crack detection. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

Koshti, Ajay M.↗

ESTIMATES OF THE PLANET YIELD FROM GROUND-BASED HIGH-CONTRAST IMAGING OBSERVATIONS AS A FUNCTION OF STELLAR MASS

We use Monte Carlo simulations to estimate the number of extrasolar planets that are directly detectable in the solar neighborhood using current and forthcoming high-contrast imaging instruments. Our calculations take into consideration the important factors that govern the likelihood for imaging a planet, including the statistical properties of stars in the solar neighborhood, correlations between star and planet properties, observational effects, and selection criteria. We consider several different ground-based surveys, both biased and unbiased, and express the resulting planet yields as a function of stellar mass. Selecting targets based on their youth and visual brightness, we find that strong correlations between star mass and planet properties are required to reproduce high-contrast imaging results to date (i.e., HR 8799, {beta} Pic). Using the most recent empirical findings for the occurrence rate of gas-giant planets from radial velocity (RV) surveys, our simulations indicate that naive extrapolation of the Doppler planet population to semimajor axes accessible to high-contrast instruments provides an excellent agreement between simulations and observations using present-day contrast levels. In addition to being intrinsically young and sufficiently bright to serve as their own beacon for adaptive optics correction, A-stars have a high planet occurrence rate and propensity to form massive planets in wide orbits, making them ideal targets. The same effects responsible for creating a multitude of detectable planets around massive stars conspire to reduce the number orbiting low-mass stars. However, in the case of a young stellar cluster, where targets are approximately the same age and situated at roughly the same distance, MK-stars can easily dominate the number of detections because of an observational bias related to small number statistics. The degree to which low-mass stars produce the most planet detections in this special case depends upon whether multiple formation mechanisms are at work. Upon relaxing our assumption that planets in ultra-wide (a > 100 AU) orbits resemble the RV sample, our simulations suggest that the companions found orbiting late-type stars (AB Pic, 1RXSJ1609, GSC 06214, etc.) are consistent with a formation channel distinct from that of RV planets. These calculations explain why planets have thus far been imaged preferentially around A-stars and K-, M-stars, but no spectral types in between, despite concerted efforts targeting F-, G-stars.

79 ASTRONOMY AND ASTROPHYSICS↗

High aspect ratio anisotropic silicon etching for x-ray phase contrast imaging grating fabrication

Lab based x-ray phase contrast imaging (XPCI) systems have historically focused on medical applications, but there is growing interest in material science applications for non-destructive analysis of low density materials. Extending this imaging technique to higher density materials or larger samples requires higher aspect ratio gratings, to allow the use of a higher energy x-ray source. Here, we demonstrate the use of anisotropic silicon (Si) etching in potassium hydroxide (KOH), to achieve extremely high aspect ratio gratings. This method has been shown to be effective in fabricating deep, uniform gratings by taking advantage of the etch selectivity of differing crystalline planes of silicon. Our work has introduced a method for determining Si crystalline plane directions, specific to (110) Si wafers, enabling high alignment accuracy of the etch mask to these crystalline planes.

36 MATERIALS SCIENCE↗

Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The trends high-contrast imaging survey. IV. The occurrence rate of giant planets around M dwarfs

Doppler-based planet surveys have discovered numerous giant planets but are incomplete beyond several AU. At larger star-planet separations, direct planet detection through high-contrast imaging has proven successful, but this technique is sensitive only to young planets and characterization relies upon theoretical evolution models. Here we demonstrate that radial velocity measurements and high-contrast imaging can be combined to overcome these issues. The presence of widely separated companions can be deduced by identifying an acceleration (long-term trend) in the radial velocity of a star. By obtaining high spatial resolution follow-up imaging observations, we rule out scenarios in which such accelerations are caused by stellar binary companions with high statistical confidence. We report results from an analysis of Doppler measurements of a sample of 111 M-dwarf stars with a median of 29 radial velocity observations over a median time baseline of 11.8 yr. By targeting stars that exhibit a radial velocity acceleration ({sup t}rend{sup )} with adaptive optics imaging, we determine that 6.5% ± 3.0% of M-dwarf stars host one or more massive companions with 1 < m/M{sub J} < 13 and 0 < a < 20 AU. These results are lower than analyses of the planet occurrence rate around higher-mass stars. We find the giant planet occurrence rate is described by a double power law in stellar mass M and metallicity F ≡ [Fe/H] such that f(M,F)=0.039{sub −0.028}{sup +0.056}M{sup 0.8{sub −}{sub 0}{sub .}{sub 9}{sup +{sup 1{sup .{sup 1}}}}}10{sup (3.8±1.2)F}. Our results are consistent with gravitational microlensing measurements of the planet occurrence rate; this study represents the first model-independent comparison with microlensing observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Benchmarking the x-ray phase contrast imaging for ICF DT ice characterization using roughened surrogates

We use x-ray phase contrast imaging to characterize the inner surface roughness of DT ice layers in capsules planned for future ignition experiments. It is therefore important to quantify how well the x-ray data correlates with the actual ice roughness. We benchmarked the accuracy of our system using surrogates with fabricated roughness characterized with high precision standard techniques. Cylindrical artifacts with azimuthally uniform sinusoidal perturbations with 100 um period and 1 um amplitude demonstrated 0.02 um accuracy limited by the resolution of the imager and the source size of our phase contrast system. Spherical surrogates with random roughness close to that required for the DT ice for a successful ignition experiment were used to correlate the actual surface roughness to that obtained from the x-ray measurements. When comparing average power spectra of individual measurements, the accuracy mode number limits of the x-ray phase contrast system benchmarked against surface characterization performed by Atomic Force Microscopy are 60 and 90 for surrogates smoother and rougher than the required roughness for the ice. These agreement mode number limits are >100 when comparing matching individual measurements. We will discuss the implications for interpreting DT ice roughness data derived from phase-contrast x-ray imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diamond Turned High Precision PIAA Optics and Four Mirror PIAA System for High Contrast Imaging of Exo-planets

Off-axis, high-sag PIAA optics for high contrast imaging present challenges in manufacturing and testing. With smaller form factors and consequently smaller surface deformations (< 80 microns), diamond turned fabrication of these mirrors becomes feasible. Though such a design reduces the system throughput, it still provides 2(lambda)D inner working angle. We report on the design, fabrication, measurements, and initial assessment of the novel PIAA optics in a coronagraph testbed. We also describe, for the first time, a four mirror PIAA coronagraph that relaxes apodizer requirements and significantly improves throughput while preserving the low-cost benefits.

coronagraphy↗

X-ray Phase Contrast Imaging of Calcified Tissue and Biomaterial Structure in Bioreactor Engineered Tissues

Tissues engineered in bioreactor systems have been used clinically to replace damaged tissues and organs. In addition, these systems are under continued development for many tissue engineering applications. The ability to quantitatively assess material structure and tissue formation is critical for evaluating bioreactor efficacy and for preimplantation assessment of tissue quality. These techniques allow for the nondestructive and longitudinal monitoring of large engineered tissues within the bioreactor systems and will be essential for the translation of these strategies to viable clinical therapies. X-ray Phase Contrast (XPC) imaging techniques have shown tremendous promise for a number of biomedical applications owing to their ability to provide image contrast based on multiple X-ray properties, including absorption, refraction, and scatter. In this research, mesenchymal stem cell-seeded alginate hydrogels were prepared and cultured under osteogenic conditions in a perfusion bioreactor. The constructs were imaged at various time points using XPC microcomputed tomography (µCT). Imaging was performed with systems using both synchrotron- and tube-based X-ray sources. XPC µCT allowed for simultaneous three-dimensional (3D) quantification of hydrogel size and mineralization, as well as spatial information on hydrogel structure and mineralization. Samples were processed for histological evaluation and XPC showed similar features to histology and quantitative analysis consistent with the histomorphometry. Furthermore, these results provide evidence of the significant potential of techniques based on XPC for noninvasive 3D imaging engineered tissues grown in bioreactors.

alginate microbeads↗

First refraction contrast imaging via Laser-Compton Scattering X-ray at KEK

Laser-Compton Scattering (LCS) is one of the most feasible techniques for high quality, high brightness, and compact X-ray source. High energy electron beam produced by accelerators scatters off the laser photon at a small spot. As a laser target, we have been developing a pulsedlaser storage cavity for increasing an X-ray flux. The X-ray flux was still inadequate that was 2.1 Multiplication-Sign 10{sup 5}/sec, however, we performed first refraction contrast imaging in order to evaluate the quality of LCS X-ray. Edge enhanced contrast imaging was achieved by changing the distance from sample to detector. The edge enhancement indicates that the LCS X-ray has small source size, i.e. high brightness. We believe that the result has demonstrated good feasibility of linac-based high brightness X-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

Low-Cost High-Precision PIAA Optics for High Contrast Imaging with Exo-Planet Coronagraphs

PIAA optics for high contrast imaging present challenges in manufacturing and testing due to their large surface departures from aspheric profiles at the aperture edges. With smaller form factors and consequent smaller surface deformations (<50 microns), fabrication of these mirrors with diamond turning followed by electron beam lithographic techniques becomes feasible. Though such a design reduces the system throughput to approx.50%, it still provides good performance down to 2 lambda/D inner working angle. With new achromatic focal plane mask designs, the system performance can be further improved. We report on the design, expected performance, fabrication challenges, and initial assessment of such novel PIAA optics.

pupil remapping↗

Performance Sensitivity Studies on the PIAA Implementation of the High-Contrast Imaging Testbed

We have investigated the dependence of the High Contrast Imaging Testbed (HCIT) Phase Induced Amplitude Apodization (PIAA) coronagraph system performance on the rigid-body perturbations of various optics. The structural design of the optical system as well as the parameters of various optical elements used in the analysis are drawn from those of the PIAA/HCIT system that have been and will be implemented, and the simulation takes into account the surface errors of various optics. In this paper, we report our findings when the input light is a narrowband beam.

pupil mapping↗

X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A continuous kilohertz Cu K{alpha} source produced by submillijoule femtosecond laser pulses for phase contrast imaging

We report a continuously operated Cu K{alpha} x-ray source produced by a commercial kilohertz submillijoule femtosecond laser system. The source has an x-ray conversion of {approx}4x10{sup -5} into K{alpha} line emission at 8.05 keV. The microplasma x-ray source has a size of 8 {mu}m (full width at half maximum) produced by focusing 260 {mu}J laser pulses on a moving Cu-wire target. An average photon flux of {approx}1.1x10{sup 9} photons/sr/s is obtained using the above laser pulses. The source has been used to record phase contrast images of test samples. This compact x-ray source can serve as a low cost operating system for phase contrast imaging in clinical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning hard x-ray differential phase contrast imaging with a double wedge absorber

Two-directional differential phase contrast images were measured using an x-ray microbeam and a double wedge absorber. The wedge absorber converts the displacement of an x-ray beam that is refracted by an object into change of x-ray intensity. The double wedge absorber made it possible to detect values of two-directional refraction angle with {mu}rad sensitivity simultaneously. By Fourier integration of two-directional phase gradients calculated from the refraction angle instead of line integration of one-directional phase gradients, we obtained a quantitative phase map without artifacts even when only a part of the boundaries of the object were in the field of view. One of the characteristics of this technique is flexibility in a sensitivity of the phase gradient. By changing of shape or material of the wedge absorber, it is comparatively easy to control the detection limit of the refraction angle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of X-ray phase contrast imaging system toward high-sensitivity measurements of biological organs

X-ray phase contrast imaging and tomography using a Talbot grating interferometer is currently available for user experiments at BL20B2 in SPring-8. The measurement condition for X-ray phase contrast tomography has been optimized to achieve high-sensitivity measurements of biological soft tissues and organs. Some biological samples were measured to demonstrate the high-sensitivity imaging.

60 APPLIED LIFE SCIENCES↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

A New Integral Field Spectrograph for Broadband Coronagraph Demonstrations at the High Contrast Imaging Testbed Facility

An integral field spectrograph (IFS) camera may help fulfill the exoplanet characterization goals of a future Habitable Worlds Observatory. During the Nancy Grace Roman Space Telescope mission formulation phase, the Coronagraph Instrument Project established the laboratory performance baseline of a combined coronagraph and IFS system with the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES; 1E-8 contrast over an 18% bandpass; 3--9 lambda/D bowtie-shaped control region). New laboratory demonstrations are needed to expand on this milestone in terms of contrast, bandpass, and field of view towards the requirements of a future mission capable of characterizing the atmospheres of Earth-like exoplanets. Here we present the design of a successor to PISCES that can observe a 20 lambda/D-diameter field of view with an instantaneous bandpass up to 30%, at a resolving power R > 70 at visible wavelengths. This instrument will interface with the existing coronagraph layout in the High Contrast Imaging Facility DST-2 vacuum chamber. The addition of a spectroscopic imaging camera at HCIT will benefit the wider coronagraph technology community by enabling other NASA-supported investigators to automatically obtain multi-wavelength measurements of speckles both inside and outside of their control region, and the instrument will support community-led demonstrations of high-order wavefront sensing and control techniques such as dark hole maintenance and linear dark field control.

coronagraph↗