Isospin mixing and the cubic isobaric multiplet mass equation in the lowest T=2, A=32 quintet

The isobaric multiplet mass equation (IMME) is known to break down in the first T=2,A=32 isospin quintet. In this work we combine high-resolution experimental data with state-of-the-art shell-model calculations to investigate isospin mixing as a possible cause for this violation. The experimental data are used to validate isospin-mixing matrix elements calculated with newly developed shell-model Hamiltonians. Our analysis shows that isospin mixing with nonanalog T=1 states contributes to the IMME breakdown, making the requirement of an anomalous cubic term inevitable for the multiplet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass of {sup 23}Al for testing the isobaric multiplet mass equation

The mass excess of the proton-rich nucleus {sup 23}Al has been measured with the JYFLTRAP Penning trap setup. As a result of our experiment we obtain a mass excess of 6748.07(34) keV, and by combining the value to existing experimental data we have tested the validity of the isobaric multiplet mass equation (IMME) for the T=3/2 quartet in the A=23 isobar. The fit to the IMME results in a vanishing cubic term equivalent to zero with high precision [0.22(42) keV].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision mass measurements of magnesium isotopes and implications for the validity of the isobaric mass multiplet equation

If the mass excess of neutron-deficient nuclei and their neutron-rich mirror partners are both known, it can be shown that deviations of the isobaric mass multiplet equation (IMME) in the form of a cubic term can be probed. Such a cubic term was probed by using the atomic mass of neutron-rich magnesium isotopes measured using the TITAN Penning trap and the recently measured proton-separation energies of 29 Cl and 30 Ar. The atomic mass of 27 Mg was found to be within 1.6σ of the value stated in the Atomic Mass Evaluation. The atomic masses of 28,29 Mg were measured to be both within 1σ, while being 7 and 33 times more precise, respectively. Using the 29 Mg mass excess and previous measurements of 29 Cl, we uncovered a cubic coefficient of d = 28(7)keV, which is the largest known cubic coefficient of the IMME. This departure, however, could also be caused by experimental data with unknown systematic errors. Hence there is a need to confirm the mass excess of 28 S and the one-neutron separation energy of 29 Cl, which have both come from a single measurement. Lastly, our results were compared with ab initio calculations from the valence-space in-medium similarity renormalization group, resulting in a good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Synchrotron Radiation Study of the One-dimensional Complex of Sodium with (1S)-N-carboxylato-1-(9-deazaadenin-9-yl)-1,4-dideoxy-1,4-imino-D-ribitol, a Member of the ’immucillin’ Family

The sodium salt of [immucillin-A-CO{sub 2}H]{sup -} (Imm-A), namely catena-poly[[[triaquadisodium(I)]({mu}-aqua)[{mu}-(1S)-N-carboxylato-1-(9-deazaadenin-9-yl)-1,4-dideoxy-1,4-imino-D-ribitol][triaquadisodium(I)][{mu}-(1S)-N-carboxylato-1-(9-deazaadenin-9-yl)-1,4-dideoxy-1,4-imino-D-ribitol]] tetrahydrate], {l_brace}[Na{sub 2}(C{sub 12}H{sub 13}N{sub 4}O{sub 6}){sub 2}(H{sub 2}O){sub 7}] {center_dot} 4H{sub 2}O{r_brace}n, (I), forms a polymeric chain via Na{sup +}-O interactions involving the carboxylate and keto O atoms of two independent Imm-A molecules. Extensive N,O-H...O hydrogen bonding utilizing all water H atoms, including four waters of crystallization, provides crystal packing. The structural definition of this novel compound was made possible through the use of synchrotron radiation utilizing a minute fragment (volume {approx}2.4 x 10{sup -5} mm{sup -3}) on a beamline optimized for protein data collection. A summary of intra-ring conformations for immucillin structures indicates considerable flexibility while retaining similar intra-ring orientations.

08 HYDROGEN↗

Highly Transparent Compositionally Graded Buffers for New Metamorphic Multijunction Solar Cell Designs

The development of compositionally graded buffer layers (CGBs) with enhanced transparency would enable novel five and six junction solar cells, with efficiencies approaching 50% under high concentration. Here, we demonstrate highly transparent grades between the GaAs and InP lattice constants on both A- and B-miscut GaAs substrates, employing Al x GayIn 1-x-y As and highly Se-doped Burstein-Moss (BM) shifted Ga x In 1-x P. Transparency to >810 and >890 nm wavelengths is demonstrated with BM-shifted Ga x In 1-x P on B-miscut substrates and Al x GayIn 1-x-y As/Ga x In 1-x P(Se) combined grades on A-miscut substrates, respectively. 0.74 eV GaInAs solar cells grown on these transparent CGBs exhibit Woc = 0.41 V at mA/ cm 2 , performance comparable with the state-of-the-art Ga x In 1-x P grade employed in the four-junction-inverted metamorphic multijunction (IMM) cell. A GaAs/0.74cV GaInAs tandem cell was grown with a transparent BM-shifted Ga x In 1-x P CGB to verify the CGB performance in a multijunction device structure. Quantum efficiency measurements indicate that the CGB is completely transparent to photons below the GaAs bandedge, validating its use in 4-6 junction IMM devices with a single-graded buffer. Furthermore, this tandem represents a highly efficient two-junction band gap combination, achieving 29.6% ± 1.2% efficiency under the AM1.5 global spectrum, demonstrating how the additional transparency enables new device structures.

14 SOLAR ENERGY↗

Internal Resistive Barriers Related to Zinc Diffusion During the Growth of Inverted Metamorphic Multijunction Solar Cells

Majority carrier barriers at heterointerfaces are a common source of non-linear resistance that hinders concentrator solar cell performance. The source of a particular barrier is often unclear in a multijunction device with numerous heterointerfaces. In this work, we demonstrate Zn-dopant diffusion during inverted metamorphic multijunction (IMM) device growth to be one key cause of internal barrier formation. Using an inverted GaAs/GaAs tandem solar cell with a high temperature annealing layer grown in between each subcell, we simulate the annealing conditions of a multijunction growth in a simplified structure. Through analysis of the device by secondary ion mass spectrometry (SIMS) and electrochemical capacitance-voltage profiling, we show that annealing causes Zn to diffuse out of the top cell Ga 0.5 In 0.5 P back surface field (BSF) and accumulate in the GaAs base. Through equilibrium band modeling, we show that the resultant doping profile forms an energetic barrier to hole flow in the valence band, which correlates with fill factor losses in the current-voltage curves measured under concentration. When we, instead, employ a C-doped Al 0.2 Ga 0.8 As BSF layer in the top cell, we do not observe evidence of a heterojunction barrier. We attribute this difference to the reduced diffusivity of carbon, confirmed by SIMS, as well as more favorable valence band offsets between GaAs and Al 0.2 Ga 0.8 As. Finally, we compare 5-junction IMM cells with Al 0.2 Ga 0.8 As:C and Ga 0.5 In 0.5 P:Zn BSF layers in the GaAs third junction, respectively, and show a significantly improved concentrator device performance when Al 0.2 Ga 0.8 As:C is employed. Lastly, we demonstrate the importance of designing annealing tolerance into multijunction structures that are subjected to extended annealing during growth.

14 SOLAR ENERGY↗

Photo-Electrochemical Hydrogen Generation from Inverted Metamorphic Multijunction III-Vs

Our goal is to improve solar-to-hydrogen (STH) efficiency from just over 10% to over 20% via novel tandem semiconductor materials and configurations. Our primary focus is to develop inverted metamorphic multijunction (IMM) III-V semiconductors that have bandgaps optimized for water splitting. We will also discuss measurement challenges in appraising STH efficiency, some of which are specific to tandem absorbers. Using more stringent measurement standards, we have confirmed 16.2% STH on our most advanced IMM devices.

14 SOLAR ENERGY↗

Measurements of Six-Junction Concentrator Solar Cells

Accurate measurements of six-junction inverted metamorphic concentrator solar cells under AM1.5 direct spectrum are obtained by adjusting the spectrum of a tunable high-intensity solar simulator with custom mirrors. Isotype reference cells and broadband InGaAs QE calibration cells were developed for accurate measurements. Modeling and varying the illumination show that an unavoidable 15% - 17% overillumination on the sixth junction does not result in significant error of these 6J IMM devices. Spectrally adjusted flash measurements are independently confirmed by NREL's Cell and Module Performance team. Concentration measurements of a 6J IMM solar cell resulted in 47.1 ± 3.2% (absolute) efficiency at 143 suns.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Collaborative Decision Environment for UAV Operations

NASA is developing Intelligent Mission Management (IMM) technology for science missions employing long endurance unmanned aerial vehicles (UAV's). The IMM groundbased component is the Collaborative Decision Environment (CDE), a ground system that provides the Mission/Science team with situational awareness, collaboration, and decisionmaking tools. The CDE is used for pre-flight planning, mission monitoring, and visualization of acquired data. It integrates external data products used for planning and executing a mission, such as weather, satellite data products, and topographic maps by leveraging established and emerging Open Geospatial Consortium (OGC) standards to acquire external data products via the Internet, and an industry standard geographic information system (GIs) toolkit for visualization As a Science/Mission team may be geographically dispersed, the CDE is capable of providing access to remote users across wide area networks using Web Services technology. A prototype CDE is being developed for an instrument checkout flight on a manned aircraft in the fall of 2005, in preparation for a full deployment in support of the US Forest Service and NASA Ames Western States Fire Mission in 2006.

D'Ortenzio, Matthew V.↗

ECP Bone Workshop Day 2, Session 1: Validation of Exercise Countermeasures

The thesis of this session of the ECP Bone workshop is that computer modeling is required in order to evaluate factor of risk for fracture when considering the uniquely localized bone loss conditions experienced by Astronauts. This session provides an opportunity to introduce the Integrated Medical Model Bone Fracture Risk (IMM-BFxRM) simulation approach and how this and other models improve understanding of the effects of exercise countermeasures. This workshop session also provides an opportunity for the panel to provide recommendations on this and other "complex modeling" approaches, as well as, the importance of funding the IMM-BFxRM and companion efforts by external scientists (Lang and Keyak).

Myers, Jerry G.↗

Estimating the Need for Medical Intervention due to Sleep Disruption on the International Space Station

During ISS and shuttle missions, difficulties with sleep affect more than half of all US crews. Mitigation strategies to help astronauts cope with the challenges of disrupted sleep patterns can negatively impact both mission planning and vehicle design. The methods for addressing known detrimental impacts for some mission scenarios may have a substantial impact on vehicle specific consumable mass or volume or on the mission timeline. As part of the Integrated Medical Model (IMM) task, NASA Glenn Research Center is leading the development of a Monte Carlo based forecasting tool designed to determine the consumables required to address risks related to sleep disruption. The model currently focuses on the International Space Station and uses an algorithm that assembles representative mission schedules and feeds this into a well validated model that predicts relative levels of performance, and need for sleep (SAFTE Model, IBR Inc). Correlation of the resulting output to self-diagnosed needs for hypnotics, stimulants, and other pharmaceutical countermeasures, allows prediction of pharmaceutical use and the uncertainty of the specified prediction. This paper outlines a conceptual model for determining a rate of pharmaceutical utilization that can be used in the IMM model for comparison and optimization of mitigation methods with respect to all other significant medical needs and interventions.

Myers, Jerry G.↗

The Integrated Medical Model

This slide presentation reviews the goals and approach for the Integrated Medical Model (IMM). The IMM is a software decision support tool that forecasts medical events during spaceflight and optimizes medical systems during simulations. It includes information on the software capabilities, program stakeholders, use history, and the software logic.

Butler, Douglas J.↗

The Integrated Medical Model

The goals of the Integrated Medical Model (IMM) are to develop an integrated, quantified, evidence-based decision support tool useful to crew health and mission planners and to help align science, technology, and operational activities intended to optimize crew health, safety, and mission success. Presentation slides address scope and approach, beneficiaries of IMM capabilities, history, risk components, conceptual models, development steps, and the evidence base. Space adaptation syndrome is used to demonstrate the model's capabilities.

Kerstman, Eric↗

Integration of an Evidence Base into a Probabilistic Risk Assessment Model. The Integrated Medical Model Database: An Organized Evidence Base for Assessing In-Flight Crew Health Risk and System Design

This slide presentation reviews the Integrated Medical Model (IMM) database, which is an organized evidence base for assessing in-flight crew health risk. The database is a relational database accessible to many people. The database quantifies the model inputs by a ranking based on the highest value of the data as Level of Evidence (LOE) and the quality of evidence (QOE) score that provides an assessment of the evidence base for each medical condition. The IMM evidence base has already been able to provide invaluable information for designers, and for other uses.

Saile, Lynn↗

Sleep Disruption Medical Intervention Forecasting (SDMIF) Module for the Integrated Medical Model

The NASA Integrated Medical Model (IMM) assesses the risk, including likelihood and impact of occurrence, of all credible in-flight medical conditions. Fatigue due to sleep disruption is a condition that could lead to operational errors, potentially resulting in loss of mission or crew. Pharmacological consumables are mitigation strategies used to manage the risks associated with sleep deficits. The likelihood of medical intervention due to sleep disruption was estimated with a well validated sleep model and a Monte Carlo computer simulation in an effort to optimize the quantity of consumables. METHODS: The key components of the model are the mission parameter program, the calculation of sleep intensity and the diagnosis and decision module. The mission parameter program was used to create simulated daily sleep/wake schedules for an ISS increment. The hypothetical schedules included critical events such as dockings and extravehicular activities and included actual sleep time and sleep quality. The schedules were used as inputs to the Sleep, Activity, Fatigue and Task Effectiveness (SAFTE) Model (IBR Inc., Baltimore MD), which calculated sleep intensity. Sleep data from an ISS study was used to relate calculated sleep intensity to the probability of sleep medication use, using a generalized linear model for binomial regression. A human yes/no decision process using a binomial random number was also factored into sleep medication use probability. RESULTS: These probability calculations were repeated 5000 times resulting in an estimate of the most likely amount of sleep aids used during an ISS mission and a 95% confidence interval. CONCLUSIONS: These results were transferred to the parent IMM for further weighting and integration with other medical conditions, to help inform operational decisions. This model is a potential planning tool for ensuring adequate sleep during sleep disrupted periods of a mission.

Lewandowski, Beth↗

Enterprise Reference Library

Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and duplication costs. Most importantly, increasing collaboration across research groups provides unprecedented access to information relevant to NASA s mission. Conclusion: This project is an expansion and cost-effective leveraging of the existing JSC centralized library. Adding key word and author search capabilities and an alert function for notifications about new articles, based on users profiles, represent examples of future enhancements.

Bickham, Grandin↗

Optimizing Medical Kits for Spaceflight

The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulation outcomes describing the impact of medical events on the mission may be used to optimize the allocation of resources in medical kits. Efficient allocation of medical resources, subject to certain mass and volume constraints, is crucial to ensuring the best outcomes of in-flight medical events. We implement a new approach to this medical kit optimization problem. METHODS We frame medical kit optimization as a modified knapsack problem and implement an algorithm utilizing a dynamic programming technique. Using this algorithm, optimized medical kits were generated for 3 different mission scenarios with the goal of minimizing the probability of evacuation and maximizing the Crew Health Index (CHI) for each mission subject to mass and volume constraints. Simulation outcomes using these kits were also compared to outcomes using kits optimized..RESULTS The optimized medical kits generated by the algorithm described here resulted in predicted mission outcomes more closely approached the unlimited-resource scenario for Crew Health Index (CHI) than the implementation in under all optimization priorities. Furthermore, the approach described here improves upon in reducing evacuation when the optimization priority is minimizing the probability of evacuation. CONCLUSIONS This algorithm provides an efficient, effective means to objectively allocate medical resources for spaceflight missions using the Integrated Medical Model.

Optimization↗