Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A miniaturized neuroprosthesis suitable for implantation into the brain

This paper presents current research on a miniaturized neuroprosthesis suitable for implantation into the brain. The prosthesis is a heterogeneous integration of a 100-element microelectromechanical system (MEMS) electrode array, front-end complementary metal-oxide-semiconductor (CMOS) integrated circuit for neural signal preamplification, filtering, multiplexing and analog-to-digital conversion, and a second CMOS integrated circuit for wireless transmission of neural data and conditioning of wireless power. The prosthesis is intended for applications where neural signals are processed and decoded to permit the control of artificial or paralyzed limbs. This research, if successful, will allow implantation of the electronics into the brain, or subcutaneously on the skull, and eliminate all external signal and power wiring. The neuroprosthetic system design has strict size and power constraints with each of the front-end preamplifier channels fitting within the 400 x 400-microm pitch of the 100-element MEMS electrode array and power dissipation resulting in less than a 1 degree C temperature rise for the surrounding brain tissue. We describe the measured performance of initial micropower low-noise CMOS preamplifiers for the neuroprosthetic.

Action Potentials/physiology↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

Silicon on sapphire for ion implantation studies

Van der Pauw or bridge samples are ultrasonically cut from silicon on sapphire wafers. Contact pad regions are implanted with moderately heavy dose of ions. Ion of interest is implanted into sample; and, before being annealed in vacuum, sample is sealed with sputtered layer of silicon dioxide. Nickel or aluminum is sputtered onto contact pad areas and is sintered in nitrogen atmosphere.

Pisciotta, B. P.↗

A multichannel implantable telemetry system for flow, pressure, and ECG measurements

The design, principles of operation, and performance of an implantable miniaturized (48 cu cm in volume) multiplex telemetry system for simultaneous measurement of up to eight physiological parameters (including cardiovascular data) are described. Integrated circuits are used to reduce the size, complexity, and cost of fabrication. Power consumption is reduced using recently developed complementary MOS devices. PWM technique is selected as it is relatively easy to implement, lends itself to ICs, and provides an accurate means of transmitting data. The system is totally implantable within the chest of a test animal, with no wire penetrating through the skin. It is shown that the described system permits repeated measurement of the physiological effects of a variety of interventions in awake unanesthetized animals.

Fryer, T. B.↗

Mossbauer effect in the ion-implanted iron-carbon alloys

The concentration dependence of Mossbauer effect in four carbon ion-implanted iron absorbers, which contain carbon as the solute atoms, has been investigated over the range of concentration 0.05 through 1 atomic percent. The specimens were prepared by implanting carbon atoms on each reference iron foil with four different bombarding energies of 250 keV, 160 keV, 140 keV and 80 keV, respectively. Thus, the specimen contains a uniform dosage of carbon atoms which penetrated up to 3,000 A depth of the reference iron. In the measurement of Mossbauer spectra, the backscattering conversion electron counting geometry was used. Typical results of Mossbauer parameters of iron-carbon alloys show that the isomer shift, quadrupole shift, the effective hyperfine splitting of Fe-57, and the intensity ratio exhibit a large variation with the increase of carbon concentration in the environment of iron atoms.

Han, K. S.↗

Ion-implantation effect on time-dependent breakdown in SiO2

It was experimentally demonstrated that the field emission of positive ions from the metal SiO2 interface in MOS structures can be controlled by introducing a positive charge in a small ion-implantation dose to a shallow depth below the metal electrode. Considerable improvement of time-dependent breakdown was noted in structures implanted in this manner as opposed to nonimplanted ones. This experiment confirms the model proposed by Li and Maserjian (1975) for radiation effect on time-dependent breakdown.

Li, S. P.↗

Implantable electrode for recording nerve signals in awake animals

An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k ohms at a frequency range of 20-5 kHz. Aortic nerve activity and renal nerve activity, measured in awake conditions using the collagen electrode, showed grouped activity synchronous with the cardiac cycle. Results indicate that most of the renal nerve activity was from postganglionic sympathetic fibers and was inhibited by the baroceptor reflex in the same cardiac cycle.

Ninomiya, I.↗

Percutaneous and skeletal biocarbon implants

Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

Mooney, V.↗

Multichannel implantable telemetry system

Multiplexed biotelemetry system for animal research combines several power-saving features. Implantable sensor measures up to eight parameters simultaneously, including blood flow. Microamp transistors, switching circuits, and CMOS technology are used to lower power requirements. However, when blood flow is monitored, these measures are insufficient to reduce power enough for long-term operation from implantable primary battery.

Fryer, T. B.↗

Batteryless implanted echosonometer

Miniature ultrasonic echosonometer implanted within laboratory animals obtains energy from RF power oscillator that is electronically transduced via induction loop to power receiving loop located just under animal's skin. Method of powering device offers significant advantages over those in which battery is part of implanted package.

Kojima, G. K.↗

Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

Weigand, A. J.↗

Implantable acoustic-beacon automatic fish-tracking system

A portable automatic fish tracking system was developed for monitoring the two dimensional movements of small fish within fixed areas of estuarine waters and lakes. By using the miniature pinger previously developed for this application, prototype tests of the system were conducted in the York River near the Virginia Institute of Marine Science with two underwater listening stations. Results from these tests showed that the tracking system could position the miniature pinger signals to within + or - 2.5 deg and + or - 135 m at ranges up to 2.5 km. The pingers were implanted in small fish and were successfully tracked at comparable ranges. No changes in either fish behavior or pinger performance were observed as a result of the implantation. Based on results from these prototype tests, it is concluded that the now commercially available system provides an effective approach to underwater tracking of small fish within a fixed area of interest.

Mayhue, R. J.↗

More-reliable SOS ion implantations

Conducting layer prevents static charges from accumulating during implantation of silicon-on-sapphire MOS structures. Either thick conducting film or thinner film transparent to ions is deposited prior to implantation, and gaps are etched in regions to be doped. Grounding path eliminates charge flow that damages film or cracks sapphire wafer. Prevention of charge buildup by simultaneously exposing structure to opposite charges requires equipment modifications less practical and more expensive than deposition of conducting layer.

Woo, D. S.↗

Tailored emitter, low-resistivity, ion-implanted silicon solar cells

Open-circuit voltages as high as 0.645 V (AM0, 25 C) have been obtained by a new process developed for low-resistivity silicon. The process utilizes high-dose phosphorus implantation followed by furnace annealing and simultaneous oxide growth. The effect of the thermally grown oxide is a reduction of surface recombination velocity; the oxide also acts as a moderately efficient antireflection (AR) coating. Boron-doped, float-zone silicon with resistivities from 0.1 to 1.0 (omega)(cm) has been processed according to this sequence; results show that the highest open-circuit voltage is obtained with 0.1(omega)(cm) starting material. The effects of Auger recombination and bandgap narrowing caused by high doping concentrations in the n(+)junction region have been investigated by implanting phosphorus over a wide range of dose levels. The effects of emitter-phosphorus concentrations tailored to optimize electric fields in the emitter have also been investigated.

Minnucci, J. A.↗

Ion-implanted laser annealed silicon solar cells

Development of low cost solar cells fabrication technology is being sponsored by NASA JPL as part of the Low Cost Solar Array Project (LSA). In conformance to Project requirements ion implantation and laser annealing were evaluated as junction formation techniques offering low cost-high throughput potential. Properties of cells fabricated utilizing this technology were analyzed by electrical, transmission electron microscopy, Rutherford backscattering and secondary ion mass spectrometry techniques. Tests indicated the laser annealed substrates to be damage free and electrically active. Similar analysis of ion implanted furnace annealed substrates revealed the presence of residual defects in the form of dislocation lines and loops with substantial impurity redistribution evident for some anneal temperature/time regimes. Fabricated laser annealed cells exhibited improved spectral response and conversion efficiency in comparison to furnace annealed cells. An economic projection for LSA indicates a potential for considerable savings from laser annealing technology.

Katzeff, J. S.↗

Passivation of carbon steel through mercury implantation

An experiment, in which carbon steel samples were implanted with mercury ions from a broad beam ion source and their corrosion characteristics in air were evaluated, is described. Mercury doses of a few mA min/square cm at energies of a few hundred electron volts are shown to effect significant improvements in the corrosion resistance of the treated surfaces. In a warm moist environment the onset of rusting was extended from 15 min. for an untreated sample to approximately 30 hrs. for one implanted at a dose of 33 mA min/square cm with 1000 eV mercury ions.

Wilbur, P. J.↗