Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Constraining the Twomey effect from satellite observations: issues and perspectives

Abstract. The Twomey effect describes the radiative forcing associated with a change in cloud albedo due to an increase in anthropogenic aerosol emissions. It is driven by the perturbation in cloud droplet number concentration (ΔNd, ant) in liquid-water clouds and is currently understood to exert a cooling effect on climate. The Twomey effect is the key driver in the effective radiative forcing due to aerosol–cloud interactions, but rapid adjustments also contribute. These adjustments are essentially the responses of cloud fraction and liquid water path to ΔNd, ant and thus scale approximately with it. While the fundamental physics of the influence of added aerosol particles on the droplet concentration (Nd) is well described by established theory at the particle scale (micrometres), how this relationship is expressed at the large-scale (hundreds of kilometres) perturbation, ΔNd, ant, remains uncertain. The discrepancy between process understanding at particle scale and insufficient quantification at the climate-relevant large scale is caused by co-variability of aerosol particles and updraught velocity and by droplet sink processes. These operate at scales on the order of tens of metres at which only localised observations are available and at which no approach yet exists to quantify the anthropogenic perturbation. Different atmospheric models suggest diverse magnitudes of the Twomey effect even when applying the same anthropogenic aerosol emission perturbation. Thus, observational data are needed to quantify and constrain the Twomey effect. At the global scale, this means satellite data. There are four key uncertainties in determining ΔNd, ant, namely the quantification of (i) the cloud-active aerosol – the cloud condensation nuclei (CCN) concentrations at or above cloud base, (ii) Nd, (iii) the statistical approach for inferring the sensitivity of Nd to aerosol particles from the satellite data and (iv) uncertainty in the anthropogenic perturbation to CCN concentrations, which is not easily accessible from observational data. This review discusses deficiencies of current approaches for the different aspects of the problem and proposes several ways forward: in terms of CCN, retrievals of optical quantities such as aerosol optical depth suffer from a lack of vertical resolution, size and hygroscopicity information, non-direct relation to the concentration of aerosols, difficulty to quantify it within or below clouds, and the problem of insufficient sensitivity at low concentrations, in addition to retrieval errors. A future path forward can include utilising co-located polarimeter and lidar instruments, ideally including high-spectral-resolution lidar capability at two wavelengths to maximise vertically resolved size distribution information content. In terms of Nd, a key problem is the lack of operational retrievals of this quantity and the inaccuracy of the retrieval especially in broken-cloud regimes. As for the Nd-to-CCN sensitivity, key issues are the updraught distributions and the role of Nd sink processes, for which empirical assessments for specific cloud regimes are currently the best solutions. These considerations point to the conclusion that past studies using existing approaches have likely underestimated the true sensitivity and, thus, the radiative forcing due to the Twomey effect.

54 ENVIRONMENTAL SCIENCES↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intercomparison of Aerosol Instrumental Responses Using AEROTRAK, SMPS, and APS in a Simulated Building

In this work, three aerosol instruments were intercompared by using data collected from field campaigns in a simulated building environment during the last quarter of 2020 from October to December at Oak Ridge National Laboratory. The three aerosol instruments—AeroTrak Model 9110, Scanning Mobility Particle Spectrometer (SMPS) 3080L + 3025A, and Aerodynamic Particle Sizer (APS) 3320—were manufactured by TSI Inc. to perform in situ measurements of particle number concentration in the air. These instruments were co-located in one room in which an aerosol generator was used to produce a defined aerosol population for the instruments to sample and detect in each campaign. The SMPS measured aerosol particles with diameters from 0.01 to 0.7 µm, APS measured aerosol particles with diameters from 0.5 to 20 µm, and AeroTrak measured aerosol particles with diameters from 0.1 to 10 µm. The results suggest that although AeroTrak is fast and easy to use, it does not provide measurements comparable with those obtained by SMPS and APS. The differences in particle counts were orders of magnitude in size (i.e., the AeroTrak data were unreasonably small in the tested scenarios). The results clearly indicate that AeroTrak should not be used in ambient applications in which the level of particle concentration is expected to be high. This would cause difficulty to a campaign in which the dilution factor is unknow a priori. The high particle concentration could also lead to an erroneous aerosol size distribution (e.g., a bimodal size distribution was measured as opposed to a single-mode one). The number concentration limit that AeroTrak is expected to run reliably (i.e., with a counting coincidence error less than ±10%) is approximately three to four per cubic centimeter. This suggests that the instrument is best used in a clean room environment, not in an ambient or indoor application, such as the Flexible Research Platform campaigns.

47 OTHER INSTRUMENTATION↗

Sources of error in detonation calorimeters and error analysis for neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB)

Here, a calorimeter for measuring heats of detonation at Lawrence Livermore National Laboratory is described. A calibration precision of 0.2 % at the 95 % confidence interval (CI) is reported. Sources of uncertainty are discussed, including nonequivalent sources, which are those arising from differences between calibration and experimental tests. The systematic error due to nonequivalent sources is bounded to 0.19–0.22 % of the measured heat for a standard detonation test where the confinement material is gold. The recommendation is to correct for the systematic error by adding 0.19 % to the reported value and adding 0.03 % to the uncertainty. It is demonstrated that the precision of a detonation test is variable with testing duration because a source of uncertainty resides in the thermodynamic correction factor k6, which accounts for the contribution to heat by stirring; the generated power is additive and therefore highly impacted by total test time. The relative proportion also varies with the magnitude of heat release and sample size, adding variance to the weight of the error arising from the correction factor. A full error analysis based on the described sources of uncertainty is developed. The methodology is applied to a test series on neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB), demonstrating an ultimate precision of 0.7 % (single test) for materials testing and a relative standard deviation of 1.8 %.

47 OTHER INSTRUMENTATION↗

Phase-curve Pollution of Exoplanet Transmission Spectra

The occurrence of a planet transiting in front of its host star offers the opportunity to observe the planet’s atmosphere filtering starlight. The fraction of occulted stellar flux is roughly proportional to the optically thick area of the planet, the extent of which depends on the opacity of the planet’s gaseous envelope at the observed wavelengths. Chemical species, haze, and clouds are now routinely detected in exoplanet atmospheres through rather small features in transmission spectra, i.e., collections of planet-to-star area ratios across multiple spectral bins and/or photometric bands. Technological advances have led to a shrinking of the error bars down to a few tens of parts per million (ppm) per spectral point for the brightest targets. The upcoming James Webb Space Telescope (JWST) is anticipated to deliver transmission spectra with precision down to 10 ppm. The increasing precision of measurements requires a reassessment of the approximations hitherto adopted in astrophysical models, including transit light-curve models. Recently, it has been shown that neglecting the planet’s thermal emission can introduce significant biases in the transit depth measured with the JWST/Mid-InfraRed Instrument, integrated between 5 and 12 μm. In this paper, we take a step forward by analyzing the effects of the approximation on transmission spectra over the 0.6–12 μm wavelength range covered by various JWST instruments. We present open-source software to predict the spectral bias, showing that, if not corrected, it may affect the inferred molecular abundances and thermal structure of some exoplanet atmospheres.

47 OTHER INSTRUMENTATION↗

Development of a hybrid neural network and transfer learning model for optimized ICP-MS/MS operation

Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal Estimation Retrievals and Their Uncertainties: What Every Atmospheric Scientist Should Know

Remote sensing instruments are heavily used to provide observations for both the operational and research communities. These sensors do not provide direct observations of the desired atmospheric variables, but instead, retrieval algorithms are necessary to convert the indirect observations into the variable of interest. It is critical to be aware of the underlying assumptions made by many retrieval algorithms, including that the retrieval problem is often ill posed and that there are various sources of uncertainty that need to be treated properly. In short, the retrieval challenge is to invert a set of noisy observations to obtain estimates of atmospheric quantities. The problem is often complicated by imperfect forward models, by imperfect prior knowledge, and by the existence of nonunique solutions. Optimal estimation (OE) is a widely used physical retrieval method that combines measurements, prior information, and the corresponding uncertainties based on Bayes’s theorem to find an optimal solution for the atmospheric state. Furthermore, OE also allows the relative contributions of the different sources of error to the uncertainty in the final retrieved atmospheric state to be understood. Here, we provide a novel Python library to illustrate the use of OE for inverse problems in the atmospheric sciences. We introduce two example problems: how to retrieve drop size distribution parameters from radar observations and how to retrieve the temperature profile from ground-based microwave sensors. Using these examples, we discuss common pitfalls, how the various error sources impact the retrieval, and how the quality of the retrieval results can be quantified.

54 ENVIRONMENTAL SCIENCES↗

Editorial: Resolving atmospheric flow in complex environments: recent experiments in terrain and forest canopies

The characterization of atmospheric flows in complex environments, which may include steep terrain slopes and heterogeneous vegetation and/or forest cover, is a long-standing challenge in boundary-layer meteorology. Atmospheric observations are complicated by the presence of transient, terrain-induced flow features, forest-canopy-atmosphere interactions, and atmospheric stability effects, not to mention the logistical hurdles involved with instrument deployment, data analysis, and quality control. Furthermore, challenges in atmospheric modeling arise due to numerical errors associated with complex terrain flows, as well as reliance on simplified parameterizations for unresolved processes such as turbulent mixing and land-surface or forest-canopy-atmosphere interactions. These modeling challenges are exacerbated in the so-called “gray zone,” wherein features of interest have length scales that are similar to the model grid spacing, or when the principal flow layer is smaller than the grid spacing (e.g., slope flows).

54 ENVIRONMENTAL SCIENCES↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Characterizing Midcircuit Measurements on a Superconducting Qubit Using Gate Set Tomography

Measurements that occur within the internal layers of a quantum circuit—midcircuit measurements—are a useful quantum-computing primitive, most notably for quantum error correction. Midcircuit measurements have both classical and quantum outputs, so they can be subject to error modes that do not exist for measurements that terminate quantum circuits. In this work, we show how to characterize midcircuit measurements, modeled by quantum instruments, using a technique that we call quantum instrument linear gate set tomography (QILGST). We then apply this technique to characterize a dispersive measurement on a superconducting transmon qubit within a multiqubit system. By varying the delay time between the measurement pulse and subsequent gates, we explore the impact of residual cavity photon population on measurement error. QILGST can resolve different error modes and quantify the total error from a measurement; in our experiment, for delay times above 1000 ns we measure a total error rate (i.e., half diamond distance) of ϵ$\diamond$ = 8.1 ± 1.4%, a readout fidelity of 97.0 ± 0.3%, and output quantum-state fidelities of 96.7 ± 0.6% and 93.7 ± 0.7 % when measuring 0 and 1, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation-aware binning for small-angle neutron scattering via Gaussian-process inference

Binning in small-angle neutron scattering (SANS) is typically performed empirically, with fixed parameters chosen for convenience rather than statistical optimality. Such practices often fail to balance statistical precision and spatial resolution, leading to inconsistencies across instruments and datasets. Here we establish a correlation-aware framework that determines the optimal bin width from first principles by extending the classical Freedman–Diaconis (FD) rule to account for inter-bin correlations with a Gaussian process. In this formulation, the scattering intensity is treated as a smooth stochastic field whose statistical coherence is described by a covariance matrix. Analytical expressions of errors derived from this model yield closed-form criteria that separate the total deviation into contributions from counting noise, aliasing distortion and curvature-dependent correlation effects. Expressed in reduced variables, the resulting dimensionless error surface reveals a continuous transition from the uncorrelated FD regime to the correlation-dominated limit, providing a unified description of noise suppression and resolution control. Because the formulation depends only on the profile characteristics of scattering intensity I(Q), specifically its average intensity and first- and second-order derivatives, it applies generally to any SANS measurement regardless of sample, instrument or geometry. Experimental validation using small- and ultra-small-angle neutron scattering data confirms the predicted scaling behavior, demonstrating that correlation-aware inference systematically reduces mean-squared error and enables information-efficient reproducible data reduction across materials and instruments.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

Estimating the impacts of natural gas power generation growth on solar electricity development: PJM's evolving resource mix and ramping capability

Abstract Expansion of distributed solar photovoltaic (PV) and natural gas‐fired generation capacity in the United States has put a renewed spotlight on methods and tools for power system planning and grid modernization. This article investigates the impact of increasing natural gas‐fired electricity generation assets on installed distributed solar PV systems in the Pennsylvania–New Jersey–Maryland (PJM) Interconnection in the United States over the period 2008–2018. We developed an empirical dynamic panel data model using the system‐generalized method of moments (system‐GMM) estimation approach. The model accounts for the impact of past and current technical, market and policy changes over time, forecasting errors, and business cycles by controlling for PJM jurisdictions‐level effects and year fixed effects. Using an instrumental variable to control for endogeneity, we concluded that natural gas does not crowd out renewables like solar PV in the PJM capacity market; however, we also found considerable heterogeneity. Such heterogeneity was displayed in the relationship between solar PV systems and electricity prices. More interestingly, we found no evidence suggesting any relationship between distributed solar PV development and nuclear, coal, hydro, or electricity consumption. In addition, considering policy effects of state renewable portfolio standards, net energy metering, differences in the PJM market structure, and other demand and cost‐related factors proved important in assessing their impacts on solar PV generation capacity, including energy storage as a non‐wire alternative policy technique. This article is categorized under: Photovoltaics > Economics and Policy Fossil Fuels > Climate and Environment Energy Systems Economics > Economics and Policy

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SCOPE: Spectral cloud optical property estimation using real-time GOES-R longwave imagery

The output of ground-based, solar power generation systems is strongly dependent on cloud cover, which is the main contributor to solar power variability and uncertainty. Cloud optical properties are typically over-simplified in forecasting applications due to the lack of realtime, accurate estimates. In this work, we introduce a method, the Spectral Cloud Optical Property Estimation (SCOPE), for estimating cloud optical properties directly from high-resolution (5-min, 2 km) imagery from Geostationary Operational Environmental Satellite (GOES)-R, which is the newest generation of the GOES system. The SCOPE method couples a two-stream, spectrally resolved radiative model with the longwave GOES-R sensor output to simultaneously estimate the cloud optical depth, cloud top height, and cloud thickness during both day and night at 5-min intervals. The accuracy of SCOPE is evaluated using one year (2018) of downwelling longwave (DLW) radiation measurements from the Surface Radiation Budget Network, which consists of seven sites spread across climatically diverse regions of the contiguous United States. During daytime clear-sky periods, SCOPE predicts DLW within instrument uncertainty (10 W m -2 ) for four of the seven locations, with the remaining locations yielding errors of the order of 11.2, 17.7, and 20.2 W m -2 . For daytime cloudy-sky, daytime all-sky (clear or cloudy), and nighttime all-sky periods, SCOPE achieves root mean square error values of 23.0–34.5 W m -2 for all seven locations. These results, together with the low-latency of the method (1 s per sample), show that SCOPE provides a viable solution to real-time, accurate estimation of cloud optical properties for both day and night.

42 ENGINEERING↗