Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned

Historically, regulatory barriers have precluded nuclear plant safety-related (SR) Instrumentation and Control (I&C) system modernizations. These barriers have been largely addressed by industry and United States Nuclear Regulatory Commission (NRC) efforts, including development of the License Amendment Request (LAR) Alternate Review (AR) process for digital I&C upgrades. The U.S. Department of Energy (DOE) and the Idaho National Laboratory (INL) are supporting a SR I&C pilot upgrade at the Limerick Generating Station (LGS) to demonstrate this process and capturing associated lessons learned for the benefit of industry. In 2021, a paper summarizing lessons learned as captured in INL/EXT-20-59809, Safety Related Instrumentation & Control Pilot Upgrade Initial Scoping Phase Implementation Report and Lessons Learned was presented at the 12th NPIC & HMIT conference. It is recommended that readers of this paper review reference 1 or the associated Nuclear Journal paper for context. This paper summarizes activities performed and lessons learned for the conceptual design phase and portions of the detailed design phase as captured in INL/RPT-23-XXXX, “Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned.” The portions of the effort covered by reference 2 include conceptual design phase activities from December 2020, through completion in November 2021, and detailed design activities through September 2022. These efforts and associated detailed documentation in reference 3 are intended to support similar industry upgrades as a foundation stone for a Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Toward the Instrumentation and Data Acquisition of a Tidal Turbine in Real Site Conditions

The National Renewable Energy Laboratory manufactured, instrumented, and deployed thermoplastic composite blades and a data acquisition system (NDAQ) on one of Verdant Power’s Gen5d 5 m diameter tidal turbines in New York’s East River. The thermoplastic blades had internal strain gages, and the NDAQ was a stand-alone system for monitoring and recording the strain and angular position of the blades. The turbine with thermoplastic blades operated and produced power successfully for 3 months, contributing energy to the New York City electric grid. The NDAQ hardware, instrumentation, and structure all survived the deployment and were still functional upon retrieval of the system, but no data were collected. Even though the data retrieval was not a success, data acquisition for deployed subsea marine renewable structures is a new undertaking, and it is critical to share lessons learned from national laboratory experiences. The successful deployment of thermoplastic composite blades marks a significant advancement toward improved materials for subsea components, as well as an advancement in recyclable composite materials. This article outlines the methodology and lessons learned for the instrumentation and data acquisition system.

16 TIDAL AND WAVE POWER↗

Adaptable Monitoring Package Development and Deployment: Lessons Learned for Integrated Instrumentation at Marine Energy Sites

Integrated instrumentation packages are an attractive option for environmental and ecological monitoring at marine energy sites, as they can support a range of sensors in a form factor compact enough for the operational constraints posed by energetic waves and currents. Here we present details of the architecture and performance for one such system—the Adaptable Monitoring Package—which supports active acoustic, passive acoustic, and optical sensing to quantify the physical environment and animal presence at marine energy sites. we describe cabled and autonomous deployments and contrast the relatively limited system capabilities in an autonomous operating mode with more expansive capabilities, including real-time data processing, afforded by shore power or in situ power harvesting from waves. Across these deployments, we describe sensor performance, outcomes for biological target classification algorithms using data from multibeam sonars and optical cameras, and the effectiveness of measures to limit biofouling and corrosion. On the basis of these experiences, we discuss the demonstrated requirements for integrated instrumentation, possible operational concepts for monitoring the environmental and ecological effects of marine energy converters using such systems, and the engineering trade-offs inherent in their development. Overall, we find that integrated instrumentation can provide powerful capabilities for observing rare events, managing the volume of data collected, and mitigating potential bias to marine animal behavior. These capabilities may be as relevant to the broader oceanographic community as they are to the emerging marine energy sector.

16 TIDAL AND WAVE POWER↗

High-Speed and High-Power Ferroelectric Switching Current Measurement Instrument for Materials with Large Coercive Voltage and Remanent Polarization

A high-speed and high-power current measurement instrument is described for measuring rapid switching of ferroelectric samples with large spontaneous polarization and coercive field. Instrument capabilities (±200 V, 200 mA, and 200 ns order response) are validated with a LiTaO 3 single crystal whose switching kinetics are well known. The new instrument described here enables measurements that are not possible using existing commercial measurement systems, including the observation of ferroelectric switching in large coercive field and large spontaneous polarization Al 0.7 Sc 0.3 N thin films.

30 DIRECT ENERGY CONVERSION↗

The HETDEX Instrumentation: Hobby–Eberly Telescope Wide-field Upgrade and VIRUS

The Hobby–Eberly Telescope (HET) Dark Energy Experiment (HETDEX) is undertaking a blind wide-field low-resolution spectroscopic survey of 540 deg 2 of sky to identify and derive redshifts for a million Ly α -emitting galaxies in the redshift range 1.9 < z < 3.5. The ultimate goal is to measure the expansion rate of the universe at this epoch, to sharply constrain cosmological parameters and thus the nature of dark energy. A major multiyear Wide-Field Upgrade (WFU) of the HET was completed in 2016 that substantially increased the field of view to 22' diameter and the pupil to 10 m, by replacing the optical corrector, tracker, and Prime Focus Instrument Package and by developing a new telescope control system. The new, wide-field HET now feeds the Visible Integral-field Replicable Unit Spectrograph (VIRUS), a new low-resolution integral-field spectrograph (LRS2), and the Habitable Zone Planet Finder, a precision near-infrared radial velocity spectrograph. VIRUS consists of 156 identical spectrographs fed by almost 35,000 fibers in 78 integral-field units arrayed at the focus of the upgraded HET. VIRUS operates in a bandpass of 3500–5500 Å with resolving power R ≃ 800. VIRUS is the first example of large-scale replication applied to instrumentation in optical astronomy to achieve spectroscopic surveys of very large areas of sky. This paper presents technical details of the HET WFU and VIRUS, as flowed down from the HETDEX science requirements, along with experience from commissioning this major telescope upgrade and the innovative instrumentation suite for HETDEX.

79 ASTRONOMY AND ASTROPHYSICS↗

Qualifying the Instrument Thimble 11 Test Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Findings in Qualifying the Instrument Thimble 11 Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Cyber-Informed Engineering for Nuclear Reactor Digital Instrumentation and Control

As nuclear reactors transition from analog to digital technology, the benefits of enhanced operational capabilities and improved efficiencies are potentially offset by cyber risks. Cyber-Informed Engineering (CIE) is an approach that can be used by engineers and staff to characterize and reduce new cyber risks in digital instrumentation and control systems. CIE provides guidance that can be applied throughout the entire systems engineering lifecycle, from conceptual design to decommissioning. In addition to outlining the use of CIE in nuclear reactor applications, this chapter provides a brief primer on nuclear reactor instrumentation and control and the associated cyber risks in existing light water reactors as well as the digital technology that will likely be used in future reactor designs and applications.

42 ENGINEERING↗

Software Framework for Federated Science Instruments

There is an unprecedented promise of enhanced capabilities for federations of leadership computing systems and experimental science facilities by leveraging software technologies for fast and efficient operations. These federations seek to unify different science instruments, both computing and experimental, to effectively support science users and operators to execute complex workflows. The FedScI project addresses the software challenges associated with the formation and operation of federated environments by leveraging recent advances in containerization of software and softwarization of hardware. We propose a software framework to streamline the federation usage by science users and it’s provisioning and operations by facility providers. A distinguishing element of our work is the support for improved interaction between experimental devices, such as beam-line instruments, and more traditional high-performance computing resources, including compute, network, storage systems. We present guiding principles for the software framework and highlight portions of a current prototype implementation. We describe our science use case involving neutron imaging beam-lines (SNAP/BL-3, Imaging/CG-1D) at the Spallation Neutron Source and High Flux Isotope Reactor facilities at Oak Ridge National Laboratory. Additionally, we detail plans for a more direct instrument interaction within a federated environment, which could enable more advanced workflows with feedback loops to shorten the time to science.

Naughton III, Thomas↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

Blowing Snow at McMurdo Station, Antarctica During the AWARE Field Campaign: Multi-Instrument Observations of Blowing Snow

In polar regions, blowing snow (BLSN) can play a substantial role in regional thermodynamics and radiation properties. The extent of the impact depends upon the depth of the BLSN layer, a property that is difficult to measure and not well understood. The West Antarctic Radiation Experiment (AWARE) Field Campaign saw the deployment of a large suite of observational instruments to McMurdo Station, Antarctica, allowing for in-depth investigation of BLSN. During the year of the campaign, BLSN occurred ~7.4% of the time. In this study, additional remote sensing observations are used to supplement an existing ceilometer-based BLSN characterization algorithm creating a multi-instrument (MI) depth estimation algorithm to yield layer depths with more certainty. Backscatter coefficient and linear depolarization ratios from the micropulse and high spectral resolution lidar (HSRL) are incorporated along with color ratio derived from HSRL backscatter and Ka-band radar reflectivity observations. This provided estimates of BLSN depth that were less impacted by noise/artifacts in any one set of observations. When applied to the data from AWARE, the MI algorithm yielded an average depth of 168.2 m with ~60% of plumes less than 200 m in depth. Events occurring with precipitation saw the most value in the additional instruments, with the suite of observations allowing for more separation of BLSN particles from fallstreaks.

54 ENVIRONMENTAL SCIENCES↗

Operating advanced scientific instruments with AI agents that learn on the job

Advanced scientific user facilities, such as next generation X-ray light sources and self-driving laboratories, are revolutionizing scientific discovery by automating routine tasks and enabling rapid experimentation and characterizations. However, these facilities must continuously evolve to support new experimental workflows, adapt to diverse user projects, and meet growing demands for more intricate instruments and experiments. This continuous development introduces significant operational complexity, necessitating a focus on usability, reproducibility, and intuitive human-instrument interaction. In this work, we explore the integration of agentic AI, powered by Large Language Models (LLMs), as a transformative tool to achieve this goal. We present our approach to developing a human-in-the-loop pipeline for operating advanced instruments including an X-ray nanoprobe beamline and an autonomous robotic station dedicated to the design and characterization of materials. Specifically, we evaluate the potential of various LLMs as trainable scientific assistants for orchestrating complex, multi-task workflows, which also include multimodal data, optimizing their performance through optional human input and iterative learning. We demonstrate the ability of AI agents to bridge the gap between advanced automation and user-friendly operation, paving the way for more adaptable and intelligent scientific facilities.

Large Language Models↗

Planck 2018 Results - II. Low Frequency Instrument data processing

We present a final description of the data-processing pipeline for the Planck Low Frequency Instrument (LFI), implemented for the 2018 data release. Several improvements have been made with respect to the previous release, especially in the calibration process and in the correction of instrumental features such as the effects of nonlinearity in the response of the analogue-to-digital converters. We provide a brief pedagogical introduction to the complete pipeline, as well as a detailed description of the important changes implemented. Self-consistency of the pipeline is demonstrated using dedicated simulations and null tests. We present the final version of the LFI full sky maps at 30, 44, and 70 GHz, both in temperature and polarization, together with a refined estimate of the solar dipole and a final assessment of the main LFI instrumental parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Post-irradiation examination of optical components for advanced fission reactor instrumentation

The use of optical instrumentation in advanced nuclear fission systems, such as molten salt reactors, liquid metal-cooled reactors, and high-temperature gas-cooled reactors, has the potential to enhance reactor safety and economic performance through in situ and online measurement of reactor conditions. Selection of suitable optical components, such as optical windows and fibers, is essential for operation of optical instrumentation in intense radioactive and thermal environments inherent to nuclear reactor systems. We present the development and performance of a self-contained and mobile post-irradiation examination system for rapid characterization of the optical properties of materials. The instrument combines linear absorption and nanosecond Z-scan modules in a compact, relocatable design. The system mobility allows for the evaluation of optical samples at the site of irradiation, minimizing the delay between extraction from the irradiation site and optical characterization. This provides nearly real-time information on the material performance under simultaneous irradiation and thermal annealing, simulating the relevant conditions for the use of those components in nuclear power systems.

Morgan, Bryan William (ORCID:0000000224668764)↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE↗

Conceptual Polarization Setup at CENTAUR, the SANS/WANS Instrument at the Second Target Station of SNS

CENTAUR is a multifunctional general purpose small-angle and wide-angle neutron scattering instrument with diffraction and spectroscopic capability in the future Second Target Station at the Spallation Neutron Source of the Oak Ridge National Laboratory. To fill a gap in neutron polarization capability, the instrument will be designed to provide polarization analysis. Here we present the conceptual polarization setup at CENTAUR, as well as the Spin Echo Modulated Small-Angle Neutron Scattering setup which will further expand the length scale covered by the instrument.