Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PUMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Bistable polarization switching in a continuous wave ruby laser

Bistability in the output power, polarization state, and mode volume of an argon-ion laser pumped single mode ruby laser at 6943 A has been observed. The laser operates in a radially confined mode which exhibits hysteresis and bistability only when the pump polarization is parallel to the c-axis.

Lawandy, N. M.↗

Parametric study of ion heating in a burnout device (HIP-1)

Results of further studies on the Lewis Research Center hot-ion plasma source (HIP-1) are reported. Changes have been made in both the electrode geometry and materials to produce higher ion temperatures. Ion temperature increased significantly with increased vacuum pumping speed. The best ion temperatures achieved, so far, for H(+), D(+), and He(+) plasmas are estimated to be equal to, or greater than 0.6, equal to, or greater than 0.9, and equal to, greater than 2.0 keV, respectively. Electrode pairs produced high ion temperatures whether on the magnetic axis or off it by 5.5 cm. Multiple sources, one on-axis and one off-axis, were run simultaneously from a single power supply by using independent gas feed rates. A momentum analyzer has been added to the charge-exchange neutral particle analyzer to identify particles according to mass, as well as energy. Under any given plasma condition, the higher mass ions have higher average energies but not by as much as the ratio of their respective masses.

Sigman, D. R.↗

Advanced thermionic converter developments with microwave external pumping

This work reports ion generation in a cesium thermionic converter as part of advanced-model thermionic converter development research. A microwave with frequency in the range between 1-2 GHz is used to externally pump a thermionic converter as part of our effort in the verification of Lam's theory. It is found that the motive peak as predicted in the theory disappears whenever microwave power is used to excite the cesium plasma of the converter. The electron temperature is effectively heated by the microwave and the experimental data agrees with theory in the low-power output region.

Chiu, H. S.↗

Pioneer Venus large probe neutral mass spectrometer

The Pioneer Venus large probe neutral mass spectrometer (LNMS) uses a single focusing magnetic sector field mass analyzer with mass range of 1-208 amu, resolution sufficient to separate the mercury isotopes, and sensitivity sufficient to detect minor constituents in the 1 ppm range relative to the CO2 in the Venus atmosphere. A combination of ion and chemical pumping is used to maintain a vacuum in the mass analyzer and to remove the atmosphere gases which enter the ion source chamber through a special leak. A microprocessor controls the operation of the instrument through a highly efficient peak stepping and data compression program, permitting acquisition of a complete mass spectrum roughly once each minute.

Hoffman, J. H.↗

A trapped mercury 199 ion frequency standard

Mercury 199 ions confined in an RF quadrupole trap and optically pumped by mercury 202 ion resonance light are investigated as the basis for a high performance frequency standard with commercial possibilities. Results achieved and estimates of the potential performance of such a standard are given.

Cutler, L. S.↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗

Small mass spectrometer with extended measurement capabilities at high pressures

For the in situ investigation of planetary atmospheres a small Mattauch-Herzog mass spectrometer has been developed. Its high-pressure performance has been improved by incorporating differential pumping between the ion source and the analyzing fields, shortening the path-length as well as increasing the extraction field in the ion source. In addition doubly ionized and dissociated ions are used for mass analysis. These measures make possible operation up to 0.01 millibars. Results of laboratory tests related to linearity, dynamic range, and mass resolution are presented, in particular for CO2.

Von Zahn, U.↗

Global Properties of the Ejecta Absorptions in the Spectrum of Eta Carinae

Between 2400A to 3160A, we have identified approximately 500 absorption line complexes, each with up to 20 velocity components. Lines of Fe I, Fe II, Ti II, V II, Ni II, Co II, Mn II, Mg I, Mg II and Na I have been identified. Surprisingly, most of the lines originate from energy levels significantly above the ground level. This is indcative of optical pumping from the Central Source. Line widths and population of various levels are non-thermal. The relative column densities change with velocity. For example, Fe 11 column densities for one transition arising from approx. 0.l ev increase with ejecta velocity while Fe 11 column densities for another transition decreases with velocity. This may be due to softening of the ultraviolet radiation that pumps the various ions (neutrals) with velocity. If we assume that the distance of each system scales with distance from the Central Source, only a thirty percent change in distance is noted; yet the ratio of column densities for the Fe I1 examples given above changes by nearly thirty-fold. If the ejecta distance scales with distance from Eta Carinae, then it is likely that this ejecta originated at nearly the same time. The geometry of the Homunculus has been determined to be a double-lobed structure tilted out of the plane of the sky. We interpret the ejecta as being in the wall of the Southwest lobe, and that this wall just happens to be in line of sight from Eta Carinae to the observer. As Eta Carinae enters into the upcoming minimum, we are already seeing some evidence for changes in column densities due to changes in ultraviolet fluxes. This is reinforced by IUE observations that we have recently re-analyzed with respect to the 5.52 year (2020 +/- 10 days) spectroscopic period. Observations were done through STScI and funding was through the STIS GTO resources.

Gull, T. R.↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

Generation of High Pressure Oxygen via Electrochemical Pumping in a Multi-stage Electrolysis Stack

An oxygen pump can produce high-purity high-pressure oxygen. Oxygen ions (O.sup.2-) are electrochemically pumped through a multi-stage electrolysis stack of cells. Each cell includes an oxygen-ion conducting solid-state electrolyte between cathode and anode sides. Oxygen dissociates into the ions at the cathode side. The ions migrate across the electrolyte and recombine at the anode side. An insulator is between adjacent cells to electrically isolate each individual cell. Each cell receives a similar volt potential. Recombined oxygen from a previous stage can diffuse through the insulator to reach the cathode side of the next stage. Each successive stage similarly incrementally pressurizes the oxygen to produce a final elevated pressure.

Setlock, John A↗

Generation of High Pressure Oxygen via Electrochemical Pumping in a Multi-Stage Electrolysis Stack

An oxygen pump can produce high-purity high-pressure oxygen. Oxygen ions (O(2-)) are electrochemically pumped through a multi-stage electrolysis stack of cells. Each cell includes an oxygen-ion conducting solid-state electrolyte between cathode and anode sides. Oxygen dissociates into the ions at the cathode side. The ions migrate across the electrolyte and recombine at the anode side. An insulator is between adjacent cells to electrically isolate each individual cell. Each cell receives a similar volt potential. Recombined oxygen from a previous stage can diffuse through the insulator to reach the cathode side of the next stage. Each successive stage similarly incrementally pressurizes the oxygen to produce a final elevated pressure.

Setlock, John A↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

The LASL program in nuclear pumped liquid lasers

The development of nuclear-pumped, liquid-based lanthanide ion lasers is discussed. Early investigations of lanthanide ion lasers have lead to solid-state and gaseous neodymium lasers, and a demonstration of lasing in the liquid state. Solvents containing organic chelating agents have been employed in liquid Eu(+3) and Tb(+3) lasers to extend fluorescence lifetimes, however aprotic solvents have been found to enable the development of large-scale liquid lasers. The advantages to be gained from high-power nuclear-pumped lasers based on lanthanide solutions include the high density of fissile materials possible, and a nuclear pumping cell which can operate in either a nuclear or optical pumping mode is being fabricated at the Los Alamos Scientific Laboratory to investigate the nuclear pumping of liquid lanthanide ion lasers. Areas that need exploration before specific laser design features can be considered include energy channeling within the liquid upon excitation, radiation damage due to solvent dissociation, and reactor technology for the development of a self-critical liquid reactor.

Mansfield, C. R.↗