Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sandia National Laboratories FY20 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY20 the Energetic Neutrons campaign increased the number and complexity of experiments, continued collaborations with external organizations, and generated knowledge that supports SNL’s National Security mission. In FY20 the Energetic Neutrons campaign was executed by an early career team led by a new PI. The SNL team members were trained to take over new responsibilities during the shot day to increase the number and complexity of experiments in the campaigns. Also, in FY20 for the first time the Energetic Neutrons campaign had a graduate student contributing with pre and post-irradiation characterizations at SNL of the semiconductor devices irradiated at OMEGA. In FY20 SNL collaborated with the Air Force Nuclear Weapons Center (AFNWC) and supported experiments related to radiation effects in semiconductor devices. SNL also gave the opportunity to ride along to Los Alamos National Laboratory and multiple scientists from MIT and LLE. SNL continued using the last two generations of the Neutron Effects Diagnostics (NEDs) to field active and passive experiments but also redesigned the latest generation of the NEDs to accommodate larger components and improve the vacuum sealing as shown in figure 1a. The redesigned NEDs allowed SNL to perform active tests of a high voltage (HV) PCB for the first time at OMEGA; where signals before, during and after the irradiation were recorded. The HV PCB installed in one of the SNL NEDs is shown in figure 1b where a 3D-printed nosecone was used to check for mechanical and electrical interference. Passive irradiations of multiple components were followed up with leakage current, gain measurements and radiation-induced defect characterization.

42 ENGINEERING↗

SU-E-T-55: A Novel Applicator for High Dose Rate Brachytherapy Treatments of Ocular Conjunctiva

Purpose: To evaluate the clinical feasibility of IntraBeam intra operative kV irradiation beam device for ocular conjunctiva treatments. The Intra-Beam system offers a 4.4 mm diameter needle applicator, that is not suitable for treatment of a large surface with limits access. We propose an adaptor that will answer to this clinical need and provide initial dosimetry. Methods: The dose distribution of the needle applicator is non uniform and hence not suitable for treatment of relatively large surfaces. We designed an adapter to the needle applicator that will filter the X-rays and produce a conformal dose distribution over the treatment area while shielding surfaces to be spared. Dose distributions were simulated using FLUKA is a fully integrated particle physics Monte Carlo simulation package. Results: We designed a wedge applicator made of Polythermide window and stainless steel for collimating. We compare the dose distribution to that of the known needle and surface applicators. Conclusion: Initial dosimetry shows feasibility of this approach. While further refinements to the design may be warranted, the results support construction of a prototype and confirmation of the Monte Carlo dosimetry with measured data.

60 APPLIED LIFE SCIENCES↗

Simple model of the indirect compression of targets under conditions close to the national ignition facility at an energy of 1.5 MJ

The possibility of the analysis and interpretation of the reported experiments with the megajoule National Ignition Facility (NIF) laser on the compression of capsules in indirect-irradiation targets by means of the one-dimensional RADIAN program in the spherical geometry has been studied. The problem of the energy balance in a target and the determination of the laser energy that should be used in the spherical model of the target has been considered. The results of action of pulses differing in energy and time profile (“low-foot” and “high-foot” regimes) have been analyzed. The parameters of the compression of targets with a high-density carbon ablator have been obtained. The results of the simulations are in satisfactory agreement with the measurements and correspond to the range of the observed parameters. The set of compared results can be expanded, in particular, for a more detailed determination of the parameters of a target near the maximum compression of the capsule. The physical foundation of the possibility of using the one-dimensional description is the necessity of the closeness of the last stage of the compression of the capsule to a one-dimensional process. The one-dimensional simulation of the compression of the capsule can be useful in establishing the boundary behind which two-dimensional and three-dimensional simulation should be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV

The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., 'Considerations of rod-pinch diode operation in negative polarity for radiography,' in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., 'Theoretical modeling and experimental characterization of a rod-pinch diode,' Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., 'Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources,' IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., 'ASTERIX, a high intensity X-ray generator,' in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., 'Negative polarity rod pinch diode experiments on the ASTERIX generator,' in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to achieve the most comprehensive characterization of the diode, both optical and x-ray diagnostics were used, including high speed multi-image ICCD (intensified CCD) cameras, streak camera, dosimeters, spot size measurements, and pinhole cameras. A set of new results have been obtained through this study. The plasma emission from the anode and cathode surfaces and its expansion appear to be critical for the diode functioning. Also, for the first time, potential sources of diode instability were identified. Finally, an optimal and stable diode configuration was found with the following parameters: 52 rad at 1 m (in Al) and 2.2 mm spot size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗

Bias-dependent displacement damage effects in a silicon avalanche photodiode

Radiation effects studies on a commercial beveled-edge avalanche photodiode (APD) showed that applying reverse bias to the device during irradiation enhanced the severity of apparent damage. Proton microbeam irradiations were made using a proton beam energy of 2 MeV and fluence ranging from 2.0 × 10 10 to 5.1 × 10 12 cm -2 . Charge collection measurements using the ion beam induced charge (IBIC) technique showed that relative losses increased by up to an order of magnitude when the reverse bias applied during irradiation increased from 50 to 1500 V. The presence of reverse bias also led to equivalent losses in charge collection that would only be seen in irradiations with an order of magnitude higher fluence in unbiased APDs. The results demonstrate that bias-enhanced irradiation damage is insufficiently understood and must be accounted for in characterizations of radiation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-sculpting of nanopores in amorphous metals, semiconductors, and insulators

We report the closure of nanopores to single-digit nanometer dimensions by ion sculpting in a range of amorphous materials including insulators (SiO{sub 2} and SiN), semiconductors (a-Si), and metallic glasses (Pd{sub 80}Si{sub 20})--the building blocks of a single-digit nanometer electronic device. Ion irradiation of nanopores in crystalline materials (Pt and Ag) does not cause nanopore closure. Ion irradiation of c-Si pores below 100 deg. C and above 600 deg. C, straddling the amorphous-crystalline dynamic transition temperature, yields closure at the lower temperature but no mass transport at the higher temperature. Ion beam nanosculpting appears to be restricted to materials that either are or become amorphous during ion irradiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The wavelength dependent photovoltaic effects caused by two different mechanisms in carbon nanotube film/CuO nanowire array heterodimensional contacts

Hetrodimensional contacts were fabricated by coating double-walled carbon nanotube (CNT) films on CuO nanowire arrays. Wavelength dependent photovoltaic effects by irradiating the devices with 405, 532, and 1064 nm lasers were observed. Two possible mechanisms responsible for the observed results were discussed. Photoexcitations within CuO nanowires and Schottky barriers in the heterojunctions dominate the photovoltaics in the 405 and 532 nm cases. For the 1064 nm case, the photovoltaic is the result of the excitation within the CNTs and of the heterodimensionality effect. Control experiments on CNT film/CuO granular film hetrodimensional contacts further show the relationship between these two mechanisms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2–10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., “High power self-pinch diode experiments for radiographic applications” IEEE Trans. Plasma Sci. 35(3), 565–572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., “ASTERIX, a high intensity X-ray generator,” in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567–570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., “Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV,” Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode plasmas evolution, responsible for the gap closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of irradiation rig for reactor testing of prototype bolometers for ITER

We describe the design of an experimental rig, which was developed to allow reactor testing at relevant conditions, i.e. vacuum and {approx}400 deg.C temperature, of prototype resistive bolometers, which will be used in ITER to acquire information on the radiated power distribution from the main plasma and in the diverter region. The main feature of the design is that the rig has no active temperature control. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Event Effects in the Peripheral Circuitry of a Commercial Ferroelectric Random Access Memory

This paper identifies the failure modes of a commercial 130-nm ferroelectric random access memory. The devices were irradiated with heavy-ion and pulsed focused X-ray beams. Various failure modes are observed, which generate characteristic error patterns, affecting isolated bits, words, groups of pages, and sometimes entire regions of the memory array. Furthermore, the underlying mechanisms are discussed.

42 ENGINEERING↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

SU-E-T-606: Performance of MR-Based 3D FXG Dosimetry for Preclinical Irradiation

Purpose: Technological advances have revolutionized preclinical radiation research to enable precise radiation delivery in preclinical models. Kilovoltage x-rays and complex geometries in preclinical radiation studies challenge conventional dosimetry methods. Previously developed gel-based dosimetry provides a viable means of accommodating complex geometries and accurately reporting dose at kV energies. This paper will describe the development and evaluation of gel-based ferrous xylenol-orange (FXG) dosimetry using a 7T preclinical imaging system. Methods: To confirm water equivalence, Zeff values were calculated for the FXG material, water and ICRU defined soft tissue. Proton T1 relaxivity response in FXG was measured using a preclinical 7T MR and a small animal irradiator for a dose range of 1–22 Gy. FXG was contained in 50 ml centrifuge tubes and irradiated with a 225 kVp x-ray beam at a nominal dose rate of 2.3 Gy/min. Pre and post irradiation maps of the T1 relaxivity were collected using variable TR spin-echo imaging (TE 6.65 ms; TR 500, 750, 1000, 1500, 2000, 3000 and 5000 ms) with 2 mm thick slices, 0.325 mm/pixel, 3 averages and an acquisition time of 26 minutes. A linear fit to the change in relaxation rate (1/T1) for the delivered doses reported the gel sensitivity in units of ms{sup -1}Gy{sup -1}. Irradiation and imaging studies were repeated using three batches of gel over 72 hrs. Results: FXG has a Zeff of 3.8 for the 225 kVp spectrum used; differing from water and ICRU defined soft tissue by 0.5% and 2.5%, respectively. The average sensitivity for the FXG dosimeter was 31.5 ± 0.7 ms{sup -1}Gy{sup -1} (R{sup 2} = 0.9957) with a y-intercept of −29.4 ± 9.0 ms{sup -1}. Conclusion: Preliminary results for the FXG dosimeter properties, sensitivity, and dose linearity at preclinical energies is promising. Future work will explore anatomically relevant tissue inclusions to test MR performance. Student funding provided by The Terry Fox Foundation Strategic Initiative for Excellence in Radiation Research for the 21st Century at CIHR and the Gifford Ontario Student Opportunity Trust Fund.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Mark-18A (Mk-18A) Target Material Recovery Program Product Acceptance Criteria

The Mk-18A Target Material Recovery Program (MTMRP) was established in 2015 to preserve the unique materials, e.g. 244 Pu, in 65 previously irradiated Mk-18A targets for future use. This program utilizes existing capabilities at SRS and Savannah River National Laboratory (SRNL) to process targets, recover materials from them, and to package the recovered materials for shipping to ORNL. It also utilizes existing capabilities at ORNL to receive and store the recovered materials, and to provide any additional processing of the recovered materials or residuals required to prepare them for future beneficial use. The MTMRP is presently preparing for the processing of these valuable targets which is expected to begin in ~2019. As part of the preparations for operations, this report documents the preliminary acceptance criteria for the plutonium and heavy curium materials to be recovered from the Mk-18A targets at SRNL for transport and storage at ORNL. These acceptance criteria were developed based on preliminary concepts developed for processing, transporting, and storing the recovered Mk-18A materials. They will need to be refined as these concepts are developed in more detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of the HEU/LEU conversion on experimental facilities

The LVR-15 reactor is a multipurpose research facility used for basic research on horizontal channels, material and corrosion studies in loops and irradiation rigs, and for the isotope production. A conversion from HEU (IRT-2M 36%, so far used) to LEU (IRT-3M 19.5%, IRT- 4M 19.5%) is planned till 2010. The influence of the new type of fuel on the performance of the experimental facilities operated at the reactor has been studied. The comparison of the calculated neutron fluence rates and spectra using NODER operational code (3D nodal diffusion) and MCNP code for both the fresh and depleted cores was performed. Results of the analyses and future plans are presented in the article. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗