Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOTOPE SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

H, C, N, and O Isotopic Substitution Studies of the 2165 cm (4.62 micron) "XCN" Feature Produced by UV Photolysis of Mixed Molecular Ices

To better understand the chemical species that gives rise to the 2165/cm (4.62 micron) "XCN" absorption feature seen towards embedded protostars such as W33A, we have performed laboratory studies using deuterium (H-2) isotopic labeling. We report the observation of a small but significant deuterium isotope shift for the "XCN" peak which demonstrates that the atomic motion(s) causing the "XCN" band in the laboratory samples must involve hydrogen. We also report the results of C-13, N-15 and O-18 labeling experiments that are consistent with previously reported values.

Bernstein, Max P.↗

Calibration of the Galactic Cosmic Ray Flux

We report first Xe data on the cross-calibration of I-129-Xe-129(sub n) ages with conventional CRE ages, a method which is expected to provide information on the long-term constancy of the galactic cosmic ray (GCR) flux. We studied isotopic signatures of Xe released in stepwise heating, decomposition and melting of troilites in the Cape York iron meteorite to identify isotopic shifts in Xe-129 and Xe-131 due to neutron capture in Te-128 and Te-130. We also resolve components due to extinct 129I, spallation and fission Xe. There has recently been much speculation on the constancy of GCR over long time scales, as may be inferred from iron meteorites. If GCRs originate from supernova events, this provides the basis for postulating increased fluxes at locations with higher than average densities of supernovae, specifically in OB-associations. The solar system at present appears to be inside a local bubble between spiral arms and may experience an increased GCR flux.

Mathew, K. J.↗

Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Vibrational Spectra of HNIW and its Isotopologues: A Combined Experimental and Computational Study

Incorporating isotopically labelled materials in degradation experiments could help unravel the mechanism(s) of decomposition through use of the kinetic isotope effect. Characterizing synthesized isotopologues however requires an understanding of what observable signals are affected by the isotopic substitution. As vibrational spectroscopy can distinguish between isotopologues, it is an ideal characterization technique to evaluate isotopic variants. To this end, the vibrational spectra of HNIW and its deuterated ( 2 H), 13 C, 15 N (all), 15 N (nitro), and 18 O isotopologues have been computationally predicted in the gas phase using density functional theory. These results are compared to experimentally measured FTIR/ATR and Raman spectra of both unsubstituted HNIW and 15 N-labeled HNIW in which the six nitro groups were synthetically tagged with 15 N atoms ( 15 N nitro -HNIW). The experimental isotopic frequency shift for the -NO 2 asymmetric stretching frequencies agrees with that theoretically calculated (~35.7 cm-1 vs. 36.5cm-1, respectively). Furthermore, analysis of the theoretically predicted frequency shifts for all isotopologues suggest the -NO 2 bending modes are lower in frequency than previously reported. This assignment is supported by the experimentally measured isotopic shift of ~10.1 cm -1 for these features (consistent with the predicted shift of ~13.1 cm -1 ). This work expands our current understanding of the vibrational modes in HNIW as well as provides a method for future work on similar systems.

36 MATERIALS SCIENCE↗

Calculation of improved spallation cross sections

Several research groups have recently carried out highly precise measurements (to about 10 percent) of high-energy nuclear spallation cross sections. These measurements, above 5 GeV, cover a broad range of elements: V, Fe, Cu, Ag, Ta and Au. Even the small cross sections far off the peak of the isotopic distribution curves have been measured. The semiempirical calculations are compared with the measured values. Preliminary comparisons indicate that the parameters of our spallation relations (Silberberg and Tsao, 1973) for atomic numbers 20 to 83 need modifications, e.g. a reduced slope of the mass yield distribution, broader isotopic distributions, and a shift of the isotopic distribution toward the neutron-deficient side. The required modifications are negligible near Fe and Cu, but increase with increasing target mass.

Tsao, C. H.↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Oxygen Isotopes in Fresh Water Biogenic Opal: Northeastern US Alleroed-Younger Dryas Temperature Shift

The first oxygen isotope analysis of biogenic opal from lake sediments, from the Allerod/Younger Dryas transition in a core from Linsley Pond, Connecticut, gives an average estimate of a 6 C drop in temperature during the Younger Dryas. This shift represents temperatures during the bloom season, and may be less than the winter temperature drop. The sharp transition itself, with a duration of about 200 years, suggests that the temperature decrease may have been as large as 12 C. Previous estimates of the Allerod/Younger Dryas temperature shifts are controversial, and range from 3-20 C, suggesting that further interdisciplinary research on the same samples is warranted. One way that global climate change manifests itself is by redistributing energy throughout the globe. The Northern Hemisphere latitudinal temperature gradient during the late-glacial is at present a controversial topic. The magnitude of air temperature shifts during the Allerod/Younger Dryas (YD) oscillation are estimated from mid-latitude pollen records surrounding the North Atlantic to be 3-5 C in Europe [Lowe et al., 19941 and 3-4 C in the eastern US [Peteet et al., 1993]. In contrast, lake temperatures estimates derived from aquatic midge larvae in the Canadian eastern maritimes and Maine range from 6-20 C, with larger shifts at more southern sites [Levesque et al., 1997]. The magnitude of YD cooling in Greenland ice cores ranges from at least 7 C from the Bolling warming [Dansgaard et al., 1989] to 15 C - a more recent estimate from borehole temperatures [Cuffey et al., 1995]. The ice core geochemical records reveal that massive frequent and short-term (decadal or less) changes in atmospheric composition occurred throughout this event, suggesting a very dynamic circulation [Mayewski et al., 1993).

Shemesh, Aldo↗

Rapidly Assessing Changes in Bone Mineral Balance Using Natural Stable Calcium Isotopes

We demonstrate that variations in the Ca isotope ratios in urine rapidly and quantitatively reflect changes in bone mineral balance. This variation occurs because bone formation depletes soft tissue of light Ca isotopes, while bone resorption releases that isotopically light Ca back into soft tissue. In a study of 12 individuals confined to bed rest, a condition known to induce bone resorption, we show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker, while bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged. Ca isotopes can in principle be used to quantify net changes in bone mass. Ca isotopes indicate an average loss of 0.62 +/- 0.16 % in bone mass over the course of this 30-day study. The Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

Morgan, J. L. L.↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Equatorial Electronic Structure in the Uranyl Ion: Cs 2 UO 2 Cl 4 and Cs 2 UO 2 Br 4

Electric field gradient (EFG) tensors in the equatorial plane of the linear UO 2 2+ ion have been measured by nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) experiments and computed by relativistic Kohn–Sham methods with and without environment embedding for Cs 2 UO 2 Cl 4 and Cs 2 UO 2 Br 4 . This approach expands the possibilities for probing the electronic structure in uranyl complexes beyond the strongly covalent U–O bonds. The combined analyses find that one of the two largest principal EFG tensor components at the halogen sites points along the U–X bond (X = Cl, Br), and the second is parallel to the UO 2 2+ ion; in Cs 2 UO 2 Cl 4 , the components are nearly equal in magnitude, whereas in Cs 2 UO 2 Br 4 , due to short-range bromide–cesium interactions, the equatorial component is dominant for one pair of Br sites and the axial component is larger for the second pair. Additionally, the directions and relative magnitudes of the field gradient principal axes are found to be sensitive to the σ and π electron donation by the ligands and the model of the environment. Chlorine-35 NQR spectra of 235 U-depleted and 235 U-enriched Cs 2 UO 2 Cl 4 exhibited no uranium-isotope-dependent shift, but the resonance of the depleted sample displayed a 58% broader line width.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗