Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ignition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Diagnosing up-scattered deuterium–tritium fusion neutrons produced in burning plasmas at the National Ignition Facility (invited)

In the push to higher performance fusion plasmas, two critical quantities to diagnose are α-heat deposition that can improve and impurities mixed into the plasma that can limit performance. In high-density, highly collisional inertial confinement fusion burning plasmas, there is a significant probability that deuterium–tritium (DT) fusion products, 14.1 MeV neutrons and 3.5 MeV α-particles, will collide with and deposit energy onto (“up-scatter”) surrounding deuterium and tritium fuel ions. These up-scattered D and T ions can then undergo fusion while in-flight and produce an up-scattered neutron (15–30 MeV). These reaction-in-flight (RIF) neutrons can then be uniquely identified in the measured neutron energy spectrum. Further, the magnitude, shape, and relative size of this spectral feature can inform models of stopping-power in the DT plasma and hence is directly proportional to α-heat deposition. In addition, the RIF spectrum can be related to mix into the burning fuel, particularly relevant for high-Z shell and other emerging National Ignition Facility platforms. The neutron time-of-flight diagnostic upgrades needed to obtain this small signal, ~10 –5 times the primary DT neutron peak, will be discussed. Results from several gain > 1 implosions will be shown and compared to previous RIF spectra. Finally, comparisons of experimental data to a simplified computational model will be made.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying fission yields at the National Ignition Facility using depleted uranium foil experiments

There are programs for high-Z shell experiments at the National Ignition Facility (NIF). For shells made of actinide material, a quantitative fission diagnostic is needed in order to determine how much fission took place and whether the fission was sufficient to produce a non-negligible heat source in the burning capsule. Here, we present a viable coupled experimental and theoretical technique for making quantitative fission measurements possible. The proposed scheme involves using a well-characterized set of depleted uranium foils outside an NIF capsule to verify the conversion of xenon and krypton fission fragments collected at the Radiochemical Analysis of Gaseous Samples (RAGS) facility into total fission yield. We present the calculations needed for this conversion, including the decays in and out of fission fragment chains during the RAGS pump-down of the NIF chamber.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the 3He + 3He Gamow energy probed in high energy density plasmas at the National Ignition Facility

Polar-direct-drive implosions at the National Ignition Facility generated large plasma volumes to study the 3He + 3He fusion reaction. The ion temperature, which determines the Gamow peak energy, was constrained by isolating the thermal contribution to the D3He-proton spectral width in a 3He plasma doped with deuterium. X-ray penumbral imaging was used to measure electron temperature, density, and hotspot volume, which was subsequently used to model the spectral broadening from plasma stopping power. Results showed 30% of the D3He-proton spectral width was due to stopping power, with residual flows contributing ≈10%. The 3He temperature was determined as T3He = 12.4 ± 3.2 keV, corresponding to a Gamow energy of 95 ± 14 keV. These experiments achieved the lowest Gamow energy to date for studying 3He + 3He fusion in high energy density plasma, approaching conditions in the Sun.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized ICF implosions: Ignition at low laser energy using designs with more ablator mass remaining

This paper is the first work to redesign a spherical ICF implosion to best utilize the benefits of applying an external magnetic field. The sub-ignition experiment N170601 is taken as the baseline design, which used 1.57 MJ of laser energy. The optimum magnetized design benefits from increasing the shell thickness by 14 μ m and decreasing the ice thickness by 18 μ m, resulting in a neutron yield of 8.9 × 10 17 . This is 34 × greater than the unmagnetized simulation of the same design, and 18.5 × the greatest unmagnetized simulation across all designs simulated. The resultant implosion velocity for the magnetized design is lower, which would also reduce ablation front instability growth. This design was found by using a simplified 1D magnetization model and then validated against full 2D extended-MHD capsule simulations with radiation asymmetries applied to correct the shape.

Walsh, Christopher A. [Lawrence Livermore National↗

Radiation drive designed to extend the pressure ranges measured in Gbar equation of state experiments at the National Ignition Facility

We present the design and demonstration of a Shock-Strengthening hohlraum radiation temperature drive in the Gbar experimental platform at the National Ignition Facility intended to increase the pressure range measured in a single experiment. Previously published experiments by Döppner et al. measured the equation of state in polystyrene from 25 to 60 Mbar. Recent experimental data of the Shock-Strengthening drive initially demonstrated a much larger pressure range from 15 to 110 Mbar using the same peak radiation temperature and experimental platform. The Shock-Strengthening drive starts with a low temperature foot that launches a weak shock into the sample and is followed by a continuous increase in radiation temperature to strengthen the leading shock. The additional strengthening increases the pressure within the sample beyond what is achievable by convergence alone. Design features of the Shock-Strengthening drive and accompanying radiation hydrodynamics simulations are used to illustrate the method by which the pressure range is increased from previous experiments. This method of modifying the radiation temperature drive can be used on the Gbar platform to significantly increase the range for equation of state data collected in a single experiment for many materials.

Physics - Plasma physics↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

Platform for 100 s Mbar equation of state measurements on the National Ignition Facility

Equation of state (EOS) measurements in the 100 s Mbar range are needed to underwrite models employed in the simulation of high energy density plasmas. To this end, a platform has been developed for fielding on the National Ignition Facility, capable of producing high-quality impedance match EOS data, wherein a planar, high-pressure, steady shock is driven into a sample package, and sample and reference standard shock velocities are measured. This platform, dubbed planar high pressure, or PHP, was fielded with an initial proof-of-concept shot in January 2023. The first PHP shot, aiming to study gold, demonstrated a pressure close to 400 Mbar, two orders of magnitude higher than previously reported gold EOS data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the 75 As ⁢(𝑛, 2⁢𝑛) cross section at 14.1 MeV at the National Ignition Facility

Here, a new measurement of the 75 As (𝑛, 2⁢𝑛) measurement was performed using the 14.1 MeV neutron pulse produced by fusion experiments at the National Ignition Facility (NIF). The target material consisted of GaAs foils encapsulated in aluminum irradiation containers, along with Au monitor foils, and positioned in the NIF chamber during high neutron yield shots. After irradiation, the GaAs and Au foils were counted with high purity germanium detectors to assess the production of (𝑛, 2⁢𝑛) activation products to determine the flux and the cross section of interest. The measured cross section was 966 ± 71 mb at 14.1 ± 0.37 MeV. This work provides a proof of concept for a platform for performing “ride-along” cross section measurements at NIF to contribute to existing nuclear data as well as measure new cross sections in the future.

and nuclear chemistry↗

Demonstration of a Novel Radiochemical Mix Diagnostic for Fusion Implosions at the National Ignition Facility

Mixing of the ablator material into the fuel of an inertial confinement fusion implosion reduces compression and enhances radiative losses, preventing ignition. Here, we describe a novel use of charged-particle radiochemistry to measure the ablator mix in contact with the fusion hot spot. The capsule uses a graded Be-Cr layer to increase the confinement of the hot spot. 52 Mn and 51 Cr isotopes are collected from the implosion and counted, and the ratio is related to the amount of Cr mixed into the hot spot. Thus, a new diagnostic to determine the degradation due to mix on fusion implosions has been developed.

MacLaren, S. A. [Lawrence Livermore National Labor↗

Pump depletion and the Raman gap in ignition-scale plasmas

Laser-plasma instabilities under ignition conditions for direct-drive inertial confinement fusion are studied using two-dimensional Particle-in-Cell simulations with a combination of in-plane (PP) and out-of-the-plane (SP) lasers. The results show that stimulated Raman side scattering can induce significant pump depletion and form a gap in the Raman scattered light spectra that have been observed in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the deficiency in inertial confinement fusion hohlraum x-ray flux predictions using experiments at the National Ignition Facility

The predicted implosion performance of deuterium-tritium fuel capsules in indirect-drive inertial confinement fusion experiments relies on precise calculations of the x-ray drive in laser-heated cavities (hohlraums). This requires accurate, spectrally dependent simulations of laser to x-ray conversion efficiencies and x-ray absorption losses to the hohlraum wall. A set of National Ignition Facility experiments have identified a cause for the long-standing hohlraum “drive deficit” as the overprediction of gold emission at ~2.5 keV in nonlocal thermodynamic equilibrium coronal plasma regions within the hohlraum. Finally, reducing the emission and absorption opacity in this spectral region by ~20% brings simulations into agreement with measured x-ray fluxes and spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization Methodology of Polar Direct-Drive Illumination for the National Ignition Facility

Improved laser illumination uniformity drives shocks and implosions to create more extreme high energy density environments. Predominantly, the geometry of experiments that can be performed is dictated by the layout of beams at laser facilities, limiting inter-facility and multiscale investigations. This Letter presents the first automated, algorithmic approach for generating illumination configurations for high energy density experiments. The method is demonstrated in comparison to a polar direct drive solid target experiment at the National Ignition Facility. The new illumination configuration is simulated to create greater than ×3 higher peak pressure and almost ×2 higher density by maintaining better shock uniformity. Furthermore, the optimization process is performed with reduced computational expense and isotropic plasma profiles, while accounting for the impact of cross-beam energy transfer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing the deuterium-tritium fusion resonance to diagnose thermal runaway in igniting plasmas

For high-efficiency inertial confinement fusion implosions, it is predicted that a burning hot spot will successfully encompass all surrounding fuel and then transition into a thermal runaway where the internal energy increase from fusion occurs on a timescale faster than the expansion of the fuel is able to quench the fusion chain reaction after ignition occurs. Observation of this dynamic phase transition would indicate distinct burn properties and indicate an implosion's robustness. A technique for diagnosing the presence of thermal runaway from measurements of nuclear reaction history is presented. The technique is based on taking the logarithmic derivative of the nuclear reaction history, called the 𝛼 curve, and allowing a mathematical decoupling of the mass, volume, and thermal reactivity in the fusion reaction rate equation. During thermal runaway, where the thermal temperature dominates the burn dynamics, a maximum in the 𝛼 curve is found where there is a maximum in the first derivative of the thermal fusion reactivity, an effect to the deuterium-tritium (DT) fusion cross-section resonance. This provides a distinct signature related to the fundamental nature of the DT fusion nuclear resonance and signifies the transition into the fusion thermal instability. Impacts of charged particle transport on the effect are also assessed and the analytical formulas are compared and found to be in agreement with radiation hydrodynamic codes.

high-energy-density plasmas↗

Optimizing fused silica debris shield use in the National Ignition Facility

The National Ignition Facility (NIF) deliberately and routinely operates with its final optics exposed to fluences likely to induce and grow damage. This choice has enabled the NIF to operate at energies previously unachievable at the expense of limitations to delivered power and energy contingent on the ability to repair damage on the final optics. Prior to the introduction of the fused silica debris shield (FSDS), the grating debris shield (GDS) was the optic type on the NIF most prone to damage and hence a primary limiter to the delivered energy. The introduction of the FSDS has reduced the damage initiation rate on the GDS by about two orders of magnitude to date. Despite the FSDS being a disposable optic, it is important to understand how the FSDS damages and when its damage requires it to be exchanged to maximize the FSDS lifetime while still protecting the GDS from damage. We will define the FSDS exchange criteria and evaluate the damage initiation mechanisms of the FSDS. The surface damage morphologies provide insight into the impact of the various damage mechanisms that limit the FSDS lifetime. These results are utilized in our analysis to optimize the FSDS exchange criteria to further extend the GDS lifetime.

42 ENGINEERING↗