Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VI-IRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project athttps://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

Experimental Examination of Additively Manufactured Patterns on Structural Nuclear Materials for Digital Image Correlation Strain Measurements

Abstract Background There are a limited number of commercially available sensors for monitoring the deformation of materials in-situ during harsh environment applications, such as those found in the nuclear and aerospace industries. Such sensing devices, including weldable strain gauges, extensometers, and linear variable differential transformers, can be destructive to material surfaces being investigated and typically require relatively large surface areas to attach (> 10 mm in length). Digital image correlation (DIC) is a viable, non-contact alternative to in-situ strain deformation. However, it often requires implementing artificial patterns using splattering techniques, which are difficult to reproduce. Objective Additive manufacturing capabilities offer consistent patterns using programmable fabrication methods. Methods In this work, a variety of small-scale periodic patterns with different geometries were printed directly on structural nuclear materials (i.e., stainless steel and aluminum tensile specimens) using an aerosol jet printer (AJP). Unlike other additive manufacturing techniques, AJP offers the advantage of materials selection. DIC was used to track and correlate strain to alternative measurement methods during cyclic loading, and tensile tests (up to 1100 µɛ) at room temperature. Results The results confirmed AJP has better control of pattern parameters for small fields of view and facilitate the ability of DIC algorithms to adequately process patterns with periodicity. More specifically, the printed 100 μm spaced dot and 150 μm spaced line patterns provided accurate measurements with a maximum error of less than 2% and 4% on aluminum samples when compared to an extensometer and commercially available strain gauges. Conclusion Our results highlight a new pattern fabrication technique that is form factor friendly for digital image correlation in nuclear applications.

Novich, K. A. (ORCID:0000000204466022)↗

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

A Proof for the Unbiased Nature of Range-Doppler Measurements in Coarse-Resolution Dechirp-on-Receive Feedback Synthetic Aperture Radar Navigation

In feedback synthetic aperture radar (SAR) navigation, observables extracted from SAR range-Doppler images correct position and velocity errors accumulated within an associated navigation system. Unlike most other sensors, which produce measurements without input from a navigation system, SARs require a prior estimate of the radar’s position and velocity to adjust the radar’s matched filter during range-Doppler image formation. Consequently, it is possible for position and velocity errors within a navigation system to manifest as additional errors (biases) in the range-Doppler measurement observables. Prior work has not tackled this possibility in the context of feedback SAR navigation with a dechirp-on-receive radar. This paper offers a proof demonstrating that range-Doppler observables extracted from coarse-resolution vertical SAR images formed with a dechirp-on-receive radar may be safely modeled as unbiased measurements of the radar’s true position and velocity despite the presence of moderate navigation errors.

dechirp-on-receive↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VIIRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project at https://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Raspberry Pi–powered temperature monitoring of growth chamber microclimates

While controlled environments are desirable for growing and measuring plants, growth chambers and greenhouses typically have microclimates that impact plant growth, development, and stress responses. Furthermore, opening and closing the doors of a controlled environment introduces variation in the environment, especially at temperature extremes, affecting both the measurements and the organisms within. Using multiple temperature data loggers to normalize results can be cost-prohibitive and rarely offers real-time feedback on temperature status. We used low-cost single-board computers, cameras, and temperature sensors to manage and capture growth chamber temperatures while acquiring plant image data. Detailed here are methods to document microclimates within a growth chamber so that data can be normalized to measured temperature information. This protocol describes a low-cost method for automated temperature monitoring, which enables both high-throughput measurements of temperature along with plant growth and stress responses via plant imaging.

Plant Sciences↗

Microbial spies and bloggers: programming cells to convert environmental information into discernible signals

Microbes regulate their dynamic behaviors using the chemical and physical characteristics of their environment. The ability of microbes to continuously convert this physicochemical information into biochemical information and to use organic matter in the environment as a power source makes these organisms attractive as chassis for building sensors. However, most biosensors have severe limitations when considering applications in hard-to-image settings like soils, sediments, and wastewater. Emerging technologies at the interface of biomolecular design, microbiome engineering, and synthetic biology offer new tools to program cells and communities as biosensors for these settings. Here, in this review, we describe innovations in biosensor outputs that are enabling new applications in complex environments, including reporters that are read out using electrochemical, gas chromatography, hyperspectral imaging, and next-generation sequencing methods. We also discuss computational advances that are accelerating the diversification of sensing components by mining metagenomics data for new transcriptional regulators and by designing allosteric protein switches that directly regulate reporter outputs using analytes. We highlight emerging opportunities for programming undomesticated microbes in communities to function as distributed sensors in the environment. Finally, we discuss the need for responsible biosensor development and to modernize regulatory frameworks to support evidence-based assessment of environmental biosensors.

analyte↗